[Page 1] Pacific energy SUMMIT WOOD INSERT DESIGN-A

160309-20 SUMINSERTA 5055.511 SAFETY NOTICE If this stove is not properly installed, a house re may result. For your safety, folow the installation directions. Consult local building or officials about restrictions and installation in...

[Page 2] Pacific energy SUMMIT WOOD INSERT DESIGN-A

2 SUMINSERTA 160309-20 Contents Safety .............................................................................................. 3 Clearances ...................................................................................... 3 Masonry or...

[Page 3] Pacific energy SUMMIT WOOD INSERT DESIGN-A

SUMINSERTA 160309-20 3 Safety READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING THIS APPLIANCE. FAILURE TO FOLLOW IN- STRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. We strongly recommend that smoke detectors be...

[Page 4] Pacific energy SUMMIT WOOD INSERT DESIGN-A

4 SUMINSERTA 160309-20 16” Non-combustible hearth 34 1/2” 23 1/8” 18” 8”8” *Fireplace Hearth (measured without the insert): The non-combustible replace hearth must be raised 2" above an adjacent combustible oor and extend...

[Page 5] Pacific energy SUMMIT WOOD INSERT DESIGN-A

SUMINSERTA 160309-20 5 Installation Your Insert is designed to be installed into a masonry or factory built zero-clearance replace. The masonry replace must be built according to the requirements of the Standard of Chimneys, Fireplaces...

[Page 6] Pacific energy SUMMIT WOOD INSERT DESIGN-A

6 SUMINSERTA 160309-20 Full Flue Liner - (Required in Canada) 1) Measure the chimney height from the top of the existing ue to the oor of the hearth. This will allow extra length of liner for ashing and rain cap. 2) Feed the stain...

[Page 7] Pacific energy SUMMIT WOOD INSERT DESIGN-A

SUMINSERTA 160309-20 7 Surround Assembly and Installation 1) Lay part A, B and C face down on a at non-marring surface. Fasten together with 1/4" x 1/2" bolts and nuts provided through holes at points “D” (Fig. #5 and 8). 2) ...

[Page 8] Pacific energy SUMMIT WOOD INSERT DESIGN-A

8 SUMINSERTA 160309-20 10) Position the decorative bay stove top onto the rebox top. Ensure that the studs align with the slotted tabs, one on each side of the rebox top. Secure in place with 1/4” nuts provided. 11) Replace the front...

[Page 9] Pacific energy SUMMIT WOOD INSERT DESIGN-A

SUMINSERTA 160309-20 9 Combustion Air Consult local building codes regarding combustion air sup- ply. Intake or combustion air can be supplied to the Insert in one of two ways: 1) Outside air supply: Remove cover from ash clean out in existin...

[Page 10] Pacific energy SUMMIT WOOD INSERT DESIGN-A

10 SUMINSERTA 160309-20 Operation Wood Selection This heater is designed to burn natural wood only. Higher efficiency and lower emissions generally result when burning air-dried seasoned hardwoods, as compared to softwoods or too green or fre...

[Page 11] Pacific energy SUMMIT WOOD INSERT DESIGN-A

SUMINSERTA 160309-20 11 Ash Removal Whenever ashes get 3 to 4 inches deep in your rebox, and when re has burned down and cooled, remove excess ashes. Leave an ash bed approximately 1 inch deep on the rebox bottom to help maint...

[Page 12] Pacific energy SUMMIT WOOD INSERT DESIGN-A

12 SUMINSERTA 160309-20 Chimney Fires The result of excessive creosote buildup is a chimney re. Chimney res are dangerous. Chimney inside temperatures can exceed 2000 degrees F. This causes much higher than normal temperatures in the c...

[Page 13] Pacific energy SUMMIT WOOD INSERT DESIGN-A

SUMINSERTA 160309-20 13 Maintenance 1. Burn wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup ...

[Page 14] Pacific energy SUMMIT WOOD INSERT DESIGN-A

14 SUMINSERTA 160309-20 Appendix A Troubleshooting Problem Cause Cure Excessive Creosote 1) Wood is too wet - Use dry wood Buildup 2) Turning down air control - Do not turn down until: too soon a) there is a good bed of coals ...

[Page 15] Pacific energy SUMMIT WOOD INSERT DESIGN-A

SUMINSERTA 160309-20 15 ITEM SIZE PART NUMBER A 1 1/2” X 4 1/2” X 1 1/4” (39 mm x 115 mm x 32 mm) 248.0 B 4” X 4 1/2” X 1 1/4” (102 mm x 115 mm x 32 mm) 246.0 C 7 1/4” X 4 1/2” X 1 1/4” (184 mm x 115 mm x 32...

[Page 16] Pacific energy SUMMIT WOOD INSERT DESIGN-A

16 SUMINSERTA 160309-20 4......Casing Top, Back ............................................................. 3502 5......Casing Top, Front ........................................................ 3502.51 6......Casing Back..........................

[Page 17] Pacific energy SUMMIT WOOD INSERT DESIGN-A

SUMINSERTA 160309-20 17 6 6 6 Fig. # 18 ...

[Page 18] Pacific energy SUMMIT WOOD INSERT DESIGN-A

18 SUMINSERTA 160309-20 Understanding & Operating Your Pacic Energy Stove The Pacic Energy line of wood stoves is a culmina- tion of years of research and development. Designed to be efficient, clean-burning and user-friendly, this h...

[Page 19] Pacific energy SUMMIT WOOD INSERT DESIGN-A

SUMINSERTA 160309-20 19 Label MINIMUM CLEARANCE TO COMBUSTIBLES (MEASURED FROM INSERT BODY) A) ADJACENT SIDEWALL 216 mm / 8.5 in. B) MANTLE 533 mm / 21 in. C) TOP FACING 533 mm / 21 in. D) SIDE FACING 216 mm / 8.5 in. • INSTALL�...

[Page 20] Pacific energy SUMMIT WOOD INSERT DESIGN-A

PACIFIC ENERGY FIREPLACE PRODUCTS LTD. Technical Support: 1 887 715-2398 www.pacicenergy.net 2975 Allenby Rd., Duncan, B.C. V9L 6V8 Printed in Canada ...