Clifford intelliGuard 750 Installation Manual

Download or browse on-line these Installation Manual for Clifford intelliGuard 750 Car Alarm.

Clifford intelliGuard 750 Manual Information:

This manual for Clifford intelliGuard 750, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 49 pages, and the size of the file at download is 0.62 Mb. The document type is Installation Manual.

Download Manual

Summary of Contents:

[Page 1] Clifford intelliGuard 750

© 2004 Directed Electronics, Inc. Vista, CA N909621 08-04 installation guide ...

[Page 2] Clifford intelliGuard 750

Bitwriter™, Code Hopping™, Directed ® , Doubleguard ® , ESP™, FailSafe ® , Ghost Switch™, Learn Routine™, Nite- Lite ® , Nuisance Prevention Circuitry ® , NPC ® , Revenger ® , Silent Mode™, Soft Chirp ® , Stinger ® , Valet ® , V...

[Page 3] Clifford intelliGuard 750

contents what is included . . . . . . . . . . . . . .4 transmitter configurations . . . . . .4 transmitter functions . . . . . . . . . .5 standard configuration . . . . . . .5 primary harness wire connection guide . . . . . . . . . . . . .6 prim...

[Page 4] Clifford intelliGuard 750

www.directed.com 4 what is included z One control module z One 18-pin main wiring harness z Two five-button transmitters z One four-pin immobilizer harness z One XHF antenna/receiver z One 6-pin secondary harness with harness z One pre-wired blue st...

[Page 5] Clifford intelliGuard 750

© 2004 directed electronics, inc. 5 transmitter functions This system uses computer-based code learning to learn the transmitter buttons. This makes it possible to assign any transmitter button to any system function. The trans- mitter initially com...

[Page 6] Clifford intelliGuard 750

www.directed.com 6 Button three times, then Button These buttons adjust the dual-zone omnisensor. Button three times, then Button These buttons adjust the optional dual-zone radar sensor. primary harness wire connection guide primary harness wiring...

[Page 7] Clifford intelliGuard 750

© 2004 directed electronics, inc. 7 primary harness wiring guide This guide describes in detail the connection of each wire. Also included are possible appli- cations of each wire. This system was designed with the ultimate in flexibility and securi...

[Page 8] Clifford intelliGuard 750

www.directed.com 8 h1/4 violet/black tach input This wire monitors engine speed for BlackJax and door locks. Connect it to the nega- tive side of the coil or to the uncommon color of any fuel injector. If installing with Intellistart, only connect th...

[Page 9] Clifford intelliGuard 750

© 2004 directed electronics, inc. 9 h1/10 red (+) 12v constant Before connecting the RED wire, remove the supplied fuse. Connect to the battery pos- itive terminal (be sure to use the supplied fuse holder and a 5 amp fuse) or the con- stant (+) 12V ...

[Page 10] Clifford intelliGuard 750

www.directed.com 10 h1/17 orange ground when armed This wire provides a (-) ground output as long as the system is armed and will cease when the system is disarmed. This output can be used for an additional immobilizer relay or to control additional ...

[Page 11] Clifford intelliGuard 750

© 2004 directed electronics, inc. 11 h2/3 black/white domelight supervision input (87) This wire determines the output of the BLACK/WHITE H1/15 wire on the main 18-pin harness. If the vehicle has a negative domelight circuit, ground this wire; if th...

[Page 12] Clifford intelliGuard 750

www.directed.com 12 ultrasecure immobilizer The UltraSecure immobilizer circuit in this G5 system is a unique new design that incorporates the immobilizer security of Clifford without the possibility of failure due to power loss that could potentiall...

[Page 13] Clifford intelliGuard 750

© 2004 directed electronics, inc. 13 type A: positive (+) 12-volt pulse The system can control Type A door locks directly, with no additional parts. The switch will have three wires on it; one will test (+)12 volt constantly. The others will alterna...

[Page 14] Clifford intelliGuard 750

www.directed.com 14 type B: negative (-) pulse This system is common in many Toyotas, Nissans, Hondas, and Saturns, as well as Fords with keyless entry systems (some other Fords also use Type B). Most European Ford vehicles with (-) negative pulse lo...

[Page 15] Clifford intelliGuard 750

© 2004 directed electronics, inc. 15 type C: reversing polarity Interfacing with a reversing polarity system requires either two relays or one 451M (not included). It is critical to identify the proper wires and locate the master switch to interface...

[Page 16] Clifford intelliGuard 750

www.directed.com 16 type D: after-market actuators In order for this system to control one or more after-market actuators, a 451M or two relays (optional) are required. Vehicles without factory power door locks require the installation of one actuato...

[Page 17] Clifford intelliGuard 750

© 2004 directed electronics, inc. 17 type E: mercedes-benz and audi (1985 & newer) Type E door locks are controlled by an electrically activated vacuum pump. Some Mercedes and Audis use a Type D system. Test by locking doors from the passenger k...

[Page 18] Clifford intelliGuard 750

www.directed.com 18 type F: one-wire system Type F door locks usually require a negative pulse to unlock and cutting the wire to lock the door. In some vehicles, these functions are reversed. Type F door locks are found in late-model Nissan Sentras, ...

[Page 19] Clifford intelliGuard 750

© 2004 directed electronics, inc. 19 type G: positive (+) multiplex The door lock switch or door key cylinder may contain either one or two resistors. When interfacing with this type of door lock system, two relays or a 451M must be used. Single-Res...

[Page 20] Clifford intelliGuard 750

www.directed.com 20 type H: negative (-) multiplex The door lock switch or door key cylinder may contain either one or two resistors. When interfacing with this type of door lock system, two relays or a 451M must be used. Single-Resistor Type If one ...

[Page 21] Clifford intelliGuard 750

© 2004 directed electronics, inc. 21 peripheral plug-in harnesses super bright blue led, 2-pin white plug The super bright LED operates at (+) 2V DC. Make sure the LED wires are not short- ed to ground as the LED will be damaged. Multiple LEDs can b...

[Page 22] Clifford intelliGuard 750

www.directed.com 22 blue and orange wires, zone 3 zone 8 These wires are multiplex inputs. If a (-) input of less than 0.8 seconds is supplied to either wire, the Warning Zone response will occur. A (-) input of longer than 0.8 sec- onds to either wi...

[Page 23] Clifford intelliGuard 750

© 2004 directed electronics, inc. 23 arming/disarming diagnostics The systems microprocessor monitors and reports all active and violated zones when arming and disarming the system. arming Zones that are triggered at the time the system is armed are...

[Page 24] Clifford intelliGuard 750

www.directed.com 24 system status chirps remote siren silencing While the siren is sounding, press the arm/disarm button once to silence the siren but leave the system in the armed state. To disarm the system, press the arm/disarm but- ton a second t...

[Page 25] Clifford intelliGuard 750

© 2004 directed electronics, inc. 25 system features programming This system has many features that can be programmed to accommodate the user's personal preferences and make system installation easier. They are listed in two pro- gramming grids...

[Page 26] Clifford intelliGuard 750

www.directed.com 26 manual programming instructions Be sure to document changes by taking note of all feature changes made in program- ming mode. To enter the User Selectable Features programming: 1. Ignition on - Turn the ignition to the run positio...

[Page 27] Clifford intelliGuard 750

© 2004 directed electronics, inc. 27 user selectable features NNOOTTEE:: Factory default settings are shown in bboolldd . * This feature is only available with optional IntelliStart connected. ** This feature is only available with optional SmartWi...

[Page 28] Clifford intelliGuard 750

www.directed.com 28 user selectable features descriptions - column one add new remote (only applicable with Radar 2 remote) z Auto-learn new remote controls to the system in the standard button configu- ration. For more information, see programming n...

[Page 29] Clifford intelliGuard 750

© 2004 directed electronics, inc. 29 second unlock - off/on z Off: Second unlock output is pulsed at the same time as the unlock output when the system is disarmed. z On: Second unlock output is active when the arm/disarm button is pressed within 10...

[Page 30] Clifford intelliGuard 750

www.directed.com 30 panic off/on z Off: The panic feature is not available. z On: The panic feature is available. auto start setting - off/battery only/temp only/battery and temp NNOOTTEE:: This feature is only available with the IntelliStart option....

[Page 31] Clifford intelliGuard 750

© 2004 directed electronics, inc. 31 silent mode z The transmitter channel programmed into this feature will arm/disarm the system, but the siren will not chirp. remote valet z The transmitter channel programmed into this feature will make the syste...

[Page 32] Clifford intelliGuard 750

www.directed.com 32 installer selectable features To enter the Installer Selectable Features grid follow the instructions for the User Selectable Features with the exception of step 4. Perform step 4 as described below to enter the Installer Selectab...

[Page 33] Clifford intelliGuard 750

© 2004 directed electronics, inc. 33 installer selectable features descriptions - column one lock pulse - single/double z Single: One door lock pulse will be output when the system arms. z Double: Two door lock pulses will be output when the system ...

[Page 34] Clifford intelliGuard 750

www.directed.com 34 installer selectable features descriptions - column two accessory output a programming The auxiliary accessory output wire (RED/WHITE) can be programmed for several dif- ferent types of outputs. z P1 0.8 seconds: The pulsed output...

[Page 35] Clifford intelliGuard 750

© 2004 directed electronics, inc. 35 accessory output b timer duration z Start Timer: Press the arm/disarm button; the siren will chirp to signal the start of the timer duration setting. z Stop Timer: Press the arm/disarm button; the siren will chir...

[Page 36] Clifford intelliGuard 750

www.directed.com 36 horn output - pulsed/latched z Pulsed: H2/9 YELLOW/WHITE wire will generate a pulsing (-) output when the alarm is in full trigger. When arming and disarming the output does not operate. z Latched: H2/9 YELLOW/WHITE wire will gene...

[Page 37] Clifford intelliGuard 750

© 2004 directed electronics, inc. 37 Note #4: RPM programming z Drive the vehicle to an open area and allow the engine to warm up until the engine RPM drops to normal idle speed. z Place the engine in park or neutral and set the parking brake. z Ent...

[Page 38] Clifford intelliGuard 750

www.directed.com 38 z PIN Code Confirmation Procedure Begin this procedure within 15 seconds of finishing the programming sequence or the new code will not be set. 1. Turn on the ignition. 2. Enter the new PIN code. 3. Press and hold for three secon...

[Page 39] Clifford intelliGuard 750

© 2004 directed electronics, inc. 39 smart power up II The Smart Power Up II feature ensures that when the security system is powered back up after being disconnected, the system will resume the same state it was in before power was lost. For exampl...

[Page 40] Clifford intelliGuard 750

www.directed.com 40 auto-immobilization feature Immobilizer circuits automatically activate after 30 seconds. NNOOTTEE:: H1/17 orange ground when armed will not activate during Auto- Immobilization. auto-immobilization sequence 1. Turn ignition off...

[Page 41] Clifford intelliGuard 750

© 2004 directed electronics, inc. 41 1. Ignition on. z System sees input on Zone 7 ignition input. 2. Door Open & Close. z System sees input on H1/8 or H1/9 Door trigger input. 3. Press and release brake pedal. a. System sees (+) input on H2/11 ...

[Page 42] Clifford intelliGuard 750

www.directed.com 42 5. Turn Ignition Off, siren chirps 3 times as confirmation of exiting programming. NNOOTTEE:: If ignition remains on after entering PIN code and no action for 10 seconds, unit will automatically exit programming mode without chirp...

[Page 43] Clifford intelliGuard 750

© 2004 directed electronics, inc. 43 3. To test Primary (full trigger) zone. z Press of the remote control. z Siren will chirp 2 times. z Hit vehicle. z Siren chirps 1 time if hit hard enough to activate sensor. 4. Adjust Primary zone z Press of t...

[Page 44] Clifford intelliGuard 750

www.directed.com 44 second unlock feature ON: System will monitor disarm channel for 10 seconds after disarm, if disarm chan- nel is again transmitted within 10 seconds, H2/12 Blue/white will generate the programmed unlock output. OFF: H2/12 Blue/whi...

[Page 45] Clifford intelliGuard 750

© 2004 directed electronics, inc. 45 wiring reference guide TM TM Immobilizer Harness Immobilizer Jumper RF Port Omnisensor Port Mux Sensor Port Proximity Sensor Port CliffNet Wizard Port Smart Self- Powered Siren Power 6-Pin Harness 18-Pin Harness...

[Page 46] Clifford intelliGuard 750

www.directed.com 46 BLACK - Ground BROWN - Speaker Output 1 GRAY - (-) Hood Trigger Input Zone 6 VIOLET/BLACK - Tach Input GREEN - (-) Door Trigger Input - Zone 4 VIOLET - (+) Door Trigger Input - Zone 4 BLUE - (-) Trunk Trigger Input - Zone 5 WHITE...

[Page 47] Clifford intelliGuard 750

© 2004 directed electronics, inc. 47 BLACK/WHITE - Domelight Supervision Input (87) PINK/BLACK - (-) Accessory Output C (200mA) YELLOW/WHITE - (-) Horn Honk Output (200mA) BLUE/WHITE - Second Unlock Output (200mA) BROWN/WHITE - Brake Light Output 6...

[Page 48] Clifford intelliGuard 750

www.directed.com 48 ...

[Page 49] Clifford intelliGuard 750

© 2004 directed electronics, inc. 49 notes ________________________________________ ________________________________________ ________________________________________ ________________________________________ ________________________________________ _...