Dimplex EF3003 Service Manual

Download or browse on-line these Service Manual for Dimplex EF3003 Fan, Indoor Fireplace.

Dimplex EF3003 Manual Information:

This manual for Dimplex EF3003, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 16 pages, and the size of the file at download is 1.59 Mb. The document type is Service Manual.

Download Manual

More Manuals:

In case you failed to obtain relevant information in this document, please, look through related operating manuals and user instructions for Dimplex EF3003. Just click one of the links below to go to the selected manual:

Summary of Contents:

[Page 1] Dimplex EF3003

Service Manual 30” Insert Model Number: EF3003/SF3003/DF3003 (Canadian and Chinese Built) DFB6016 UL Part Number 6901110159-0559 7400540000R00 In keeping with our policy of continuous product development, we reserve the right to make changes withou...

[Page 2] Dimplex EF3003

2 www.dimplex.com Always use a qualied technician or service agency to repair this replace. ! NOTE: Procedures and techniques that are considered important enough to emphasize. CAUTION: Procedures and techniques whi...

[Page 3] Dimplex EF3003

3 OPERATION - ACUMEN REMOTE (EF3003/SF3003/DF3003 MOD 0-B Units) MANUAL CONTROLS (Figure 1) A. Main On/Off switch The replace has a main ON/OFF switch located on the control panel of the replace. To operate, press the switch once to turn the...

[Page 4] Dimplex EF3003

4 www.dimplex.com MANUAL CONTROLS (Figure 3) A. Main On/Off Switch The replace has a Main On/Off switch located on the control panel of the replace. Toggle the switch to turn the replace On and Off. B. Light Dim...

[Page 5] Dimplex EF3003

5 50 feet (15.25 m). It does not have to be pointed at the replace and can pass through most obstacles (including walls). It is supplied with one of 2,178 independent frequencies to prevent interference with other units. The frequency desig...

[Page 6] Dimplex EF3003

6 www.dimplex.com MAINTENANCE  WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk of re, electric shock or damage to persons. CAUTION: Allow at least ve (5) minutes fo...

[Page 7] Dimplex EF3003

7 EXPLODED PARTS DIAGRAM 3 5 9 10 8 7 13 12 11 1 6 2 4 EF3003 MOD 0-B EF3003 MOD C-E, DFB6016 7 14 15 18 20 21 22 23 24 25 26 16 ...

[Page 8] Dimplex EF3003

8 www.dimplex.com Part Canada China EF3003/ SF3003 Mod 0 EF3003/ SF3003 Mod A EF3003/SF3003/DF3003 DFB6016 Mod 0 Mod A Mod B Mod C Mod D Mod E Mod 0 Mod A Mod B Mod C Mod D 1 Log Set 0438550100RP 2 Grille Assembly 100907015...

[Page 9] Dimplex EF3003

9 WIRING DIAGRAM - CHINESE MADE - 3 STAGE REMOTE CONTROL MOMENTARY SWITCH DC MOT AC MOT SWITCH ROCKER AC/L AC/N HEAT2 N HEAT1 L FAN2 N FAN1 L LOWER UPPER LED POTENTIOMETER MOTOR NEUTRAL LINE LOWER TAB UPPER TAB HEATER 2 CIRC BR HEATER 1 FAN LOWER LI...

[Page 10] Dimplex EF3003

10 www.dimplex.com MAIN ON/OFF SWITCH REPLACEMENT Tools Required: Phillips head Screwdriver Flat Head Screwdriver CAUTION: If the replace was operating prior to ser- vicing allow at least 5 minutes for light bulbs and h...

[Page 11] Dimplex EF3003

11 Remove the retaining screws on the top cover and 4. remove the top, being careful not to damage any of the wiring. Locate the ame speed control potentiometer and 5. control board mounted on the top panel (Figure 10) and disconnect the wires ...

[Page 12] Dimplex EF3003

12 www.dimplex.com WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. Remove the rebox trim by inserting a slotted screw-1. driver and t...

[Page 13] Dimplex EF3003

13 Depress the retainer clips on the rear of the switch and 6. push the switch out of the rear cover. Properly orient the new switch and connect all of the 7. wiring clips and connections. Reassemble in the reverse order.8. HEATER ASSEMBLY REPLACE...

[Page 14] Dimplex EF3003

14 www.dimplex.com With needle nose pliers grasp the power cord strain re-6. lief grommet from inside the rear panel and push while twisting to remove. Pull the power cord out through the hole in the rear 7. cover. Install...

[Page 15] Dimplex EF3003

15 PROBLEM CAUSE SOLUTION General Circuit breaker trips or fuse blows when unit is turned on Short in unit wiring. Trace wiring in unit. Improper circuit current rating Additional appliances may exceed the current rating of the circuit breaker or f...

[Page 16] Dimplex EF3003

16 www.dimplex.com PROBLEM CAUSE SOLUTION Heater Heater is not turning off Improper operation Refer to Operation Section Defective Heater On/Off Switch Replace Heater On/Off Switch Defective Remote Control Receiver Replace Re...