[Page 1] Bosch SOLUTION 3000

Control Panel Solution 2000 / 3000 en Quick Reference Guide ...

[Page 2] Bosch SOLUTION 3000

...

[Page 3] Bosch SOLUTION 3000

Table of contents 1 Introduction 6 2 Programming 7 2.1 TEXT LCD Codepad Menu Programming 7 2.2 ICON LCD Codepad Programming 10 2.3 Programming Option Bits 11 2.4 Installer's programming commands 11 3 Operating Commands 12 3.1 Add/Delete RF Devic...

[Page 4] Bosch SOLUTION 3000

4.9.1 RF Supervision Time 31 4.9.2 RADION Anti-Jamming Sensitivity 32 4.9.3 RF Receiver 32 4.9.4 RF Options 32 4.10 Report Programming 32 4.10.1 Arm / Disarm Reporting Options 32 4.10.2 Codepad Reporting Options 32 4.11 System Status Programming 33 4...

[Page 5] Bosch SOLUTION 3000

4.19.2 Zone Names 46 4.19.3 User Names 47 5 Appendices 48 5.1 Connections for EOL Resistors 48 5.2 Wiring Diagram 49 5.3 Component Overlay 50 5.4 Codepad Address Setting 51 Control Panel Table of Contents | en 5 Bosch Security Systems, Inc. Quick Ref...

[Page 6] Bosch SOLUTION 3000

Introduction Thank you for choosing the Solution 2000 / 3000 Control Panel for your installation. You will find this system extremely flexible, reliable, and easy to use. This Quick Reference Guide is supplied with the system to provide users with en...

[Page 7] Bosch SOLUTION 3000

Programming The programming options of the system are stored in a non-volatile EPROM. This memory holds all information during a total power loss and can be changed as many times as required. The entire programming sequence consists of entering a loc...

[Page 8] Bosch SOLUTION 3000

. Command Installer Passcode Inquire System RF diagnose Test 1 2 3 4 5 Fault analysis1 Event recall 2 Day alarm2 Arm/disarm seq. 3 Report monitor 4 Modem call init. 5 Domestic phone 6 Version display 7 Factory default 8 RF zone1 RF Keyfob 2 RF Repeat...

[Page 9] Bosch SOLUTION 3000

Zone Zone config Installer Passcode Zone allocate Zone name Day alarm zone STAY2 zone EOL resistor Zone state report 4 1 2 3 4 5 6 7 Siren swing shutdown count1 Report swing shutdown count 2 Telco arming sequence 1 Telco disarming sequence 2 Delay al...

[Page 10] Bosch SOLUTION 3000

ICON LCD Codepad Programming The system must be disarmed (with no active alarm) to program the system. If there is an active alarm or the system is armed, enter the code for User 1 (Default = 2580) followed by the [#] key. (User Code 1 is factory def...

[Page 11] Bosch SOLUTION 3000

Programming Option Bits Use option bits to program any combination of the four different options in one location by adding the options together. Programming a zero disables all four options. Example If at Location 0178 you only want options 1, 2, a...

[Page 12] Bosch SOLUTION 3000

Operating Commands The system supports programmable 1- 4- digit Installer code or User Code to execute the following operating commands. No identical User Codes are allowed. User Codes are not permitted to be the same as Installer codes. For [Code] +...

[Page 13] Bosch SOLUTION 3000

Master/User Command Function Description Access Installer Command Function Description Access Code+[0][2] [#] AWAY Arm/Disarm Area 2 (U) Code+[-] Enter User Menu (text codepad only)) (U) Long Press Command Function Description Access [*]+...

[Page 14] Bosch SOLUTION 3000

Notice! Below commands examples are operated via IUI-SOL-ICON codepad. Add/Delete RF Device (Wireless Zones) Notice! The Solution 2000 control panel does not support wireless devices. Add RF Device Set RF receiver as RADION Receiver. 1. Enter the Ins...

[Page 15] Bosch SOLUTION 3000

3. Press the [*] key to delete the RF Repeater. Example: To delete existing RF Repeater 8: Enter your installer code and press [0] [#] [8] [2] [9] [#] [*]. Add/Delete RF Keyfob Add WE800EV2 Keyfob Notice! Learn all WE800EV2 keyfobs via WE800EV2 recei...

[Page 16] Bosch SOLUTION 3000

Notice! The Solution 2000 control panel does not support RADION keyfobs. Set the Number of Days until the First Test Report 1. Enter the Installer Code, followed by [1] and the [#] key. 2. Enter the Number of Days (0 to 15) until the first Test Repor...

[Page 17] Bosch SOLUTION 3000

Zone LED for Receiver 1 Zone LED for Receiver 2 Report Event 3 11 Handshake Received 4 12 Data Being Sent 5 13 Kiss-Off Received None None Released Telephone Line / Idle Table 3.2: Report Monitor Mode Indications Notice! You must exit from Report Mon...

[Page 18] Bosch SOLUTION 3000

Fault Indicators Zone Indicator Fault Description Press Button Zone Indicator Fault Condition 1 System Fault 1 1 2 3 4 5 7 8 9 to 16 Battery Fail Date and Time RF Receiver Fail Output 1 to 3 Fail Telephone Line Fail Power Supply Fail Onboard Tamper R...

[Page 19] Bosch SOLUTION 3000

Telephone Line Fail – A telephone line fault registers when the system detects that the telephone line is disconnected from the control panel. Your installer must program the system for this feature to operate. Power Supply Fail – This fault occu...

[Page 20] Bosch SOLUTION 3000

Programming Parameters Notice! Column New is for installer to record new programming parameters. Communication Programming Receiver 1 Item Location Option Default New Phone Number 1 0000 - 0015 15 = Telephone termination 15 Phone Number 2 0016 - ...

[Page 21] Bosch SOLUTION 3000

Item Location Option Default New Transmission Format 0073 0 = Not used 1 = Contact ID 4 = Domestic 5 = Conettix IP 6 = SIA Fast 7 = SIA Slow 8 = CSVIP 9 = Email 1 Subscriber ID Number 0074 - 0079 0 IP + Port / Email 1200 - 1299 CSVIP User...

[Page 22] Bosch SOLUTION 3000

Codepad Key Characters / Function Codepad key Characters / Function ▲ Step back former character 6 [ m ], [ n ], [ o ], [ 6 ] _ Exit item setting 7 [ p ], [ q ], [ r ], [ s ], [ 7 ] ▼ Move to next character 8 [ t ], [ u ], [ v ], [ 8 ] 1 [ . ], [...

[Page 23] Bosch SOLUTION 3000

Password for A-Link Plus/RSC Connection Item Location Option Default New Password for A-Link Plus/RSC Connection 0083 - 0092 0 DTMF Timing Compensation Item Location Option Default New DTMF Timing Compensation 0111 0 = Disable 1 – 9 = Timing co...

[Page 24] Bosch SOLUTION 3000

Telephone Line Fail Options Item Location Option Default New Telephone Line Fail Options 0176 1 = Display FAULT Indicator when telephone line fails 2 = Sound alarm when system is armed 4 = Sound alarm when system is disarmed 8 = Reserved 0 Notice! ...

[Page 25] Bosch SOLUTION 3000

A-Link Plus Options Item Location Option Default New A-Link Plus Options 0180 1 = Upload/download allowed 2 = Call back phone number required for upload/download 4 = Exit from upload/download connection on alarm 8 = Reserved 3 Installer Code Item L...

[Page 26] Bosch SOLUTION 3000

Item Location Default New Authority Level Location Default New User #17 0566 - 0569 15 0570 2 User #18 0571 - 0574 15 0575 2 User #19 0576 - 0579 15 0580 2 User #20 0581 - 0584 15 0585 2 User #21 0586 - 0589 15 0590 2 User #22 059...

[Page 27] Bosch SOLUTION 3000

Day Alarm Zones Item Location Option Default New Day Alarm Zones 0265 1 = Zone 1 2 = Zone 2 4 = Zone 3 8 = Zone 4 0 EOL Resistor Value Item Location Option Default New EOL Resistor Value 0266 0 = No EOL 1 = 1k 2 = 1k5 3 = 2k2 4 = 3k3 5 = 3k9 6 = 4k...

[Page 28] Bosch SOLUTION 3000

Item Location Default New Item Location Default New Zone Type 0295 0 Zone Type 0302 0 Zone Pulse Count 0296 0 Zone Pulse Count 0303 0 Zone Pulse Count Time 0297 0 Zone Pulse Count Time 0304 0 Zone Options 1 0298 1 Zone Options 1 0305 1 ...

[Page 29] Bosch SOLUTION 3000

Item Location Default New Item Location Default New Zone Pulse Count 0352 0 Zone Pulse Count 0359 0 Zone Pulse Count Time 0353 0 Zone Pulse Count Time 0360 0 Zone Options 1 0354 1 Zone Options 1 0361 1 Zone Options 2 0355 14 Zone Option...

[Page 30] Bosch SOLUTION 3000

Item Option Zone Options 1 1 = Lockout siren/report 2 = Delay alarm report 4 = Silent alarm 8 = Sensor watch Zone Options 2 1 = Isolated in STAY Mode 1 2 = Zone isolation allowed 4 = Forced arming allowed 8 = Zone Restore Report allowed Zone Report O...

[Page 31] Bosch SOLUTION 3000

Swinger Shutdown Count For Report Item Location Option Default New Swinger Shutdown Count For Report 0380 1 – 15 = Number of times report operates until lockout 6 Zone Status Programming STAY Mode 2 Automatically Bypass Zones Item Location Option...

[Page 32] Bosch SOLUTION 3000

RADION Anti-Jamming Sensitivity Item Location Option Default New RADION Anti-Jamming Sensitivity (Only for Solution 3000 ) 0394 0 = Most Sensitive 15 = Least Sensitive 12 RF Receiver Item Location Option Default New RF Receiver 0395 0 = Not used ...

[Page 33] Bosch SOLUTION 3000

System Status Programming Access Denied(Code Retry) Item Location Option Default New Code retry limit 0424 0 = Unlimited 1 – 15 = Error code attempts 6 System Status Reporting Options Item Location Option Default New System Status Reporting Optio...

[Page 34] Bosch SOLUTION 3000

Output Programming Item Location Default New Item Location Default New Output 1 (Default = Horn Speaker) Output 2 (Default = Fire Alarm With Verification) Event Code 0436 1 Event Code 0442 2 Event Code 0437 14 Event Code 0443 7 Polarity 0438 ...

[Page 35] Bosch SOLUTION 3000

Item Location Default New Item Location Default New B308 Output 1 B308 Output 2 Event Code 0646 0 Event Code 0652 0 Event Code 0647 0 Event Code 0653 0 Polarity 0648 0 Polarity 0654 0 Time Base 0649 0 Time Base 0655 0 Time Base Multip...

[Page 36] Bosch SOLUTION 3000

Item Location Default New Item Location Default New B308 Output 9 B308 Output 10 Event Code 0694 0 Event Code 0700 0 Event Code 0695 0 Event Code 0701 0 Polarity 0696 0 Polarity 0702 0 Time Base 0697 0 Time Base 0703 0 Time Base Multi...

[Page 37] Bosch SOLUTION 3000

Item Option Event Code 0 0 = Reserved 0 1 = System armed 0 2 = System disarmed 0 3 = Armed in STAY mode 0 4 = Armed in AWAY mode 0 5 = Pre-arming alert 0 6 = Exit Warning (all zones sealed) and entry warning 0 7 = Exit Warning 0 8 = Exit Warning fini...

[Page 38] Bosch SOLUTION 3000

Item Option Event Code 4 0 = Reserved 4 1 = Reserved 4 2 = Reserved 4 3 = Reserved 4 4 = Reserved 4 5 = Chime 4 6 = Zone not sealed 4 7 = Zone not sealed after Exit Time 4 8 = Reserved 4 9 = AC MAINS cycle (60 Hz or 50 Hz) 4 10 = Area 1 – zone unse...

[Page 39] Bosch SOLUTION 3000

*Pulsing Mode When you program the output polarity as pulsing, the time base becomes the ON time and the multiplier becomes the OFF time. The OFF time is the time base x the multiplier. (For example, if you want the output to pulse 1 sec. ON and 5 se...

[Page 40] Bosch SOLUTION 3000

Sensor Watch Time Item Location Option Default New Increments of days (tens digit) 0476 0 Increments of days (units digit) 0477 0 Codepad Lockout Time Item Location Option Default New Codepad Lockout Time 0478 0 = No lockout 1 – 15 = Lockou...

[Page 41] Bosch SOLUTION 3000

Auto Disarming Time Item Location Option Default New Hour of the day (tens digit) 0486 0 Hour of the day (units digit) 0487 0 Minute of the day (tens digit) 0488 0 Minute of the day (units digit) 0489 0 Kiss-Off Wait Time Item Locatio...

[Page 42] Bosch SOLUTION 3000

System Options 3 Item Location Option Default New System Options 3 0494 1 = AC fail after 1 hr. (Disabled = after 2 min.) 2 = Ignore AC fail 4 = Pulse count handover allowed 8 = Handover delay to be sequential 8 System Options 4 Item Location Optio...

[Page 43] Bosch SOLUTION 3000

Partitioning Options 1 Item Location Option Default New Partitioning Options 1 0500 1 = First to Disarm/Last to Arm reporting 2 = Reserved 4 = Reset sirens from any area allowed 8 = Reserved 0 Partitioning Options 2 Item Location Option Default New...

[Page 44] Bosch SOLUTION 3000

Codepad Assignment Item Location Default New Item Location Default New Codepad 1 Area 0518 1 Codepad 2 Area 0519 0 Codepad 3 Area 0520 0 Codepad 4 Area 0521 0 Option 0 = Codepad area not assigned 1 = Codepad assigned to Area 1 2 = Codepad ass...

[Page 45] Bosch SOLUTION 3000

RFID Programming Keyfob RFID Item Location Default New Item Location Default New Keyfob #01 1500 - 1507 0 Keyfob #02 1510 - 1517 0 Keyfob #03 1520 - 1527 0 Keyfob #04 1530 - 1537 0 Keyfob #05 1540 - 1547 0 Keyfob #06 1550 - 1557 0 Keyfob ...

[Page 46] Bosch SOLUTION 3000

Item Location Default New RF Zone Option Location Default New RF Zone #12 1930 - 1937 0 1938 0 RF Zone #13 1940 - 1947 0 1948 0 RF Zone #14 1950 - 1957 0 1958 0 RF Zone #15 1960 - 1967 0 1968 0 RF Zone #16 1970 - 1977 0 1978 0 Ite...

[Page 47] Bosch SOLUTION 3000

Item Location New Item Location New Zone 4 Name 2608 - 2631 Zone 12 Name 2800 - 2823 Zone 5 Name 2632 - 2655 Zone 13 Name 2824 - 2847 Zone 6 Name 2656 - 2679 Zone 14 Name 2848 - 2871 Zone 7 Name 2680 - 2703 Zone 15 Name 2872 - 2895 Zo...

[Page 48] Bosch SOLUTION 3000

Appendices Connections for EOL Resistors Zone without resistor (Location 266 = 0 (No EOL)) ZONE 1 N/C Table 5.1: Connection 1 Single Zone input (Location 266 = 1k, 1k5, 2k2, 3k3, 3k9, 4k7, 5k6, 6k8, 10k, 12k, 22k) ZONE 1 N/C Table 5.2: Connection...

[Page 49] Bosch SOLUTION 3000

Wiring Diagram GND c +12V Slow flash: Normal state On: Trouble state Off: Trouble state TF008-B [email protected] Battery 12V 7Ah R B B G Y R B G Y R B G Y R B G Y 3K3 PIR Siren Smoke detector 6K8 3K3 6K8 3K3 6K8 3K3 6K8 R Y G B _ Bosch SDI2 Bus 1,2,3 &...

[Page 50] Bosch SOLUTION 3000

Component Overlay 1 2 3 5 5 9 10 11 12 13 14 4 6 7 8 GND c +12V Figure 5.2: Component Overlay 5.3 50 en | Appendices Control Panel 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc. ...

[Page 51] Bosch SOLUTION 3000

Callout --Description Callout --Description 1 – Socket for telecom lead connect 8 – Bosch SDI2 Bus 2 – Receiver interface connection 9 – Battery input 3 – Tamper switch 10 – Plug pack input (Bosch TF008) 4 – Zone 5-8 termination strip (...

[Page 52] Bosch SOLUTION 3000

...

[Page 53] Bosch SOLUTION 3000

...

[Page 54] Bosch SOLUTION 3000

Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450 USA www.boschsecurity.com © Bosch Security Systems, Inc., 2015 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany ...