[Page 1] Enviro E33

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE 50-2517 Massachusetts installations (Warning): This product must be installed by a ...

[Page 2] Enviro E33

FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-red appliances must be installed in accordance with their instructions. Carefully read all the in...

[Page 3] Enviro E33

Table of Contents 3 Safety Precautions...........................................................................................................2 Table of Contents........................................................................................

[Page 4] Enviro E33

DIRECT VENT: This type is identied by the sufx DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved for installations from ...

[Page 5] Enviro E33

Specifications Rating LabeL Location: The rating label is located on the left side of the unit, next to the fan controller. Dimensions: 5 Figure 1: E33 Exterior Dimensions. 33.00 28.89 27.05 16.64 18.55 .25 14.05 11.24 22.16 9.069.09 19.78 17.40 21.5...

[Page 6] Enviro E33

6 Specifications Figure 2: E33 Contemporary Surround with Base Shelf and Riser. Table 1: E33 Options Dimensions. Regular Surround Contemporary Surround Extruded Surround Height 26.5” (673 mm) 26.5” (673 mm) 26.5” (673 mm) Width 44 1 /8” (11...

[Page 7] Enviro E33

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. Lighting anD tuRning off instRuctions: Figure 3: Lighting instruction label. Operating Instructions F...

[Page 8] Enviro E33

Operating Instructions 8 Figure 4. Pilot Flame PiLot Light: 1. Turn off the gas to the replace. If not recently done, remove the glass and let the unit air out for at least ve (5) minutes to clear out any gas. Turn on gas to th...

[Page 9] Enviro E33

9 Operating InstructionsOperating Instructions buRneR Lighting: bLoweR sPeeD: The blower will come on only when the replace is up to temperature (approximately 15 minutes). The fan controller knob can be found to the left of the door, behind the ...

[Page 10] Enviro E33

Maintenance And Service Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specically approved with this appliance, may result in property damage or personal injury. At least once a...

[Page 11] Enviro E33

11 Maintenance And Service gLass DooR RemoVaL: cLeaning the PainteD suRfaces: Painted surfaces should be periodically wiped with a damp cloth when the unit is cool. Warning: Do not touch or attempt to remove the glass if the replace is not complet...

[Page 12] Enviro E33

12 Maintenance And Service RemoVing VaLVe coVeR: The valve cover can be removed to access the gas valve. 1. Use a T-20 screwdriver to remove the eight screws that hold down the valve cover shown in Fig. 10. Figure 10: Valve Cover. VALVE COVER ...

[Page 13] Enviro E33

13 WARNING: This conversion kit shall be installed by a qualied service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in the...

[Page 14] Enviro E33

Fuel Conversion 14 Loosen Tighten Figure 12: Removing valve screw. Figure 13: Flip valve screw. Red o-ring is not visible Red o-ring is visible LPG Configuration 8. Reinstall the burner, brick panels, log set, embers, and glass door. Also ref...

[Page 15] Enviro E33

15 Initial Installation WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. cLeaRances to combustibLes: Figure 16: Mantle width...

[Page 16] Enviro E33

16 Table 4: Vent termination clearances Minimum Clearance Description 3 ft (0.9 m) Clearance above the highest point where it passes through a roof surface, refer to Figure 17. 24 in (0.6 m) Clearance above a roof ridge, any other portion of a buil...

[Page 17] Enviro E33

17 Initial Installation QUALIFIED INSTALLERS ONLY Figure 19: Installation of E33 DV . Figure 18: Generic Vent Cap Underside. 3" (76mm) Exhaust 3" (76mm) Intake The height for the vent must be between 8 ft (2.44 m) and 30 ft (9.14 m). Instal...

[Page 18] Enviro E33

18 18" (457mm) 18" (457mm) Trim flashing as required. Figure 20: Generic Vent Cap Dimensions. Initial Installation QUALIFIED INSTALLERS ONLY DiRect Vent VeRticaL Vent teRmination: instaLLation instRuctions: 1. Plan your installation an...

[Page 19] Enviro E33

19 Initial Installation QUALIFIED INSTALLERS ONLY Figure 22: Levelling Legs Position. • Carefully clean the replace and ue before installing the stove. Failure to do so may result in fumes or soot being blown into the room and may cause a �...

[Page 20] Enviro E33

20 zeRo cLeaRance (zc) fiRePLace instaLLation: The metal oor of the ZC solid fuel rebox can be removed to allow the installation of the insert. THE CLEARANCE TO COMBUSTIBLE MATERIAL UNDER THE INSERT IS 4” (102 mm). YOU MUST USE THE LEVELING...

[Page 21] Enviro E33

21 Initial Installation QUALIFIED INSTALLERS ONLY eLectRicaL RequiRements: The fan will not operate if the appliance is cold. Once the unit is lit and the fan is set to the desired level, the fan will automatically turn on upon reaching operating te...

[Page 22] Enviro E33

Initial Installation QUALIFIED INSTALLERS ONLY 22 gas Line connection: WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. Gas Line Connection: • A ⅜” NPT male pipe ...

[Page 23] Enviro E33

TO TEST VALVE PRESSURES (INPUT RATES): The pressure taps are located on the front side of the valve (see Figure 27). 1. Remove valve control knobs. 2. Using a long at bladed screwdriver, turn set screw one (1) turn counter-clockwise to loosen. 3. ...

[Page 24] Enviro E33

24 aDjusting the PiLot fLame: The pilot ow adjustment is set to maximum at the factory and should not need to be adjusted. The pilot ame should envelope ⅜” to ½” (10 to 13mm) of the thermocouple (see Figure 28). However, should the nee...

[Page 25] Enviro E33

25 Secondary Installation oPtionaL base sheLf & RiseR: The E33 Base Shelf (1⅝” (41 mm) high) and Base Shelf Riser (2⅛” (54 mm) high) are components that can be combined to create a riser with an overall height of 2 3 /16” (55 mm). Thi...

[Page 26] Enviro E33

Secondary Installation oPtionaL 3 tRimmabLe PaneLs: Modifying the Surround Panel: The E33 Trimmable Surround Panels are large rectangular panels that may be cut for use in cases that a non- standard replace opening (e.g. an arched opening) is to ...

[Page 27] Enviro E33

27 Secondary Installation suRRounD PaneL instaLLation: WARNING: The surround becomes hot when the unit is operating; ensure that the unit is turned off, and that it has cooled to room temperature before beginning this installation. Height Width 3-...

[Page 28] Enviro E33

fiRebox LineR anD buRneR tube RemoVaL: NOTE: The rebox liners are fragile and should be handled gently. 1. Ensure the E33 is turned off and allow the unit to cool. 2. Remove the glass door as shown in the maIntenance anD serVIce - glass Door rem...

[Page 29] Enviro E33

29 Secondary Installation Log set anD embeR instaLLation: NOTE: The logs are fragile and should be handled gently. Figure 39. Empty rebox. Figure 40. First Stage Log Set Installation. Figure 41. Second Stage Log Set Installation. Figure 40: The ...

[Page 30] Enviro E33

Secondary Installation Figure 42. Third Stage Log Set Installation. Figure 44. Fifth Stage Log Set Installation. Figure 43. Fourth Stage Log Set Installation. Figure 42: Place the log grate in front of the burner tube using the two slotted...

[Page 31] Enviro E33

31 Secondary Installation NOTE: While the glass is still removed, it is recommended that the gas line be purged by lighting the pilot. When lighting the replace for the rst time since the log set and embers have been installed/replac...

[Page 32] Enviro E33

Trouble Shooting 32 Problem Possible Cause Solution The main burner does not ignite when called for. The gas valve may not be on. • Check that the gas control knob is in the “ON” position. Thermostat is not calling for heat. • Adjust t...

[Page 33] Enviro E33

Parts List 33 Reference Number Part Description Part Number 1 DV Flue Adaptor Bottom Gasket 50-2516 - E33 Owner’s Manual 50-2517 - E33 Conversion Kit NG to LP 50-2514 - E33 Conversion Kit LP to NG 50-2518 2 Door Release Tool 50-2510 - Ceramic Wool...

[Page 34] Enviro E33

Reference Number Part Description Part Number 21 Door Latch Mechanism (Set of 2) 50-2524 - Log Set (9 pcs) 50-2508 - Brick Liner - E33 50-2525 22 S.I.T. Nova Valve Convertible 50-1421 23 120 Ceramic Fan Temp Sensor EC-001 - 12 oz. Can of Metall...

[Page 35] Enviro E33

Parts Diagram - Components 35 18 19 20 21 22 23 24 ...

[Page 36] Enviro E33

Parts Diagram - Options 36 26 27 28 30 29 25 31 ...

[Page 37] Enviro E33

37 Warranty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the highest level of quality and customer service is the most important thing we do. Each Envir...

[Page 38] Enviro E33

Warranty 4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s Manual. If the unit shows signs of neglect or misuse, it is not covered under the terms of this Warranty policy. Performance pro...

[Page 39] Enviro E33

39 20. Sherwood Industries Ltd. is free of liability for any damages caused by the replace or stove, as well as inconvenience expenses and materials. The Limited Warranty does not cover incidental or consequential damages. 21. The Limited Wa...

[Page 40] Enviro E33

40 Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ ___________...