Download or browse on-line these Instruction Manual for A.O. Smith RESIDENTIAL GAS WATER HEATERS Water Heater.
This manual for A.O. Smith RESIDENTIAL GAS WATER HEATERS, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 84 pages, and the size of the file at download is 5.8 Mb. The document type is Instruction Manual.
In case you failed to obtain relevant information in this document, please, look through related operating manuals and user instructions for A.O. Smith RESIDENTIAL GAS WATER HEATERS. Just click one of the links below to go to the selected manual:
Pages: 24
Pages: 60
[Page 1] A.O. Smith RESIDENTIAL GAS WATER HEATERS
1 Instruction Manual PRINTED IN THE U.S.A 0408 197838-000 KEEP THIS MANUAL IN THE POCKET ON HEATER FOR FUTURE REFERENCE WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED. POWER VENT/POWER DIRECT VENT GAS MODELS WITH HOT SURFACE IGNITION ALL ...
[Page 2] A.O. Smith RESIDENTIAL GAS WATER HEATERS
2 SAFE INSTALLATION, USE AND SERVICE Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your ...
[Page 3] A.O. Smith RESIDENTIAL GAS WATER HEATERS
3 GENERAL SAFETY ...
[Page 4] A.O. Smith RESIDENTIAL GAS WATER HEATERS
4 GENERAL SAFETY ...
[Page 5] A.O. Smith RESIDENTIAL GAS WATER HEATERS
5 Thank Youforpurchasingthiswaterheater.Properlyinstalledand maintained,itshouldgiveyouyearsoftroublefreeservice. Abbreviations Found In This Instruction Manual: • CSA-CanadianSta...
[Page 6] A.O. Smith RESIDENTIAL GAS WATER HEATERS
6 * CAUTION HARNESS HAS 120 VAC. IN OPERATION. ** See “Planning the Vent System,” “Installation of Vent System” and “Condensate” for more information. FIGURE 1. VACUUM RELIEF VALVE *INSTALL PER LOCAL CODES M Display Enclosure ...
[Page 7] A.O. Smith RESIDENTIAL GAS WATER HEATERS
7 Rough-In-Dimensions Model Units A B C D E F 100 Inches 68.50 49.25 22.00 15.75 3.00 8.00 cm 174 125.09 55.88 40.00 7.62 20.32 Top/Side Inlet and Outlet: 3/4” NPT Gas Inlet: 1/2” NPT Capacity, Gas and Electrical Characteristics Model Approximate...
[Page 8] A.O. Smith RESIDENTIAL GAS WATER HEATERS
8 Forallsidewallterminated,horizontallyventedpowervent,directvent,andpowerdirectventgasfueledwaterheaters installedineverydwelling,buildingorstructureusedinwholeor...
[Page 9] A.O. Smith RESIDENTIAL GAS WATER HEATERS
9 FIGURE 2. WATER PIPING - MIXING VALVE USAGE This appliance has been design certified as complying with AmericanNationalStandard/CSAStandardforwaterheatersand is considered suitable for: Water (Pot...
[Page 10] A.O. Smith RESIDENTIAL GAS WATER HEATERS
10 FACTS TO CONSIDER ABOUT THE LOCATION Carefully choose an indoor location for the new water heater, because theplacementisaveryimportantconsiderationforthesafetyofthe occupantsinthebuildingandfor�...
[Page 11] A.O. Smith RESIDENTIAL GAS WATER HEATERS
11 inanalcoveorcloset,theentireoormustbecoveredbythepanel. Failuretoheedthiswarningmayresultinarehazard. Minimum clearancesbetween thewater heater andc...
[Page 12] A.O. Smith RESIDENTIAL GAS WATER HEATERS
12 afreeareaofonesquareinchper1000Btu/hr(22cm 2 /kW)ofthe totalinputofallappliancesintheenclosure,butnotlessthan100 squareinches(645cm 2 ). Iftheconned...
[Page 13] A.O. Smith RESIDENTIAL GAS WATER HEATERS
13 CLOSED WATER SYSTEMS Water supplysystemsmay, because ofcode requirementsorsuch conditionsashighlinepressure,amongothers,haveinstalleddevices suchaspressurereducingvalves,ch...
[Page 14] A.O. Smith RESIDENTIAL GAS WATER HEATERS
14 Figures2and10showthetypicalattachmentofthewaterpipingto thewaterheater.Thewaterheaterisequippedwith3/4 inchNPT water connections. NOTE: If using copper tubing, solder tubin...
[Page 15] A.O. Smith RESIDENTIAL GAS WATER HEATERS
15 The temperature-pressure relief valvemust bemanually operatedatleastonceayear,seeFigure28.Cautionshouldbe takentoensurethat(1)nooneisinfrontoforaround�...
[Page 16] A.O. Smith RESIDENTIAL GAS WATER HEATERS
16 SEDIMENT TRAPS Asedimenttrapshallbeinstalledasclosetothegasinletofthewater heateraspracticalatthetimeofwaterheaterinstallation.Thesediment trapshallbeeither�...
[Page 17] A.O. Smith RESIDENTIAL GAS WATER HEATERS
17 FIGURE 15B. U.S. POWER VENT CANADIAN POWER VENT WARNING VENT HOOD(S) MAY BE EXTREMELY HOT DURING OPERATION. WARNING VENT HOOD(S) MAY BE EXTREMELY HOT DURING OPERATION. FIGURE 15A. CAUTION TO PREVENT EXHAUSTING PRODUCTS FROM CIRCULATING TO THE...
[Page 18] A.O. Smith RESIDENTIAL GAS WATER HEATERS
18 FIGURE 15D. U.S. DIRECT VENT CANADIAN DIRECT VENT WARNING VENT HOOD(S) MAY BE EXTREMELY HOT DURING OPERATION. WARNING VENT HOOD(S) MAY BE EXTREMELY HOT DURING OPERATION. FIGURE 15C. CAUTION TO PREVENT EXHAUSTING PRODUCTS FROM CIRCULATING TO T...
[Page 19] A.O. Smith RESIDENTIAL GAS WATER HEATERS
19 PLANNING THE VENT SYSTEM Plantherouteoftheventsystemfromtheexhaustelbowtothe plannedlocationoftheventterminal. 1. Layouttotalventsystemtouseaminimumofventpipe�...
[Page 20] A.O. Smith RESIDENTIAL GAS WATER HEATERS
20 INSTALLATION OF VENT SYSTEM Beforebeginninginstallationofpipingsystemthoroughlyread thesectionofthismanualVENTPIPEPREPARATION. If you are installing your system so that it ven...
[Page 21] A.O. Smith RESIDENTIAL GAS WATER HEATERS
21 INSTALLATION SEQUENCE ForinstallationsintheCityofLosAngeles,CaliforniaCategoryIV PVCPipesuchasthatmanufacturedbyBrownlinePipeCompany, mustbeusedasventpipematerial. C...
[Page 22] A.O. Smith RESIDENTIAL GAS WATER HEATERS
22 INSTALLATION OF VENT SYSTEM, SIDEWALL Withtherouteoftheventingsystemandselectionofmaterialscompleted, asdiscussedinthesectionofthismanualtitledPLANNINGTHEVENT SYSTEM,the...
[Page 23] A.O. Smith RESIDENTIAL GAS WATER HEATERS
23 Thisconcentricventterminationkitmaybeusedwith3or4inchdiameter pipesystems.Whenconnectingtoa4in.diameterpipesystema3x4 incheldsuppliedreduceris...
[Page 24] A.O. Smith RESIDENTIAL GAS WATER HEATERS
24 5. SecureassemblytoroofstructureasshowninFigureEusing fieldsuppliedmetalstrappingorequivalentsupportmaterial. NOTE: Ensure termination height is above the roof surface or anticipated snow l...
[Page 25] A.O. Smith RESIDENTIAL GAS WATER HEATERS
25 8. Operateheaterthrough1heatcycletoensurecombustion-airand ventpipesareproperlyconnectedtoconcentricventtermination connections. FIGURE G. MULTI-CONCENTRIC VENT TERMINATIONS Whentwo�...
[Page 26] A.O. Smith RESIDENTIAL GAS WATER HEATERS
26 VENT PIPE PREPARATION 1. INITIAL PREPARATION. A.)Make sure the solvent cement you are planning to use isdesignedforthespecicapplicationyouareattempting. B.)Knowthephysic...
[Page 27] A.O. Smith RESIDENTIAL GAS WATER HEATERS
27 B. Deburring Useaknife,plasticpipedeburringtool,orfiletoremoveburrsfrom theendofsmalldiameterpipe.Besuretoremoveallburrsfrom aroundtheinsideaswellas�...
[Page 28] A.O. Smith RESIDENTIAL GAS WATER HEATERS
28 CONTROLS AND SWITCHES Thismodelisprovidedwiththreepressureswitches.Theseswitches areessentialtothesafeandproperoperationoftheunit.Allswitches arewiredinseries.Thec...
[Page 29] A.O. Smith RESIDENTIAL GAS WATER HEATERS
29 CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING. POWER VENT WIRING SCHEMATIC - FIGURE 24. THIS WATER HEATER IS POLA...
[Page 30] A.O. Smith RESIDENTIAL GAS WATER HEATERS
30 UP Operating Set Point Status: Heating Menu Help 120 F DN OFF GAS O N WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or ...
[Page 31] A.O. Smith RESIDENTIAL GAS WATER HEATERS
31 The watertemperature iscontrolledusing theTemperature Control onthe Display atthe front of the unit (SeeFigure 1). Thiscontrolutilizesatemperatureprobetodetermine�...
[Page 32] A.O. Smith RESIDENTIAL GAS WATER HEATERS
32 USING THE ELECTRONIC CONTROLLER 1. Overview Interactionwiththewaterheatercontrollerisdonethroughanup,adown,andthreeoperationbuttons.Thesebuttonsareillustratedtothe right.Oper...
[Page 33] A.O. Smith RESIDENTIAL GAS WATER HEATERS
33 3. Adjusting the Operating Set Point The Operating Set Pointofthiswaterheaterdeterminestheregulated temperatureforthewaterinthetank.Thisparameterisadjustedinthe Temperaturemenu.�...
[Page 34] A.O. Smith RESIDENTIAL GAS WATER HEATERS
34 3. Changing the Display Units Thedisplayinterfacetotheheaterhastheoptionofselectingbetween degrees Fahrenheit and degrees Celsius for temperature displays. Thiscanbefoundin�...
[Page 35] A.O. Smith RESIDENTIAL GAS WATER HEATERS
35 ACTION: Togettothecurrentfaultinformationscreen,pressMenu. DISPLAY: ACTION: Press the DOWNbuttontohighlight"currentFault"andpressSelect. DISPLAY: ACTION: Press the DOWNbuttonfor...
[Page 36] A.O. Smith RESIDENTIAL GAS WATER HEATERS
36 FOR YOUR INFORMATION START UP CONDITIONS SMOKE/ODOR Itisnotuncommontoexperienceasmallamountofsmokeand odorduringtheinitialstart-up.Thisisduetoburningoffofoil frommetal�...
[Page 37] A.O. Smith RESIDENTIAL GAS WATER HEATERS
37 VENTING SYSTEM INSPECTION Atleastonceayearavisualinspectionshouldbemadeoftheventing system.Youshouldlookfor: 1.Obstructionswhichcouldcauseimproperventing.Thecombustio...
[Page 38] A.O. Smith RESIDENTIAL GAS WATER HEATERS
38 INSTALLEDINSUITABLEAREA:Toinsuresufcientventilationand combustionairsupply,properclearancesfromthewaterheatermust bemaintained.See“FactstoConsiderAboutLocation�...
[Page 39] A.O. Smith RESIDENTIAL GAS WATER HEATERS
39 LEAKAGE CHECKPOINTS Neverusethiswaterheaterunlessitiscompletelylledwithwater. Topreventdamagetothetank,thetankmustbelledwithwater. Watermustowfrom�...
[Page 40] A.O. Smith RESIDENTIAL GAS WATER HEATERS
40 PROBLEMS NOT ENOUGH HOT WATER 1.)Blowerwillnotrun. a.“ON/OFF”controlswitchturnedoff. Turnswitchtothe“ON”position. b.Blowerunplugged. Plugblowerbackinto�...
[Page 41] A.O. Smith RESIDENTIAL GAS WATER HEATERS
43 Limited Warranty A.O.SmithCorporation,thewarrantor,extendsthefollowingLIMITEDWARRANTYtotheownerofthiswaterheater. 1. THE TANK Iftheglass-linedtankinthiswaterheatershall�...
[Page 42] A.O. Smith RESIDENTIAL GAS WATER HEATERS
44 500TennesseeWaltzParkway,AshlandCity,TN37015 Phone:800-527-1953Fax:800-433-2515 www.hotwater.com ...
[Page 43] A.O. Smith RESIDENTIAL GAS WATER HEATERS
1 Manuel d’instructions IMPRIMÉ AUX É.-U. 0408 197838-000 CONSERVER LE PRÉSENT MANUEL DANS LA POCHETTE PRÉVUE SUR LE CHAUFFE-EAU POUR RÉFÉRENCE ULTÉRIEURE, AU BESOIN, AUX FINS DE RÉGLAGE, D’ENTRETIEN OU DE RÉPARATION. MODÈLES À VENTI...
[Page 44] A.O. Smith RESIDENTIAL GAS WATER HEATERS
2 INSTALLATION, UTILISATION ET ENTRETIEN SÉCURITAIRES Il est très important de veiller à votre sécurité et à celle des autres durant l’installation, l’utilisation et l’entretien du chauffe-eau. De nombreux messages et consignes de sécuri...
[Page 45] A.O. Smith RESIDENTIAL GAS WATER HEATERS
3 SÉCURITÉ GÉNÉRALE ...
[Page 46] A.O. Smith RESIDENTIAL GAS WATER HEATERS
4 SÉCURITÉ GÉNÉRALE ...
[Page 47] A.O. Smith RESIDENTIAL GAS WATER HEATERS
5 Merci d’avoir acheté ce chauffe-eau. Dûment installé et entretenu, il fonctionnera sans ennui pendant des années. Siglesutilisésdansleprésentmanuel: • CSA–Associationcanadiennedenormalisation �...
[Page 48] A.O. Smith RESIDENTIAL GAS WATER HEATERS
6 * ATTENTION : COURANT DE 120 V c.a. DANS LE FAISCEAU DE FILS LORSQUE L’APPAREIL EST EN FONCTION. ** Consulter les sections « Planication du système de ventilation », « Installation du système de ventilation » et « Condensation » po...
[Page 49] A.O. Smith RESIDENTIAL GAS WATER HEATERS
7 ÉLÉMENTS À PRENDRE EN COMPTE POUR L’INSTALLATION DIMENSIONS BRUTES FIGURE 1A Dimensions brutes Modèle Unités A B C D E F 100 po 68,50 49,25 22,00 15,75 3,00 8,00 cm 174 125,09 55,88 40,00 7,62 20,32 Entrée et sortie latérales/sur le dessus...
[Page 50] A.O. Smith RESIDENTIAL GAS WATER HEATERS
8 Danslecasdesinstallationsaugazàventilationhorizontaleforcéeouàventilationdirecte,ouencoreàventilationdirecte forcée,quicommuniquentavecl’extérieuretsontprévue...
[Page 51] A.O. Smith RESIDENTIAL GAS WATER HEATERS
9 FIGURE 2 TUYAUTERIE D’EAU – UTILISATION D’UNE VANNE DE MÉLANGE L’appareil est de conception certifiée conforme à la normeANSI/ CSA (édition courante) visant les chauffe-eau au gaz. I...
[Page 52] A.O. Smith RESIDENTIAL GAS WATER HEATERS
10 POINTS À CONSIDÉRER DANS LE CHOIX DE L’EMPLACEMENT Il convient de choisir avec soin l’emplacement du chauffe-eau pour assurer la sécurité des occupants du bâtiment et maximiser le rendement �...
[Page 53] A.O. Smith RESIDENTIAL GAS WATER HEATERS
11 Toutenégligenceàtenircomptedecetavertissemententraîneun risque d’incendie. Les dégagements minimaux entre le chauffe-eau et tout matériau combustiblesontde0po(0cm)�...
[Page 54] A.O. Smith RESIDENTIAL GAS WATER HEATERS
12 avoirunesurfacelibrede1po 2 par1000Btu/h(22cm 2 /kW)dudébit caloriquetotaldetouslesappareilssetrouvantdansl’espaceclos. Celle-ci ne doit pas être inférieure à 1...
[Page 55] A.O. Smith RESIDENTIAL GAS WATER HEATERS
13 SYSTÈMES EN CIRCUIT FERMÉ Poursatisfaireauxexigencesdescodesoupourremédierauxconditions dans le réseau d’alimentation en eau, par exemple les surpressions, le réseaudedistributiond’eaupeut�...
[Page 56] A.O. Smith RESIDENTIAL GAS WATER HEATERS
14 Lesgures2et10présententleraccordementtypedelatuyauteried’eau auchauffe-eau.Lechauffe-eauestéquipéderaccords3/4poNPT. REMARQUE : Pour les tuyaux en cuivre, souder un adapt...
[Page 57] A.O. Smith RESIDENTIAL GAS WATER HEATERS
15 La soupape dedécharge doit être ouverte manuellement aumoins unefoisparan(g.25).Pendantl’opération,s’assurerquepersonne ne se trouve devant ou près de la sortie de la condui...
[Page 58] A.O. Smith RESIDENTIAL GAS WATER HEATERS
16 COLLECTEURS D’IMPURETÉS Au moment de l’installation, il faut placer un collecteur d’impuretés aussiprèsquepossibledel’entréedegazduchauffe-eau.Lecollecteur peutêtreunraccorden�...
[Page 59] A.O. Smith RESIDENTIAL GAS WATER HEATERS
17 FIGURE 15B VENTILATION FORCÉE – ÉTATS-UNIS VENTILATION FORCÉE – CANADA AVERTISSEMENT LA BOUCHE DE VENTILATION PEUT ÊTRE TRÈS CHAUDE LORSQUE LE CHAUFFE-EAU EST EN MARCHE AVERTISSEMENT LA BOUCHE DE VENTILATION PEUT ÊTRE TRÈS CHAUDE ...
[Page 60] A.O. Smith RESIDENTIAL GAS WATER HEATERS
18 FIGURE 15D VENTILATION DIRECTE – ÉTATS-UNIS VENTILATION DIRECTE – CANADA AVERTISSEMENT LA BOUCHE DE VENTILATION PEUT ÊTRE TRÈS CHAUDE LORSQUE LE CHAUFFE-EAU EST EN MARCHE AVERTISSEMENT LA BOUCHE DE VENTILATION PEUT ÊTRE TRÈS CHAUDE ...
[Page 61] A.O. Smith RESIDENTIAL GAS WATER HEATERS
19 PLANIFICATION DU SYSTÈME DE VENTILATION Planierladispositiondusystèmedeventilationenpartantducoude d’évacuationversl’emplacementprévudelabouchedeventilation. 1. Réduire au�...
[Page 62] A.O. Smith RESIDENTIAL GAS WATER HEATERS
20 AVERTISSEMENT RELATIF À LA CONDENSATION : COMME LE CHAUFFE-EAU CAUSE DE LA CONDENSATION, IL FAUT INSTALLER UN DRAIN À PROXIMITÉ POUR PERMETTRE L’ÉCOULEMENT SÉCURITAIRE DU CONDENSAT. CELUI-CI S’ÉCOULE PAR LE COUDE D�...
[Page 63] A.O. Smith RESIDENTIAL GAS WATER HEATERS
21 SÉQUENCE D’INSTALLATION À LosAngeles, il faut utiliser des tuyaux de ventilation en PVC satisfaisantauxcritèresdelacatégorieIVenvigueurenCalifornie, commeceuxquefa...
[Page 64] A.O. Smith RESIDENTIAL GAS WATER HEATERS
22 INSTALLATION DU SYSTÈME DE VENTILATION – MUR Unefoisletrajetdusystèmedeventilationetlechoixdu matériel établis, conformément à la section « Planification du système de ...
[Page 65] A.O. Smith RESIDENTIAL GAS WATER HEATERS
23 La bouche de ventilation concentrique peut être utilisée avec un système de tuyaux de 3 ou de 4 po. Pour la raccorder à un tuyau de 4po,utiliserunréducteur3x4po(nonfourni)entre�...
[Page 66] A.O. Smith RESIDENTIAL GAS WATER HEATERS
24 5. Fixerl’ensembleàlastructuredutoitàl’aidedebridesdemétal (nonfournies)oud’undispositifdesoutienéquivalent(g.E). REMARQUE : Veiller à ce que la bouche de ...
[Page 67] A.O. Smith RESIDENTIAL GAS WATER HEATERS
25 8. Faire fonctionner le chauffe-eau pendant un cycle pour s’assurer que lestuyaux d’air decombustionet d’éventsont bienraccordésà la bouchedeventilationconcentrique. FIGURE G BOUCHES DE VENTI...
[Page 68] A.O. Smith RESIDENTIAL GAS WATER HEATERS
26 PRÉPARATION DES TUYAUX DE VENTILATION 1. PRÉPARATION INITIALE A. S’assurer que la colle à solvant employée est conçue pour l’application à laquelle elle est destinée. B. Bien connaître les caractéristiques physiques e...
[Page 69] A.O. Smith RESIDENTIAL GAS WATER HEATERS
27 B. Ébavurage Utiliseruncouteau,unoutild’ébavuragepourtuyauxdeplastique ouunelimepourébavurerl’extrémitédestuyauxdepetitdiamètre. Bienébavurertantl’intérieur...
[Page 70] A.O. Smith RESIDENTIAL GAS WATER HEATERS
28 MANOSTATS ET DISPOSITIFS DE CONTRÔLE Ce modèle est muni de trois manostats, qui leur permettent de fonctionnerdefaçon efcace etsécuritaire.Touslesmanostats sont câblésensérie.Dèsque...
[Page 71] A.O. Smith RESIDENTIAL GAS WATER HEATERS
29 ATTENTION AU MOMENT DE L’ENTRETIEN DES COMMANDES, ÉTIQUETEZ TOUS LES FILS AVANT DE LES DÉBRANCHER. DES ERREURS DE CÂBLAGE PEUVENT ENTRAÎNER UN FONCTIONNEMENT INADÉQUAT ET DANGEREUX. S’ASSURER QUE L’APPAREIL FONC...
[Page 72] A.O. Smith RESIDENTIAL GAS WATER HEATERS
30 AVERTISSEMENT : Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort. A. L’appareil n’a pas de veilleu...
[Page 73] A.O. Smith RESIDENTIAL GAS WATER HEATERS
31 Pour régler la température de l’eau, utiliser le bouton de réglage situésurledevantdel’appareil(g.1).Unesondethermiqueévalue la température de l’eau dans le réser...
[Page 74] A.O. Smith RESIDENTIAL GAS WATER HEATERS
32 UTILISATION DE LA COMMANDE ÉLECTRONIQUE 1. Généralités L’interactionavecledispositifdecommandeduchauffe-eausefaitaumoyenduboutonUP(monter),duboutonDN(descendre)etdetrois b...
[Page 75] A.O. Smith RESIDENTIAL GAS WATER HEATERS
33 3. Réglage de la température de consigne Latempérature deconsigne duchauffe-eaudétermine latempérature régulée de l’eau contenue dans le réservoir. Ce paramètre (option Operating...
[Page 76] A.O. Smith RESIDENTIAL GAS WATER HEATERS
34 3. Modification des paramètres d’affichage L’interface d’affichage du chauffe-eau permet de choisir entre les degrés Fahrenheit ou les degrés Celsius pour l’affichage de la temp�...
[Page 77] A.O. Smith RESIDENTIAL GAS WATER HEATERS
35 INTERVENTION Pour afficher l’écran du message d’erreur courant, appuyer sur Menu. AFFICHAGE INTERVENTION AppuyersurleboutonDN pour mettre en évidence l’option Current Fault(erreurcourante)e...
[Page 78] A.O. Smith RESIDENTIAL GAS WATER HEATERS
36 AUTRES RENSEIGNEMENTS SITUATIONS POUVANT SE PRODUIRE À LA MISE EN SERVICE FUMÉE/ODEUR À la première mise en service du chauffe-eau, il n’est pas rare de constaterledégagementd’unepetitequantitédefuméeetd’...
[Page 79] A.O. Smith RESIDENTIAL GAS WATER HEATERS
37 INSPECTION DU SYSTÈME DE VENTILATION Inspecter visuellement le système de ventilation au moins une fois par an, en cherchant la présence : 1. D’obstructionspouvantgênerlaventilation.L’airdeventilationet l’a...
[Page 80] A.O. Smith RESIDENTIAL GAS WATER HEATERS
38 VÉRIFIER L’EMPLACEMENT DU CHAUFFE-EAU : Pour assurer une ventilationetunapportd’airdecombustionadéquats,ilfautrespecter les dégagements prescrits autour du chauffe-eau. Se reporter �...
[Page 81] A.O. Smith RESIDENTIAL GAS WATER HEATERS
39 POINTS DE VÉRIFICATION DES FUITES Ne jamais utiliser le chauffe-eau s’il n’est pas entièrement rempli d’eau,sinon leréservoirrisque d’êtreendommagé.Avantd’ouvrir l’arrivée�...
[Page 82] A.O. Smith RESIDENTIAL GAS WATER HEATERS
40 PROBLÈME EAU CHAUDE INSUFFISANTE 1.) Panne du ventilateur a. Interrupteur marche-arrêt à la position OFF. Mettre l’interrupteur à la position ON. b.Ventilateurdébranché. Rebrancherleventilateursurla...
[Page 83] A.O. Smith RESIDENTIAL GAS WATER HEATERS
43 Garantie limitée A.O.SmithCorporation,legarant,offrelaGARANTIELIMITÉEci-dessousaupropriétaireduchauffe-eau. 1. RÉSERVOIR Si,aucoursdesTROISpremièresannéesquisuiventson...
[Page 84] A.O. Smith RESIDENTIAL GAS WATER HEATERS
44 500TennesseeWaltzParkway,AshlandCity,TN37015 Téléphone : 1 800 527-1953 Télécopieur : 1 800 433-2515 www.hotwater.com ...
Installation instructions manual (12 pages)
Replacement parts list (4 pages)
Manual (8 pages)
Operation & user’s manual (11 pages)
Operation & user’s manual (24 pages)