[Page 1] AquaStar 125B LP

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. Up...

[Page 2] AquaStar 125B LP

2 This well engineered, gas water heater has all the fea- tures a water heater should have: It operates on the principle of heating water instantaneously “on demand”. When a hot water faucet is opened, cold water flows through the coils of the h...

[Page 3] AquaStar 125B LP

3 D861_059 MINIMUM INSTALLATION CLEARANCES FROM COMBUSTIBLE AND NON COMBUSTIBLE MATERIALS FOR ALCOVE INSTALLATIONS FRONT VIEW SIDE VIEW AQUASTAR MODELS 125B / 125BL / 125BS / 125X MODEL 125B / 125B LOW PRESSURE / 125B SOLAR / 125X TOP (A) 12" F...

[Page 4] AquaStar 125B LP

4 If you are using the AquaStar for combined space heating and potable water heating (see schematic diagram below) , all piping and other components connected to the system must be suitable for potable water, (b) toxic chemicals such as those common...

[Page 5] AquaStar 125B LP

5 4. You must vent your heater. See section on Vent Pipe Connections, Page 5. 5. The appliance must be disconnected from the gas supply piping system during any pressure testing at pressures in excess of 1/2 Psig (3.5 kPa). The appliance must be isol...

[Page 6] AquaStar 125B LP

6 CLEARANCES The Aquastar 125 B is design certified for installation on a combustible wall and for installation in an alcove with the minimum clearances to combustible and non -combustible construction listed below A. Top 12 inches ( 305 mm) B. Front...

[Page 7] AquaStar 125B LP

7 The flue connection for the AquaStar 125B is 5 inches. However, in Canada, for installations at high altitude (2000- 4500 feet above sea level) a six inch flue is required. A 5" by 6" flue adaptor must be affixed to the flue collar of th...

[Page 8] AquaStar 125B LP

8 OPERATING INSTRUCTIONS Before proceeding with the operation of the heater make sure that the system is filled with water. Make sure the water heater drain plug is closed. See Figure 7 below. Fig. 7 - Water heater drain plug Open the cold water inle...

[Page 9] AquaStar 125B LP

9 LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above on this plate. 2. The Gas valve must be turned off by sliding the gas valve button to the far left under the OFF ( ) mark. 3. Wait five (5) minutes to clear out any gas. If you sme...

[Page 10] AquaStar 125B LP

10 TROUBLE SHOOTING Introduction The AquaStar 125 burners are activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient water flow volume to activate the burners at its minimum fl...

[Page 11] AquaStar 125B LP

11 6. Faulty thermocouple (part #8747202083) or electromagnet ) Unless these 2 parts are at least 8 to 10 years old, it is very unlikely that they are faulty. Before testing, reconfirm that #2 is absolutely correct, and that all connections are clean...

[Page 12] AquaStar 125B LP

12 PILOT LIGHT GOES OUT DURING OR IMMEDIATELY AFTER HOT WATER HAS BEEN USED 1. Gas pressure too low Very low gas pressure may be caused by low delivered gas pressure, a jammed gas regulator or undersized gas lines. If the gas lines are undersized, th...

[Page 13] AquaStar 125B LP

13 Fig. 11 - Diagram of AquaStar 125 B 5 11 1 4 9 10 1. Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Main gas burner 5. Pilot gas tubing 6. Gas valve 7. Pressure tap screw location 8. Gas control ...

[Page 14] AquaStar 125B LP

14 Fig. 12 - INTERIOR COMPONENTS DIAGRAM AND PARTS LIST ...

[Page 15] AquaStar 125B LP

15 Fig. 12 INTERIOR COMPONENTS DIAGRAM AND PARTS LIST 125B 1 Cover ¤ 8 705 421 025 2 Plastic collar ¤ 8 700 403 008 3 Temperature adjustment knob ¤ 8 702 000 111 4 Panel back ¤ 8 705 402 164 5 Draft divertor ¤ 8 705 505 354 6 Heat exchanger...

[Page 16] AquaStar 125B LP

Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP. 340 Mad River Park Vermont 05673 (U.S.A.) Phone 800-642-3111 Fax (802) 496-6924 WWW.CECHOT.COM VULCANO Termodomésticos S.A. Estrada de Cacia 3800 Cacia - PORTUGAL Re...