[Page 1] pyrexx RWM MC

RWM MC Diagnosegerät für Rauchwarnmelder Diagnostic device for smoke alarm devices Betriebsanleitung Operating Manual ...

[Page 2] pyrexx RWM MC

3 Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder DE 2 DE EN 1 Hinweise zur Betriebsanleitung Wir freuen uns, dass Sie sich für unser Produkt entschieden haben und danken Ihnen für Ihr Vertrauen! Die vorliegende Betriebsanl...

[Page 3] pyrexx RWM MC

4 5 Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder DE DE 1.8 Haftungsausschluss Abgesehen von der gesetzlichen Gewährleistung übernimmt die Pyrexx Technologi...

[Page 4] pyrexx RWM MC

6 7 Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder DE DE 2.5 Grundsätzliche Sicherheitshinweise Die grundsätzlichen Sicherheitshinweise fassen alle Maßnahme...

[Page 5] pyrexx RWM MC

8 9 Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder DE DE 1 Anschlussbuchse für RJ-Stecker 2 Display 3 Adapterkabel 4 Start-Taste 5 Dreieckstecker mit Schutz...

[Page 6] pyrexx RWM MC

10 11 Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder DE DE Anschlussbuchse für RJ-Stecker In die Anschlussbuche wird der RJ-Stecker des Adapterkabels eingesteck...

[Page 7] pyrexx RWM MC

12 13 Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder DE DE (1) Sicherstellen, dass das RWM MC und der Rauchwarnmelder einge- schaltet sind f Betriebsanleitung ...

[Page 8] pyrexx RWM MC

14 15 Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder DE DE Wenn kein Rauchwarnmelder ange- schlossen ist, erhalten Sie die Meldung „FEHLER Verbindung fehlgesc...

[Page 9] pyrexx RWM MC

16 17 Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder DE DE Batteriealarm Ein Batteriealarm wird bei einer schwachen Batterie des Rauchwarnmelders durch einen Si...

[Page 10] pyrexx RWM MC

18 19 Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder DE DE Rauchwarnmelder nicht verbunden bzw. defekt Wenn ein Rauchwarnmelder nicht mit dem RWM MC verbunden o...

[Page 11] pyrexx RWM MC

20 21 Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder Betriebsanleitung: RWM MC - Diagnosegerät für Rauchwarnmelder DE DE 7.3 Firmwareupdate und Funktionsprüfung Ein neu erworbenes Gerät wird immer mit der neuesten Firmw...

[Page 12] pyrexx RWM MC

EN 22 Operating Manual: RWM MC - Diagnostic device for smoke alarm devices Operating Manual: RWM MC - Diagnostic device for smoke alarm devices EN 23 1 Notes on the operating manual We are glad that you have chosen our product and we would ...

[Page 13] pyrexx RWM MC

EN 24 Operating Manual: RWM MC - Diagnostic device for smoke alarm devices Operating Manual: RWM MC - Diagnostic device for smoke alarm devices EN 25 also extend to any liability in relation to tradability and/or suitability for a particular ...

[Page 14] pyrexx RWM MC

EN 26 Operating Manual: RWM MC - Diagnostic device for smoke alarm devices Operating Manual: RWM MC - Diagnostic device for smoke alarm devices EN 27 Immersion in water Immersion in water can cause damage to the device. f Do not immerse the ...

[Page 15] pyrexx RWM MC

EN 28 Operating Manual: RWM MC - Diagnostic device for smoke alarm devices Operating Manual: RWM MC - Diagnostic device for smoke alarm devices EN 29 3 Overview 3.1 Function The RWM MC is used to read out smoke alarm devices and record the ...

[Page 16] pyrexx RWM MC

EN 30 Operating Manual: RWM MC - Diagnostic device for smoke alarm devices Operating Manual: RWM MC - Diagnostic device for smoke alarm devices EN 31 Energy-saving mode In energy-saving mode, the RWM MC is switched off when it is inactive for...

[Page 17] pyrexx RWM MC

EN 32 Operating Manual: RWM MC - Diagnostic device for smoke alarm devices Operating Manual: RWM MC - Diagnostic device for smoke alarm devices EN 33 Fig. 6 Connect the RWM MC to the smoke alarm device The long side of the triangular plug i...

[Page 18] pyrexx RWM MC

EN 34 Operating Manual: RWM MC - Diagnostic device for smoke alarm devices Operating Manual: RWM MC - Diagnostic device for smoke alarm devices EN 35 The message "Verschmutzt" (Contaminated) only appears on smoke alarm devices wher...

[Page 19] pyrexx RWM MC

EN 36 Operating Manual: RWM MC - Diagnostic device for smoke alarm devices Operating Manual: RWM MC - Diagnostic device for smoke alarm devices EN 37 Temperaturalarm (Temperature alarm) A temperature alarm is indicated by a sig- nal tone on t...

[Page 20] pyrexx RWM MC

EN 38 Operating Manual: RWM MC - Diagnostic device for smoke alarm devices Operating Manual: RWM MC - Diagnostic device for smoke alarm devices EN 39 6 Packaging, transport and storage 6.1 Packaging If you want to package the device for tr...

[Page 21] pyrexx RWM MC

40 41 Operating Manual: RWM MC - Diagnostic device for smoke alarm devices DE EN EN 8 Decommissioning 8.1 Final decommissioning Before disposing of the device, you must perform the  nal decommissioning: f Replace faulty device f Remove t...

[Page 22] pyrexx RWM MC

42 43 DE EN DE EN Optimale Lagerbedingungen / Optimal storage conditions 5 bis 35 °C, <70 % rel. Feuchte / 5 to 35° C, <70% rel. humidity Besonderheiten / Special features • Energiesparmodus / Energy-saving mode • Schnittstelle f�...

[Page 23] pyrexx RWM MC

© Pyrexx Technologies GmbH k_125093 Stand der Betriebsanleitung 2016-04 Revision of the brochure 2016-04 Impressum Pyrexx Technologies GmbH Spichernstraße 2 10777 Berlin Deutschland, Germany ...