[Page 1] GW Instek GPD-2303S

DC Power Supply GPD-X303S Series USER MANUAL GW INSTEK PART NO. 82PD-433S0M01 ISO-9001 CERTIFIED MANUFACTURER ...

[Page 2] GW Instek GPD-2303S

This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of Good Will compa...

[Page 3] GW Instek GPD-2303S

TABLE OF CONTENTS Table of Contents SAFETY INSTRUCTIONS ................................................... 5 OVERVIEW...................................................................... 10 Introduction...........................................

[Page 4] GW Instek GPD-2303S

GPD-X303S Series User Manual 4 Remote Connection Step...................... 44 Command Syntax ................................. 46 Error Messages .................................... 46 Command List...................................... 47 ...

[Page 5] GW Instek GPD-2303S

SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS This chapter contains important safety instructions that you must follow when operating the GPD- X303S series and when keeping it in storage. Read the following before any operation to insure your safety...

[Page 6] GW Instek GPD-2303S

GPD-X303S Series User Manual Do not dispose electronic equipment as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased. Safety Guidelines General Guideli...

[Page 7] GW Instek GPD-2303S

SAFETY INSTRUCTIONS Fuse WARNING • Fuse type: 100V/120V: T6.3A/250V, 220V/230V: T3.15A/250V • Make sure the correct type of fuse is installed before power up. • To ensure fire protection, replace the fuse only with the specified...

[Page 8] GW Instek GPD-2303S

GPD-X303S Series User Manual (Pollution Degree) EN 61010-1:2001 specifies the pollution degrees and their requirements as follows. The GPD-X303S series falls under degree 2. Pollution refers to “addition of foreign matter, solid, liquid, ...

[Page 9] GW Instek GPD-2303S

SAFETY INSTRUCTIONS Power cord for the United Kingdom When using the GPD-2303S/GPD-3303S/GPD-4303S series in the United Kingdom, make sure the power cord meets the following safety instructions. NOTE: This lead/appliance must only be wired b...

[Page 10] GW Instek GPD-2303S

GPD-X303S Series User Manual OVERVIEW This chapter describes the GPD-2303S/GPD- 3303S/GPD-4303S series in a nutshell, including its main features and front / rear panel introduction. After going through the overview, follow the Setup chapter...

[Page 11] GW Instek GPD-2303S

OVERVIEW Independent / Tracking Series / Tracking Parallel The three output modes of GPD-X303S series, independent, tracking series, and tracking parallel, can be selected through pressing the TRACKING key on the front panel. In the indepen...

[Page 12] GW Instek GPD-2303S

GPD-X303S Series User Manual Dynamic load When used in audio production lines, the power supply can provide a continuous or dynamic load using a jumper connector (JP101/JP401). When the jumper connectors are connected to the “ON” positi...

[Page 13] GW Instek GPD-2303S

OVERVIEW Series Lineup / Main Features Main Features Performance • Low noise: Temperature controlled cooling fan • Compact size, light weight Operation • Constant Voltage / Constant Current operation • Tracking Series ...

[Page 14] GW Instek GPD-2303S

GPD-X303S Series User Manual Principle of Operation Overview The power supply consists of the following. • AC input circuit • Transformer • Bias power supply including rectifier, filter, pre-regulator and reference voltage sour...

[Page 15] GW Instek GPD-2303S

OVERVIEW Auxiliary Rectifier The auxiliary rectifiers D1011~ D1014 provide bias voltage filtered by the capacitors C102 and C103, for the pre-regulators U101 and U102. They provide a regulated voltage for other modules. Main Rectifier Th...

[Page 16] GW Instek GPD-2303S

GPD-X303S Series User Manual Front Panel Overview VoltMeter Ammeter Memory Keys Voltage Knobs Current Knobs Parallel Keys CH1/CH3, CH2/ CH4(Beep) Keys Output Key Lock Key CH3 CV/CC Indicator CH3 Output CH1 CV/CC Indicator CH1 OutputCH2 Output C...

[Page 17] GW Instek GPD-2303S

OVERVIEW Control Panel Memory Keys Saves or recalls panel settings. Four settings, 1 ~ 4, are available. For save/recall details, see page41. CH1/CH2 GPD-2303S/2303S: Selects the output channel (CH1/CH2) for level adjustment. Fo...

[Page 18] GW Instek GPD-2303S

GPD-X303S Series User Manual Voltage Knobs Adjusts the output voltage level for the selected channel. Pressing the knob switches coarse and fine level setting. Current Knobs Adjusts the output current level for the selected channe...

[Page 19] GW Instek GPD-2303S

OVERVIEW Terminals Default Terminals European Terminals GND Terminal Accepts a grounding wire. CH1 CV/CC Indicator Indicates CH1 Constant Voltage or Constant Current state. CH1 Output Outputs CH1 voltage and current. ...

[Page 20] GW Instek GPD-2303S

GPD-X303S Series User Manual CH3 Overload Indicator Indicates when CH3 (3303S) output current is overloaded. CH3 Voltage Selector Selects CH3 output voltage for the GPD-3303S: 2.5V, 3.3V, or 5V. CH4 CV/CC Indicator Indicates C...

[Page 21] GW Instek GPD-2303S

OVERVIEW Rear Panel Overview USB Connector Accepts a USB slave connector for command-based remote control (page43). Power Cord / Fuse Socket The power cord socket accepts the AC mains: 115V/230V, 50/60Hz. For power up details, s...

[Page 22] GW Instek GPD-2303S

GPD-X303S Series User Manual CV/CC Crossover Characteristics Background The GPD-4303S, GPD-3303S and GPD-3303S automatically switch between constant voltage mode (CV) and constant current mode (CC), according to load condition. CV mode ...

[Page 23] GW Instek GPD-2303S

SETUP SETUP This chapter describes how to properly power up and configure the GPD-X303S series before operation. Power Up Select AC voltage Before powering up the power supply, select the AC input voltage from the rear panel. Conn...

[Page 24] GW Instek GPD-2303S

GPD-X303S Series User Manual Load Cable Connection GTL-104A 1. Turn the terminal counterclockwise and loosen the screw. 2. Insert the cable terminal. 3. Turn the terminal clockwise and tighten the screw. GTL-105A Insert t...

[Page 25] GW Instek GPD-2303S

SETUP Output On/Off Panel operation Pressing the Output key turns on all channel outputs. The key LED also turns on. Pressing the Output key again turns the output and the key LED off. Automatic output off Any of the following actio...

[Page 26] GW Instek GPD-2303S

GPD-X303S Series User Manual Switch between channels Panel operation Switching between channels only applies to GPD-4303S. Press the CH1/3 key to toggle between CH1 and CH3. The active channel will be shown on the channel indi...

[Page 27] GW Instek GPD-2303S

OPERATION OPERATION CH1/CH2 Independent Mode Background / Connection CH1 and CH2 outputs work independent of each other. Output rating 0 ~ 30V/0~3A for each channel Panel operation 1. Make sure the PARA/ INDEP and SER/INDEP keys...

[Page 28] GW Instek GPD-2303S

GPD-X303S Series User Manual Note: this diagram shows non-European terminals. 3. Set the CH1 output voltage and current. Press the CH1 key (LED turns on) and then use the Voltage and Current knob. By default, the Voltage and Cur...

[Page 29] GW Instek GPD-2303S

OPERATION CH3 Independent Mode Background / Connection For the GDP-3303S the CH3 rating is fixed at 2.5V/3.3V/5V, 3A. CH3 for the 4303S is variable: 0~5V,0~3A / 5.001~10V,0~1A . Output rating 3303S:2.5V/3.3V/5V,3A (fixed) ...

[Page 30] GW Instek GPD-2303S

GPD-X303S Series User Manual 2. 3303S: Select the output voltage, 2.5V/3.3V/5V using the CH3 voltage selector key. 4303S: Press the CH1/3 key to switch to CH3 (The CH3 indicator will light). Use the voltage and current knobs to set th...

[Page 31] GW Instek GPD-2303S

OPERATION CH4 Independent Mode Background / Connection The GPD-4303S has a rating of 5V/1A max. Output rating 5V/1A max No Tracking Series/Parallel CH4 does not have tracking series/parallel mode. The CH4 output is not affected by...

[Page 32] GW Instek GPD-2303S

GPD-X303S Series User Manual 3. To turn on the output, press the output key. The key LED turns on. CV → CC When the output value exceeds the set value, the C.V./C.C. indicator turns red. This indicates that CH3 has switched from c...

[Page 33] GW Instek GPD-2303S

OPERATION CH1/CH2 Tracking Series Mode Background Tracking series operation doubles the Voltage capacity of the GPD-X303S series by internally connecting CH1 (Master) and CH2 (Slave) in series and combining the output to a single channel. ...

[Page 34] GW Instek GPD-2303S

GPD-X303S Series User Manual Note: this diagram shows non-European terminals. 3. Press the CH2 key (LED turns on) and then use the Current knob to set the CH2 output current to the maximum level (3.0A). By default, the Voltage an...

[Page 35] GW Instek GPD-2303S

OPERATION Voltage level Double the reading on the CH1 Voltage meter. In the above case, the actual output is 20.0 x 2 = 40.0V. Current level CH1 meter reading shows the output Current. In the above case, 2.000A. (CH2 Current ...

[Page 36] GW Instek GPD-2303S

GPD-X303S Series User Manual 1. Press the SER/INDEP key to activate the tracking series mode. The key LED turns on. 2. Connect the load to the front panel terminals, CH1+ & CH2−. Use the CH1 (−) terminal as the common line ...

[Page 37] GW Instek GPD-2303S

OPERATION 5. To turn on the output (and LED), press the output key. 6. For the master (CH1) output level and CV/CC status, refer to the CH1 meter and indicator. Master (CH1) voltage level CH1 meter reading shows the outpu...

[Page 38] GW Instek GPD-2303S

GPD-X303S Series User Manual Slave (CH2) voltage level The CH1 meter reading shows the output voltage. In the above case, 20.0V. Slave (CH2) current level The CH2 meter reading shows the output current. In the above case, 3.000A. 3...

[Page 39] GW Instek GPD-2303S

OPERATION CH1/CH2 Tracking Parallel Mode Background / Connection Tracking parallel operation doubles the current capacity of the GPD-X303S series by internally connecting CH1 and CH2 in parallel and combining the output to a single channe...

[Page 40] GW Instek GPD-2303S

GPD-X303S Series User Manual 3. To turn on the output, press the output key. The key LED turns on. 4. The CH2 C.V./C.C. PAR. indicator turns red, indicating tracking parallel (PARA) mode. 5. Press the CH1 key (LED turns on...

[Page 41] GW Instek GPD-2303S

SAVE/RECALL SETUP SAVE/RECALL SETUP Save Setup Background The front panel settings can be stored into one of the four internal memories. Contents The following list shows the setup contents. • Independent / tracking series / tracking ...

[Page 42] GW Instek GPD-2303S

GPD-X303S Series User Manual Recall Setup Background The front panel settings can be recalled from one of the four internal memories. Contents The following list shows the setup contents. • Independent / tracking series / tracking par...

[Page 43] GW Instek GPD-2303S

REMOTE CONTROL REMOTE CONTROL Remote Control Setup Background The GPD-X303S is capable of being remotely controlled via a USB connection. Interface USB slave port, rear panel COM setting Set up the COM port inside the PC according to ...

[Page 44] GW Instek GPD-2303S

GPD-X303S Series User Manual Remote Connection Step Entering the remote control mode 1. Connect the USB cable to the slave port. 2. The connection will be automatically established, and the front panel shows a “USB…YES” message....

[Page 45] GW Instek GPD-2303S

REMOTE CONTROL 4. The power supply goes back to the local operation mode. 45 ...

[Page 46] GW Instek GPD-2303S

GPD-X303S Series User Manual Command Syntax Command format ISET<X>:<NR2>NL 12345 1: command header 2: output channel 3: separator 4: parameter 5: terminator(line feed) Output channel 1 (CH1) or 2 (CH2) Parameter Type De...

[Page 47] GW Instek GPD-2303S

REMOTE CONTROL e Command not allowed The entered command is not allowed in the circumstance. Example: trying to set CH2 output while in the tracking mode. f Undefined header The entered command does not exist, or the syntax is wrong. Com...

[Page 48] GW Instek GPD-2303S

GPD-X303S Series User Manual Command Details ISET<X>:<NR2> Description Sets the output current for the selected channel. X 1= CH1, 2= CH2, (4303S: 3 = CH3, 4= CH4) <NR2> Decimal number, range 0~3.200A Response time...

[Page 49] GW Instek GPD-2303S

REMOTE CONTROL VSET<X>? Description Returns the output voltage setting. X 1: CH1, 2: CH2, (4303S: 3: CH3, 4: CH4) Response time Minimum 10ms Example VSET1? Returns the CH1 voltage setting IOUT<X>? Description Returns t...

[Page 50] GW Instek GPD-2303S

GPD-X303S Series User Manual BEEP<Boolean> Description Turns the beep on or off. <Boolean> 0:off, 1:on Response time Minimum 10ms Example BEEP1 Turns on the beep OUT<Boolean> Description Turns on or off the outpu...

[Page 51] GW Instek GPD-2303S

REMOTE CONTROL Return parameter GW INSTEK,GPD-X3303,SN: xxxxxxxx, Vx.xx (Manufacturer, model name, serial number, firmware version) RCL<NR1> Description Recalls a panel setting. <NR1> 1 – 4: Memory 1 to 4 Response time...

[Page 52] GW Instek GPD-2303S

GPD-X303S Series User Manual Response time Minimum 10ms ERR? Description Checks the error status of the instrument and returns the last error message. Response time Minimum 10ms Contents See page 46 for the list of error messages. HE...

[Page 53] GW Instek GPD-2303S

FAQ FAQ Q1. I pressed the panel lock key but the output still turns on/off. A1. For safety reasons the output key is not affected by the panel key lock feature. Q2. The CH3 overload indicator turned on – is this an error? A2. No, it si...

[Page 54] GW Instek GPD-2303S

GPD-X303S Series User Manual APPENDIX Fuse Replacement Steps 1. Take off the power cord and remove the fuse socket using a minus driver. 2. Replace the fuse in the holder. Rating • 100V/120V:T6.3A/250V • 220V/230V:T...

[Page 55] GW Instek GPD-2303S

APPENDIX Specifications The specifications apply when the GPD-X303S series are powered on for at least 30 minutes under +20°C – +30°C. Output Ratings CH1/CH2 Independent 0 ~ 30V / 0 ~ 3A CH1/CH2 Series 0 ~ 60V / 0 ~ 3A CH1/CH2 ...

[Page 56] GW Instek GPD-2303S

GPD-X303S Series User Manual Voltmeter 32V full scale, 5 digits 0.4" LED display Program Accuracy Voltage: ± (0.03% of reading + 10mV) Current: ± (0.3% of reading + 10mA) Read back Accuracy Voltage: ± (0.03% of readin...

[Page 57] GW Instek GPD-2303S

APPENDIX Declaration of Conformity We GOOD WILL INSTRUMENT CO., LTD. (1) No.7-1, Zhongxing Rd., Tucheng Dist., xinbei City 236, Taiwan (2) No. 69, Lu San Road, Suzhou City (Xin Qu), Jiangsu Sheng, China declare, that the below mentioned p...

[Page 58] GW Instek GPD-2303S

GPD-X303S Series User Manual INDEX Automatic out off .................25 Banana plug ..........................24 Baud rate Remote control..................51 Beep setting Contents.............................25 Manual.....................

[Page 59] GW Instek GPD-2303S

INDEX 59 FAQ ....................................53 manual ...............................25 Remote ...............................50 Output voltage setting Manual...............................28 Remote control..................48 Over lo...