Summary of Contents:

[Page 1] Dell PowerEdge C2100

Dell™ PowerEdge™ C2100 Systems Hardware Owner’s Manual Regulatory Model FS12-TY book.book Page 1 Friday, November 8, 2013 11:29 AM ...

[Page 2] Dell PowerEdge C2100

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: ...

[Page 3] Dell PowerEdge C2100

book.book Page 3 Friday, November 8, 2013 11:29 AM ...

[Page 4] Dell PowerEdge C2100

book.book Page 4 Friday, November 8, 2013 11:29 AM ...

[Page 5] Dell PowerEdge C2100

Contents 3 Contents 1 About Your System. . . . . . . . . . . . . . . . . . . 9 Accessing System Features During Startup. . . . . . . . 9 Front-Panel Features and Indicators . . . . . . . . . . 10 Hard-Drive Indicator Patterns . . . . . . . . . ....

[Page 6] Dell PowerEdge C2100

4 Contents Main Screen . . . . . . . . . . . . . . . . . . . . 39 AMIBIOS Settings. . . . . . . . . . . . . . . . . . 40 Processor Settings . . . . . . . . . . . . . . . . . 40 System Memory Settings . . . . . . . . . . . . . . 40 Advanced ...

[Page 7] Dell PowerEdge C2100

Contents 5 Installing a Hard-Drive Carrier . . . . . . . . . . . 55 Removing a Hard Drive From a Hard-Drive Carrier . . . . . . . . . . . . . . . . . 56 Installing a Hard Drive Into a Hard-Drive Carrier . . . . . . . . . . . . . . . . . 56 ...

[Page 8] Dell PowerEdge C2100

6 Contents Expansion-Card Riser and Expansion Card . . . . . . . 75 Removing the Expansion-Card Riser . . . . . . . . 75 Installing the Expansion-Card Riser . . . . . . . . 77 Removing the Expansion Card . . . . . . . . . . . 78 Installing ...

[Page 9] Dell PowerEdge C2100

Contents 7 Cooling Fans . . . . . . . . . . . . . . . . . . . . . . . 95 Removing a Cooling Fan Assembly . . . . . . . . . 95 Installing the Cooling Fan Assembly . . . . . . . . 96 Removing the Fan Module . . . . . . . . . . . . . 97 Install...

[Page 10] Dell PowerEdge C2100

8 Contents Troubleshooting a NIC . . . . . . . . . . . . . . . . . 112 Troubleshooting a Wet System . . . . . . . . . . . . . 113 Troubleshooting a Damaged System . . . . . . . . . . 114 Troubleshooting the System Battery . . . . . . . . . . ...

[Page 11] Dell PowerEdge C2100

Contents 9 6 Getting Help. . . . . . . . . . . . . . . . . . . . . . 133 Contacting Dell . . . . . . . . . . . . . . . . . . . . . 133 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 book.book Page 9 Friday, November 8, 20...

[Page 12] Dell PowerEdge C2100

10 Contents book.book Page 10 Friday, November 8, 2013 11:29 AM ...

[Page 13] Dell PowerEdge C2100

About Your System 9 1 About Your System Accessing System Features During Startup The following keystrokes provide access to system features during startup. Keystroke Description <F2> Enters the System Setup program. See "Start Menu" o...

[Page 14] Dell PowerEdge C2100

10 About Your System Front-Panel Features and Indicators Figure 1-1. Front-Panel Features and Indicators Item Indicator, Button, or Connector Icon Description 1 Fault LED Displays status errors and is controlled by the Baseboard Management Control...

[Page 15] Dell PowerEdge C2100

About Your System 11 6 LCD panel Provides system ID, status information, and system error messages. The LCD lights blue during normal system operation. The LCD lights amber when the system needs attention, and the LCD panel displays an error cod...

[Page 16] Dell PowerEdge C2100

12 About Your System Hard-Drive Indicator Patterns Figure 1-2. Hard-Drive Indicators 10 Power-on indicator The power-on indicator lights when the system power is on. NOTE: When powering on the system, the video monitor can take from several second...

[Page 17] Dell PowerEdge C2100

About Your System 13 Table 1-1. Hard Drive Indicators—On-Board SATA Ports Drive-Status Indicator/Drive-Activity Indicator Condition Off/Off No drive Steady green/Off Drive online (no access) Steady green/Off Drive is present or in idle stage Stead...

[Page 18] Dell PowerEdge C2100

14 About Your System Back-Panel Features and Indicators Figure 1-3. Back-Panel Features and Indicators Item Indicator, Button, or Connector Icon Description 1 Slot cover for power supply 2 Your system comes with one single power supply or a set of...

[Page 19] Dell PowerEdge C2100

About Your System 15 NIC Indicator Codes Figure 1-4. NIC Indicators 6 USB connectors (2) Connect USB devices to the system. The ports are USB 2.0-compliant. 7 Video connector Connects a VGA display to the system. 8 Serial connector Connects a serial...

[Page 20] Dell PowerEdge C2100

16 About Your System Table 1-3. NIC Speed Indicator Codes Table 1-4. NIC Indicator Codes—iBMC Table 1-5. NIC Speed Indicator Codes (KVM Over IP Port) NIC Speed Indicator Condition Steady amber Link at 1 Gbps Blinks amber Identifying port with 1 ...

[Page 21] Dell PowerEdge C2100

About Your System 17 Power and System Board Status Codes The LEDs on the system front and back panel display status codes during system startup. All systems share the same LEDs on the front and back panel. Table 1-6 lists the status associated with...

[Page 22] Dell PowerEdge C2100

18 About Your System Table 1-9. Fault Indicator Codes Collecting System Event Log for Investigation If the front panel LED blinks for 30 to 60 seconds upon applying AC power to the power supply, the baseboard management controller (iBMC) is initial...

[Page 23] Dell PowerEdge C2100

About Your System 19 0004 Yes CMOS Settings Wrong Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 133. 0005 Yes CMOS Checksum Bad Remove AC power to the system fo...

[Page 24] Dell PowerEdge C2100

20 About Your System 0017 Yes WARN SETUP INVALID Error See "Getting Help" on page 133. 0018 Yes WARN DIMM COMPAT MINOR X16 C0MBO Error See "Getting Help" on page 133. 0019 Yes WARN DIMM COMPAT MINOR MAX RANKS Error See &...

[Page 25] Dell PowerEdge C2100

About Your System 21 0020 Yes WARN MEMTEST DIMM DISABLE Error See "Getting Help" on page 133. 0021 Yes WARN MIRROR DISABLE MINOR RAS DISABLED Error See "Getting Help" on page 133. 0022 Yes WARN MIRROR DISABLE MINOR MISMAT...

[Page 26] Dell PowerEdge C2100

22 About Your System 002B Yes WARN WR DQ DQS Error See "Getting Help" on page 133. 002C Yes WARN DIMM POP RUL MINOR OUT OF ORDER Error See "Getting Help" on page 133. 002D Yes WARN DIMM POP RUL MINOR INDEPENDENT MODE Erro...

[Page 27] Dell PowerEdge C2100

About Your System 23 0035 Yes WARN DIMM VREF NOT PRESENT Error See "Getting Help" on page 133. 0036 Yes WARN DDR3L MIXED Error See "Getting Help" on page 133. 0037 Yes WARN DDR3L 3DPC Error See "Getting Help" on p...

[Page 28] Dell PowerEdge C2100

24 About Your System 0045 Yes DMA-1 Error See "Troubleshooting System Memory" on page 117. If the problem persists, see "Getting Help" on page 133. 0046 Yes DMA-2 Error See "Troubleshooting System Memory" on page 117....

[Page 29] Dell PowerEdge C2100

About Your System 25 005D Yes S.M.A.R.T. Command Failed S.M.A.R.T. Status BAD, Backup and Replace See "Getting Help" on page 133. 0060 Yes Primary Master Hard Disk Error See "Troubleshooting a Hard Drive" on page 119. 006...

[Page 30] Dell PowerEdge C2100

26 About Your System 0083 Yes Secondary Slave Drive - ATAPI Incompatible See "Troubleshooting a Hard Drive" on page 119. 0101 Yes Warning! This system board does not support the power requirements of the installed processor. Th...

[Page 31] Dell PowerEdge C2100

About Your System 27 0121 Yes Thermal Failure detected by PROCHOT# Ensure that the processor heat sinks are properly installed. See "Troubleshooting Processors" on page 122 and "Troubleshooting System Cooling Problems" on p...

[Page 32] Dell PowerEdge C2100

28 About Your System 0150 Yes Processor failed BIST Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 133. 0151 Yes Processor failed BIST Remove AC power to the syst...

[Page 33] Dell PowerEdge C2100

About Your System 29 0160 Yes Processor missing microcode A BIOS update is required. If the problem persists, see "Getting Help" on page 133. 0161 Yes Processor missing microcode A BIOS update is required. If the problem persists, se...

[Page 34] Dell PowerEdge C2100

30 About Your System 0181 Yes BIOS does not support current stepping Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system’s Getting Started Guide. 0182 Yes BIOS...

[Page 35] Dell PowerEdge C2100

About Your System 31 0194 Yes CPUID, Processor family are different Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system’s Getting Started Guide. 0196 Yes CPUID...

[Page 36] Dell PowerEdge C2100

32 About Your System 0403 Yes AHCI Port3 HDD Error See "Troubleshooting a Hard Drive" on page 119. 0404 Yes AHCI Port4 HDD Error See "Troubleshooting a Hard Drive" on page 119. 0405 Yes AHCI Port5 HDD Error See "Troubles...

[Page 37] Dell PowerEdge C2100

About Your System 33 8104 Yes Warning! Port 60h/64h emulation is not supported by this USB Host Controller!!! See "Troubleshooting a USB Device" on page 110. If the problem persists, see "Getting Help" on page 133. 8105 Ye...

[Page 38] Dell PowerEdge C2100

34 About Your System 8701 Yes Insufficient Runtime space for MPS data. System may operate in PCI or Non- MPS mode. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on p...

[Page 39] Dell PowerEdge C2100

About Your System 35 Beep Codes The following table describes the system pre post beep codes. Table 1-10. Pre Post Beep Codes Post Beep Codes Table 1-11. Post Beep Codes Number of Beeps Description 1No media 2 Boot-block BIOS file absent 3 Insert ne...

[Page 40] Dell PowerEdge C2100

36 About Your System Other Information You May Need WARNING: See the safety and regulatory information that shipped with your system. Warranty information may be included within this document or as a separate document. •The Getting Started Gui...

[Page 41] Dell PowerEdge C2100

Using the System Setup Program 37 2 Using the System Setup Program Start Menu The system employs the latest AMI Core BIOS, which is stored in Flash memory. The Flash memory supports the Plug and Play specification, and contains a System Setup progr...

[Page 42] Dell PowerEdge C2100

38 Using the System Setup Program System Setup Options at Boot You can initiate Setup by pressing <F2> during POST. Console Redirection The console redirection allows a remote user to diagnose and fix problems on a system, which has not succes...

[Page 43] Dell PowerEdge C2100

Using the System Setup Program 39 Main Menu The main menu displays information about your system board and BIOS. Main Screen Figure 2-1. System Setup Program Main Screen NOTE: The options for the System Setup program change based on the system con...

[Page 44] Dell PowerEdge C2100

40 Using the System Setup Program AMIBIOS Settings Processor Settings System Memory Settings Advanced Menu This option displays a table of items that define advanced information about your system. WARNING: Making incorrect settings to items on the...

[Page 45] Dell PowerEdge C2100

Using the System Setup Program 41 Processor Configuration Option Description Hardware Prefetcher (Enabled default) Enable this option to control the Hardware Prefetcher feature. Adjacent Cache Line Prefetch (Enabled default) Enable this option to...

[Page 46] Dell PowerEdge C2100

42 Using the System Setup Program Memory Configuration IDE Configuration NUMA Support (Disabled default) When Enabled, executes software for NUMA aware OS. When Disabled, allows better memory access performance for non-NUMA OS. Option Description ...

[Page 47] Dell PowerEdge C2100

Using the System Setup Program 43 Super IO Configuration USB Configuration PCI Configuration Option Description Serial Port1 Address (3F8/IRQ4 default) Assigns the I/O address and IRQ for the first onboard serial port. Serial Port2 Address (3F8/IR...

[Page 48] Dell PowerEdge C2100

44 Using the System Setup Program PCI-E SLOT Option Rom (Enabled default) Enables or disables add-on card option ROM. PCI-E Connector Option Rom (Enabled default) Enables or disables board to board PCI-E connector option ROM. NIC1 Mac Address Disp...

[Page 49] Dell PowerEdge C2100

Using the System Setup Program 45 Boot Menu Boot Settings Configuration Option Description Boot Settings Configuration Configures the settings during system boots. Boot Device Priority Specifies the boot device priority. Hard Disk Drives Specifies t...

[Page 50] Dell PowerEdge C2100

46 Using the System Setup Program Force PXE First (Enabled default) Enables forced network boot (PXE). Force PXE Boot Only Enable or disable PXE to be the only boot device. Force USB First Enable force USB to be the first boot device. Option Descrip...

[Page 51] Dell PowerEdge C2100

Using the System Setup Program 47 Server Menu NOTE: Delay Time, Minimum time, and Maximum time are only shown in SETUP screen when AC Power Recovery Delay is set to User define. The selection of Restore on AC Power Loss setup to Power-on or Last ...

[Page 52] Dell PowerEdge C2100

48 Using the System Setup Program iBMC LAN Configuration QPI Error Logging (Enabled default) Enables or disables IOH QPI 0/1 error. IOH Internal Error Logging (Enabled default) Enables or disables IOH Internal error logging. NMI on Error (Fatal d...

[Page 53] Dell PowerEdge C2100

Using the System Setup Program 49 Remote Access Configuration NOTE: When Flow Control is set to Software, the Hyper Terminal on remote side is discontinued by pressing <Ctrl><S>. But the <Ctrl><S> is also the Setup Key Stro...

[Page 54] Dell PowerEdge C2100

50 Using the System Setup Program Security Menu Exit Menu Option Description Supervisor Password Displays whether the supervisor password is installed or not. User Password Displays whether the user password is installed or not. Change Supervisor Pa...

[Page 55] Dell PowerEdge C2100

Installing System Components 51 3 Installing System Components Safety Instructions WARNING: Working on systems that are still connected to a power supply can be extremely dangerous. CAUTION: System components and electronic circuit boards can be...

[Page 56] Dell PowerEdge C2100

52 Installing System Components Inside the System CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by ...

[Page 57] Dell PowerEdge C2100

Installing System Components 53 Hard Drives CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the ...

[Page 58] Dell PowerEdge C2100

54 Installing System Components Removing a Hard-Drive Blank CAUTION: To maintain proper system cooling, all empty hard-drive bays must have drive blanks installed. Press the release button and slide the hard-drive blank out of the hard-drive bay...

[Page 59] Dell PowerEdge C2100

Installing System Components 55 2 Press the release button on the front of the hard-drive carrier to open the release lever. 3 Using the release lever, slide the hard-drive carrier out of the hard-drive bay. See Figure 3-3. 4 If you are not install...

[Page 60] Dell PowerEdge C2100

56 Installing System Components Removing a Hard Drive From a Hard-Drive Carrier 1 Turn over the hard drive and remove the four screws on the hard-drive carrier. See Figure 3-4. 2 Lift the hard drive out of the hard-drive carrier. Figure 3-4. Removin...

[Page 61] Dell PowerEdge C2100

Installing System Components 57 Removing the Optional Internal Hard Drive 1 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet. 2 Open the system. See "Opening the System" on page...

[Page 62] Dell PowerEdge C2100

58 Installing System Components Installing the Optional Internal Hard Drive 1 Place the hard drives in position on the hard drive assembly. 2 Affix the eight screws securing the hard drives to the hard-drive assembly. See Figure 3-5. 3 Replace the c...

[Page 63] Dell PowerEdge C2100

Installing System Components 59 Figure 3-6. Opening and Closing the System Closing the System 1 Place the cover on the chassis and offset it slightly toward the back of the system, so that the hooks on the sides of the cover fit over the correspond...

[Page 64] Dell PowerEdge C2100

60 Installing System Components Cooling Shroud CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the...

[Page 65] Dell PowerEdge C2100

Installing System Components 61 Figure 3-7. Removing and Installing the Cooling Shroud Installing the Cooling Shroud 1 Align the cooling shroud around the sides of the heat sink and along the memory slots and lower it into the system. See Figure 3-7...

[Page 66] Dell PowerEdge C2100

62 Installing System Components Heat Sinks CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the onl...

[Page 67] Dell PowerEdge C2100

Installing System Components 63 Figure 3-8. Removing and Installing the Heat Sink 1 expansion-card riser assembly 2 heat sinks (2) 3 captive screws (4 each) 2 3 1 book.book Page 63 Friday, November 8, 2013 11:29 AM ...

[Page 68] Dell PowerEdge C2100

64 Installing System Components Installing the Heat Sink CAUTION: The heat sinks for CPU0 and CPU1 are different and are labeled accordingly. They must be installed in the correct location and orientation to prevent the system from overheating. 1...

[Page 69] Dell PowerEdge C2100

Installing System Components 65 4 Remove the heat sink. See "Removing the Heat Sink" on page 62. CAUTION: The processor is held in its socket under strong pressure. Be aware that the release lever can spring up suddenly if not firmly gra...

[Page 70] Dell PowerEdge C2100

66 Installing System Components Installing the Processor NOTE: When installing only one processor, the processor must be installed in CPU0 socket (for the socket location, see Figure 5-3). NOTE: Your system uses an LGA 1366 socket, which is desi...

[Page 71] Dell PowerEdge C2100

Installing System Components 67 7 Align the notches in the processor with the socket keys on the ZIF socket. See Figure 3-9. 8 With the release lever on the processor socket in the open position, align the processor with the socket keys and set the...

[Page 72] Dell PowerEdge C2100

68 Installing System Components • Single-rank, and dual-rank RDIMMs of sizes 1 GB, 2 GB, 4 GB, 8 GB and 16 GB are supported for a total of up to 288 GB. • Quad-rank RDIMMs (two per channel) are supported for a total of up to 48 GB. General Memo...

[Page 73] Dell PowerEdge C2100

Installing System Components 69 • Two memory modules per channel are limited to 800 MHz, regardless of the memory module speed. • If quad-rank memory modules are mixed with single- or dual-rank modules, the quad-rank modules must be installed i...

[Page 74] Dell PowerEdge C2100

70 Installing System Components Memory Socket Location on the System Board The system contains 18 memory sockets split into two sets of 9 sockets, one set per processor. Figure 3-10. Memory Socket Location on the System Board book.book Page 70 Fri...

[Page 75] Dell PowerEdge C2100

Installing System Components 71 Supported Memory Configuration There are eighteen DIMMs on each system board to support processor 0 and processor 1. The DIMM sequence of eighteen DIMM sockets is shown below. When you insert the DIMM(s), you have to...

[Page 76] Dell PowerEdge C2100

72 Installing System Components Removing Memory Modules WARNING: The memory modules are hot to touch for some time after the system has been powered down. Allow time for the memory modules to cool before handling them. Handle the memory modules b...

[Page 77] Dell PowerEdge C2100

Installing System Components 73 Figure 3-11. Removing and Installing a Memory Module Installing Memory Modules CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as ...

[Page 78] Dell PowerEdge C2100

74 Installing System Components NOTE: The memory module socket has an alignment key that allows you to install the memory module in the socket in only one way. 4 Press down on the memory module with your thumbs until the ejectors lock into positi...

[Page 79] Dell PowerEdge C2100

Installing System Components 75 Expansion-Card Riser and Expansion Card CAUTION: Expansion cards can only be installed in the slots on the expansion-card riser. Do not attempt to install expansion cards directly into the riser connector on the s...

[Page 80] Dell PowerEdge C2100

76 Installing System Components Figure 3-12. Removing and Installing the Expansion-Card Riser Assembly 1 expansion-card riser assembly 2 expansion-card riser assembly connector 1 2 book.book Page 76 Friday, November 8, 2013 11:29 AM ...

[Page 81] Dell PowerEdge C2100

Installing System Components 77 Figure 3-13. Removing and Installing the Expansion-Card Riser Installing the Expansion-Card Riser CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting an...

[Page 82] Dell PowerEdge C2100

78 Installing System Components 5 Replace the system cover. See "Closing the System" on page 59. 6 Reconnect the system and peripherals to their electrical outlets, and turn on the system. Removing the Expansion Card CAUTION: Many repai...

[Page 83] Dell PowerEdge C2100

Installing System Components 79 NOTE: Keep this bracket in case you need to remove the expansion card. Filler brackets must be installed over empty expansion-card slots to maintain FCC certification of the system. The brackets also keep dust and ...

[Page 84] Dell PowerEdge C2100

80 Installing System Components Installing the Expansion Card CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as ...

[Page 85] Dell PowerEdge C2100

Installing System Components 81 Integrated Storage Controller Cards Your system includes a dedicated expansion-card slot on the system board for an integrated SAS controller card that provides the integrated storage subsystem for your system’s ha...

[Page 86] Dell PowerEdge C2100

82 Installing System Components Figure 3-15. Removing and Installing the Integrated Storage Controller Card Installing the Integrated Storage Controller Card CAUTION: Many repairs may only be done by a certified service technician. You should only...

[Page 87] Dell PowerEdge C2100

Installing System Components 83 4 Install the integrated storage controller card in place. See Figure 3-15. 5 Connect the SAS data cable to the integrated storage controller card. 6 Close the system. See "Closing the System" on page 59. 7 ...

[Page 88] Dell PowerEdge C2100

84 Installing System Components Figure 3-16. Removing and Installing a RAID Battery Installing a RAID Battery CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as a...

[Page 89] Dell PowerEdge C2100

Installing System Components 85 4 Secure the RAID battery carrier onto the chassis using the two screws. See Figure 3-16. 5 Connect the RAID battery cable to the RAID battery connector on the storage controller card. See Figure 3-15. 6 Close the s...

[Page 90] Dell PowerEdge C2100

86 Installing System Components Figure 3-17. Removing and Installing the Dual RAID Battery Cage 1 RAID battery carrier 2 screws (2) 3 RAID batteries (2) 2 1 3 book.book Page 86 Friday, November 8, 2013 11:29 AM ...

[Page 91] Dell PowerEdge C2100

Installing System Components 87 Figure 3-18. Removing and Installing a Dual RAID Battery From the Battery Carrier Installing a RAID Battery CAUTION: Many repairs may only be done by a certified service technician. You should only perform troublesh...

[Page 92] Dell PowerEdge C2100

88 Installing System Components 4 Connect the RAID battery cable to the RAID battery connector on the storage controller card. See Figure 3-15. 5 Close the system. See "Closing the System" on page 59. 6 Reconnect your system and peripheral...

[Page 93] Dell PowerEdge C2100

Installing System Components 89 Figure 3-19. Removing and Installing the Mezzanine Card (10 GbE LAN) 1 mezzanine card (10 GbE LAN) 2 mezzanine-card cover 3 screws (3) 4 back panel 5 spacer pins (3) 1 2 3 4 5 book.book Page 89 Friday, November 8,...

[Page 94] Dell PowerEdge C2100

90 Installing System Components Installing the Mezzanine Card (10 GbE LAN) CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product document...

[Page 95] Dell PowerEdge C2100

Installing System Components 91 Power Supplies WARNING: Whenever you need to lift the system, get others to assist you. To avoid injury, do not attempt to lift the system by yourself. CAUTION: Many repairs may only be done by a certified service...

[Page 96] Dell PowerEdge C2100

92 Installing System Components Figure 3-20. Removing and Installing the Power Supply Installing the Power Supply 1 Verify that both power supplies are of the same type and have the same maximum output power. 2 Slide the new power supply into the sy...

[Page 97] Dell PowerEdge C2100

Installing System Components 93 Removing the Power Supply Blank CAUTION: To ensure proper system cooling, the power supply blank must be installed in power supply bay PS2 in a non-redundant configuration. Remove the power supply blank only if you...

[Page 98] Dell PowerEdge C2100

94 Installing System Components Figure 3-21. Removing and Installing the Power Distribution Board Assembly Installing the Power Distribution Board Assembly CAUTION: Many repairs may only be done by a certified service technician. You should only p...

[Page 99] Dell PowerEdge C2100

Installing System Components 95 2 Replace the two screws that secure the power distribution board assembly to the bottom of the chassis. 3 Connect all the power cables. See Figure 3-21. 4 Replace the system cover. See "Closing the System"...

[Page 100] Dell PowerEdge C2100

96 Installing System Components Figure 3-22. Removing and Installing the Fan Assembly Installing the Cooling Fan Assembly 1 Place the fan assembly into the system and slide the fan assembly slightly toward the back of the system. 2 Align the slot o...