[Page 1] Dell H310

Dell PowerEdge RAID Controller (PERC) H310, H710, H710P, and H810 User’s Guide Regulatory Model: UCSA-801, UCSB-800, UCSM-800, UCPA-801, UCPB-800, UCPM-800, and UCPE-800 ...

[Page 2] Dell H310

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARN...

[Page 3] Dell H310

Contents 1 Overview.......................................................................................................................................9 Supported Operating Systems......................................................................

[Page 4] Dell H310

Recovering Cache Data................................................................................................................................... 23 Battery Transparent Learn Cycle..................................................................

[Page 5] Dell H310

Break Mirror.....................................................................................................................................................46 Managing Preserved Cache.................................................................

[Page 6] Dell H310

CacheCade Virtual Disk Management............................................................................................................. 62 Creating CacheCade Virtual Disks...........................................................................

[Page 7] Dell H310

Firmware Fault State Error Message............................................................................................................... 75 Foreign Configuration Found Error Message...............................................................

[Page 8] Dell H310

RAID Terminology...................................................................................................................................................85 Disk Striping..........................................................................

[Page 9] Dell H310

1 Overview The Dell PowerEdge RAID Controller (PERC) H310, H710, H710P, and H810 family of storage controller cards has the following characteristics: • Complies with serial-attached SCSI (SAS) 2.0 providing up to 6 Gb/sec throughput. • Supports...

[Page 10] Dell H310

Specification H310 H710 H710P H810 Maximum number of spans per Disk Group 8 8 8 8 Maximum number of Virtual Disks per Disk Group 16 16 16 16 Online Capacity Expansion Yes Yes Yes Yes Dedicated and Global Hot Spares Yes Yes Yes Yes Hot Swap Devi...

[Page 11] Dell H310

Contacting Dell NOTE: Dell provides several online and telephone-based support and service options. If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product cat...

[Page 12] Dell H310

12 ...

[Page 13] Dell H310

2 Features Some of the features discussed for PowerEdge RAID Controller (PERC) H310, H710, H710P, and H810 cards are: • Physical Disk Power Management • Types of Virtual Disk Initialization • Consistency Checks • Disk Roaming • Fast Path �...

[Page 14] Dell H310

NOTE: There is a delay to I/O operations when a configured disk is being spun up. Types Of Virtual Disk Initialization You can initialize the virtual disks as described in the following sections: CAUTION: The initializing virtual disks task erases th...

[Page 15] Dell H310

Disk Roaming Disk roaming is moving the physical disks from one cable connection or backplane slot to another on the same controller. The controller automatically recognizes the relocated physical disks and logically places them in the virtual disk...

[Page 16] Dell H310

Table 2. FastPath Eligibility Across Supported RAID Levels RAID 0 RAID 1 RAID 5 RAID 6 Read Yes Yes (Optimal and Degraded) Yes (Optimal and Degraded) Yes (Optimal and Degraded) Write Yes No No No In addition, FastPath-capable virtual disks are chara...

[Page 17] Dell H310

3. Boot the system and import the foreign configuration that is detected. You can do one of the following: – Press <F> to automatically import the foreign configuration. – Enter the BIOS Configuration Utility and navigate to the Foreign Con...

[Page 18] Dell H310

Virtual Disk Read Cache Policies The read policy of a virtual disk determines how the controller handles reads to that virtual disk. The read policies are: • Always Read Ahead—Allows the controller to read sequentially ahead of requested data and...

[Page 19] Dell H310

Source RAID Level Target RAID Level Number of Physical Disks (Beginning) Number of Physical Disks (End) Capacity Expansion Possible Description disk into a mirrored virtual disk by adding one disk. RAID 0 RAID 5 1 or more 3 or more Yes At l...

[Page 20] Dell H310

Source RAID Level Target RAID Level Number of Physical Disks (Beginning) Number of Physical Disks (End) Capacity Expansion Possible Description disk space used for distributed parity data. RAID 6 RAID 5 4 or more 4 or more Yes Removes one se...

[Page 21] Dell H310

of a virtual disk. The target disk needs to be a hot spare that qualifies as a rebuild disk. The physical disk with the SMART error is marked as failed only after the successful completion of the Replace Member. This avoids putting the array in deg...

[Page 22] Dell H310

Physical Disk Failure Detection Failed physical disks are detected and rebuilds automatically start to new disks that are inserted into the same slot. Automatic rebuilds can also happen transparently with hot spares. If you have configured hot spare...

[Page 23] Dell H310

Controller Cache Preservation The controller is capable of preserving its cache in the event of a system power outage or improper system shutdown. The PERC H710, H710P, and H810 controllers are attached to a Battery Backup Unit (BBU) that provides b...

[Page 24] Dell H310

24 ...

[Page 25] Dell H310

3 Deploying The PERC Card CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone se...

[Page 26] Dell H310

Figure 1. Removing and Installing the PERC Adapter 1. PCIe slot 2. SAS cable connectors (2) 3. PERC adapter 4. screw (1) Figure 2. Removing and Installing the PERC Mini Blade Controller 26 ...

[Page 27] Dell H310

1. release lever (2) 2. PERC stack-up connector 3. PERC mini blade controller 4. screws (2) Figure 3. Removing and Installing the PERC Mini Monolithic Controller 1. release lever (2) 2. storage-controller card holder 3. storage controller card 4. ba...

[Page 28] Dell H310

3. Install the storage controller in the appropriate controller slot and connect all the cables to the storage controller. CAUTION: When removing or replacing the PERC Mini Monolithic Controller, hold the card by its edges marked by the blue touch p...

[Page 29] Dell H310

CAUTION: If you remove any cables other than the ones added to enable redundant path support, the enclosure and disks can get disconnected, and virtual disk may fail. Perform the following steps to configure the hardware to utilize redundant paths o...

[Page 30] Dell H310

30 ...

[Page 31] Dell H310

4 Driver Installation The Dell PowerEdge RAID Controller (PERC) H310, H710, H710P, and H810 cards require software drivers to operate with the supported operating systems. This chapter contains the procedures for installing the drivers for the PERC ...

[Page 32] Dell H310

4. From the list of drivers displayed, select the driver you require. Select the self-extracting zip file and click Run. Copy the driver to a diskette drive, CD, DVD, or USB drive. Repeat this step for all the drivers you require. 5. During the oper...

[Page 33] Dell H310

9. Reboot the system when prompted. Updating Existing Windows Server 2008 Or Windows Server 2008 R2 NOTE: Close all applications on your system before you update the driver. 1. Insert the media (CD, DVD, or USB drive) containing the driver. 2. Select...

[Page 34] Dell H310

Installing Or Updating The RPM Driver Package With DKMS Support NOTE: This procedure is applicable for Red Hat Enterprise Linux 5 SP7 and SUSE Enterprise Linux 10 SP4. NOTE: For SUSE Enterprise Linux 10 SP4, immediately following the operating system...

[Page 35] Dell H310

You see a message similar to the following one: <driver name>, <driver version>, <new kernel version>: installed. 3. If the previous device driver is in use, you must reboot the system for the updated driver to take effect. 35 ...

[Page 36] Dell H310

36 ...

[Page 37] Dell H310

5 Management Applications For PERC Cards Dell OpenManage Storage Management applications enable you to manage and configure the RAID system, create and manage multiple disk groups, control and monitor multiple RAID systems, and provide online mainte...

[Page 38] Dell H310

A BIOS screen displays information about the controller and configuration. 2. During startup, press <Ctrl> <R> when prompted by the BIOS screen. 3. Use the arrow keys to select the RAID controller you want to configure, and press <Ente...

[Page 39] Dell H310

Notation Meaning and Use Example down- arrow key Use the down-arrow key to move to the lower menu items within a menu or to a lower level menu. You can also use the down-arrow key to open a menu list in a popup window, such as the stripe element ...

[Page 40] Dell H310

For more information, see the topic Managing Dedicated Hot Spares. 3. Initialize the virtual disks. NOTE: When you use one physical disk group to create multiple virtual disks, all the virtual disks must be configured with the same RAID level. When ...

[Page 41] Dell H310

Parameter Description No-Read-Ahead specifies that the controller does not use read ahead for the current virtual disk. Adaptive specifies that the controller begins using Read-Ahead if the two most recent disk accesses occurred in sequential secto...

[Page 42] Dell H310

15. Press the spacebar to make the settings active so that you can change them. An X is displayed beside Advanced Settings. The settings are the stripe element size, read policy, and write policy. You can also choose advanced options such as forcing...

[Page 43] Dell H310

5. Press <Enter>. Converting Physical Disk To Non-RAID For PERC H310 Conversion of a Physical Disk to Non-RAID allows direct operating system access to the drive. Non-RAID disks cannot be used within a Virtual Disk nor can they be used as Hot ...

[Page 44] Dell H310

The Consistency Check runs and checks the redundancy data in the virtual disks. 7. After you start the Consistency Check, press <Esc> to display the previous menu if needed. Importing Or Clearing Foreign Configurations Using The VD Mgmt Menu Wh...

[Page 45] Dell H310

• The physical disks in a non-redundant virtual disk are removed. The following constraints apply to the physical disks that are considered for import: • The disk state of a physical disk can change from the time the foreign configuration is scan...

[Page 46] Dell H310

Break Mirror A Break Mirror operation is an operation that can be performed only on RAID1 arrays. It provides a way to 'split' the mirror and spin-down one of the hard disks, which can then be imported into the configuration of a different...

[Page 47] Dell H310

Perform the following steps to select whether to import the virtual disk or discard the preserved cache: 1. On the VD Mgmt screen, click on a controller icon. 2. Press <F2> to display the available actions. 3. Select Manage Preserved Cache. A m...

[Page 48] Dell H310

Deleting Virtual Disks NOTE: You cannot delete a virtual disk during an initialization. NOTE: Warning messages appear stating the effect of deleting a virtual disk. Click OK twice to complete the virtual disk deletion. To delete virtual disks, perfo...

[Page 49] Dell H310

BIOS Configuration Utility Menu Options The first menu that is displayed when you access the BIOS Configuration Utility <Ctrl> <R> is the main menu screen. It lists the controller, controller number, and other information, such as the sl...

[Page 50] Dell H310

Menu Item Selected in Left Panel Information Displayed in Right Panel • Security property of the Disk Group Virtual Disks Disk Group # Properties: • Number of virtual disks (VD) • Number of physical disks (PD) • Space available in the virtual...

[Page 51] Dell H310

Menu Item Selected in Left Panel Information Displayed in Right Panel • Number of physical disks (PD) • Space available on the physical disks • Number of free segments • Number of dedicated hot spares Hot Spares Physical Disk Properties: • ...

[Page 52] Dell H310

Physical Disk Management (PD Mgmt) The Physical Disk Management screen (PD Mgmt) displays physical disk information and action menus. The screen displays physical disk IDs, vendor names, disk size, type, state, and disk group (DG). You can sort the ...

[Page 53] Dell H310

Action Description Remove HS Removes a dedicated hot spare from its disk group or a global hot spare from the global pool of hot spares. Rebuild Select Rebuild to rebuild one or more failed physical disks. For information on performing a physical di...

[Page 54] Dell H310

Option Description controller and disable it on the other controllers. The system can then boot from the BIOS-enabled controller. Enable BIOS Stop On Error Select the option to stop the system BIOS during bootup if there are BIOS errors. The option...

[Page 55] Dell H310

Creating Global Hot Spares You can use a global hot spare to replace a failed physical disk in any redundant array as long as the capacity of the global hot spare is equal to or larger than the coerced capacity of the failed physical disk. Perform t...

[Page 56] Dell H310

NOTE: The replacement disk must be a hot spare or an unconfigured disk without a foreign configuration. It must have the same or greater capacity and should be of the same type as the disk it is replacing. Restrictions and Limitations The following ...

[Page 57] Dell H310

Controller Management Enabling Boot Support NOTE: See your system documentation to ensure the proper boot order is selected in the system BIOS. In a multiple controller environment, you can enable BIOS on multiple controllers. However, if you want to...

[Page 58] Dell H310

NOTE: The controller automatically imports every optimal and degraded foreign configuration without enabling the feature if there is no native configuration on the controller. To enable Auto Import: 1. Press <Ctrl> <N> to access the Ctrl...

[Page 59] Dell H310

3. From System Setup Main Menu, enter Device Settings. Device Settings lists all the RAID controllers in the system. Use the arrow keys or mouse to select the RAID controller you want to configure/mange and press <Enter> or click on the mouse ...

[Page 60] Dell H310

* Safe mode on errors: The system will continue booting as long as the boot volume is not on this controller. Drives connected to the controller will be reported as unconfigured good drives to the RAID management utilities upon a successful boot. N...

[Page 61] Dell H310

6 CacheCade The Dell PowerEdge RAID Controller (PERC) H710, H710P, and H810 cards support CacheCade, a feature that can improve application performance by increasing read caching capacity. The CacheCade feature makes use of high performing solid st...

[Page 62] Dell H310

CacheCade Virtual Disk Management The Virtual Disk Management screen is the first screen that is displayed when you access a RAID controller from the main menu screen on the BIOS Configuration Utility. The following are CacheCade-related actions you...

[Page 63] Dell H310

Deleting CacheCade Virtual Disks To delete CacheCade virtual disks, perform the following steps in the BIOS Configuration Utility: 1. Press <Ctrl> <N> to access the Virtual Disk Management screen. 2. Use the arrow keys to move the cursor ...

[Page 64] Dell H310

• Any number of SSDs can be added to a CacheCade virtual disk. • There is no SAS and SATA mixing allowed within a CacheCade virtual disk, so SATA SSDs cannot be added to a SAS CacheCade virtual disk and vice versa. • HDDs cannot be added to a ...

[Page 65] Dell H310

7 Security Key And RAID Management NOTE: PERC H310 does not support any security implementations. Security Key Implementation The Dell PowerEdge RAID Controller (PERC) H710, H710P, and H810 cards support Self-Encrypting Disks (SED) for protection of...

[Page 66] Dell H310

Creating A Security Key Perform the following steps to create a security key on the controller: NOTE: There is no passphrase backup option when you create a security key; you need to remember your passphrase. 1. During the host system boot up, press...

[Page 67] Dell H310

NOTE: If there is an existing configuration on the controller, it is updated with the new security key. If you had previously removed any secured disks, you still need to supply the old passphrase to import them. Deleting A Security Key NOTE: Delete...

[Page 68] Dell H310

5. Highlight the Secure Disk Group option and press <Enter>. NOTE: If you select to secure a Disk Group, all VDs part of the Disk Group are secured. Securing Pre-Existing Virtual Disks If an unsecured virtual disk was created on a controller, y...

[Page 69] Dell H310

3. Press <F2> to display a menu of available actions. 4. Select Import to import the foreign configuration or Clear to delete the foreign configuration. Press <Enter>. NOTE: To Clear, you need to Instant Secure Erase foreign configuration...

[Page 70] Dell H310

there is a security key present. Select the Secure VD option as No in the Create New VD menu. See the topic Creating Virtual Disks for steps on how to create an unsecured virtual disk. Failure To Delete Security Key A security key is used to lock or...

[Page 71] Dell H310

8 Troubleshooting To get help with your Dell PowerEdge RAID Controller (PERC) H310, H710, H710P and H810, you can contact your Dell Technical Service representative or see dell.com/support. BIOS Error Messages The controller BIOS read-only memory (R...

[Page 72] Dell H310

• The controller detects an Error-Correcting Code (ECC) error while performing its cache checking routine during initialization. • The controller discards the cache rather than sending it to the disk subsystem because the data integrity cannot ...

[Page 73] Dell H310

Corrective Action: Check the cable connections and fix any issues. Restart the system. If there are no cable problems, press any key or <C> to continue. Dirty Cache Data Error Message Error Message: The following virtual disks are missing: (x...

[Page 74] Dell H310

Corrective Action: Check the cable connections and fix any problems before restarting the system. If there are no cable problems, press any key or <Y> to continue. Adapter At Baseport Not Responding Error Message Error Message: Adapter at Bas...

[Page 75] Dell H310

Virtual Disks Partially Degraded Error Message Error Message: x Virtual Disk(s) Partially Degraded, where x is the number of virtual disks partially degraded. Probable Cause: This message is displayed when the BIOS detects a single disk failure in a...

[Page 76] Dell H310

Foreign Configuration Not Found In <Ctrl> <R> Error Message Error Message: The foreign configuration message is present during POST but no foreign configurations are present in the foreign view page in <Ctrl> <R>. All virtua...

[Page 77] Dell H310

CAUTION: When removing or replacing the PERC Mini Monolithic Controller, hold the card by its edges marked by the blue touch points. Do not handle the card while holding the battery or the heatsink. For more information, see figure “Removing and ...

[Page 78] Dell H310

To recover a virtual disk from a degraded state, you must replace the failed physical disk and rebuild it. Once the rebuilding process is complete, the virtual disk state changes from degraded to optimal. For information on rebuilding the disk, see...

[Page 79] Dell H310

Corrective Action: The issue occurs because of any of the following causes: • The driver is not native in the operating system. To resolve the issue, press <F6> to install the RAID device driver during installation. • The virtual disks...

[Page 80] Dell H310

Multiple Disks Become Inaccessible Issue: Rebuilding the physical disks after multiple disks become simultaneously inaccessible. Corrective Action: Multiple physical disk errors in a single array typically indicate a failure in cabling or connectio...

[Page 81] Dell H310

Physical Disk Fails During Reconstruction On Redundant Virtual Disk Issue: A physical disk fails during a reconstruction process on a redundant virtual disk that has a hot spare. Corrective Action: The dedicated hot spare goes to Ready state and th...

[Page 82] Dell H310

Smart Error Detected On A Physical Disk In A Non-Redundant Virtual Disk Issue: A SMART error is detected on a physical disk in a redundant virtual disk. Corrective Action: Perform the following steps: 1. Back up your data. 2. Use Replace Member or s...

[Page 83] Dell H310

Corrective Action: The error message is displayed when the Linux Small Computer System Interface (SCSI) mid- layer asks for physical disk cache settings. The controller firmware manages the virtual disk cache settings on a per controller and a per ...

[Page 84] Dell H310

Disk Carrier LED Indicators The LED on the physical disk carrier indicates the state of each physical disk. Each disk carrier in your enclosure has two LEDs: an activity LED (green) and a status LED (bicolor, green/amber). The activity LED is active...

[Page 85] Dell H310

9 Appendix: RAID Description RAID is a group of independent physical disks that provides high performance by increasing the number of disks used for saving and accessing data. CAUTION: In the event of a physical disk failure, a RAID 0 virtual disk f...

[Page 86] Dell H310

For example, in a four-disk system using only disk striping (used in RAID 0), segment 1 is written to disk 1, segment 2 is written to disk 2, and so on. Disk striping enhances performance because multiple physical disks are accessed simultaneously,...

[Page 87] Dell H310

RAID 6 combines dual distributed parity with disk striping. This level of parity allows for two disk failures without duplicating the contents of entire physical disks. Figure 8. Example of Distributed Parity (RAID 5) NOTE: Parity is distributed acr...