[Page 1] Town & Country Fireplaces TC36

SERIAL # TC36 & TC36ARCH INSTALLATION AND OPERATING INSTRUCTIONS 030615-48 TC36_D & TC36_DAR ...

[Page 2] Town & Country Fireplaces TC36

Table of Contents Caution ...................................................................3 Safety ..................................................................... 3 Important Note for the Commonwealth of Massachusetts ........................

[Page 3] Town & Country Fireplaces TC36

FOR YOUR SAFETY - Do not install or operate your Town & Country replace without rst reading and understanding this manual. Any installation or operational deviation from the following instructions voids the Town & Country Fireplaces...

[Page 4] Town & Country Fireplaces TC36

From Massachusetts Rules and Regulations 248 CMR 5.08: (a) For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or op...

[Page 5] Town & Country Fireplaces TC36

47 3/4" 32 1/2" 3 5/8" 38 1/2" 36 1/8" 32 1/2" 26 7/16" 38 1/2" 47 3/8" 26 1/16" 24 5/8" Fig. #2 38 1/2" 47 7/8" 32 1/2" 3 5/8" 32 1/2" 2...

[Page 6] Town & Country Fireplaces TC36

** 24" * 38 1/8" 4" * MANTEL CLEARANCE A 9” B 6” C 3” ** MANTEL DEPTH D 12” E 6 3/4” F 1 1/2” MANTEL CLEARANCE CHART Minimu...

[Page 7] Town & Country Fireplaces TC36

The Town & Country Fireplace installation and venting must conform to the current CAN/CGA-B149 installation code (in Canada) or the current National Fuel Gas Code, ANSI Z223.1 (in the USA), and approved per local codes. Only qualied (license...

[Page 8] Town & Country Fireplaces TC36

The top standoffs are shipped loose inside the replace and must be installed on top of the replace as shown in Fig #9. Do this once the replace is on site and in position. In planning the installation for the replace, it is necessary t...

[Page 9] Town & Country Fireplaces TC36

IT IS HIGHLY RECOMENDED THAT A FULL HEADER BE INSTALLED ABOVE THE METAL FRAMING KIT 50 1/4" 48 1/16" Note: The replace should be in place and venting installed before framing in or building an enclosure around the unit. The...

[Page 10] Town & Country Fireplaces TC36

Fig.#13 TC 36D Minimum Combustible Framing Dimensions TC 36D Arch Minimum Combustible Framing Dimensions Fig.#12 20 7/8" 50 1/4" 29 1/2" 61 1/16" 61 1/16" 86 5/16" 48 1/8" 50 1/4" MINIMUM COMBUS...

[Page 11] Town & Country Fireplaces TC36

5 9/16” 12” IF FINISHING THE WALL ABOVE THE UNIT WITH PAINT, THE FRAMING KIT SHIPPED WITH THE UNIT SHOULD BE DISCARDED. USE FULL SHEETS OF CALCIUM SILICATE BOARD OR EQUIVALENT AND FULL LENGTH METAL STUDS TO FINISH AND FR...

[Page 12] Town & Country Fireplaces TC36

5 6 4 2 3 8 7 9 Attachment points Attachment points ARCHED STUD FRAMING KIT PARTS TC36.BRFRKITA ITEM NO. DESCRIPTION QTY. 1 (not shown) SCREWS. TEK 40 2 STUD SIDE. INNER 48” L 2 3 STUD VERT. OUTER 48” L 2 4 STUD VERT. CENTER 2 5 STUD HEADER,...

[Page 13] Town & Country Fireplaces TC36

3 7 5 Regular Frame Arch Frame 3 2 4 6 8 8 Non- combustible board 1. Top Frame Assembly • Lay out the inner (2) and outer (3) vertical side studs, and vertical center studs (4) on a large at surface. • Using the screws provi...

[Page 14] Town & Country Fireplaces TC36

3/8 SECURING BOLT WINDOW TRIM FLANGED EDGE HEMMED EDGE Adjustable Lintel Fig. #20 Fig. #21 1. The adjustable lintel assembly has two orientations for desired nishing. A anged edge and a hemmed edge. The lintel comes factory installed with...

[Page 15] Town & Country Fireplaces TC36

1/4" 1" MAX WINDOW FRAME HEARTH EXTENSION WINDOW TRACK SUB- FLOOR Caution: While a hearth extension is not required and combustible ooring materials may be brought directly up to the replace, many materials (such as wood oorin...

[Page 16] Town & Country Fireplaces TC36

The gas control system is located on the right hand side of the rebox behind an access panel and the decorative rebox panel (if installed). The replace is operated via a wall control and a hand held remote control unit. The wall control is...

[Page 17] Town & Country Fireplaces TC36

Fig. #27 Linking the remote control unit to the wall switch. 1. Begin by moving the selector toggle on the wall switch to the “REMOTE” position. 2. Insert a straightened paper clip into the “PROGRAM” slot on the wall switch. 3. Pre...

[Page 18] Town & Country Fireplaces TC36

TO HOME AUTOMATION SYSTEM NOTE: • Digital I/O must be connected to a dry contact relay. • Analog ame and light input through 0 - 10 volt DC signal scaled as follows: Low = 1 volt High = 10 volts NOTE: When a signal has been su...

[Page 19] Town & Country Fireplaces TC36

SUPPLY PRESSURE MANIFOLD PRESSURE Correct gas pressure requirement: Natural Gas Propane Min. Pressure 5.0" WC 12.5" WC (For purpose of input adjustment) Max. Pressure 13.9" WC 13.9" WC Manifold Pressure Maxim...

[Page 20] Town & Country Fireplaces TC36

Exterior wall opening: Determine the exact position of the replace so that the vent pipe is centered (if possible) between two building framing members. Consult your local building codes prior to proceeding. The vent kit will accommodate up to ...

[Page 21] Town & Country Fireplaces TC36

WALL THIMBLE AND VENT MUST NOT PROTRUDE BEYOND SIDING Fig. #34 Wall thimble: Where a vent pipe passes through a combustible wall, a wall thimble/shield must be used to retain insulation and maintain proper clearances. The wall thimble may be cut to ...

[Page 22] Town & Country Fireplaces TC36

Vent pipe: Install vent pipe through the wall thimble and attach to ue outlet collar on top of the replace. Secure all joints with screws and seal with approved "High Temp." self-adhesive aluminum tape provided. Adjust the replac...

[Page 23] Town & Country Fireplaces TC36

NOTE: The vent must not exceed a total length of 68 feet. Any combination of rise and run may be used but must be constrained to the boundaries of this chart. A total of 3 - 90° elbows or combination of other elbows equalling 90° can be used ...

[Page 24] Town & Country Fireplaces TC36

Fig. #39 Roof Termination Venting Chart NOTE: The vent must not exceed a total length of 68 feet. Any combination of rise and run may be used but must be constrained to the boundaries of this chart. A total of 4 - 90° elbows or combination of ...

[Page 25] Town & Country Fireplaces TC36

B 14 1/2" A Ceiling Opening: 1. Determine the exact position of the replace so that the vent pipe is centered (if possible) between two building framing members. Lay out the vent system path, minimizing the number of elbows and length of...

[Page 26] Town & Country Fireplaces TC36

Roof Vent Terminal: 1. Place the roof ashing over the vent pipe, secure and seal it to the roof using the methods and materials appropriate for the type of roof on the building. Shingle roof example shown (Fig #42). 2. Place the storm collar d...

[Page 27] Town & Country Fireplaces TC36

Fig. #44 M K I A V G G H A J V G A B C A V V A V B F B L V E V V V D A= *12 inches (30 cm) min. Clearances above grade, veranda, porch, deck, or balcony B= *12 inches (30 cm) min. Clearance to window or door that may be opened C= 12 inches (3...

[Page 28] Town & Country Fireplaces TC36

All outer joints of the vent pipe must be sealed with the approved "High Temperature" self- adhesive aluminium tape provided. Wrap the tape completely around the joint and press rmly in place. Fig. #45 Fig. #46 After sealing the vent pi...

[Page 29] Town & Country Fireplaces TC36

CAUTION: The vent restrictor must be fully open when using the power vent The vent restrictor is located on the underside of the  rebox top. The unit leaves the fac- tory with the vent restrictor open. The restrictor is built into the appliance f...

[Page 30] Town & Country Fireplaces TC36

16 1/2" 16 1/2" 9 5/8" 16 1/2" 9" WALL SHIELD / CEILING FIRESTOP TCVT.THIMA - OPTIONAL TCVT.WTA VERTICAL TERMINATION CAP TCVT.9365 ROOF SUPPORT BRACKET TCVT.93915 STORM COLLAR TC42.90665 WALL SHIELD / CEILING FIRESTOP TCVT....

[Page 31] Town & Country Fireplaces TC36

45° 11" 9 1/2" 10 15/16" 10 5/16" 15 7/8" 7/16" 1 5/16" 8 5/16" 13 13/16" 12 9/16" 13 1/8" * 11 1/8" TCVT.811X12ADJ TCVT.811XLB45 TCVT.811XLB90 TCVT.811X _ _ 12" PIPE .......... 10 1...

[Page 32] Town & Country Fireplaces TC36

18 3/4" 1 1/4 “ 20" 11 3/8" 10 7/8" 1 1/4” B A 1 1/4“ 20” B A C 1 1/4“ B A C 1 1/4” ADDING AN ADJUSTABLE SECTION TO PIPE WILL INCREASE OFFSET BY 2 1/8" TO 6 3/4" A ...

[Page 33] Town & Country Fireplaces TC36

The lower rear panel is held tight against the side panels by two "V" brackets located on the rebox rear wall. Although the brackets are adjusted at the factory for the best t, some adjustment may be necessary. Adjust the an- gle ...

[Page 34] Town & Country Fireplaces TC36

1. Place two smaller magnets on back of each side rail. 2. Place two larger magnets on back of the top and bottom rails. 3. Attach the side rails. Even the ends up with the door frame. 4. Attach the top and bottom rails and adjust so mitre...

[Page 35] Town & Country Fireplaces TC36

FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS TO TURN OFF GAS APPLIANCE WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or ...

[Page 36] Town & Country Fireplaces TC36

First Fire When lit for the  rst time, the  replace will emit a slight odor for a couple of hours. This is due to the curing of paints, seal- ants and lubricants used in the manufacturing process. This condition is temporary. Open doors and win...

[Page 37] Town & Country Fireplaces TC36

Key Lock Transmission Low battery alarm Thermostat OFF/ ON/SMART Room Temperature CPI mode Set Point: Temperature/Level/State Aux ON Flame ON Split Flow Dimmer ON Comfort fan Fig. #57 Remote Control Transmit...

[Page 38] Town & Country Fireplaces TC36

Fireplace Description The Proame2 Remote Control Fireplace consists of three elements: 1. Proame2 Remote Control Transmitter. 2. Proame Integrated Fireplace Control (IFC) board and a wiring harness to connect the IFC to the gas va...

[Page 39] Town & Country Fireplaces TC36

Program button Using the Remote Control Transmitter Fig. #60 Town & Country wall switch face plate. Fig. #58 wall switch electronics Fig. #59 wall switch batteries side Fig. #61 Remote Control Transmitter battery bay Fig. ...

[Page 40] Town & Country Fireplaces TC36

Remote Flame Control The Pro ame2 has six (6)  ame levels. With the  replace turned on, and the  ame level at maximum height, press the down arrow key once (Fig. 64 Flame level 1) to reduce the  ame height by one step until the  ...

[Page 41] Town & Country Fireplaces TC36

Low Battery Power Detection Transmitter The life span of the remote control batteries depends on various factors: quality of the batteries used, the number of ignitions of the Heater, the number of changes to the room thermostat set point, etc. Wh...

[Page 42] Town & Country Fireplaces TC36

CAUTION: Turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is recommended that the replace and its venting should be inspected at least once a year by a qualied se...

[Page 43] Town & Country Fireplaces TC36

Fig. #75 (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) #1.....TC36 BODY ASSEMBLY 1a FIREBOX SHIELD (c/w insulation) 1b FLUE DAMPER 1c FIREBOX REAR SHIELD 1d SPRING LATCH ASSEMBLY(2) 1e CONTROL ASSEMBLY HOLDER 1f BRICK PANE...

[Page 44] Town & Country Fireplaces TC36

#1 #2 #3 #4 Fig. #76 #5 KIT CONTENTS: #1.....TC36 ARCH BODY ASSEMBLY 1a FIREBOX SHIELD (c/w insulation) 1b FLUE DAMPER 1c FIREBOX REAR SHIELD 1d SPRING LATCH ASSEMBLY(2) 1e CONTROL ASSEMBLY HOLDER BRICK PANEL RETAINER (not shown) 1f ...

[Page 45] Town & Country Fireplaces TC36

1i 1g 1j 1a 1h 1f 2a 2d 2e 2b 2c #2 #1 1c 1b 3 4 1e 1d 2f (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM .......DESCRIPTION ................................................. PART NO. #1 ......... CONTROL ASSEMBLY KIT ...............TCCV.9...

[Page 46] Town & Country Fireplaces TC36

Fig. #78 Wiring Diagram 46 TC36_D & TC36_DAR 030615-48 5056.427D ...

[Page 47] Town & Country Fireplaces TC36

DATE OF MANUFACTURE JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2014 2015 2016 Optional components/ Éléments facultatifs: Powervent Kit/ kit de ventilation mécanique TCVT.PVI.25, TCVT.PV7.110, TCVT.PVCV Blower electrical rating: 115v, 60hz...

[Page 48] Town & Country Fireplaces TC36

© 2015 Copyright Pacic Energy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. Printed in Canada For technical support, please conta...