Tyco F3200 Installation And Programming Manual

Download or browse on-line these Installation & Programming Manual for Tyco F3200 Fire Alarms, Measuring Instruments.

Tyco F3200 Manual Information:

This manual for Tyco F3200, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 284 pages, and the size of the file at download is 2.57 Mb. The document type is Installation & Programming Manual.

Download Manual

More Manuals:

In case you failed to obtain relevant information in this document, please, look through related operating manuals and user instructions for Tyco F3200. Just click one of the links below to go to the selected manual:

Summary of Contents:

[Page 1] Tyco F3200

F3200 FIRE INDICATOR PANEL INSTALLATION & PROGRAMMING MANUAL F3200 PRODUCT MANUAL Document Number: LT0122 Issue .......... 2.7; 5 July 2001 -- A P P R O V A L S -- AUSTRALIAN STANDARD AS1603.4 1987 (Incl. Amdt 1 & 2) AUSTRALIAN...

[Page 2] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Page ii 5 July 2001 Issue 2.7 TYCO SERVICES FIRE & SAFETY END USER LIABILITY DISCLAIMER The F3200 Fire Indicator Panel has a configuration programming facility which may be accesse...

[Page 3] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Issue 2.7 5 July 2001 Page iii TABLE OF CONTENTS End User Liability Disclaimer ...................................................................................................ii Amend...

[Page 4] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Page iv 5 July 2001 Issue 2.7 8.3 AZC WIRING.........................................................................................................................8-10 8.4 MAF ANCILL...

[Page 5] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Issue 2.7 5 July 2001 Page v AMENDMENTS ISSUE DATE COMMENTS ECN 1 20/04/94 Original. Corresponds to V1.10 software, which includes RZDUs, multiple access codes, revised print menu, NSW ...

[Page 6] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Page vi 5 July 2001 Issue 2.7 THIS PAGE IS INTENTIONALLY LEFT BLANK ...

[Page 7] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Introduction Issue 2.7 5 July 2001 Page 1-1 CHAPTER 1 INTRODUCTION ...

[Page 8] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Introduction Page 1-2 5 July 2001 Issue 2.7 1.1 SCOPE This manual provides information for the personnel responsible for planning, ordering, installing and programming an F3200 Fire Al...

[Page 9] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Introduction Issue 2.7 5 July 2001 Page 1-3 1.2 ASSOCIATED DOCUMENTATION 1.2.1 PRODUCT Additional information on the AS1603.4 approved F3200 FIP is found in the following product manuals...

[Page 10] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Introduction Page 1-4 5 July 2001 Issue 2.7 1.3 PRODUCT HISTORY LOG 1.3.1 HARDWARE Part No. Description Iss Rev Date Drawing PA0490 Controller/ A 1 11/11/93 1931-2 ...

[Page 11] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Introduction Issue 2.7 5 July 2001 Page 1-5 SOFTWARE HISTORY LOG (CONTINUED) SF0164 F3200 Net EPROM V2.06 Mar 1999 SF0175 NDU EPROM V2.06 Mar 1999 SF0178 F3200 Std EPROM V2.06 Mar 1999 S...

[Page 12] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Introduction Page 1-6 5 July 2001 Issue 2.7 1.4 GLOSSARY OF ABBREVIATIONS The following abbreviations are used throughout this manual: A/C : Air Conditioning ac : Alternating Curr...

[Page 13] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Introduction Issue 2.7 5 July 2001 Page 1-7 GLOSSARY OF ABBREVIATIONS (CONTINUED) VA : Volts Amperes VB : Battery Backed Voltage VNB : Non Battery Backed Voltage +VBF : Fused Battery-B...

[Page 14] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Introduction Page 1-8 5 July 2001 Issue 2.7 THIS PAGE INTENTIONALLY LEFT BLANK ...

[Page 15] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Description Issue 2.7 5 July 2001 Page 2-1 CHAPTER 2 SYSTEM DESCRIPTION ...

[Page 16] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Description Page 2-2 5 July 2001 Issue 2.7 2.1 OVERVIEW 2.1.1 GENERAL The F3200 is a self-contained, modular, intelligent Fire Indicator Panel (FIP) which performs the functions...

[Page 17] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Description Issue 2.7 5 July 2001 Page 2-3 FIG 2.1.1 F3200, STANDARD CABINET - FRONT VIEW ...

[Page 18] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Description Page 2-4 5 July 2001 Issue 2.7 FIG 2.1.2 F3200 OPERATOR DISPLAY PANEL ...

[Page 19] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Description Issue 2.7 5 July 2001 Page 2-5 FIG 2.1.3 F3200 - SMALL CABINET ...

[Page 20] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Description Page 2-6 5 July 2001 Issue 2.7 2.1.4 OUTPUTS The F3200 MAF/PSU Module provides 7 relays as standard. These are used for signalling to the Brigade (Fire Control Stat...

[Page 21] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Description Issue 2.7 5 July 2001 Page 2-7 2.2 PHYSICAL STRUCTURE The F3200 has a rugged, lockable painted steel cabinet, which houses 19 inch rack-mount equipment and comes in tw...

[Page 22] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Description Page 2-8 5 July 2001 Issue 2.7 Note: FP0551 and FP0713 have the cardframe as shown. FP0550 and FP0712 have the modules (3 max.) mounted on the rear wall. FIG 2.2.1 F...

[Page 23] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Description Issue 2.7 5 July 2001 Page 2-9 FIG 2.2.2 F3200, SMALL CABINET, MAXIMUM CONFIGURATIONS ...

[Page 24] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Description Page 2-10 5 July 2001 Issue 2.7 2.3 SYSTEM STRUCTURE 2.3.1 PCB MODULES The 6 printed circuit boards which are used in an F3200 are as follows: Controller/Display Mou...

[Page 25] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Description Issue 2.7 5 July 2001 Page 2-11 RS485 "Panel-Link" Network Board Connects to the Controller/Display Board Includes: RS485 Board used for connection to the Vi...

[Page 26] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Description Page 2-12 5 July 2001 Issue 2.7 2.3.2 INTER-CONNECTION & STRUCTURE A basic F3200 system has one Controller/Display, one MAF/PSU, and one 8 Zone Module, all conn...

[Page 27] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Description Issue 2.7 5 July 2001 Page 2-13 INTER-CONNECTION & STRUCTURE (CONTINUED) The relay LEDs simply follow the zone LEDs in the same order that they occur in the module...

[Page 28] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Description Page 2-14 5 July 2001 Issue 2.7 Zone Module Relay Display 1 1 ........1 1 8 ...

[Page 29] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Specifications Issue 2.7 5 July 2001 Page 3-1 CHAPTER 3 SYSTEM SPECIFICATIONS ...

[Page 30] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Specifications Page 3-2 5 July 2001 Issue 2.7 3.1 GENERAL 3.1.1 FIP PART NUMBER & DESCRIPTION Refer to Section 4 also. FP0550, F3200 FIP, NO CARDFRAME, 24 ZONE MAX, 1931-15...

[Page 31] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Specifications Issue 2.7 5 July 2001 Page 3-3 3.1.3 ENVIRONMENTAL Operating Temperature : -5°C to 45°C (Ambient) Relative Humidity : 95% maximum @ 40°C (non-condensing) 3.2 MEC...

[Page 32] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Specifications Page 3-4 5 July 2001 Issue 2.7 3.3 ELECTRICAL SPECIFICATIONS 3.3.1 MAINS SUPPLY Voltage : 240Vac +6% -10% Current : 0.5A Frequency : 50Hz Termination : For up to ...

[Page 33] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Specifications Issue 2.7 5 July 2001 Page 3-5 STATE MIN NOM MAX COMMENTS Charger High 28.05 28.125 28.20 Adjust with pot Charger Low 26.40 26.57 26.75 Battery Low 24.15 24.33 24.5...

[Page 34] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Specifications Page 3-6 5 July 2001 Issue 2.7 3.3.5 CURRENT CONSUMPTION 3.3.5.1 F3200 Quiescent & Alarm Currents At 24Vdc battery supply, nominal currents: Quiescent Alarm ...

[Page 35] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Specifications Issue 2.7 5 July 2001 Page 3-7 3.3.5.2 NDU Quiescent and Alarm Currents Slimline NDU (FP0714/FP0773/FP0774 4 ) Operating Voltage : 24Vdc (18-28V) Termination : For...

[Page 36] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Specifications Page 3-8 5 July 2001 Issue 2.7 3.4 INPUT SPECIFICATIONS 3.4.1 AZC SPECIFICATIONS General Terminations On 8 Zone Module, 2 per AZC. Demountable screw terminal 1.5s...

[Page 37] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Specifications Issue 2.7 5 July 2001 Page 3-9 AZC SPECIFICATIONS (CONTINUED) Min Typ Max AZC current limit (note 1) 13.5mA 15.5mA 16.5mA (14.5mA) EOL & detect...

[Page 38] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Specifications Page 3-10 5 July 2001 Issue 2.7 AZC SPECIFICATIONS (CONTINUED) Detector Alarm Currents The current available to a latched detector is the AZC supply current at ...

[Page 39] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Specifications Issue 2.7 5 July 2001 Page 3-11 ICL+R = Current sourced through current limit and pull up resistor IAV = Current available to detectors with EOLR fitted IAV = ICL+R...

[Page 40] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Specifications Page 3-12 5 July 2001 Issue 2.7 AZC SPECIFICATIONS (CONTINUED) Timing Standard Delay 2.3 sec (2.0 - 2.6 sec) (into Alarm, Fault, Normal) AZC Reset 5.3 sec (5.0 ...

[Page 41] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Specifications Issue 2.7 5 July 2001 Page 3-13 MAF/PSU INPUTS (CONTINUED) End of Line Resistor No. of Circuits Type 1 3k3, 5%, 250mW resistor 2 6k8, 5%, 250mW resistor 3 10k, 5%, ...

[Page 42] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Specifications Page 3-14 5 July 2001 Issue 2.7 3.5 OUTPUT SPECIFICATIONS 3.5.1 8 ZONE MODULE OUTPUTS Type Darlington open collector Switch to 0V Voltage Rating 28.5V max, "...

[Page 43] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Specifications Issue 2.7 5 July 2001 Page 3-15 3.5.3 MAF/PSU OUTPUTS Brigade Relays Number 4 Standby Normally energised De-energises on battery fail or panel fail Fault, Isolated,...

[Page 44] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Specifications Page 3-16 5 July 2001 Issue 2.7 MAF/PSU OUTPUTS (CONTINUED) Option 1 Pole changeover contacts Voltage-free Snip Links Lk2, 3, 4. Rating ELV only 30V, 2Adc resis...

[Page 45] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Specifications Issue 2.7 5 July 2001 Page 3-17 MAF/PSU OUTPUTS (CONTINUED) Non-Battery Backed DC Supply Rating 28Vdc nom 2Adc, fused +VNBF Termination 1 non-demountable screw te...

[Page 46] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Specifications Page 3-18 5 July 2001 Issue 2.7 CONTROLLER/DISPLAY (CONTINUED) Pin 2 3 5 1 4 6 7 8 Tx Rx 0V └──┴──┘ └──┘ ...

[Page 47] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual System Specifications Issue 2.7 5 July 2001 Page 3-19 3.6 CONTROLS KEYPAD Type : Polyester Membrane Keypress : Buzzer gives short "beep" for valid keypress Number of Keys : 34 ...

[Page 48] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 System Specifications Page 3-20 5 July 2001 Issue 2.7 3.7 DISPLAYS Standard Display Includes : LCD; FFCIF LEDs; System Status LEDs Panel Size : 19", 4U FFCIF Type : 3 (common indi...

[Page 49] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Ordering Information Issue 2.7 5 July 2001 Page 4-1 CHAPTER 4 ORDERING INFORMATION ...

[Page 50] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Ordering Information Page 4-2 5 July 2001 Issue 2.7 4.1 ORDERING INFORMATION The following lists the part numbers for the range of products and spares associated with the AS1603.4 approv...

[Page 51] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Ordering Information Issue 2.7 5 July 2001 Page 4-3 ORDERING INFORMATION (CONTINUED) FP0712,FP,F3200 FIP,NO CARDFRAME,24 ZONE MAX,6A PSU FP0713,FP,F3200,FIP,64 ZONE MAX,6A PSU FP0714,F...

[Page 52] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Ordering Information Page 4-4 5 July 2001 Issue 2.7 ORDERING INFORMATION (CONTINUED) LM0042,LOOM,1888-62,PROG PORT TO 25 PIN SERIAL (cable to connect printer/computer to Controller, ha...

[Page 53] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Ordering Information Issue 2.7 5 July 2001 Page 4-5 ORDERING INFORMATION (CONTINUED) ME0069,MECH ASSY,1931-57,1 ZONE, 1U GAS CONTROL PANEL (similar to ME0065 except on a non-hinged, 1U...

[Page 54] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Ordering Information Page 4-6 5 July 2001 Issue 2.7 ORDERING INFORMATION (CONTINUED) NEW ZEALAND OPERATION ONLY A variety of display options are available to satisfy varying NZ require...

[Page 55] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Configuring a FIP Issue 2.7 5 July 2001 Page 5-1 CHAPTER 5 CONFIGURING A FIP ...

[Page 56] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Configuring a FIP Page 5-2 5 July 2001 Issue 2.7 5.1 GENERAL An F3200 FIP is configured to suit a particular customer's requirements by: Fitting and connecting the required pcb modu...

[Page 57] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Configuring a FIP Issue 2.7 5 July 2001 Page 5-3 5.3 BATTERY & POWER SUPPLY 5.3.1 GENERAL The F3200 FIP has a dc power supply, which also serves as battery charger and requires a 24...

[Page 58] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Configuring a FIP Page 5-4 5 July 2001 Issue 2.7 GENERAL (CONTINUED) 4. The approvals laboratory recommends using 90% derating of batteries used on F3200 because the battery fail volta...

[Page 59] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Configuring a FIP Issue 2.7 5 July 2001 Page 5-5 5.3.3 EXAMPLE BATTERY/CHARGER CALCULATIONS An example FP0551 FIP has the following configuration: 3 8ZMs total (i.e. 2 x FP0553 expansio...

[Page 60] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Configuring a FIP Page 5-6 5 July 2001 Issue 2.7 Suggest that two 12V, 10 Ahr sealed batteries from list in Section 3.3.3. would be adequate (or next size up, e.g. 17 Ahrs). Note that th...

[Page 61] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Configuring a FIP Issue 2.7 5 July 2001 Page 5-7 5.3.5 BATTERY TEST RESISTORS The standard battery test resistor is suitable for a battery of capacity of up to 6.5AHr. For larger batteri...

[Page 62] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Configuring a FIP Page 5-8 5 July 2001 Issue 2.7 A. FOR ADDITIONAL TEST LOAD GREATER THAN 0.7A AND ALARM LOAD/CHARGER CURRENT LESS THAN 3A. B. FOR ALARM LOAD/CHARGER CURRENT GREATER THAN...

[Page 63] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Configuring a FIP Issue 2.7 5 July 2001 Page 5-9 5.3.6 BATTERY OVERCURRENT PROTECTION The MAF/PSU has two parallel PTCs, rated to carry over 3A, for battery overcurrent protection. Where...

[Page 64] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Configuring a FIP Page 5-10 5 July 2001 Issue 2.7 POWERING AN F3200 FROM AN EXTERNAL DC SUPPLY (CONTINUED) Without a mains connection, F3200 will indicate “Mains Fail” in a system fa...

[Page 65] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Configuring a FIP Issue 2.7 5 July 2001 Page 5-11 5.4 LINKS ON PCB MODULES 5.4.1 CONTROLLER/DISPLAY Apart from E2INIT (SW1) and DATABASE WRITE PROTECT/ENABLE (Lk7) all links on the Cont...

[Page 66] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Configuring a FIP Page 5-12 5 July 2001 Issue 2.7 5.5 ERROR MESSAGES DURING FIP CONFIGURATION Listed below are some error messages that can appear on the LCD during installation. Refer...

[Page 67] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Programming Issue 2.7 5 July 2001 Page 6-1 CHAPTER 6 PROGRAMMING ...

[Page 68] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Programming Page 6-2 5 July 2001 Issue 2.7 6.1 INTRODUCTION 6.1.1 GENERAL The F3200 has two main levels of programming. The first level is accessible to the Operator (via the keypad) an...

[Page 69] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Programming Issue 2.7 5 July 2001 Page 6-3 GENERAL (CONTINUED) If "CLEAR ESC" is pressed enough times, the programming mode display is exited and the database checksum is cal...

[Page 70] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Programming Page 6-4 5 July 2001 Issue 2.7 THIS PAGE LEFT INTENTIONALLY BLANK ...

[Page 71] Tyco F3200

...

[Page 72] Tyco F3200

...

[Page 73] Tyco F3200

...

[Page 74] Tyco F3200

...

[Page 75] Tyco F3200

...

[Page 76] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Programming Page 6-10 5 July 2001 Issue 2.7 6.1.3 PROGRAMMING KEYS Looking at the keypad (or picture in Fig 2.1.2) the user will observe a 4x4 "numeric" keypad, and a row of fu...

[Page 77] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Programming Issue 2.7 5 July 2001 Page 6-11 6.1.5 RECOMMENDED PROCEDURE FOR CONFIGURATION & PROGRAMMING (CONTINUED) 10 Checking When all parameters are entered, either: 1. Print th...

[Page 78] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Programming Page 6-12 5 July 2001 Issue 2.7 6.2 SET MENU & OPERATOR PROGRAMMING FUNCTIONS 6.2.1 GENERAL From the base display, pressing the "SET" key enters the programmi...

[Page 79] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Programming Issue 2.7 5 July 2001 Page 6-13 6.3 INITIALISING, ACCESSING, DE-ACCESSING, PRINTING, SAVING, LOADING & VERIFYING THE DATABASE 6.3.1 INITIALISING THE DATABASE The E2 INI...

[Page 80] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Programming Page 6-14 5 July 2001 Issue 2.7 ACCESSING THE DATABASE (CONTINUED) WARNINGS 1. When the database is accessed the Controller de-energises the Standby relay (i.e. transmi...

[Page 81] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Programming Issue 2.7 5 July 2001 Page 6-15 PRINTING & SAVING THE DATABASE (CONTINUED) To print or save the database, use the PRINT key from the base display (i.e. press CLEAR/ESC re...

[Page 82] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Programming Page 6-16 5 July 2001 Issue 2.7 RESTORING THE DATABASE FROM A COMPUTER (CONTINUED) Note: The FIP will transmit XON, XOFF characters for handshaking if it needs to slow down t...

[Page 83] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Programming Issue 2.7 5 July 2001 Page 6-17 6.4 PROGRAM DATA MENU, TEXT & GLOBAL PARAMETERS 6.4.1 GENERAL The Program Data menu (refer to Fig 6.1.2) allows the user to program the ...

[Page 84] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Programming Page 6-18 5 July 2001 Issue 2.7 6.4.3 TEXT ENTRY The Text option allows entry of the following: 1. a 40 character name for the site 2. a 30 character name for each zone 3. a ...

[Page 85] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Programming Issue 2.7 5 July 2001 Page 6-19 PROGRAMMING TEXT WITH THE KEYPAD (CONTINUED) Example of Entry of Site Name Enter the site name "Penrose No 1 Store". From the Text E...

[Page 86] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Programming Page 6-20 5 July 2001 Issue 2.7 6.4.3.2 TEXT PROGRAMMING WITH A PC F3200 allows the text names for zones, relays, etc, to be entered from a PC using the F3200 printer port. ...

[Page 87] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Programming Issue 2.7 5 July 2001 Page 6-21 TEXT PROGRAMMING WITH A PC (CONTINUED) The DELETE or BACKSPACE keys may be used to delete the last character typed, and the ESCAPE key may be ...

[Page 88] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Programming Page 6-22 5 July 2001 Issue 2.7 TEXT PROGRAMMING WITH A PC (CONTINUED) I0 JEH (three characters) I1 MJS . . I9 BAC F Phone VIGILANT FIRE 7903600 ...

[Page 89] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Programming Issue 2.7 5 July 2001 Page 6-23 GLOBAL DATA (CONTINUED) For V2.07 and later software 1:Auto test; 2:FIP MCP; 3:FFCIF options; 4:All zones isolated; 5:More 3:FFCIF options pro...

[Page 90] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Programming Page 6-24 5 July 2001 Issue 2.7 GLOBAL DATA (CONTINUED) FFCIF options The parameters which can be programmed to configure the FFCIF operation are: FFCIF type The default type...

[Page 91] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Programming Issue 2.7 5 July 2001 Page 6-25 GLOBAL DATA (CONTINUED) Cause Preview, Alarm Type, Acknowledge State, Number of Alarms. and when the "AND." key is pressed, the firs...

[Page 92] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Programming Page 6-26 5 July 2001 Issue 2.7 GLOBAL DATA (CONTINUED) Country Coder (alarm signalling) This is only required for FIPs connected to Brigades with NSW Country Coder equipme...

[Page 93] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Programming Issue 2.7 5 July 2001 Page 6-27 GLOBAL DATA (CONTINUED) Daylight saving start/end This allows the selection of a date and time and a time difference for the start and end o...

[Page 94] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Programming Page 6-28 5 July 2001 Issue 2.7 GLOBAL DATA (CONTINUED) The following table indicates suitable settings: COUNTRY/STATE FORWARD BACKWARD ENABLE D MONTH SUNDA Y HOUR MONTH SU...

[Page 95] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Programming Issue 2.7 5 July 2001 Page 6-29 GLOBAL DATA (CONTINUED) V2.07 or later software • Enablement of Keys in 4 Operating States V2.07 or later software allows each keyboard k...

[Page 96] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Programming Page 6-30 5 July 2001 Issue 2.7 GLOBAL DATA (CONTINUED) Remote Sounder Silence This option is available in V2.07 or later software. Selecting this option shows a menu of: ...

[Page 97] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Programming Issue 2.7 5 July 2001 Page 6-31 GLOBAL DATA (CONTINUED) The parameter “Fault sounder after 8 hrs isolate” enables the fault buzzer to be activated if an isolate state (...

[Page 98] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Programming Page 6-32 5 July 2001 Issue 2.7 The following table lists all of the programmable non-network parameters. The defaults listed are for Australian operation. The previous sec...

[Page 99] Tyco F3200

Document No: LT0122 F3200 Installation & Programming Manual Programming Issue 2.7 5 July 2001 Page 6-33 Item Options Default Bells Isol Key (V2.06 or earlier) Enable/Disable Enabled (V2.06 or earlier) Ancil Isol Key (V2.06 or earlier) Enable/Disa...

[Page 100] Tyco F3200

F3200 Installation & Programming Manual Document No: LT0122 Programming Page 6-34 5 July 2001 Issue 2.7 Item Options Default AZC Time Delay 1 (Std) 1 Std (2.3 Sec) 2 (AVF/RAD) 3 (SAD) 4 (Delay) Delay (4) T1 into Alarm 30 Seconds T2 out of Ala...