[Page 1] HealthyAir HA-CMP-G2-R

Ceiling Mount Air Purification System HA-CMP-G2-R/HA-CMP-G2-OV Owner’s Manual Table of Contents HealthyAir® Series 1219 Filters 1 Important Safety Instructions 2 Technical Specifications 3 Packaging Reference 4 Compo...

[Page 2] HealthyAir HA-CMP-G2-R

1 HealthyAir ® HA-CMP-G2-R & HA-CMP-G2-OV Ceiling Mount Air Purification Systems with HealthyAir ® Series 1219 Filters HA-PF-1219 HA-EH-1219 HA-CC-1219 at www.HealthyAir.com ...

[Page 3] HealthyAir HA-CMP-G2-R

2 WARNING Cut power to the unit before servicing or replacing filters. Failure to do so could result in serious personal injury and death. I. Important Safety Instructions Read the Owner's Manual and Important Safety I...

[Page 4] HealthyAir HA-CMP-G2-R

3 II. Technical Specifications Model Number HA-CMP-G2-W-R HA-CMP-G2-W-OV Rated Voltage 120V/60HZ Power Consumption 200W Weight 65 lbs. (29.5 kg) Base Dimensions 24x24x15.4 in. (600×600×392 mm) Air Flow Rate 550 c...

[Page 5] HealthyAir HA-CMP-G2-R

4 III. Packaging Reference The Ceiling Mount Air Purification System is shipped in one (1) carton, that contains the following: • (1) Air Purification Unit • (3) Filters • (4) Eye Bolts • (1) Remote Control • (1) Manual...

[Page 6] HealthyAir HA-CMP-G2-R

5 IV. Component Reference 11. Eye Bolt 12. Capacitor 13. HV PCB 14. PCB Board 15. Wiring Box 16. Safety Switch 17. Fuse 18. Control Panel 19. Control Panel Display 20. Remote Control 1. Face Plate 2. ...

[Page 7] HealthyAir HA-CMP-G2-R

6 V. Installation Instructions 5.1 Installation of Eye Bolts 5.1.1 Carefully place the unit face down, as shown in Fig. 1. 5.1.2 Screw the four (4) Eye Bolts into the respective rivet nuts, located at the four corners of the Bottom P...

[Page 8] HealthyAir HA-CMP-G2-R

7 V. Installation Instructions 5.2 Optimal Unit Location The standard HealthyAir ® Ceiling Mount Air Purification System recirculates air back into the facility, after it is purified in a 3-stage filtration process. Note: Locate and ...

[Page 9] HealthyAir HA-CMP-G2-R

8 V. Installation Instructions 5.3 Mounting to I-Beam Ceiling Structure Using Fig. 3 as a guide, install the HealthyAir ® Ceiling Mount Air Purification System in accordance with all applicable building and mechanical codes. Fig....

[Page 10] HealthyAir HA-CMP-G2-R

9 V. Installation Instructions 5.5 Outside Vent Application - Model HA-CMP-G2-OV The HealthyAir ® Ceiling Mount Air Purification Outside Vent System, model HA-CMP-G2-OV, is designed to enable filtered air to be discharged from the faci...

[Page 11] HealthyAir HA-CMP-G2-R

10 V. Installation Instructions 5.5 Outside Vent Application - Model HA-CMP-G2-OV 5.5.3 Install the HealthyAir ® Ceiling Mount Air Purification Outside Vent System in accordance with the instructions provided in Sections 5.1-5.4 herei...

[Page 12] HealthyAir HA-CMP-G2-R

11 V. Installation Instructions 5.6 Converting Recirculating Vent to Outside Vent (Optional) The HealthyAir ® Ceiling Mount Air Purification Recirculating Vent System can be converted to a HealthyAir ® Ceiling Mount Air Purification O...

[Page 13] HealthyAir HA-CMP-G2-R

12 V. Installation Instructions 5.6 Converting Recirculating Vent to Outside Vent (Optional) Fig. (8) – Opening Face Plate 5.6.4 Locate and remove the eight (8) Hex Nuts that are preinstalled on the back of the Face Plate, as ...

[Page 14] HealthyAir HA-CMP-G2-R

13 V. Installation Instructions 5.6 Converting Recirculating Unit to Outside Vent (Optional) 5.6.5 Locate the two (2) Outlet Vent Cover Plates, shown in Fig. 10. Fig. (10) –Outlet Vent Cover Plates 5.6.6 Install the Out...

[Page 15] HealthyAir HA-CMP-G2-R

14 V. Installation Instructions 5.6 Converting Recirculating Unit to Outside Vent (Optional) 5.6.7 Reinstall the eight (8) Hex Nuts to secure the Outlet Vent Cover Plates on the Face Plate. 5.6.8 Close the Face Plate and reinstal...

[Page 16] HealthyAir HA-CMP-G2-R

15 VI. Electrical Wiring Instructions Note: The HealthyAir ® Ceiling Mount Air Purification system must be hard wired when recess mounted. All wiring must comply with applicable electrical codes and ordinances. 6.1 Instructions to Hard...

[Page 17] HealthyAir HA-CMP-G2-R

16 VII. Electrical Wiring Schematic Fig. (14) – Electrical Wiring Schematic ...

[Page 18] HealthyAir HA-CMP-G2-R

17 VIII. Operation Guidelines 8.1 Power Supply and Activation The input power to the unit should include an external circuit breaker with a 2.5 AMP Maximum Current Rating. 8.1.1 Provide power to the unit by turning the circuit breaker...

[Page 19] HealthyAir HA-CMP-G2-R

18 VIII. Operation Guidelines 8.2 System Controls • TIMER To set the timer manually, press the TIMER button once for every hour you wish to run the machine (i.e. press TIMER once for 1-hour of run time, press TIMER twice for 2-hour...

[Page 20] HealthyAir HA-CMP-G2-R

19 IX. Filter Replacement 9.1 Replacement Filter The HealthyAir ® Ceiling Mount Air Purification System (HA-CMP-G2) utilizes the HealthyAir ® Series 1219 Replacement Filters, as follows: • HealthyAir ® Pre-Filter Model No...

[Page 21] HealthyAir HA-CMP-G2-R

20 IX. Filter Replacement 9.2 Filter Change Fig. (16) – Opening Face Plate to Access Filters 9.2.3 Unscrew and remove the four (4) Thumb Screws, which secure the Filter Housing, as shown in Fig. 17. 9.2.4 Gently pull t...

[Page 22] HealthyAir HA-CMP-G2-R

21 IX. Filter Replacement 9.2 Filter Change Fig. (17) –Lowering Filter Housing to Access Filters 9.2.6 Install a new set of HealthyAir ® Series 1219 Replacement Filters into the Filter Housing, as follows and as show...

[Page 23] HealthyAir HA-CMP-G2-R

22 IX. Filter Replacement 9.2 Filter Change 9.2.7 Push the Filter Housing up to reinsert it within the unit. While holding the Filter Housing in place, screw in the four (4) Thumb Screws to secure it the housing to the body of the unit....

[Page 24] HealthyAir HA-CMP-G2-R

23 IX. Filter Replacement 9.3 Filter Change Indicator Light Reset Once the filters have been replaced and the unit is turned on, the Filter Change indicator light may continue to flash. To reset the filter change timer and deactivate the...

[Page 25] HealthyAir HA-CMP-G2-R

24 X. Maintenance Caution: The HV Contact Spring may store a slight charge even after the unit is powered off. Avoid direct contact with the HV Contact Spring after the filters have been removed from the Filter Housing. 10.1 Cleaning the...

[Page 26] HealthyAir HA-CMP-G2-R

25 XI. Basic Service and Troubleshooting The Basic Service Guide should cover most performance issues. If you continue to experience issues after referring to this list, please contact Healthy Air Inc. 11.1 Air Purification System is Inop...

[Page 27] HealthyAir HA-CMP-G2-R

26 XI. Basic Service and Troubleshooting 11.3 Air Purification System Power is On but Fan Inoperable If the unit powers on but the fan fails to operate, the issue may be the result of a faulty motor or board and will require service by ...

[Page 28] HealthyAir HA-CMP-G2-R

27 XI. Basic Service and Troubleshooting 11.5 Filter Change Indicator Light Flashing If the unit is properly functioning and the Filter Change indicator light is flashing, the default filter change timer has expired, and the filter sh...

[Page 29] HealthyAir HA-CMP-G2-R

28 XI. Basic Service and Troubleshooting 11.7 Remote Control is Inoperable If the Remote Control fails to operate the unit, the issue may be the result of one of the following causes and may require replacement parts or service by th...

[Page 30] HealthyAir HA-CMP-G2-R

29 Healthy Air Inc. 1-Year Limited Warranty Healthy Air Inc. only makes this 1-Year Limited Warranty ("Limited Warranty") to the original retail purchaser who submits the enclosed Warranty Registration Card within 10 days of purch...

[Page 31] HealthyAir HA-CMP-G2-R

30 Healthy Air Inc. 1-Year Limited Warranty Product Registration Form Please complete the Product Registration Form and submit it to Healthy Air Inc. within ten (10) days of the original purchase, to validate 1-Year Limited Warranty. Su...