Asus Pentium 4 Pedestal Server AP130-D User's Manual

Download or browse on-line these Operation & User’s Manual for Asus Pentium 4 Pedestal Server AP130-D Server.

Asus Pentium 4 Pedestal Server AP130-D Manual Information:

This manual for Asus Pentium 4 Pedestal Server AP130-D, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 40 pages, and the size of the file at download is 1.04 Mb. The document type is Operation & User’s Manual.

Download Manual

Summary of Contents:

[Page 1] Asus Pentium 4 Pedestal Server AP130-D

Pentium ® 4 Pedestal Server ® AP130-D User’s Manual ...

[Page 2] Asus Pentium 4 Pedestal Server AP130-D

2 Disclaimer/Copyrights No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except docume...

[Page 3] Asus Pentium 4 Pedestal Server AP130-D

3 Contents Disclaimer/Copyrights ................................................................. 2 ASUS Contact Information .......................................................... 6 FCC/CDC Statements ...............................................

[Page 4] Asus Pentium 4 Pedestal Server AP130-D

4 Contents 2.5 Install a Hard Disk Drive ................................................... 27 Remove the HDD/Floppy Cage ........................................... 27 Install the HDD ...................................................................

[Page 5] Asus Pentium 4 Pedestal Server AP130-D

5 ASUS Contact Information ASUSTeK COMPUTER INC. (Asia-Pacific) Address: 150 Li-Te Road, Peitou, Taipei, Taiwan 112 General Tel: +886-2-2894-3447 General Fax: +886-2-2894-3449 General Email: [email protected] Technical Support MB/Others (Tel): +886-2-...

[Page 6] Asus Pentium 4 Pedestal Server AP130-D

6 FCC/CDC Statements Federal Communications Commission Statement This device complies with FCC Rules Part 15. Operation is subject to the following two conditions: • This device may not cause harmful interference, and • This device must accept an...

[Page 7] Asus Pentium 4 Pedestal Server AP130-D

7 Safety Precautions Electrical Safety Operation Safety IMPORTANT • Before installing or removing signal cables, ensure that the power cables for the system unit and all attached devices are unplugged. • To prevent electrical shock hazard, discon...

[Page 8] Asus Pentium 4 Pedestal Server AP130-D

8 ...

[Page 9] Asus Pentium 4 Pedestal Server AP130-D

9 ASUS AP130-D Pedestal Server Introduction About This Manual “About This Manual” introduces the contents of this document. This part includes the target audience, chapter description, and conventions used. It also lists other sources of informat...

[Page 10] Asus Pentium 4 Pedestal Server AP130-D

10 Introduction: About This Manual Audience Contents This manual contains the following parts: 1. Introduction: About This Manual This part introduces the contents of this document. It includes the target audience, chapter description, and convention...

[Page 11] Asus Pentium 4 Pedestal Server AP130-D

ASUS AP130-D Pedestal Server 11 Conventions Symbols To make sure that you perform certain tasks properly, take note of the following symbols used throughout this manual. WARNING: Information to prevent injury to yourself when trying to complete a tas...

[Page 12] Asus Pentium 4 Pedestal Server AP130-D

12 Introduction: About This Manual System Package Contents The following checklist enumerates the components included in the standard system package. 1) ASUS AS11 chassis 2) ASUS P4B266-M motherboard 3) 200W ATX power supply 4) 52X CD-ROM drive 5) 1....

[Page 13] Asus Pentium 4 Pedestal Server AP130-D

13 ASUS AP130-D Pedestal Server This chapter describes the general features of the AP130-D server. It includes sections on front panel, rear panel, and internal features of the server. Chapter 1 System Overview ...

[Page 14] Asus Pentium 4 Pedestal Server AP130-D

14 Chapter 1: System Overview 1.1 System Features The ASUS AP130-D is a stylish barebone server featuring the ASUS P4B266-M motherboard. The server supports the Intel ® Pentium ® 4 478/ Northwood processor, and includes the latest I/O, audio, an...

[Page 15] Asus Pentium 4 Pedestal Server AP130-D

ASUS AP130-D Pedestal Server 15 1.2 Front Panel Features The AP130-D front panel is designed with a door secured by a keylock. When locked, the door prevents unauthorized access to the front panel components. Front Panel Door Keylock Power Switch CD...

[Page 16] Asus Pentium 4 Pedestal Server AP130-D

16 Chapter 1: System Overview 1.3 Rear Panel Features The AP130-D rear panel includes the external I/O ports. The following picture shows the cable connectors and the devices that you connect to the ports. Voltage Selector The switching power supply...

[Page 17] Asus Pentium 4 Pedestal Server AP130-D

ASUS AP130-D Pedestal Server 17 1.4 Internal Features The standard components inside the AP130-D server include the motherboard, power supply, floppy and CD-ROM drives, and cables. The picture below shows the standard components of the server. 1. Po...

[Page 18] Asus Pentium 4 Pedestal Server AP130-D

18 Chapter 1: System Overview ...

[Page 19] Asus Pentium 4 Pedestal Server AP130-D

19 ASUS AP130-D Pedestal Server This chapter describes the hardware setup procedures that you have to perform when installing system components. Chapter 2 Hardware Setup ...

[Page 20] Asus Pentium 4 Pedestal Server AP130-D

20 Chapter 2: Hardware Setup 2.1 Remove the Chassis Cover Unlock the side cover Two thumbscrews secure the removable side panel cover. Turn these screws counter-clockwise to release the cover. The screws are attached to the cover. Do pull out the sc...

[Page 21] Asus Pentium 4 Pedestal Server AP130-D

ASUS AP130-D Pedestal Server 21 Placement Direction When installing the motherboard, make sure that you place it into the chassis correctly. The edge with the external ports goes to the rear part of the chassis. Motherboard Screws Place eight (8) scr...

[Page 22] Asus Pentium 4 Pedestal Server AP130-D

22 Chapter 2: Hardware Setup 2.3 Install a CPU The 478-pin Zero Insertion Force (ZIF) socket on the P4B266-M motherboard supports an Intel Pentium 4 processor. This section tells you how to install a CPU. Refer to the motherboard user guide for more...

[Page 23] Asus Pentium 4 Pedestal Server AP130-D

ASUS AP130-D Pedestal Server 23 Unlock the CPU Socket Unlock the socket by pressing the lever sideways then lifting it up to a 90°-100° angle. Insert the CPU 1. Position the CPU above the socket such that its marked corner matches the base of the s...

[Page 24] Asus Pentium 4 Pedestal Server AP130-D

24 Chapter 2: Hardware Setup 1. Align and snap the hooks of a retention bracket into the holes of the retention module base. Make sure that the arrow on the bracket points inward. 2. Follow step 1 to install the other bracket. 3. When attached to th...

[Page 25] Asus Pentium 4 Pedestal Server AP130-D

ASUS AP130-D Pedestal Server 25 4. Orient the fan heatsink assembly with the fan cable nearest the CPU fan connector on the motherboard (marked CPU_FAN). 5. Carefully place the fan heatsink assembly on top of the CPU. Make sure that the heatsink perf...

[Page 26] Asus Pentium 4 Pedestal Server AP130-D

26 Chapter 2: Hardware Setup 2.4 Install System Memory The motherboard has two Dual Inline Memory Module (DIMM) sockets that support up to 2GB system memory using PC2100/ PC1600 DDR DIMMs. Install a DIMM 1. Unlock a DIMM socket by pressing the retai...

[Page 27] Asus Pentium 4 Pedestal Server AP130-D

ASUS AP130-D Pedestal Server 27 2.5 Install a Hard Disk Drive 1. Remove the screw that secures the HDD/floppy cage. Make sure to disconnect the floppy cable from the floppy disk before removing the cage out of the chassis. 2. Press the retaining clip...

[Page 28] Asus Pentium 4 Pedestal Server AP130-D

28 Chapter 2: Hardware Setup Install the HDD 1. Insert the HDD into the cage (label side up) until the holes on the HDD align with the holes on the cage. 2. Secure the HDD with four screws (two on each side). 3. Replace the cage into the chassis. Co...

[Page 29] Asus Pentium 4 Pedestal Server AP130-D

ASUS AP130-D Pedestal Server 29 2.6 Replace the Cover Re-install the Cover 1. Position the cover in place, aligning the tabs on the inner side of the cover to the rail holes on the chassis edge. 2. Slide the cover toward the front panel until it fits...

[Page 30] Asus Pentium 4 Pedestal Server AP130-D

30 Chapter 2: Hardware Setup ...

[Page 31] Asus Pentium 4 Pedestal Server AP130-D

31 ASUS AP130-D Pedestal Server This chapter tells how to get started with the AP130-D server. Powering up the server basically includes connecting the cables and turning power on. Chapter 3 Powering Up ...

[Page 32] Asus Pentium 4 Pedestal Server AP130-D

32 Chapter 3: Powering Up 3.1 Getting Started Make sure that you have completed the basic system installations in Chapter 2, then follow these steps to start up the server. Connect a Monitor Connect a monitor by plugging hte monitor cable to the vid...

[Page 33] Asus Pentium 4 Pedestal Server AP130-D

33 ASUS AP130-D Pedestal Server This appendix gives information on the 200W switching power supply that comes with the AP130-D server. Appendix A Power Supply ...

[Page 34] Asus Pentium 4 Pedestal Server AP130-D

34 Appendix A: Power Supply A.1 General Description The server comes with a 200W ATX power supply with universal AC input that includes PFC and ATX-compliant output cables and connectors. The power supply has an internal cooling fan. The power suppl...

[Page 35] Asus Pentium 4 Pedestal Server AP130-D

ASUS AP130-D Pedestal Server 35 Input Characteristics A.2 Specifications Output Characteristics Over-Voltage Protection (OVP) Input Voltage Range Min Nom Max Range 1 90V 115V 140V Range 2 180V 230V 264V Input Frequency Range 43 Hz to 66 Hz Maximum In...

[Page 36] Asus Pentium 4 Pedestal Server AP130-D

36 Appendix A: Power Supply ...

[Page 37] Asus Pentium 4 Pedestal Server AP130-D

37 ASUS AP130-D Pedestal Server This appendix lists the common problems that you may encounter while using the AP130-D server. It lists the possible causes of the problems and offers solutions. You may refer to this part and try to solve simple probl...

[Page 38] Asus Pentium 4 Pedestal Server AP130-D

38 Appendix B: Troubleshooting B.1 Simple Fixes The power LED on the server and/or the monitor do not light up 1. Make sure that the 115V/230V voltage selector switch is set to the correct voltage supply in your area. 2. Check the power cable connec...

[Page 39] Asus Pentium 4 Pedestal Server AP130-D

ASUS AP130-D Pedestal Server 39 The system continuously beeps after it was turned on 1. Check the memory modules and make sure you installed the DIMMs the system supports. 2. Make sure that the DIMMs are properly installed on the sockets. The message...

[Page 40] Asus Pentium 4 Pedestal Server AP130-D

40 Appendix B: Troubleshooting ...