[Page 1] HP ProLiant DL60 Gen9

HPE ProLiant DL60 Gen9 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified in the servicing of computer...

[Page 2] HP ProLiant DL60 Gen9

© Copyright 2014, 2016 Hewlett Packard Enterprise Development LP The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty...

[Page 3] HP ProLiant DL60 Gen9

Contents 3 Contents Component identification ............................................................................................................................ 6 Front panel components.....................................................

[Page 4] HP ProLiant DL60 Gen9

Contents 4 Installing a storage controller and FBWC module ........................................................................................ 40 Installing a Smart Storage Battery ..............................................................

[Page 5] HP ProLiant DL60 Gen9

Contents 5 Flexible boot control ...................................................................................................................................... 95 Restoring and customizing configuration settings ............................

[Page 6] HP ProLiant DL60 Gen9

Component identification 6 Component identification Front panel components Item Description 1 Optical drive (optional) 2 Serial label pull tab The serial number/iLO information pull tab is double-sided. The top side shows the ser...

[Page 7] HP ProLiant DL60 Gen9

Component identification 7 Front panel LEDs and buttons Item Description Status 1 UID button/LED Solid blue = Activated Flashing blue: • 1 flash per second = Remote management or firmware upgrade in progress • 4 flashes ...

[Page 8] HP ProLiant DL60 Gen9

Component identification 8 When all four LEDs described in this table flash simultaneously, a power fault has occurred. For more information, see "Power fault LEDs ("Front panel LED power fault codes" on page 8)." Front pa...

[Page 9] HP ProLiant DL60 Gen9

Component identification 9 Rear panel LEDs Item Description Status 1 UID LED Solid blue = Activated Flashing blue: • 1 flash per second = Remote management or firmware upgrade in progress • 4 flashes per second = iLO ma...

[Page 10] HP ProLiant DL60 Gen9

Component identification 10 System board components Item Description 1 Primary PCIe riser board connector* 2 TPM connector 3 System battery 4 SATA connector 5 Storage backup power connector for PCIe slots 1-2 6 Reserv...

[Page 11] HP ProLiant DL60 Gen9

Component identification 11 DIMM slot locations DIMM slots are numbered sequentially (1 through 4) for each processor. The supported AMP modes use the letter assignments for population guidelines. The arrow points to the front of the server....

[Page 12] HP ProLiant DL60 Gen9

Component identification 12 CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to properly configure the server or data loss could occur. Before using the S7 switch to change the boot mode to Legacy BIOS Mode, ...

[Page 13] HP ProLiant DL60 Gen9

Component identification 13 Hot-plug drive LED definitions Item LED Status Definition 1 Locate Solid blue The drive is being identified by a host application. Flashing blue The drive carrier firmware is being updated or r...

[Page 14] HP ProLiant DL60 Gen9

Component identification 14 Fan locations ...

[Page 15] HP ProLiant DL60 Gen9

Operations 15 Operations Power up the server 1. Connect each power cord to the server. 2. Connect each power cord to the power source. 3. Press the Power On/Standby button. The server exits standby mode and applies full power to the syste...

[Page 16] HP ProLiant DL60 Gen9

Operations 16 1. If the rear panel cables are not secured by a cable management arm, do the following: a. Power down the server (on page 15). b. Disconnect all peripheral cables from the server. c. Disconnect each power cord from the serve...

[Page 17] HP ProLiant DL60 Gen9

Operations 17 o In a server that uses quick-release latch rack ears, if necessary, tighten the shipping screws. 5. If the rear panel cables were disconnected because a cable management arm is not in use, do the following: a. Connect each po...

[Page 18] HP ProLiant DL60 Gen9

Operations 18 Remove the server from the rack WARNING: This server is very heavy. To reduce the risk of personal injury or damage to the equipment: • Observe local occupational health and safety requirements and guidelines for manua...

[Page 19] HP ProLiant DL60 Gen9

Operations 19 CAUTION: To prevent damage to electrical components, take the appropriate anti-static precautions before beginning any installation, removal, or replacement procedure. Improper grounding can cause electrostatic discharge. ...

[Page 20] HP ProLiant DL60 Gen9

Operations 20 To remove the component: 1. Power down the server (on page 15). 2. If you are performing a non-hot-plug procedure, remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the...

[Page 21] HP ProLiant DL60 Gen9

Operations 21 To install the component: 1. Install the air baffle. 2. Install the access panel (on page 19). 3. Do one of the following: o Slide the server into the rack. o Install the server into the rack. 4. Power up the server (o...

[Page 22] HP ProLiant DL60 Gen9

Operations 22 o Secondary PCI riser cage o PCI blank ...

[Page 23] HP ProLiant DL60 Gen9

Operations 23 7. Remove any expansion boards installed in the primary riser cage. 8. Remove the primary PCI riser cage. Install the PCI riser cage CAUTION: To prevent damage to the server or expansion boards, power down the serve...

[Page 24] HP ProLiant DL60 Gen9

Operations 24 1. Align the PCI riser board with the corresponding connectors on the system board, and then press down the PCI riser cage. 2. If installing the secondary PCI riser cage, remove the PCI blank. Retain the blank and screws fo...

[Page 25] HP ProLiant DL60 Gen9

Operations 25 4. Tighten the two screws to secure the cage. 5. Install the access panel (on page 19). 6. Do one of the following: o Slide the server into the rack. o Install the server into the rack. 7. Power up the server (on page 1...

[Page 26] HP ProLiant DL60 Gen9

Setup 26 Setup Optional services Delivered by experienced, certified engineers, HPE support services help you keep your servers up and running with support packages tailored specifically for HPE ProLiant systems. HPE support services let you ...

[Page 27] HP ProLiant DL60 Gen9

Setup 27 CAUTION: To prevent improper cooling and damage to the equipment, do not block the ventilation openings. When vertical space in the rack is not filled by a server or rack component, the gaps between the components might cause ch...

[Page 28] HP ProLiant DL60 Gen9

Setup 28 When installing more than one server, you might need to use additional power distribution devices to safely provide power to all devices. Observe the following guidelines: • Balance the server power load between available AC supply ...

[Page 29] HP ProLiant DL60 Gen9

Setup 29 CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the server in this manner results in improper airflow and improper cooling that can lead to thermal damage. Rack warnings ...

[Page 30] HP ProLiant DL60 Gen9

Setup 30 Installing hardware options Install any hardware options before initializing the server. For options installation information, see the option documentation. For server-specific information, see "Hardware options installation (on p...

[Page 31] HP ProLiant DL60 Gen9

Setup 31 a. If the clip is positioned too near the power cord that it blocks the power cord plug connection, slide the clip backward. b. Connect the power cord to the server. c. Press the top part of the clip, and then pull the clip open....

[Page 32] HP ProLiant DL60 Gen9

Setup 32 e. Slide the clip forward until it is flush against the edge of the power cord plug. For a server using a hot-plug power supply: 4. To prevent accidental power cord disconnection when sliding the server in and out of the rack, sec...

[Page 33] HP ProLiant DL60 Gen9

Setup 33 c. Secure the power cord with the strain relief strap. 5. Employ best practices to route and manage the power cords and other cables in the server rear panel. IMPORTANT: When using cable management arm components, be sure to...

[Page 34] HP ProLiant DL60 Gen9

Setup 34 b. Loop the end of the hook-and-loop strap through the buckle. When multiple hook-and-loop straps are used in the same rack, stagger the strap location, so that the straps are adjacent to each other when viewed from top to bottom. T...

[Page 35] HP ProLiant DL60 Gen9

Setup 35 For additional system software and firmware updates, download the Service Pack for ProLiant from the Hewlett Packard Enterprise website (http://www.hpe.com/servers/spp/download). Software and firmware must be updated before using the s...

[Page 36] HP ProLiant DL60 Gen9

Hardware options installation 36 Hardware options installation Introduction If more than one option is being installed, read the installation instructions for all the hardware options and identify similar steps to streamline the installation p...

[Page 37] HP ProLiant DL60 Gen9

Hardware options installation 37 Drive installation guidelines When adding drives to the server, observe the following general guidelines: • The system automatically sets all device numbers. • Populate drive bays, based on the drive numb...

[Page 38] HP ProLiant DL60 Gen9

Hardware options installation 38 6. Install the drive in the carrier. 7. Install the drive. CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or...

[Page 39] HP ProLiant DL60 Gen9

Hardware options installation 39 2. Remove the drive blank. 3. Prepare the drive. 4. Install the drive. 5. Determine the status of the drive from the drive LED definitions ("Hot-plug drive LED definitions" on page 13). 6....

[Page 40] HP ProLiant DL60 Gen9

Hardware options installation 40 To configure arrays, see the HPE Smart Storage Administrator User Guide on the Hewlett Packard Enterprise website (http://www.hpe.com/info/smartstorage/docs). The server supports FBWC. FBWC consists of a cache m...

[Page 41] HP ProLiant DL60 Gen9

Hardware options installation 41 6. Remove the secondary PCI riser cage ("Remove the PCI riser cage" on page 21). CAUTION: When connecting or disconnecting the cache module cable, the connectors on the cache module and cable ...

[Page 42] HP ProLiant DL60 Gen9

Hardware options installation 42 13. Install the access panel (on page 19). 14. Do one of the following: o Slide the server into the rack. o Install the server into the rack. 15. Power up the server (on page 15). 16. If you are plannin...

[Page 43] HP ProLiant DL60 Gen9

Hardware options installation 43 6. Install the access panel (on page 19). 7. Do one of the following: o Slide the server into the rack. o Install the server into the rack. 8. Power up the server (on page 15). Drive cable options Use...

[Page 44] HP ProLiant DL60 Gen9

Hardware options installation 44 13. Route the Mini-SAS cables through the clip and connect the connectors to the drive backplane. o H240 Host Bus Adapter to the 4 LFF drive backplane o P440 Smart Array Controller to the 4 LFF drive backpl...

[Page 45] HP ProLiant DL60 Gen9

Hardware options installation 45 Optical drive option For more information about product features, specifications, options, configurations, and compatibility, see the product QuickSpecs on the Hewlett Packard Enterprise website (http://www.hpe....

[Page 46] HP ProLiant DL60 Gen9

Hardware options installation 46 6. Install the optical drive into the bay. 7. Connect the optical drive cable to the optical drive. 8. Route the optical drive cable through the cable clip, connect the cable to the system board SATA conne...

[Page 47] HP ProLiant DL60 Gen9

Hardware options installation 47 Fan population guidelines Configuration Fan bay 1 Fan bay 2 Fan bay 3 Fan bay 4 Fan bay 5 Fan bay 6 One processor, non-redundant Fan Fan Blank Fan Blank Blank One processor, redun...

[Page 48] HP ProLiant DL60 Gen9

Hardware options installation 48 6. To determine which fan blanks need to be removed to install the additional fans, see "Fan population guidelines." 7. Remove the fan blank. 8. Install the fan. CAUTION: The fan does not ...

[Page 49] HP ProLiant DL60 Gen9

Hardware options installation 49 o Install the server into the rack. 13. Power up the server (on page 15). Memory options IMPORTANT: This server does not support mixing LRDIMMs and RDIMMs. Attempting to mix any combination of these ...

[Page 50] HP ProLiant DL60 Gen9

Hardware options installation 50 Populated DIMM speed (MT/s) Operating memory speed is a function of rated DIMM speed, the number of DIMMs installed per channel, processor model, and the speed selected in the BIOS/Platform Configuration (RBSU) ...

[Page 51] HP ProLiant DL60 Gen9

Hardware options installation 51 Qualified memory is performance-tuned for ProLiant and BladeSystem servers and provides future enhanced support through Active Health and manageability software. Memory subsystem architecture The memory subsy...

[Page 52] HP ProLiant DL60 Gen9

Hardware options installation 52 DIMM identification To determine DIMM characteristics, see the label attached to the DIMM and refer to the following illustration and table. Item Description Definition 1 Capacity 8 GB 16 GB 32...

[Page 53] HP ProLiant DL60 Gen9

Hardware options installation 53 ECC mode. For more information, see the HPE UEFI System Utilities User Guide for HPE ProLiant Gen9 Servers on the Hewlett Packard Enterprise website (http://www.hpe.com/info/ProLiantUEFI/docs). Advanced ECC me...

[Page 54] HP ProLiant DL60 Gen9

Hardware options installation 54 • When single-rank, dual-rank, and quad-rank DIMMs are populated for two DIMMs per channel, always populate the higher number rank DIMM first (starting from the farthest slot). For example, first quad-rank DI...

[Page 55] HP ProLiant DL60 Gen9

Hardware options installation 55 2. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Do one of the following: o Extend the server from the rack (on page 15). o Rem...

[Page 56] HP ProLiant DL60 Gen9

Hardware options installation 56 Processor installation cautions The server supports single-processor and dual-processor operations. CAUTION: To avoid damage to the processor and system board, only authorized personnel should attempt t...

[Page 57] HP ProLiant DL60 Gen9

Hardware options installation 57 Retain the blank for future use. CAUTION: The pins on the processor socket are very fragile. Any damage to them may require replacing the system board. 6. Open each of the processor locking levers i...

[Page 58] HP ProLiant DL60 Gen9

Hardware options installation 58 7. Remove the clear processor socket cover. Retain the processor socket cover for future use. CAUTION: THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. To avoid damage to the system boa...

[Page 59] HP ProLiant DL60 Gen9

Hardware options installation 59 10. Press and hold the processor retaining bracket in place, and then close each processor locking lever. Press only in the area indicated on the processor retaining bracket. 11. Remove the thermal interface...

[Page 60] HP ProLiant DL60 Gen9

Hardware options installation 60 b. Finish the installation by completely tightening the screws in the same sequence. To determine which fan blanks need to be removed to install the additional fans, see "Fan population guidelines."...

[Page 61] HP ProLiant DL60 Gen9

Hardware options installation 61 4. Connect the fan cable to the system board. 5. Install the air baffle ("Remove the air baffle" on page 19, on page 20). 6. Install the access panel (on page 19). 7. Do one of the following: o...

[Page 62] HP ProLiant DL60 Gen9

Hardware options installation 62 6. Remove the PCI riser cage. Retain the cage and screws for future use. 7. Remove the blank from the FLexibleLOM slot of the riser cage. 8. Install the component: a. Firmly seat the FlexibleLOM into t...

[Page 63] HP ProLiant DL60 Gen9

Hardware options installation 63 b. Tighten the T-15 screw to secure the component. 9. Align the PCI riser board with the corresponding connector on the system board, and then press down the riser cage. 10. Tighten the two screws to secur...

[Page 64] HP ProLiant DL60 Gen9

Hardware options installation 64 CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all PCI slots have either an expansion slot cover or an expansion board installed. For more information about produ...

[Page 65] HP ProLiant DL60 Gen9

Hardware options installation 65 7. Install the expansion board. 8. Align the PCI riser board with the corresponding connector on the system board, and then press down the riser cage. 9. Tighten the two screws to secure the cage. 10. ...

[Page 66] HP ProLiant DL60 Gen9

Hardware options installation 66 CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all expansion slots have either an expansion slot cover or an expansion board installed. To install the compone...

[Page 67] HP ProLiant DL60 Gen9

Hardware options installation 67 o Slot 3 7. Install the expansion board. o Slot 1 (If a secondary PCI riser cage is installed, remove the secondary cage before installing the expansion board into slot 1.) o Slot 2 ...

[Page 68] HP ProLiant DL60 Gen9

Hardware options installation 68 o Slot 3 8. Align the PCI riser board with the corresponding connector on the system board, and then press down the riser cage. 9. Tighten the two screws to secure the cage. IMPORTANT: The server ...

[Page 69] HP ProLiant DL60 Gen9

Hardware options installation 69 2. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Do one of the following: o Extend the server from the rack (on page 15). o Rem...

[Page 70] HP ProLiant DL60 Gen9

Hardware options installation 70 o Slot 2 o Slot 3 8. Install the PCI riser cage (on page 23). 9. Connect the SATA cables to the SATA connectors on the system board. For slot 2 and 3 cable routing, see "M.2 SSD cabling (on page 8...

[Page 71] HP ProLiant DL60 Gen9

Hardware options installation 71 This USB storage device contains a dual-SD card module that supports up to two SD, SDHC, or SDXC storage cards providing data redundancy through a mirrored RAID-1 configuration. This USB storage device connects ...

[Page 72] HP ProLiant DL60 Gen9

Hardware options installation 72 3. Release the power cord from the strain relief clip. 4. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 5. Remove the server from ...

[Page 73] HP ProLiant DL60 Gen9

Hardware options installation 73 10. Remove the non-hot-plug power supply. 11. Install the RPS backplane assembly in the server. ...

[Page 74] HP ProLiant DL60 Gen9

Hardware options installation 74 12. Connect the RPS backplane cables to the system board. 13. Install a hot-plug power input module in power supply bay 1. For the power supply bay locations, see "Rear panel components." 14. I...

[Page 75] HP ProLiant DL60 Gen9

Hardware options installation 75 b. Install a hot-plug power input module in power supply bay 2. 15. If removed, install the secondary PCI riser cage. 16. Install the access panel (on page 19). 17. Install the server into the rack. 18. C...

[Page 76] HP ProLiant DL60 Gen9

Hardware options installation 76 21. Employ best practices to route and manage the power cords and other cables in the server rear panel. 22. Power up the server (on page 15). HP Trusted Platform Module option This server supports both TP...

[Page 77] HP ProLiant DL60 Gen9

Hardware options installation 77 WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. To install the component: 1. Power down the server (o...

[Page 78] HP ProLiant DL60 Gen9

Hardware options installation 78 8. Install the TPM security rivet by pressing the rivet firmly into the system board. 9. Install the PCI riser cage (on page 23). 10. Install the access panel (on page 19). 11. Install the server into the...

[Page 79] HP ProLiant DL60 Gen9

Hardware options installation 79 You can now enable TPM functionality in the OS, such as Microsoft Windows BitLocker or measured boot. CAUTION: When a TPM is installed and enabled on the server, data access is locked if you fail to fo...

[Page 80] HP ProLiant DL60 Gen9

Cabling 80 Cabling Cabling overview This section provides guidelines that help you make informed decisions about cabling the server and hardware options to optimize performance. For information on cabling peripheral components, refer to the w...

[Page 81] HP ProLiant DL60 Gen9

Cabling 81 • Four-bay LFF non-hot-plug drive backplane connected to the H240 Host Bus Adapter Item Description 1 Drive power cable 2 Mini-SAS cable Four-bay LFF hot-plug drive cabling • Four-bay LFF drive backplane conne...

[Page 82] HP ProLiant DL60 Gen9

Cabling 82 • Four-bay LFF drive backplane connected to a P440 controller in the low-profile expansion slot 1 Item Description 1 Drive power cable 2 Mini-SAS cable • Four-bay LFF drive backplane connected to a H240 adapter i...

[Page 83] HP ProLiant DL60 Gen9

Cabling 83 M.2 SSD cabling • Slot 2 cable routing (2 ports supported when slot 1 is unoccupied) • Slot 2 cable routing (1 port supported when slot 1 is occupied) ...

[Page 84] HP ProLiant DL60 Gen9

Cabling 84 • Slot 3 cable routing (2 ports supported when slot 1 is unoccupied) • Slot 3 cable routing (1 port supported when slot 1 is occupied) ...

[Page 85] HP ProLiant DL60 Gen9

Cabling 85 • Slot 2 cable routing with FlexibleLOM riser (2 ports supported when slot 1 is unoccupied) • Slot 2 cable routing with FlexibleLOM riser (1 port supported when slot 1 is occupied) FBWC cabling The FBWC solution is a sep...

[Page 86] HP ProLiant DL60 Gen9

Cabling 86 • FBWC module slot 1 cabling • FBWC module slot 2 cabling ...

[Page 87] HP ProLiant DL60 Gen9

Cabling 87 • FBWC module slot 3 cabling Smart Storage battery cabling ...

[Page 88] HP ProLiant DL60 Gen9

Cabling 88 Power supply cabling • HPE 550 W non-hot-plug power supply cabling Item Description 1 16-pin power supply sideband signal cable 2 24-pin power supply cable • HPE Redundant Power Supply cabling Item Descr...

[Page 89] HP ProLiant DL60 Gen9

Cabling 89 Optical drive cabling Item Description 1 Optical drive cable 2 Drive power cable Front I/O cabling Item Description 1 Front I/O cable 2 USB 2.0 connector cable 3 Ambient temperature sensor cable ...

[Page 90] HP ProLiant DL60 Gen9

Software and configuration utilities 90 Software and configuration utilities Server mode The software and configuration utilities presented in this section operate in online mode, offline mode, or in both modes. Software or configuration...

[Page 91] HP ProLiant DL60 Gen9

Software and configuration utilities 91 • Implement true Agentless Management with SNMP alerts from iLO, regardless of the state of the host server. • Download the Active Health System log. • Register for HPE remote support. • Use...

[Page 92] HP ProLiant DL60 Gen9

Software and configuration utilities 92 log can be downloaded manually from iLO 4 or HPE Intelligent Provisioning and sent to Hewlett Packard Enterprise. For more information, see the following documents: • iLO User Guide on the Hewlett Pac...

[Page 93] HP ProLiant DL60 Gen9

Software and configuration utilities 93 For more information about Intelligent Provisioning software, see the Hewlett Packard Enterprise website (http://www.hpe.com/servers/intelligentprovisioning). For Intelligent Provisioning recovery media d...

[Page 94] HP ProLiant DL60 Gen9

Software and configuration utilities 94 Scripting Toolkit for Windows and Linux The STK for Windows and Linux is a server deployment product that delivers an unattended automated installation for high-volume server deployments. The STK is desig...

[Page 95] HP ProLiant DL60 Gen9

Software and configuration utilities 95 • Configuring memory options • Selecting a language • Launching other pre-boot environments such as the Embedded UEFI Shell and Intelligent Provisioning For more information on the UEFI System ...

[Page 96] HP ProLiant DL60 Gen9

Software and configuration utilities 96 For more information, see the HPE UEFI System Utilities User Guide for HPE ProLiant Gen9 Servers on the Hewlett Packard Enterprise website (http://www.hpe.com/info/uefi/docs). Restoring and customizing ...

[Page 97] HP ProLiant DL60 Gen9

Software and configuration utilities 97 Embedded Diagnostics option The system BIOS in all ProLiant Gen9 servers includes an Embedded Diagnostics option in the ROM. The Embedded Diagnostics option can run comprehensive diagnostics of the server...

[Page 98] HP ProLiant DL60 Gen9

Software and configuration utilities 98 • Supports online array capacity expansion, logical drive extension, assignment of online spares, and RAID or stripe size migration • Provides diagnostic and SmartSSD Wear Gauge functionality on the...

[Page 99] HP ProLiant DL60 Gen9

Software and configuration utilities 99 Safety and security benefits When you flash the system ROM, the flashing mechanism writes over the backup ROM and saves the current ROM as a backup, enabling you to switch easily to the alternate ROM vers...

[Page 100] HP ProLiant DL60 Gen9

Software and configuration utilities 100 For more information about the One-Time Boot Menu, see the HPE UEFI System Utilities User Guide for HPE ProLiant Gen9 Servers on the Hewlett Packard Enterprise website (http://www.hpe.com/info/uefi/docs)...