Siemens SINAMICS G120C Operating Instructions Manual

Download or browse on-line these Operating Instructions Manual for Siemens SINAMICS G120C Control Panel, DC Drives.

Siemens SINAMICS G120C Manual Information:

This manual for Siemens SINAMICS G120C, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 422 pages, and the size of the file at download is . The document type is Operating Instructions Manual.

Download Manual

More Manuals:

In case you failed to obtain relevant information in this document, please, look through related operating manuals and user instructions for Siemens SINAMICS G120C. Just click one of the links below to go to the selected manual:

Summary of Contents:

[Page 1] Siemens SINAMICS G120C

...

[Page 2] Siemens SINAMICS G120C

s Product information 07/2015 Additional requirements for Branch Circuit Protection The following information is additional information regarding the specific details of the requirements for Branch Circuit Protection for the SINAMICS G120C con...

[Page 3] Siemens SINAMICS G120C

SINAMICS G120C 2 Product information, Edition 07/2015 Table 2: Branch circuit protection with non-semiconductor fuses Class J, T, CC, G, CF (JDDZ) Frame size Rated power Drive Max. rated current of the fuse Short-circuit current rating (...

[Page 4] Siemens SINAMICS G120C

3 SINAMICS G120C Product information, Edition 07/2015 Table 4: Branch circuit protection with Type E combination motor controllers (NKJH) Frame size Rated power Drive CMC model no. * Max. rated current of the CMC Rated power...

[Page 5] Siemens SINAMICS G120C

s Product information 07/2015 Modified behavior when commissioning the drive With firmware V4.7 SP3, the commissioning Wizard has been revised and standardized for the following inverters: • SINAMICS G120 with PM240, PM240-2 or PM330 P...

[Page 6] Siemens SINAMICS G120C

...

[Page 7] Siemens SINAMICS G120C

SINAMICS G120C converter ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ _________________...

[Page 8] Siemens SINAMICS G120C

Siemens AG Division Digital Factory Postfach 48 48 90026 NÜRNBERG GERMANY A5E34263257B AC Ⓟ 08/2015 Subject to change Copyright © Siemens AG 2011 - 2015. All rights reserved Legal information Warning notice...

[Page 9] Siemens SINAMICS G120C

SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 5 Change history The most important changes with respect to the 04/2015 edition of the manual New hardware In Chapter New inverter frame si...

[Page 10] Siemens SINAMICS G120C

Change history SINAMICS G120C converter 6 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC ...

[Page 11] Siemens SINAMICS G120C

SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 7 Table of contents Change history ...................................................................................................................

[Page 12] Siemens SINAMICS G120C

Table of contents SINAMICS G120C converter 8 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 4.8.10 Monitoring the temperature of the braking resistor ................................................................ 81 4.8.1...

[Page 13] Siemens SINAMICS G120C

Table of contents SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 9 6.2.10.4 Extend telegrams and change signal interconnection .......................................................... 161 6.2.10.5 ...

[Page 14] Siemens SINAMICS G120C

Table of contents SINAMICS G120C converter 10 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 6.7.6 Automatic restart ..............................................................................................................

[Page 15] Siemens SINAMICS G120C

Table of contents SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 11 8.2.3 Correcting an unsuccessful firmware upgrade or downgrade .............................................. 331 8.3 Reduced accep...

[Page 16] Siemens SINAMICS G120C

Table of contents SINAMICS G120C converter 12 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC A.5 Interconnecting signals in the converter .............................................................................. 399 A....

[Page 17] Siemens SINAMICS G120C

SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 13 Fundamental safety instructions 1 1.1 General safety instructions DANGER Danger to life due to live parts and other energy sources ...

[Page 18] Siemens SINAMICS G120C

Fundamental safety instructions 1.1 General safety instructions SINAMICS G120C converter 14 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC WARNING Danger to life when live parts are touched on damaged devices Improper h...

[Page 19] Siemens SINAMICS G120C

Fundamental safety instructions 1.1 General safety instructions SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 15 WARNING Danger to life through unexpected movement of machines when using mobile w...

[Page 20] Siemens SINAMICS G120C

Fundamental safety instructions 1.1 General safety instructions SINAMICS G120C converter 16 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC NOTICE Device damage caused by incorrect voltage/insulation tests Incorrect volt...

[Page 21] Siemens SINAMICS G120C

Fundamental safety instructions 1.2 Safety instructions for electromagnetic fields (EMF) SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 17 1.2 Safety instructions for electromagnetic fields (EMF) ...

[Page 22] Siemens SINAMICS G120C

Fundamental safety instructions 1.4 Industrial security SINAMICS G120C converter 18 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 1.4 Industrial security Note Industrial security Siemens provides products and s...

[Page 23] Siemens SINAMICS G120C

Fundamental safety instructions 1.5 Residual risks of power drive systems SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 19 1.5 Residual risks of power drive systems The control and drive compon...

[Page 24] Siemens SINAMICS G120C

Fundamental safety instructions 1.5 Residual risks of power drive systems SINAMICS G120C converter 20 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 3. Hazardous shock voltages caused by, for example, – Component failure ...

[Page 25] Siemens SINAMICS G120C

SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 21 Introduction 2 2.1 About the Manual Who requires the operating instructions and what for? These operating instructions primarily address fitt...

[Page 26] Siemens SINAMICS G120C

Introduction 2.2 Guide through the manual SINAMICS G120C converter 22 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 2.2 Guide through the manual Section In this section you will find answers to the following quest...

[Page 27] Siemens SINAMICS G120C

Introduction 2.2 Guide through the manual SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 23 Section In this section you will find answers to the following questions: Technical data (Page 355) •...

[Page 28] Siemens SINAMICS G120C

Introduction 2.2 Guide through the manual SINAMICS G120C converter 24 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC ...

[Page 29] Siemens SINAMICS G120C

SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 25 Description 3 Use for the intended purpose The inverter described in this manual is a device to control a three-phase motor. The inverter i...

[Page 30] Siemens SINAMICS G120C

Description 3.1 Scope of delivery SINAMICS G120C converter 26 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Rating plate and technical data The rating plate contains the Article No. and the hardware and firmware ver...

[Page 31] Siemens SINAMICS G120C

Description 3.2 Optional components for the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 27 3.2 Optional components for the inverter Braking resistor The braking resistor allows the ...

[Page 32] Siemens SINAMICS G120C

Description 3.3 Motor series that are supported SINAMICS G120C converter 28 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 3.3 Motor series that are supported Supported motors The inverter is designed for the following...

[Page 33] Siemens SINAMICS G120C

Description 3.3 Motor series that are supported SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 29 Some restrictions apply for operation: Table 3- 2 Restrictions for operation with encoderless synchro...

[Page 34] Siemens SINAMICS G120C

Description 3.4 Tools to commission the converter SINAMICS G120C converter 30 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 3.4 Tools to commission the converter The following tools are used to commission, troubleshoot...

[Page 35] Siemens SINAMICS G120C

SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 31 Installing 4 4.1 Procedure for installing the converter Prerequisites for installing the converter Check that the following prerequisites are...

[Page 36] Siemens SINAMICS G120C

Installing 4.2 EMC-compliant installation SINAMICS G120C converter 32 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 4.2 EMC-compliant installation 4.2.1 EMC-compliant cabinet design The most cost-effective method ...

[Page 37] Siemens SINAMICS G120C

Installing 4.2 EMC-compliant installation SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 33 connection. Ensure that there are no potential differences between these zones, to avoid inadmissibly high e...

[Page 38] Siemens SINAMICS G120C

Installing 4.2 EMC-compliant installation SINAMICS G120C converter 34 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC ● Route the cables as close as possible to grounded enclosure parts such as mounting plates or the cabine...

[Page 39] Siemens SINAMICS G120C

Installing 4.2 EMC-compliant installation SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 35 Measures for high frequency equipotential bonding Proceed as follows, to ensure high-frequency equipotenti...

[Page 40] Siemens SINAMICS G120C

Installing 4.2 EMC-compliant installation SINAMICS G120C converter 36 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Diagrams for grounding and high-frequency equipotential bonding measures The following diagram illustrates...

[Page 41] Siemens SINAMICS G120C

Installing 4.2 EMC-compliant installation SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 37 The following diagram shows the additional measures for high-frequency equipotential bonding Figure 4-2 ...

[Page 42] Siemens SINAMICS G120C

Installing 4.2 EMC-compliant installation SINAMICS G120C converter 38 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 4.2.2 Installing the converter in compliance with EMC rules Overview EMC -compliant wiring sho...

[Page 43] Siemens SINAMICS G120C

Installing 4.3 Installing the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 39 4.3 Installing the inverter Mounting orientation Mount the converter in a control cabinet. Figure 4...

[Page 44] Siemens SINAMICS G120C

Installing 4.3 Installing the inverter SINAMICS G120C converter 40 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Table 4- 1 Dimensions Frame Size AA 0.55 kW … 1.5 kW Frame Size A 0.55 kW … 4.0 kW Frame size ...

[Page 45] Siemens SINAMICS G120C

Installing 4.3 Installing the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 41 Mounting on a control cabinet panel Table 4- 2 Drilling patterns and mounting equipment Frame Size AA 0.55...

[Page 46] Siemens SINAMICS G120C

Installing 4.3 Installing the inverter SINAMICS G120C converter 42 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Mounting on a mounting rail (TS 35) You can mount inverters, frame size FSAA on a TS 35 mounting rai...

[Page 47] Siemens SINAMICS G120C

Installing 4.3 Installing the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 43 Mounting on a base component (only frame size FSAA) Reactors, filters and braking resistors are available as ...

[Page 48] Siemens SINAMICS G120C

Installing 4.4 Mounting base components SINAMICS G120C converter 44 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 4.4 Mounting base components Dimensions Line reactor as base component, 0.55 kW … 1.5 kW Moun...

[Page 49] Siemens SINAMICS G120C

Installing 4.4 Mounting base components SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 45 Output reactor as base component, 0.55 kW … 1.5 kW Mounting: 4 × M4 screws 4 × M4 nuts 4 × M4 w...

[Page 50] Siemens SINAMICS G120C

Installing 4.4 Mounting base components SINAMICS G120C converter 46 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Braking resistor as base component, 0.55 kW … 1.5 kW Mounting: 4 × M4 screws 4 × M4 nuts 4 × M4...

[Page 51] Siemens SINAMICS G120C

Installing 4.5 Mounting the line reactor SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 47 4.5 Mounting the line reactor Mounting position Clearances to other devices For a line reactor,...

[Page 52] Siemens SINAMICS G120C

Installing 4.5 Mounting the line reactor SINAMICS G120C converter 48 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Dimensions and drilling patterns 0.55 kW … 1.1 kW Dimensions [mm] Drilling pattern [mm] ...

[Page 53] Siemens SINAMICS G120C

Installing 4.5 Mounting the line reactor SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 49 5 .5 kW … 7.5 kW 11 kW … 18.5 kW 67.5 Fixings: 4 x M5 bolts 4 x M5 nuts 4 x M5 washers T...

[Page 54] Siemens SINAMICS G120C

Installing 4.6 Mounting the output reactor SINAMICS G120C converter 50 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 4.6 Mounting the output reactor Mounting position Clearances to other devices Keep shaded areas...

[Page 55] Siemens SINAMICS G120C

Installing 4.6 Mounting the output reactor SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 51 Dimensions and drilling patterns 0.55 kW … 2.2 kW Dimensions [mm] Drilling pattern [mm] ...

[Page 56] Siemens SINAMICS G120C

Installing 4.6 Mounting the output reactor SINAMICS G120C converter 52 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 5.5 kW … 7.5 kW Dimensions [mm] Drilling pattern [mm] 11 kW … 18.5 kW Dimensions [...

[Page 57] Siemens SINAMICS G120C

Installing 4.7 Mounting the braking resistor SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 53 4.7 Mounting the braking resistor Mounting position CAUTION Risk of burns due to touchi...

[Page 58] Siemens SINAMICS G120C

Installing 4.7 Mounting the braking resistor SINAMICS G120C converter 54 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Clearances to other devices Figure 4-12 Minimum clearances for the braking resistor when mounting ...

[Page 59] Siemens SINAMICS G120C

Installing 4.7 Mounting the braking resistor SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 55 Frame size A, 2.2 kW … 4.0 kW Dimensions [mm] Drilling pattern [mm] Fixing: 4 × M4 screw...

[Page 60] Siemens SINAMICS G120C

Installing 4.7 Mounting the braking resistor SINAMICS G120C converter 56 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Frame size C, 11 kW … 18.5 kW Dimensions [mm] Drilling pattern [mm] Fixing: 4 × M5 screw...

[Page 61] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 57 4.8 Connecting the inverter 4.8.1 Permissible line supplies The inverter is designed for the followi...

[Page 62] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 58 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC TT system In a TT line system, the transformer grounding and the installation grounding are independent of o...

[Page 63] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 59 IT system In an IT line system, all of the conductors are insulated with respect to the PE protective conduc...

[Page 64] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 60 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 4.8.2 Connecting the inverter and inverter components to the supply WARNING Danger to life caused...

[Page 65] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 61 Procedure To connect the inverter and its components, proceed as follows: 1. Install the appropr...

[Page 66] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 62 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Installation in the United States and Canada (UL or CSA) To install the inverter in compliance with UL/cUL, p...

[Page 67] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 63 4.8.3 Connecting the motor Connecting a motor using a star or delta connection With SIEMENS motors, y...

[Page 68] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 64 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 4.8.4 Operating a converter on the residual current device WARNING Live enclosure parts due to un...

[Page 69] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 65 4.8.5 Overview of the interfaces To access the interfaces at the front of the Control Unit, you must lift...

[Page 70] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 66 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 4.8.6 Fieldbus interface assignment The fieldbus interface is on the underside of the converter. ...

[Page 71] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 67 4.8.7 Terminal strips Wiring variations of the terminal strips All terminals with the reference pote...

[Page 72] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 68 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Further wiring options for digital inputs Connection of contacts switching to P potential with an extern...

[Page 73] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 69 Factory settings of the terminal strip The factory setting of the terminals depends on whether the inverter h...

[Page 74] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 70 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Figure 4-18 Factory setting of the terminals for G120C DP and G120C PN Changing the function of the termina...

[Page 75] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 71 4.8.8 Default setting of the interfaces Default setting 1: "Conveyor technology with 2 fixed frequenc...

[Page 76] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 72 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Default setting 3: "Conveyor system with 4 fixed frequencies" DO 0: p0730, DO 1: p0731 AO 0: p...

[Page 77] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 73 Default setting 5: "Conveyor system with fieldbus and Basic Safety" DO 0: p0730, DO 1: p0731 A...

[Page 78] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 74 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Default setting 8: "MOP with Basic Safety" DO 0: p0730, DO 1: p0731 AO 0: p0771[0] DI 0: r07...

[Page 79] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 75 Default setting 12: "Standard I/O with analog setpoint" Factory setting for inverters with USS inte...

[Page 80] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 76 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Default setting 14: "Process industry with fieldbus" DO 0: p0730, DO 1: p0731 AO 0: p0771[0] ...

[Page 81] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 77 Default setting 15: "Process industry" DO 0: p0730, DO 1: p0731 AO 0: p0771[0] DI 0: r0722.0...

[Page 82] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 78 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Default setting 18: "2-wire (forw/backw2)" DO 0: p0730, DO 1: p0731 AO 0: p0771[0] DI 0: r07...

[Page 83] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 79 Default setting 21: "USS fieldbus" DO 0: p0730, DO 1: p0731 AO 0: p0771[0] DI 2: r0722.2 S...

[Page 84] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 80 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 4.8.9 Wiring the terminal strip NOTICE Damage to the inverter when using long signal cables Usi...

[Page 85] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 81 Wiring the terminal strip to ensure EMC ● If you use shielded cables, you must connect the shield to the m...

[Page 86] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 82 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 4.8.11 Connecting the inverter to the fieldbus 4.8.11.1 Communication interfaces Fieldbus interfaces ...

[Page 87] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 83 4.8.11.2 PROFINET You can either communicate via Ethernet using the inverter, or integrate the inverter i...

[Page 88] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 84 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Further information on PROFINET can be found on the Internet using the following links: – General informatio...

[Page 89] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 85 Configuring communication to the control Configuring the communication using SIMATIC S7 control You have the...

[Page 90] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 86 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 4.8.11.3 PROFIBUS What do you need for communication via PROFIBUS? Check the communication settings usin...

[Page 91] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 87 Communication with the control, even when the line voltage is switched off If, in your plant or system, comm...

[Page 92] Siemens SINAMICS G120C

Installing 4.8 Connecting the inverter SINAMICS G120C converter 88 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 3. Wait until all LEDs on the inverter go dark. 4. Switch on the inverter supply voltage again. Your setting...

[Page 93] Siemens SINAMICS G120C

SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 89 Commissioning 5 5.1 Commissioning guidelines Overview 1. Define the requirements of your application placed on the drive. → (...

[Page 94] Siemens SINAMICS G120C

Commissioning 5.2 Preparing for commissioning SINAMICS G120C converter 90 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 5.2 Preparing for commissioning 5.2.1 Collecting motor data Before starting commissioning, yo...

[Page 95] Siemens SINAMICS G120C

Commissioning 5.2 Preparing for commissioning SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 91 5.2.2 Inverter factory setting Motor With its factory settings, the inverter is set up for an ind...

[Page 96] Siemens SINAMICS G120C

Commissioning 5.2 Preparing for commissioning SINAMICS G120C converter 92 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Switching the motor on and off in the jog mode In the case of inverters with a PROFIBUS or PROFINET in...

[Page 97] Siemens SINAMICS G120C

Commissioning 5.3 Commissioning using a BOP-2 operator panel SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 93 5.3 Commissioning using a BOP-2 operator panel Plug Basic Operator Panel BOP-2 into ...

[Page 98] Siemens SINAMICS G120C

Commissioning 5.3 Commissioning using a BOP-2 operator panel SINAMICS G120C converter 94 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC Select the suitable application class When you select an application class, the inverte...

[Page 99] Siemens SINAMICS G120C

Commissioning 5.3 Commissioning using a BOP-2 operator panel SINAMICS G120C converter Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 95 5.3.2 Standard Drive Control 6. Motor standard KW 50HZ IEC H...

[Page 100] Siemens SINAMICS G120C

Commissioning 5.3 Commissioning using a BOP-2 operator panel SINAMICS G120C converter 96 Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC 8.9. Motor cooling SELF Natural cooling FORCED Forced-ai...