Mobeye CM2410 User Manual

Download or browse on-line these Operation & User’s Manual for Mobeye CM2410 Cell Phone, Smoke Alarm.

Mobeye CM2410 Manual Information:

This manual for Mobeye CM2410, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 24 pages, and the size of the file at download is . The document type is Operation & User’s Manual.

Download Manual

More Manuals:

In case you failed to obtain relevant information in this document, please, look through related operating manuals and user instructions for Mobeye CM2410. Just click one of the links below to go to the selected manual:

Summary of Contents:

[Page 1] Mobeye CM2410

USER MANUAL Mobeye ® CM2410 GSM fire alarm communicator Accessory for Ei Electronics fire detector SW version 4.n Incl. CM2400 ...

[Page 2] Mobeye CM2410

Attention! Very important This user manual contains important guidelines for the installation and usage of the Mobeye ® device in combination with an Ei Electronics fire detector. Please read the manual thoroughly before you start using the de...

[Page 3] Mobeye CM2410

CONTENT 1. General description 2 2. Getting started 3 2.1 Insert a SIM card 3 2.2 Insert the batteries 3 2.3 Enter the program mode 4 2.4 Program at least one telephone number 4 2.5 Mount the GSM module housing to the ceiling 5 ...

[Page 4] Mobeye CM2410

1 ...

[Page 5] Mobeye CM2410

2 1. GENERAL DESCRIPTION The Mobeye GSM fire alarm communicator CM2410 is a battery operated GSM module used to send out an alarm after the input is triggered by a Ei Electronics smoke or heat detector. The Mobeye Smoke Detector CM2400 is a com...

[Page 6] Mobeye CM2410

3 2. GETTING STARTED To get started with the Mobeye CM2410 at least the following steps need to be taken in following order: 1. Place a SIM card (with PIN code 0000 or without PIN code) 2. Place the batteries 3. Enter the program mode 4...

[Page 7] Mobeye CM2410

4 2.3 ENTER THE PROGRAM MODE Directly after inserting the batteries, the Mobeye CM2410 switches to the program mode. First the GSM module establishes network connection. During this time the LED flashes green/red 2 sec. on/1 sec. off. Within 10-...

[Page 8] Mobeye CM2410

5 2.5 MOUNT THE GSM MODULE HOUSING TO THE CEILING Mount the housing in which the module is fixed to the desired place to the ceiling, using the plugs and screws which can be found inside the Ei Electronics box. Please refer to the manual of the ...

[Page 9] Mobeye CM2410

6 2.7 PERFORM A TEST After the previous steps, the GSM fire detector is operational. In order to execute a test, press the TEST & HUSH (or TEST & STUMM) button of the EI detector during a few seconds (this can take up to 5 seconds). T...

[Page 10] Mobeye CM2410

7 3. COMBINE OTHER EI DETECTORS AND A WIRELESS NETWORK 3.1 COMBINATIONS OF EI ELECTRONICS DETECTORS The CM2410 can be applied in various combinations: - A stand-alone GSM smoke or heat detector can be the combination of the Mobeye CM2410 and ...

[Page 11] Mobeye CM2410

8 4. USE OF EXTERNAL POWER SUPPLY Although the Mobeye CM2410 is designed to run on batteries, it is possible to use an external power supply. In this mode the module is always in connection with the GSM network and therefore always in program mo...

[Page 12] Mobeye CM2410

9 5. CONFIGURATION To program the Mobeye CM2410, the GSM module must have network connection. In case only batteries are used, first switch the unit to the program mode. Next send SMS commands for the configuration. All settings are stored and ...

[Page 13] Mobeye CM2410

10 5.3 PROGRAMMING THE SETTINGS BY SMS To program the settings by SMS text message: 1. Be sure the CM2410 is in program mode (please refer to 5.1). 2. Send an SMS text message with the (security) code and the command. 3. The green LED blin...

[Page 14] Mobeye CM2410

11 5.4 LIST OF SMS COMMANDS FOR CONFIGURATION Setting SMS Command Options Default value Change security code INSTCODE: 0000···9999 1111 Telephone number for alarm messages TEL1: …. TEL5: Empty Delete telephone nu...

[Page 15] Mobeye CM2410

12 6. POSSIBLE SETTINGS 6.1 PHONE NUMBERS The Mobeye CM2410 is able to send alarm messages to up to 5 phone numbers. The first telephone number (TEL1) belongs to the administrator. Only this number receives all system messages. The other phone...

[Page 16] Mobeye CM2410

13 6.3 ALARM TEXTS A unique alarm text can be programmed into the Mobeye CM2410. The user defined text has a maximum length of 20 characters. The default alarm text is Fire alarm! SMS command to change the text: TEXT1: example: 1111 TEX...

[Page 17] Mobeye CM2410

14 6.7 TEST MESSAGE The Mobeye CM2410 can send regular test SMS messages (keep alive) to the administrator (first phone number), to ensure the proper functioning of the unit. The timing of the test message is determined by the time of programmi...

[Page 18] Mobeye CM2410

15 7. REQUEST LIST OF THE SETTINGS, STATUS AND SIGNAL STRENGTH Several lists and status reports can be retrieved by sending an SMS text message, from any telephone. Before sending the request, make sure the unit is in the program mode (please re...

[Page 19] Mobeye CM2410

16 8. MOBEYE INTERNET PORTAL The Mobeye CM2410 sends GSM messages to the preset contact persons. It is also possible to connect the system to the Mobeye Internet Portal. In this secured internet environment the Mobeye CM2410 system(s) can be adm...

[Page 20] Mobeye CM2410

17 9. TECHNICAL MESSAGES AND STATUS FEEDBACK Technical messages In the event of technical issues the administrator (TEL1) receives an SMS message. Possible technical messages are: Message Reason Low batteries, external power supply OK...

[Page 21] Mobeye CM2410

18 Status feedback LED pattern Status Required action Blinking green, 1 second on / 1 second off Module not configured Configure at least one telephone number. 1 green flash every 3 seconds Module is switched on, powered by ...

[Page 22] Mobeye CM2410

19 Technical specifications GSM : Quad band EGSM, 850/900/1800/1900 MHz Batteries : 2* CR123 (lithium) Battery life in normal mode : >1 year Power consumption low power : ca. 50 μA stand-by / max. ca. 500 mA Ext. power c...

[Page 23] Mobeye CM2410

20 ...

[Page 24] Mobeye CM2410

...