Riello VST 800 Installation And Use Manual

Download or browse on-line these Installation And Use Manual for Riello VST 800 UPS.

Riello VST 800 Manual Information:

This manual for Riello VST 800, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 23 pages, and the size of the file at download is 0.6 Mb. The document type is Installation And Use Manual.

Download Manual

Summary of Contents:

[Page 1] Riello VST 800

...

[Page 2] Riello VST 800

2 INTRODUCTION Congratulations on purchasing a UPS Vision product and welcome to Riello UPS! To use the support service offered by Riello UPS, visit the site www.riello-ups.com Our Company is a specialist in the design, development and ...

[Page 3] Riello VST 800

3 CONTENTS PRESENTATION 4 UPS VIEWS 5 FRONT VIEW 5 REAR VIEW 6 DISPLAY PANEL VIEW 7 INSTALLATION 8 INITIAL CONTENT CHECK 8 INSTALLATION ENVIRONMENT 8 USE 9 CONNECTIONS AND SWITCHING ON FOR THE FIRST TIME 9 SWITC...

[Page 4] Riello VST 800

4 PRESENTATION The VISION series is the ideal solution for high end users who require high security and versatility from their power systems. The VISION is the best protection system available for network devices, servers and conventional s...

[Page 5] Riello VST 800

5 UPS VIEWS FRONT VIEW Display Removable front panel Multipurpose buttons Battery pack connector ON/OFF Switch Battery pack retention panel ...

[Page 6] Riello VST 800

6 REAR VIEW 800VA / 1100VA Model 1500VA / 2000VA Model Communication port RS232 Cooling fans USB communication port IEC 10A output socket Circuit breaker Energyshare Communication Card Slots IEC 1...

[Page 7] Riello VST 800

7 DISPLAY PANEL VIEW “SEL” button (Select) Load level indicator “ON” button Configuration area “STAND-BY” button Maintenance request Regular operation Timer Mains operation Measurement di...

[Page 8] Riello VST 800

8 INSTALLATION INITIAL CONTENT CHECK After opening the packaging, it is first necessary to check the contents. The package must contain: UPS Schuko power cable - IEC 10A 2 IEC 10A connection cables USB cable R...

[Page 9] Riello VST 800

9 USE CONNECTIONS AND SWITCHING ON FOR THE FIRST TIME 1) Confirm that the installation upstream of the UPS is adequately protected against overloads and short circuits. It is recommended that the rating of this protection is either 10A o...

[Page 10] Riello VST 800

10 DISPLAY PANEL MESSAGES This chapter describes, in detail, the various information that can be displayed on the LCD. UPS STATUS MESSAGES ICON STATUS DESCRIPTION Fixed Indicates a fault Flashing The UPS is in stand-by mode ...

[Page 11] Riello VST 800

11 MEASUREMENT DISPLAY AREA The front panel can be used to display important UPS operating information. When the UPS is switched-on, the display shows the main voltage value. To display a different measurement, press the “SEL” button repe...

[Page 12] Riello VST 800

12 CONFIGURING THE OPERATING MODE The area of the display shown in the figure displays the active operating mode and allows the user to choose other modes directly from the display panel. HOW TO PROCEED: • To access the configurati...

[Page 13] Riello VST 800

13 SOFTWARE MONITORING AND CONTROL SOFTWARE The PowerShield 3 software guarantees effective, intuitive UPS management, displaying all the most important information such as input voltage, applied load and battery capacity. It is...

[Page 14] Riello VST 800

14 UPS CONFIGURATION The table below illustrates all the possible configurations available to the user in order to best adapt the UPS for individual requirements. It is possible to perform these operations using the UPStools software. FUN...

[Page 15] Riello VST 800

15 COMMUNICATION PORTS On the back of the UPS (see UPS Views), the following communication ports are present: • RS232 connector • USB connector • Expansion slot for additional communication cards RS232 CONNECTOR RS232 CONNECTO...

[Page 16] Riello VST 800

16 BATTERY PACK REPLACEMENT The UPS is also equipped with a dedicated battery pack that allows for easy replacement of batteries (hot swap) in complete safety, thanks to the protected connection system. • WHEN THE BATTERY PACK IS DI...

[Page 17] Riello VST 800

17 3. Remove the battery pack's retention panel carrying out the operations shown in the figure below. 4. Slip off the battery pack pulling it towards the outside, as shown in the figure below. Be careful when extracting ...

[Page 18] Riello VST 800

18 TROUBLESHOOTING Irregular UPS operation is not always an indication of a fault, and can be due to minor or easy-to-resolve issues It is therefore advisable to consult the table below as it contains information which is useful for solving t...

[Page 19] Riello VST 800

19 PROBLEM POSSIBLE CAUSE SOLUTION THE BUZZER SOUNDS CONTINUOUSLY AND THE DISPLAY SHOWS ONE OF THE FOLLOWING CODES: A54, F50, F51, F52, L50, L51, L52 THE LOAD APPLIED TO THE UPS IS TOO HIGH Reduce the load to within the threshold of...

[Page 20] Riello VST 800

20 ALARM CODES Using a sophisticated self-diagnosis system, the UPS is able to check its own status for any anomalies and/or faults which may occur during normal operation and display them on the display panel. If there is a problem, the UPS...

[Page 21] Riello VST 800

21 ¾ Active commands: Indicates the presence of an active remote command. CODE DESCRIPTION C01 Remote control 1 (Switch On/Off) C02 Remote control 2 (Load supplied by the mains) C03 Remote control 3 (Switch On/Off) C04 Battery test...

[Page 22] Riello VST 800

22 TECHNICAL DATA UPS MODELS VST 800 VST 1100 VST 1500 VST 2000 INPUT Nominal voltage [Vac] 220 - 230 - 240 Maximum operating voltage [Vac] 300 Nominal frequency [Hz] 50 - 60 Rated current (1) [A] 3.9 5.3 7.4 9.7 BATTERY ...

[Page 23] Riello VST 800

0MNVST800RUENUA ...