[Page 1] Dell PowerEdge C6145

Regulatory Model B05S Dell PowerEdge C6145 Systems Hardware Owner’s Manual ...

[Page 2] Dell PowerEdge C6145

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better user of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed....

[Page 3] Dell PowerEdge C6145

Contents | 3 Contents 1 About Your System ...................................................................... 11 Accessing System Features During Startup ................................................. 11 Front-Panel Features and ...

[Page 4] Dell PowerEdge C6145

4 | Contents Product Information.................................................................................. 50 Processor ................................................................................................... 51 System Me...

[Page 5] Dell PowerEdge C6145

Contents | 5 IPMI Configuration ................................................................................... 87 Exit Menu............................................................................................................ 91 C...

[Page 6] Dell PowerEdge C6145

6 | Contents Installing the Heat Sink .......................................................................... 119 Processors........................................................................................................ 121 Remo...

[Page 7] Dell PowerEdge C6145

Contents | 7 Removing the Expansion-Card Connector........................................... 149 Installing the Expansion-Card Connector ............................................ 150 Mezzanine Card ..........................................

[Page 8] Dell PowerEdge C6145

8 | Contents Removing a Cooling Fan ......................................................................... 175 Installing a Cooling Fan .......................................................................... 176 Middle Planes ...........

[Page 9] Dell PowerEdge C6145

Contents | 9 Installing the Sensor Board for 2.5” Hard Drive System ................... 210 4 Troubleshooting Your System ................................................. 212 Safety First – For You and Your System ........................

[Page 10] Dell PowerEdge C6145

10 | Contents 3.5" Hard-Drive Backplane With CPLD ................................................. 231 3.5" Hard-Drive Backplane With Expander .......................................... 232 2.5" Hard-Drive Backplane With Exp...

[Page 11] Dell PowerEdge C6145

1 About Your System | 11 About Your System Accessing System Features During Startup The following keystrokes provide access to system features during startup. Keystroke Description <F2> Enters the System Setup program. See “Start ...

[Page 12] Dell PowerEdge C6145

12 | About Your System Front-Panel Features and Indicators Figure 1-1. Front Panel − 3.5” x8 Hard Drives With Two Motherboards Figure 1-2. Front Panel−3.5” x12 Hard Drives With Two Motherboards Figure 1...

[Page 13] Dell PowerEdge C6145

About Your System | 13 Figure 1-5. Front Panel−2.5” x18 Hard Drives With Two Motherboards Figure 1-6. Front Panel−2.5” x24 Hard Drives With Two Motherboards Figure 1-7. Front Panel−2.5” x24 Hard Drives With One ...

[Page 14] Dell PowerEdge C6145

14 | About Your System Item Indicator, Button Or Connector Icon Description 1,3 Power-on indicator/ power button (motherboards 1,2) The power-on indicator lights when the system power is on. The power button controls the DC...

[Page 15] Dell PowerEdge C6145

About Your System | 15 Hard-Drive Indicator Patterns Figure 1-8. Hard-Drive Indicators 1 hard-drive activity indicator (green) 2 hard-drive status indicator (green and amber) Table 1-1. Hard-Drive Status Indicators−For 3.5&qu...

[Page 16] Dell PowerEdge C6145

16 | About Your System Table 1-2. Hard-Drive Status Indicators−For 3.5" Hard-Drive Backplane With Expander Hard Drive Type Function Activity LED Status LED Green Green Amber SAS Slot Empty Off Off Off Drive On- l...

[Page 17] Dell PowerEdge C6145

About Your System | 17 Table 1-3. Hard-Drive Status Indicators−For 2.5" Hard-Drive Backplane With Expander Hard Drive Type Function Activity LED Status LED Green Green Amber SAS Slot Empty Off Off Off Drive On- li...

[Page 18] Dell PowerEdge C6145

18 | About Your System Figure 1-10. Back Panel−One Motherboard Item Indicator, Button Or Connector Icon Description 1 Power supply 2 1100 W/1400 W 2 Power supply 1 1100 W/1400 W 3 NIC connector 1 Embedded 10/1...

[Page 19] Dell PowerEdge C6145

About Your System | 19 Item Indicator, Button Or Connector Icon Description 9 USB port 0 Connects USB devices to the system. The ports are USB 2.0-compliant. 10 USB port 1 Connects USB devices to the system. The ports are USB 2...

[Page 20] Dell PowerEdge C6145

20 | About Your System NIC Indicator Codes Figure 1-11. NIC Indicators 1 speed indicator 2 link/activity indicator NIC Status Indicator (Speed) Condition Solid green Linking at 100 Mbps speed Blinking green Port identificatio...

[Page 21] Dell PowerEdge C6145

About Your System | 21 Figure 1-12. NIC Indicators (BMC Management Port) 1 speed indicator 2 link/activity indicator NIC Status Indicator (Speed) Condition Green Linking at 100 Mbps speed Off Linking at 10 Mbps speed when th...

[Page 22] Dell PowerEdge C6145

22 | About Your System Power and System Board Indicator Codes The LEDs on the system front panel and back panel display status codes during system startup. For location of the LEDs on the front panel, see Figure 1-1 for 3.5 " hard dri...

[Page 23] Dell PowerEdge C6145

About Your System | 23 Power Supply Indicator Codes Figure 1-13. Power Supply Status Indicator 1 power supply 2 AC power LED AC Power LED Condition Solid green Power supply is on (AC OK/DC OK) or in standby mode (100 VAC-1...

[Page 24] Dell PowerEdge C6145

24 | About Your System BMC Heart Beat LED The system board provides BMC heart beat LED (CR2) for BMC debugs. The BMC heart beat LED is green. When the system AC power is on, this LED will light. When BMC firmware is ready, the BMC heart be...

[Page 25] Dell PowerEdge C6145

About Your System | 25 Post Error Code Collecting System Event Log (SEL) for Investigation Whenever possible, the BIOS will output the current boot progress codes on the video screen. Progress codes are 32-bit quantities plus optional data....

[Page 26] Dell PowerEdge C6145

26 | About Your System Error Code Error Message Error Cause Recovery Method 0012h CMOS Date/Time Not Set Indicate invalid date/time in CMOS diagnostic status byte Reset Date/Time 0040h Refresh Timer Test Failed Unrecoverable sy...

[Page 27] Dell PowerEdge C6145

About Your System | 27 Error Code Error Message Error Cause Recovery Method 0082h Secondary Master Drive-ATAPI Incompatible HDD/ATAPI/IDE device failure Change HDD 0083h Secondary Slave Drive- ATAPI Incompatible HDD/ATAPI/IDE devi...

[Page 28] Dell PowerEdge C6145

28 | About Your System Error Code Error Message Error Cause Recovery Method range 0-0Fh can be assigned to IO APICs. (Re-assigning CPUs’ local APIC ID may solve this issue) MPS Table is not built! System may operate in PIC or N...

[Page 29] Dell PowerEdge C6145

About Your System | 29 Sensor# Sensor Name Event Event Log - Deasserted 62h Processor 2 Temp Upper non-critical event asserted Processor 2 Temp Temperature Upper Non- Critical - Going High - Asserted Upper critical event ...

[Page 30] Dell PowerEdge C6145

30 | About Your System Sensor# Sensor Name Event Event Log Upper non-recoverable event asserted Processor 1 Temp Temperature Upper Non- Recoverable - Going High - Asserted Upper non-critical event deasserted Processor 1 Temp...

[Page 31] Dell PowerEdge C6145

About Your System | 31 Sensor# Sensor Name Event Event Log Upper non-recoverable event deasserted Processor 2 Temp Temperature Upper Non- Recoverable - Going High - Deasserted 21h MLB TEMP 1 Upper non-critical event asserte...

[Page 32] Dell PowerEdge C6145

32 | About Your System Sensor# Sensor Name Event Event Log Upper non-recoverable event asserted MLB TEMP 2 Temperature Upper Non- Recoverable - Going High - Asserted Upper non-critical event deasserted MLB TEMP 2 Temperatur...

[Page 33] Dell PowerEdge C6145

About Your System | 33 Sensor# Sensor Name Event Event Log Upper non-recoverable event deasserted MLB TEMP 3 Temperature Upper Non- Recoverable - Going High - Deasserted 24h MLB TEMP 4 Upper non-critical event asserted MLB...

[Page 34] Dell PowerEdge C6145

34 | About Your System Sensor# Sensor Name Event Event Log Lower critical event asserted PS 12V Voltage Lower Critical - Going Low - Asserted Lower non-recoverable event asserted PS 12V Voltage Lower Non-Recoverable - Going...

[Page 35] Dell PowerEdge C6145

About Your System | 35 Sensor# Sensor Name Event Event Log Lower critical event asserted PS 5V Voltage Lower Critical - Going Low - Asserted Lower non-recoverable event asserted PS 5V Voltage Lower Non- Recoverable - Going Lo...

[Page 36] Dell PowerEdge C6145

36 | About Your System Sensor# Sensor Name Event Event Log Lower critical event asserted STBY 3.3V Voltage Lower Critical - Going Low - Asserted Lower non-recoverable event asserted STBY 3.3V Voltage Lower Non-Recoverable -...

[Page 37] Dell PowerEdge C6145

About Your System | 37 Sensor# Sensor Name Event Event Log Lower critical event asserted PS 5V Voltage Lower Critical - Going Low - Asserted Lower non-recoverable event asserted PS 5V Voltage Lower Non- Recoverable - Going Lo...

[Page 38] Dell PowerEdge C6145

38 | About Your System Sensor# Sensor Name Event Event Log Lower critical event asserted STBY 3.3V Voltage Lower Critical - Going Low - Asserted Lower non-recoverable event asserted STBY 3.3V Voltage Lower Non-Recoverable -...

[Page 39] Dell PowerEdge C6145

About Your System | 39 Sensor# Sensor Name Event Event Log Lower critical event asserted PS 5V Voltage Lower Critical - Going Low - Asserted Lower non-recoverable event asserted PS 5V Voltage Lower Non- Recoverable - Going Lo...

[Page 40] Dell PowerEdge C6145

40 | About Your System Sensor# Sensor Name Event Event Log A6h PSU 1 Present Presence detected PSU 1 Present Presence detected - Deasserted Configuration Error PSU 1 Present Configuration Error - Asserted A7h PSU 2 Pre...

[Page 41] Dell PowerEdge C6145

About Your System | 41 Sensor# Sensor Name Event Event Log Asserted reset PEF Action System Event PEF Action reset - Asserted power cycle PEF Action System Event PEF Action power cycle - Asserted Diagnostic Interrupt (...

[Page 42] Dell PowerEdge C6145

42 | About Your System Sensor# Sensor Name Event Event Log SEL Full SEL Full - Asserted SEL Almost Full SEL Almost Full - Asserted Sensor Type: Platform Security Violation Attempt 75h Security Out-of-band Access Passwo...

[Page 43] Dell PowerEdge C6145

About Your System | 43 Sensor# Sensor Name Event Event Log (Web UI output) Correctable Memory error logging limit reached Correctable Memory error logging limit reached - Asserted Memory Single/Multi bits Error Event (Single ...

[Page 44] Dell PowerEdge C6145

44 | About Your System Byte Item Data 4-7 Timestamp - 8-9 Generator ID 0x31 10 Event Message Format Version 0x04 (IPMI 2.0) 11 Sensor Type 0x0F (POST Error) 12 Sensor Number 0x06 13 Event Direction/Event Type 0x6F 14 Eve...

[Page 45] Dell PowerEdge C6145

About Your System | 45 Recovery Mode NOTE: Boot block will be reserved. A BIOS recovery can be accomplished from one of the following devices: an USB Disk-On-Key or the CD-ROM. The recovery media must include the BIOS image file AMI...

[Page 46] Dell PowerEdge C6145

2 46 | Using the System Setup Program Using the System Setup Program Start Menu The system employs the latest AMI CMOS BIOS, which is stored in Flash memory. The Flash memory supports the Plug and Play specification, and contains a System...

[Page 47] Dell PowerEdge C6145

Using the System Setup Program | 47 Console Redirection The console redirection allows a remote user to diagnose and fix problems on a server, which has not successfully booted the OS. The centerpiece of the console redirection is the BIOS ...

[Page 48] Dell PowerEdge C6145

48 | Using the System Setup Program b) Make sure BMC NIC under the IPMI configuration. If users select dedicated NIC, make sure the LAN cable has been plugged in the dedicated port.  If users have the DHCP server, select BMC IP addre...

[Page 49] Dell PowerEdge C6145

Using the System Setup Program | 49 Main Menu The main menu displays information about your system boards and BIOS. Main Screen ...

[Page 50] Dell PowerEdge C6145

50 | Using the System Setup Program NOTE: The information about BMC/FCB/Asset Tag/Service Tag/ePPID shown in the main menu is different in each server. NOTE: The options for the System Setup program change based on the system con...

[Page 51] Dell PowerEdge C6145

Using the System Setup Program | 51 Processor Option Description Name Displays the processor name. Speed Displays the maximum speed of the processor. Count Displays the physical processor count. System Memory Option Description Siz...

[Page 52] Dell PowerEdge C6145

52 | Using the System Setup Program Advanced Menu This option displays a table of items that defines advanced information about your system. CAUTION: Making incorrect settings to items on these pages may cause the system to malfuncti...

[Page 53] Dell PowerEdge C6145

Using the System Setup Program | 53 Option Description USB Configuration Configure the USB support. PCI Configuration Configure PCI. Hyper Transport Configuration Configure Hyper Transport. Power cycle is recommended after change setti...

[Page 54] Dell PowerEdge C6145

54 | Using the System Setup Program Option Description Module Version Displays the current processor module version. Node Count Displays the node count. Core Count Displays the processor core count. Revision Displays the processor...

[Page 55] Dell PowerEdge C6145

Using the System Setup Program | 55 Option Description DRAM Prefetcher (Enabled default) Select this item to enable or disable DRAM Prefetcher. Hardware Prefetcher (Enabled default) Select this item to enable or disable the hardware p...

[Page 56] Dell PowerEdge C6145

56 | Using the System Setup Program Power Management Maximum Performance Scroll to this item and press Enter to view the following screen: ...

[Page 57] Dell PowerEdge C6145

Using the System Setup Program | 57 Option Description Power Management (Maximum Performance default) Set Power mode. If select Maximum Performance PowerNow function will be disabled. If select OS control or APML, PowerNow functi...

[Page 58] Dell PowerEdge C6145

58 | Using the System Setup Program Power Management Advanced Platform Management Link Scroll to this item and press Enter to view the following screen: Option Description APML Selects Power Management to AMD Advanced Platfo...

[Page 59] Dell PowerEdge C6145

Using the System Setup Program | 59 Memory Configuration Scroll to this item and press Enter to view the following screen: Option Description CS Sparing Enable (Disabled default) Reserves a spare memory rank in each channel. This ...

[Page 60] Dell PowerEdge C6145

60 | Using the System Setup Program IDE Configuration Scroll to this item and press Enter to view the following screen: ...

[Page 61] Dell PowerEdge C6145

Using the System Setup Program | 61 Option Description OnChip SATA Channel (Enabled default) Select this item to enable or disable Onboard SATA controller. OnChip SATA Type (Native IDE default) Native IDE: Native mode. AMD_AHCI: ...

[Page 62] Dell PowerEdge C6145

62 | Using the System Setup Program Option Description IDE Detect Time Out(Sec) (35 Sec. default) Select the time out value for detecting ATA/ATAPI device(s). Power Saving Features (Disabled default) Disables/Enables power saving...

[Page 63] Dell PowerEdge C6145

Using the System Setup Program | 63 AHCI Port0 Scroll to this item and press Enter to view the following screen: Option Description SATA Port0 (Auto default) Select SATA Port0 to Auto. S.M.A.R.T S.M.A.R.T stands for Self-Mo...

[Page 64] Dell PowerEdge C6145

64 | Using the System Setup Program USB Configuration Scroll to this item and press Enter to view the following screen: Option Description Module Version Displays the module version. USB Devices Enabled Displays USB devices curr...

[Page 65] Dell PowerEdge C6145

Using the System Setup Program | 65 Option Description BIOS EHCI Hand-Off (Enabled default) This is a workaround for operating systems without EHCI hand-off support. The EHCI ownership change should claim by EHCI driver. Legacy USB1.1 ...

[Page 66] Dell PowerEdge C6145

66 | Using the System Setup Program Option Description (Enabled default) ROM” is shown in SETUP screen when PXE or iSCSI is set. NIC2 Option ROM (Enabled default) Sets OnBoard 82576EB and disables/enables Option ROM. The “NIC2 Op...

[Page 67] Dell PowerEdge C6145

Using the System Setup Program | 67 PCIE Slot/Onboard LAN/Mezzing Slot ASPM Scroll to one of these three items and press Enter to view the following screen: Option Description Link ASPM (Disabled default) For ATI GFX Card: M2x...

[Page 68] Dell PowerEdge C6145

68 | Using the System Setup Program NB-SB Port Features Scroll to this item and press Enter to view the following screen: Option Description Link ASPM (L1 default) Sets this item to L1 or to disable. ...

[Page 69] Dell PowerEdge C6145

Using the System Setup Program | 69 Hyper Transport Configuration Option Description Coherent HT Link Speed (HT3 default) Coherent HT Link Frequency Non-Coherent HT Link Speed (HT3 2600MHz default) Non-Coherent HT Link Frequency ...

[Page 70] Dell PowerEdge C6145

70 | Using the System Setup Program I/O Virtualization Option Description SR-IOV Supported (Disabled default) Sets this item to enable or to disabe. ...

[Page 71] Dell PowerEdge C6145

Using the System Setup Program | 71 Boot Menu This page enables you to set POST boot parameters. Scroll to this item and press Enter to view the following screen: Option Description Boot Settings Configuration Configure Setti...

[Page 72] Dell PowerEdge C6145

72 | Using the System Setup Program Option Description USB Drives Specifies the Boot Device Priority sequence from available USB Drives. Network Drives Specifies the Boot Device Priority sequence from available Network Drives. ...

[Page 73] Dell PowerEdge C6145

Using the System Setup Program | 73 Option Description messages. Wait For ‘F1’ if Error (Disabled default) Wait for F1 key to be pressed if error occurs. Hit ‘F2’ Message Display (Enabled default) Displays “Press F2 to ...

[Page 74] Dell PowerEdge C6145

74 | Using the System Setup Program Boot Device Priority Select this item and press Enter to view the following submenu items: ...

[Page 75] Dell PowerEdge C6145

Using the System Setup Program | 75 Hard Disk Drives Scroll to this item and press Enter to view the following screen: ...

[Page 76] Dell PowerEdge C6145

76 | Using the System Setup Program Removable Drives Scroll to this item and press Enter to view the following screen: ...

[Page 77] Dell PowerEdge C6145

Using the System Setup Program | 77 CD/DVD Drives Scroll to this item and press Enter to view the following screen: ...

[Page 78] Dell PowerEdge C6145

78 | Using the System Setup Program USB Drives Scroll to this item and press Enter to view the following screen: ...

[Page 79] Dell PowerEdge C6145

Using the System Setup Program | 79 Network Drives Scroll to this item and press Enter to view the following screen: ...

[Page 80] Dell PowerEdge C6145

80 | Using the System Setup Program Security Menu This page enables you to set the security parameters. Scroll to this item and press Enter to view the following screen: Option Description Supervisor Password Displays wheth...

[Page 81] Dell PowerEdge C6145

Using the System Setup Program | 81 Option Description set. Password Check (Setup default) Setup: Checks password while invoking setup. Always: Checks password while invoking setup as well as on each boot. This item is only shown...

[Page 82] Dell PowerEdge C6145

82 | Using the System Setup Program Server Menu This page enables you to configure Server parameters. Scroll to this item and press Enter to view the following screen: Option Description WHEA Support (Disabled default) Enabl...

[Page 83] Dell PowerEdge C6145

Using the System Setup Program | 83 Option Description Random: Randomly select time to power on. User define: User selects the time. The “Delay Time” will be shown in the Setup screen when “AC Power Recovery Delay” is set to “Us...

[Page 84] Dell PowerEdge C6145

84 | Using the System Setup Program System Management Scroll to this item and press Enter to view the following screen: ...

[Page 85] Dell PowerEdge C6145

Using the System Setup Program | 85 Remote Access Configuration Scroll to this item and press Enter to view the following screen: Option Description Remote Access (Disabled default) Select remote access type. Serial Port Number ...

[Page 86] Dell PowerEdge C6145

86 | Using the System Setup Program Option Description Hyper Terminal on remote side will be discontinued when <Ctrl>+<S> key is pressed. But onboard NIC PXE Option ROM Configuration is also set when <Ctrl>+<S> ...

[Page 87] Dell PowerEdge C6145

Using the System Setup Program | 87 IPMI Configuration Scroll to this item and press Enter to view the following screen: Option Description Set BMC NIC (Shared default) Sets the type of BMC NIC from BIOS. BMC will reset. BMC IP ...

[Page 88] Dell PowerEdge C6145

88 | Using the System Setup Program IP Address Configuration Select IP Address item in the IPMI Configuration screen to view the following submenu: Option Description IP Address Enter IP address in decimal in the form of XXX.X...

[Page 89] Dell PowerEdge C6145

Using the System Setup Program | 89 Subnet Mask Configuration Select Subnet Mask item in the IPMI Configuration screen to view the following submenu: Option Description Subnet Mask Enter Subnet Mask in decimal in the form of XXX...

[Page 90] Dell PowerEdge C6145

90 | Using the System Setup Program Default Gateway IP Configuration: Select Default Gateway IP item in the IPMI Configuration screen to view the following submenu: Option Description Default Gateway IP Enter Default Gateway IP i...

[Page 91] Dell PowerEdge C6145

Using the System Setup Program | 91 Exit Menu Scroll to this item and press Enter to view the following screen: Option Description Save Changes and Exit Exit system setup after saving the changes. F10 key can be used for this opera...

[Page 92] Dell PowerEdge C6145

92 | Using the System Setup Program Option Description Save Customized Defaults Saves the changes as User Defaults. Load Customized Defaults Loads the User Defaults to all the setup options. Command Line Interface for Setup Options Th...

[Page 93] Dell PowerEdge C6145

Using the System Setup Program | 93 Token Setup Option Description ROMs (if the devices are available) 0053 BOOTSEQ_DEVLST For the next system boot, set the IPL priority to: diskette, IDE CD-ROM, hard drive, option ROMs (if the devic...

[Page 94] Dell PowerEdge C6145

94 | Using the System Setup Program Token Setup Option Description 00C0 Remote Access Serial Console Redirection On, output to COM1. See also token D7h. 00CA CS Sparing Enabled Disable Redundant memory. 00CB CS Sparing Enabled En...

[Page 95] Dell PowerEdge C6145

Using the System Setup Program | 95 Token Setup Option Description summary screen. The user is able to see the detail of the POST messages. 026F CPU DownCore Mode Enable CPU 6 cores only. 0270 CPU DownCore Mode Enable CPU 8 core only...

[Page 96] Dell PowerEdge C6145

96 | Using the System Setup Program Token Setup Option Description device as the system’s onboard network controller, if present and enabled, or the first bootable network device found in the system’s standard PCI search order �...

[Page 97] Dell PowerEdge C6145

Using the System Setup Program | 97 Token Setup Option Description 482A Serial port number Console redirection to COM1. 482B Terminal Type The BIOS console redirection, if enabled, operates in VT-UTF8 emulation model. See also tokens...

[Page 98] Dell PowerEdge C6145

98 | Using the System Setup Program Token Setup Option Description Ctrl 4873 SATA-IDE Ports Auto Clk Ctrl Disable SATA-IDE port clock control. 4874 SATA-IDE Ports Auto Clk Ctrl Enable SATA-IDE port clock control. 4877 L3 Power C...

[Page 99] Dell PowerEdge C6145

Using the System Setup Program | 99 Token Setup Option Description 5022 Onboard Lan ASPM Set Onboard NIC ASPM to L0. 5023 Onboard Lan ASPM Set Onboard NIC ASPM to L1. 5024 Onboard Lan ASPM Set Onboard NIC ASPM to L0 & L1. 5091 ...

[Page 100] Dell PowerEdge C6145

100 | Using the System Setup Program Table 2-2. The IPMI Command Table IPMI Command Setup Option Description ipmitool raw 0x34 0xB1 <Byte1:4> Byte 1 - Power Management Enable(01h enable) Byte 2 - Power Capping Enable(01h...