Panasonic CS-ME10DTEG Service Manual

Download or browse on-line these Service Manual for Panasonic CS-ME10DTEG Air Conditioner.

Panasonic CS-ME10DTEG Manual Information:

This manual for Panasonic CS-ME10DTEG, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 136 pages, and the size of the file at download is . The document type is Service Manual.

Download Manual

This sample of Panasonic CS-ME10DTEG Manual is aimed at the following devices list: CS-E18DKEW, CS-E15DB4EW, CS-E15DTEW, CS-E9DKEW, CS-E15DKEW

More Manuals:

In case you failed to obtain relevant information in this document, please, look through related operating manuals and user instructions for Panasonic CS-ME10DTEG. Just click one of the links below to go to the selected manual:

Summary of Contents:

[Page 1] Panasonic CS-ME10DTEG

© 2006 Matsushita Electric Industrial Co., Ltd. All rights reserved. Unauthorized copying and distribution is a violation of law. INDOOR UNIT CS-ME7DKEG CS-ME10DD3EW CS-ME10DTEG CS-E15DB4EW CS-ME7DKDG CS-E9DKDW CS-E9DKEW CS-E12DKDW CS-E12DKEW CS-E15...

[Page 2] Panasonic CS-ME10DTEG

1 Safety Precautions 3 2 Features 5 2.1. Wall Type 6 2.2. Duct Type 9 2.3. Ceiling Floor Type 12 2.4. Mini-Cassette Type 14 3 Product Specifications 16 3.1. Wall Type 16 3.2. Duct Type 17 3.3. Ceiling Floor Type 18 3.4. Mini-Cass...

[Page 3] Panasonic CS-ME10DTEG

1 Safety Precautions • Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. • Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and main c...

[Page 4] Panasonic CS-ME10DTEG

4. Pb free solder has a higher melting point than standard solder; typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a high temperature soldering iron. In case of the soldering iron with temperature control, please set it to 7...

[Page 5] Panasonic CS-ME10DTEG

• Serviceability − Self diagnosis − Test Run at both Cooling and Heating rated frequency • Built-in drain pump (Cassette and Duct type) − A drain pump is built in. The pipe can rise to 200 mm above the drain outlet. 2 Features • Pro...

[Page 6] Panasonic CS-ME10DTEG

2.1. Wall Type 2.1.1. Remote Control 6 ...

[Page 7] Panasonic CS-ME10DTEG

2.1.2. Indoor Unit 7 ...

[Page 8] Panasonic CS-ME10DTEG

8 ...

[Page 9] Panasonic CS-ME10DTEG

2.2. Duct Type 2.2.1. Remote Control 9 ...

[Page 10] Panasonic CS-ME10DTEG

2.2.2. Indoor Unit 10 ...

[Page 11] Panasonic CS-ME10DTEG

11 ...

[Page 12] Panasonic CS-ME10DTEG

2.3. Ceiling Floor Type 2.3.1. Remote Control 12 ...

[Page 13] Panasonic CS-ME10DTEG

2.3.2. Indoor Unit 13 ...

[Page 14] Panasonic CS-ME10DTEG

2.4. Mini-Cassette Type 2.4.1. Remote Control 14 ...

[Page 15] Panasonic CS-ME10DTEG

2.4.2. Indoor Unit 15 ...

[Page 16] Panasonic CS-ME10DTEG

3 Product Specifications 3.1. Wall Type Model Unit CS-ME7DKEG CS-E9DKEW CS-E12DKEW CS-E15DKEW CS-E18DKEW CS-ME7DKDG CS-E9DKDW CS-E12DKDW CS-E15DKDW CS-E18DKDW Item Wall Type Power Source Outdoor power Single 230V 50Hz Air Volume Cooling m 3 /min (cfm...

[Page 17] Panasonic CS-ME10DTEG

3.2. Duct Type Model Unit CS-ME10DD3EG CS-E15DD3EW CS-E18DD3EW Item Duct Type Power Source Outdoor power Single 230V 50Hz Air Volume Cooling m 3 /min (cfm) High: 7.0 (250) High: 7.8 (280) High: 10.3 (360) Heating m 3 /min (cfm) High: 8.9 (310) High: ...

[Page 18] Panasonic CS-ME10DTEG

3.3. Ceiling Floor Type Model Unit CS-ME10DTEG CS-E15DTEW CS-E18DTEW Item Ceiling Floor Type Power Source Outdoor power Single 230V 50Hz Air Volume Cooling m 3 /min (cfm) High: 9.3 (330) High: 11.7 (410) High: 12.1 (430) Heating m 3 /min (cfm) High: ...

[Page 19] Panasonic CS-ME10DTEG

3.4. Mini-Cassette Type Model Unit CS-E15DB4EW CS-E18DB4EW Item Mini-Cassette Type Power Source Outdoor power Single 230V / 240V, 50Hz Air Volume Cooling m 3 /min (cfm) High: 10.5 (370) High: 11.0 (390) Heating m 3 /min (cfm) High: 10.8 (380) High: 1...

[Page 20] Panasonic CS-ME10DTEG

3.5. Outdoor unit: CU-3E18EBE Outdoor Unit Indoor unit combination Operation mode Capacity (kW) Power input (kW) Current (A) Operation Class (kW) Rating mini - max Rating mini - max CU-3E18EBE One-room Operation 2.2 Cooling 2.20 1.8 - 2.9 0.50 0.34 -...

[Page 21] Panasonic CS-ME10DTEG

4 Dimensions 4.1. Wall Type 21 ...

[Page 22] Panasonic CS-ME10DTEG

22 ...

[Page 23] Panasonic CS-ME10DTEG

4.2. Duct Type 23 ...

[Page 24] Panasonic CS-ME10DTEG

24 ...

[Page 25] Panasonic CS-ME10DTEG

4.3. Ceiling Floor Type 25 ...

[Page 26] Panasonic CS-ME10DTEG

4.4. Mini-Cassette Type 26 ...

[Page 27] Panasonic CS-ME10DTEG

4.5. Outdoor Unit 27 ...

[Page 28] Panasonic CS-ME10DTEG

5 Refrigeration Cycle Diagram 28 ...

[Page 29] Panasonic CS-ME10DTEG

6 Wiring Diagram 6.1. Wall Type 29 ...

[Page 30] Panasonic CS-ME10DTEG

6.2. Duct Type 30 ...

[Page 31] Panasonic CS-ME10DTEG

6.3. Ceiling Floor Type 31 ...

[Page 32] Panasonic CS-ME10DTEG

6.4. Mini-Cassette Type 32 ...

[Page 33] Panasonic CS-ME10DTEG

6.5. Outdoor Unit 33 ...

[Page 34] Panasonic CS-ME10DTEG

7 Electronic Circuit Diagram 34 ...

[Page 35] Panasonic CS-ME10DTEG

Printed Circuit Board CU-3E18EBE 35 ...

[Page 36] Panasonic CS-ME10DTEG

8 Operation Details 8.1. Wall Type 8.1.1. Basic Function Inverter control, which equipped with a microcomputer in determining the most suitable operating mode as time passes, automatically adjusts output power for maximum comfort always. In order to ...

[Page 37] Panasonic CS-ME10DTEG

Table (d): Indoor Air Temperature Shifting 1. Target room temperature shift value (dGetaDst) • To offset the absolute gap between detection temperature with actual room temperature. • The heat exchanger unit’s temperature is different based ...

[Page 38] Panasonic CS-ME10DTEG

1. Operation modes which can be selected using the remote control unit: Automatic, Cooling, Soft Dry, Heating, Fan operation mode. 2. Types of operations modes which can be performed simultaneously • Cooling operation and cooling, Soft Dry or fa...

[Page 39] Panasonic CS-ME10DTEG

8.1.1.3. Cooling Operation 8.1.1.3.1. Thermostat control • Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5°C. • Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setti...

[Page 40] Panasonic CS-ME10DTEG

8.1.1.6. Automatic Operation This mode can be set using remote control and the operation is decided by remote control setting temperature, indoor intake air temperature and outdoor air temperature. During operation mode judgment, indoor fan motor (wi...

[Page 41] Panasonic CS-ME10DTEG

Notes: 8.1.1.7. Indoor Fan Motor Operation A. Basic Rotation Speed (rpm) • Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit) [Cooling, Soft Dry, Fan] Remote Control — — O O O O O — — — Tab (rpm...

[Page 42] Panasonic CS-ME10DTEG

B. Indoor Fan Control i. Indoor fan control operation outline 1. Cooling / Soft Dry 42 ...

[Page 43] Panasonic CS-ME10DTEG

2. Heating ii. Auto Fan Speed 1. Cooling Model No. A No. B No. C Powerful Program CS-ME7DKEG, CS-E9DKEW 1110 1130 1150 CS-E12DKEW 1230 1250 1270 CS-E15DKEW 1300 1320 1340 CS-E18DKEW 1390 1410 1430 Normal Program CS-ME7DKEG, CS-E9DKEW 1050 1070 1090...

[Page 44] Panasonic CS-ME10DTEG

2. Heating Note: a. UP: • If move from Lo, the fan speed will be shifted to Maximum 1,520 rpm. • If move from Maximum, the fan speed no change. • In up zone, 10 rpm is added for every 10 seconds until Maximum 1,520 rpm. b. DOWN: • The ...

[Page 45] Panasonic CS-ME10DTEG

D. Deodorizing Control i. Control condition Control at cooling/soft dry operation and auto fan speed. No Deodorizing Control is performed during ON timer standby operation and during freeze prevention control. ii. Operation The odor status is arrange...

[Page 46] Panasonic CS-ME10DTEG

Horizontal Airflow 1. Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the angles as stated below. For heating mode operation, the angle of the vane depends on the indoor heat exchanger te...

[Page 47] Panasonic CS-ME10DTEG

2. When quiet operation is stopped, operation is shifted to normal operation with previous setting. 3. When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed. 4. When operation mode is changed, quiet operatio...

[Page 48] Panasonic CS-ME10DTEG

8.1.1.11. Powerful Mode Operation When the powerful mode is selected, the internal setting temperature will shift to achieve the setting temperature quickly. (a) Cooling Operation (b) Soft Dry Operation (c) Heating Operation 8.1.1.12. ON Timer Contro...

[Page 49] Panasonic CS-ME10DTEG

8.1.1.14. Auto Restart Control • If there is a power failure, operation will automatically be restarted when the power is resumed. It will start with the previous operation mode and airflow direction. (Timer Delay Safety Control is valid.) 1. Con...

[Page 50] Panasonic CS-ME10DTEG

8.1.1.16. Auto Operation Switch 1. When the switch is pressed between 0 to 5 seconds, Auto Mode operation starts to function. 2. When the switch is pressed between 5 to 8 seconds, the unit is forced to operate in Cooling Mode. 3. When the switch i...

[Page 51] Panasonic CS-ME10DTEG

b. Operation Mode + Ionizer Operation. 1. Ionising Operation Start Condition When air conditioner unit is in “ON” condition (Heat, Cool, Dry, Fan, Auto mode) and an ION operation button at remote control is pressed. Ionizer on & ION LED illu...

[Page 52] Panasonic CS-ME10DTEG

8.1.1.17.2. Ionizer Operation case study Case 1 8.1.2. Freeze Prevention Control 1. When indoor heat exchanger temperature is lower than 2°C continuously for six minutes, compressor will stop operating. 2. Compressor will resume its operation thre...

[Page 53] Panasonic CS-ME10DTEG

1. Operation modes which can be selected using the remote control unit: Automatic, Cooling, Soft Dry, Heating, Fan operation mode. 2. Types of operations modes which can be performed simultaneously • Cooling operation and cooling, Soft Dry or fa...

[Page 54] Panasonic CS-ME10DTEG

8.2.2. Indoor Fan Control • The following shows how fan speed changes depending on the setting made with the FAN SPEED button and other operating conditions. • Actual fan speed may differ from that you set with remote control. 54 ...

[Page 55] Panasonic CS-ME10DTEG

8.2.3. Drain Pump Control Basic operation • The drain pump starts 50 seconds after the indoor unit starts or the thermostat comes on (i.e., 10 seconds after the fan motor starts). The drain pump stops 30 seconds after the indoor unit stops or the ...

[Page 56] Panasonic CS-ME10DTEG

8.2.4. Auto Restart Control • If there is a power failure, operation will automatically be restarted when the power is resumed. It will start with the previous operation mode and airflow direction. (Timer Delay Safety Control is valid.) 1. Contro...

[Page 57] Panasonic CS-ME10DTEG

8.2.5. Other Indoor Unit Operation Functions 8.2.5.1. Auto button Proceed with operation when the air conditioner is stopped. (When the auto button is pressed during operation, the air conditioner is stopped.) 1. Emergency operation Press the auto b...

[Page 58] Panasonic CS-ME10DTEG

• Under various setting mode, after select the transmission code combination of remote control, press any button of remote control to transmit a signal to indoor unit. The transmission code will be stored in EEPROM. • After signal is received, ...

[Page 59] Panasonic CS-ME10DTEG

8.3. Ceiling Floor Type 8.3.1. Basic Function Inverter control, which equipped with a microcomputer in determining the most suitable operating mode as time passes, automatically adjusts output power for maximum comfort always. In order to achieve the...

[Page 60] Panasonic CS-ME10DTEG

Table (d): Indoor Air Temperature Shifting 1. Target room temperature shift value (dGetaDst) • To offset the absolute gap between detection temperature with actual room temperature. • The heat exchanger unit’s temperature is different based ...

[Page 61] Panasonic CS-ME10DTEG

1. Operation modes which can be selected using the remote control unit: Automatic, Cooling, Soft Dry, Heating, Fan operation mode. 2. Types of operations modes which can be performed simultaneously • Cooling operation and cooling, Soft Dry or fa...

[Page 62] Panasonic CS-ME10DTEG

8.3.1.3. Cooling Operation 8.3.1.3.1. Thermostat control • Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5°C. • Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setti...

[Page 63] Panasonic CS-ME10DTEG

8.3.1.6. Automatic Operation This mode can be set using remote control and the operation is decided by remote control setting temperature, indoor intake air temperature and outdoor air temperature. During operation mode judgment, indoor fan motor (wi...

[Page 64] Panasonic CS-ME10DTEG

8.3.1.7. Indoor Fan Motor Operation A. Basic Rotation Speed (rpm) • Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit) [Cooling, Soft Dry, Fan] Remote Control — — O O O O O — — — Tab (rpm) PSHi ...

[Page 65] Panasonic CS-ME10DTEG

B. Indoor Fan Control i. Indoor fan control operation outline 1. Cooling / Soft Dry 65 ...

[Page 66] Panasonic CS-ME10DTEG

2. Heating ii. Auto Fan Speed 1. Cooling Model No. A No. B No. C Powerful Program CS-ME10DTEG 790 810 830 CS-E15DTEW 940 960 980 CS-E18DTEW 990 1010 1030 Normal Program CS-ME10DTEG 730 750 770 CS-E15DTEW 880 900 920 CS-E18DTEW 930 950 970 Quiet Pro...

[Page 67] Panasonic CS-ME10DTEG

2. Heating Note: a. UP: • If move from Lo, the fan speed will be shifted to Maximum 1,520 rpm. • If move from Maximum, the fan speed no change. • In up zone, 10 rpm is added for every 10s until Maximum 1,520 rpm. b. DOWN: • The fan spe...

[Page 68] Panasonic CS-ME10DTEG

8.3.1.8. Airflow Direction 1. There is one type of airflow, vertical airflow (directed by horizontal vane). 2. Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat exchanger temperature and intake...

[Page 69] Panasonic CS-ME10DTEG

8.3.1.9. Quiet operation (Cooling Mode/Cooling area of Soft Dry Mode) A. Purpose To provide quiet cooling operation compare to normal operation. B. Control condition a. Quiet operation start condition • When “quiet” button at remote control is...

[Page 70] Panasonic CS-ME10DTEG

C. Control contents a. Fan Speed manual 1. Fan speed is changed from normal setting to quiet setting of respective fan speed. This is to reduce sound of Hi, Me, Lo for 3dB. 2. Fan speed for quiet operation is -1 step from setting fan speed. 3. Fan...

[Page 71] Panasonic CS-ME10DTEG

8.3.1.13. OFF Timer Control OFF timer can be set using remote control, the unit with timer set will stop operate at set time. 8.3.1.14. Auto Restart Control 1. When the power supply is cut off during the operation of air conditioner, the compressor ...

[Page 72] Panasonic CS-ME10DTEG

8.3.1.17. Freeze Prevention Control 1. When indoor heat exchanger temperature is lower than 2°C continuously for six minutes, compressor will stop operating. 2. Compressor will resume its operation three minutes after the indoor heat exchanger is ...

[Page 73] Panasonic CS-ME10DTEG

8.4. Mini-Cassette Type 8.4.1. Basic Function Inverter control, which equipped with a microcomputer in determining the most suitable operating mode as time passes, automatically adjusts output power for maximum comfort always. In order to achieve the...

[Page 74] Panasonic CS-ME10DTEG

Table (d): Indoor Air Temperature Shifting 1. Target room temperature shift value (dGetaDst) • To offset the absolute gap between detection temperature with actual room temperature. • The heat exchanger unit’s temperature is different based ...

[Page 75] Panasonic CS-ME10DTEG

1. Operation modes which can be selected using the remote control unit: Automatic, Cooling, Soft Dry, Heating, Fan operation mode. 2. Types of operations mode which can be performed simultaneously • Cooling operation and cooling, Soft Dry or fan...

[Page 76] Panasonic CS-ME10DTEG

8.4.1.3. Cooling Operation 8.4.1.3.1. Thermostat control • Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5°C. • Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setti...

[Page 77] Panasonic CS-ME10DTEG

8.4.1.6. Automatic Operation This mode can be set using remote control and the operation is decided by remote control setting temperature, indoor intake air temperature and outdoor air temperature. During operation mode judgment, indoor fan motor (wi...

[Page 78] Panasonic CS-ME10DTEG

8.4.1.7. Indoor Fan Motor Operation A. Basic Rotation Speed (rpm) • Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit) [Cooling, Soft Dry, Fan] Remote Control — — O O O O O — — — Tab (rpm) PSHi ...

[Page 79] Panasonic CS-ME10DTEG

B. Indoor Fan Control i. Indoor fan control operation outline 1. Cooling / Soft Dry 79 ...

[Page 80] Panasonic CS-ME10DTEG

2. Heating ii. Auto Fan Speed 1. Cooling Model No. A No. B No. C Powerful Program CS-E15DB4EW 540 560 580 CS-E18DB4EW 605 625 645 Normal Program CS-E15DB4EW 480 500 520 CS-E18DB4EW 545 565 585 Quiet Program CS-E15DB4EW 460 480 500 CS-E18DB4EW 525 5...

[Page 81] Panasonic CS-ME10DTEG

2. Heating Note: a. UP: • If move from Lo, the fan speed will be shifted to Maximum 1,520 rpm. • If move from Maximum, the fan speed no change. • In up zone, 10 rpm is added for every 10s until Maximum 1,520 rpm. b. DOWN: • The fan spe...

[Page 82] Panasonic CS-ME10DTEG

D. Deodorizing Control i. Control condition Control at cooling/soft dry operation and auto fan speed setting. No Deodorizing Control is performed during ON timer standby operation and during freeze prevention control. ii. Operation The odor status is...

[Page 83] Panasonic CS-ME10DTEG

8.4.1.9. Quiet operation (Cooling Mode/Cooling area of Soft Dry Mode) A. Purpose To provide quiet cooling operation compare to normal operation. B. Control condition a. Quiet operation start condition • When “quiet” button at remote control is...

[Page 84] Panasonic CS-ME10DTEG

b. Quiet operation stop condition 1. When one of the following conditions is satisfied, quiet operation stops: a. Powerful button is pressed. b. Stop by OFF/ON switch. c. Timer “off” activates. d. Quiet button is pressed again. 2. When quie...

[Page 85] Panasonic CS-ME10DTEG

8.4.1.12. ON Timer Control ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time. This is to provide a comfortable environment when reaching the set ON time. 60 minutes before the set time,...

[Page 86] Panasonic CS-ME10DTEG

4. When the switch is pressed between 11 to 16 seconds and together with the signal from remote control (timer decrement button for 5s), the unit can be changed to different controlling setting (4 type of transmission codes). 5. When the switch is ...

[Page 87] Panasonic CS-ME10DTEG

8.5. Outdoor Unit Operation 8.5.1. Room Temperature Control 8.5.1.1. Cooling, Soft Dry and Heating Operations 1. Immediately after the compressor has started up during an ongoing operation, the initial frequency is determined on the basis of the inf...

[Page 88] Panasonic CS-ME10DTEG

• Forced cooling operations can be performed by the outdoor unit. 1. Set the operation mode setting switch (SW2) to COOL. 2. The forced cooling operation is performed when the forced operation switch (SW1) is pressed. * The forced cooling operat...

[Page 89] Panasonic CS-ME10DTEG

The useful wiring error check function automatically corrects wiring errors using a microcomputer. In cases where wires are embedded or the locations of connecting wires are not known for other reasons, for instance, pressing the wiring error check s...

[Page 90] Panasonic CS-ME10DTEG

8.8. Outdoor Unit - Check Point 90 ...

[Page 91] Panasonic CS-ME10DTEG

• Once abnormality has been detected during operation, the unit will immediately stop its operation. (Timer LED blinks.) • Although timer LED goes off when power supply is turned off, if the unit is operated under a breakdown condition, the LED...

[Page 92] Panasonic CS-ME10DTEG

9.2. Error Code Symbol Diagnosis Diagnosis method H11 Indoor / Outdoor abnormal communication This error occurs when indoor/outdoor unit communication fails to be established after 30 seconds or more. <Diagnosis checkpoint> 1. Measure the volt...

[Page 93] Panasonic CS-ME10DTEG

Symbol Diagnosis Diagnosis method H30 Outdoor discharge pipe temp. sensor Disconnected discharge sensor • When the condensation temperature is higher than the discharge temperature + (plus) 6°C, a sensor disconnection is detected, operation stops...

[Page 94] Panasonic CS-ME10DTEG

Symbol Diagnosis Diagnosis method H99 Indoor operating unit freezing The restriction on the compressor frequency is started when the indoor unit heat exchanger temperature is between 8°C and 12°C. Operation stops if a temperature below 0°C continu...

[Page 95] Panasonic CS-ME10DTEG

Symbol Diagnosis Diagnosis method F97 Compressor high discharge temperature This error occurs and operation stops when this happens on 6 occasions (it is cleared when the operation is normal for 20 minutes). <Diagnosis checkpoint> 1. Check the...