MULTIPOINT 1 Installation and User Instructions HS10U, HS15U. . Please read and understand these instructions before starting work. Please leave this leaflet with the user following installation PACK CONTENTS Heater, Factory fitted temperature and ...

[Page 2] Heatstore HS10U

2 Please read and understand these instructions prior to installing your Heatstore unvented water heater. Particular attention should be paid to the section headed IMPORTANT INSTALLATION POINTS. Following installation and commissioning the operation ...

[Page 3] Heatstore HS10U

MULTIPOINT 3 WARNING: IF WATER FLOWS FROM THE PRESSURE RELIEF VALVE OR TEMPERATURE / PRESSURE RELIEF VALVE THE ELECTRICITY SUPPLY MUST BE SWITCHED OFF IMMEDIATELY AND PROFESSIONAL ADVICE SOUGHT. 3 HS10U OR HS15U HOT COLD TUNDISH ...

[Page 4] Heatstore HS10U

4 2.0 INSTALLATION - GENERAL REQUIREMENTS: 2.1 National Wiring rules may contain restrictions concerning the installation of these units in bathrooms. 2.2 The unit should be vertically wall mounted. Fixing screws and rawplugs are supplied for this pu...

[Page 5] Heatstore HS10U

MULTIPOINT 5 3.0 INSTALLATION - ELECTRICAL REQUIREMENTS WARNING: This appliance must be earthed. It is suitable for a.c. supply only. Disconnect the electrical supply before removing the terminal cover. Installation m...

[Page 6] Heatstore HS10U

6 4.0 INSTALLATION - DISCHARGE PIPE REQUIREMENTS 4.1 The discharge outlet from the Pressure (expansion) Relief Valve and the Temperature/Pressure relief Valve must be connected to a discharge pipe. It is recommended that a tundish (not supplied) be i...

[Page 7] Heatstore HS10U

MULTIPOINT 7 6.0 MAINTENANCE - DESCALING Little maintenance is required, however in hard water areas the unit will require periodic descaling to ensure efficient operation. To descale the unit: 6.1 Switch off and disconnect the electrical supply. T...

[Page 8] Heatstore HS10U

8 7.0 MAINTENANCE - SAFETY VALVES The Temperature/Pressure Relief Valve and, if fitted, the Pressure (Expansion) Relief Valve should be regularly checked. Manually operate the valves by either twisting the cap or lifting the lever. Ensure water flows...

[Page 9] Heatstore HS10U

MULTIPOINT 9 9.0 SPARE PARTS The following comprehensive list of spare parts is available for your Heatstore water heater. Please refer to the Rating Label on the side of your heater before ordering to ensure the correct spare part is obtained. DO ...

[Page 10] Heatstore HS10U

10 10.0 FAULT FINDING Disconnect the electrical supply before removing the terminal cover. It is recommended that any service operations on this Heatstore heater are carried out by a competent person. NOTE: Use only Heatstore approved spare parts. Re...

[Page 11] Heatstore HS10U

MULTIPOINT 11 11.0 ACCESSORIES The heater can be used to supply several hot water outlets via conventional taps. It is not recommended for supplying a shower. Individual site demands should be considered when choosing capacity and the number of out...

[Page 12] Heatstore HS10U

12 GUARANTEE This water heater is guaranteed for a period of two years provided that: 1. It has been installed in accordance with these instructions and all the necessary inlet controls and safety valves have been fitted correctly. 2. Any valves or c...