[Page 1] Runco XP-50DHD

XP-50DHD XP-OPAL50DHD XP-65DHD XP-OPAL65DHD XP-103DHD High Definition, 1080p Flat Panel Plasma Display with and Digital High Definition TM Controller/Scaler/Processor with Vivix III TM Technology TM I NSTALLATION/OPERATION MANUAL ...

[Page 2] Runco XP-50DHD

...

[Page 3] Runco XP-50DHD

PlasmaWall XP Series Installation/Operation Manual iii PRE L IMINAR Y RuncoCare™ Standard Two Year Limited Warranty Congratulations on your purchase of a Runco® product! With proper installation, setup and care, you should enjoy many years of u...

[Page 4] Runco XP-50DHD

iv PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y In the event of a product defect, please follow the warranty claim procedure provided below: 1. The Customer is required to contact a Runco dealer or Runco Technical Support via E-...

[Page 5] Runco XP-50DHD

PlasmaWall XP Series Installation/Operation Manual v PRE L IMINAR Y j Failure to follow maintenance procedures as outlined in the product’s user guide where a schedule is specified for regular cleaning of the product k Opening the product and/or...

[Page 6] Runco XP-50DHD

vi PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y RUNCO’S MAXIMUM AGGREGATE LIABILITY HEREUNDER IS LIMITED TO THE COST OF REPAIR OR REPLACEMENT OF THE PRODUCT. 1. RUNCO SHALL NOT BE LIABLE FOR DAMAGE TO OTHER PROPERTY CAUSED BY...

[Page 7] Runco XP-50DHD

PlasmaWall XP Series Installation/Operation Manual vii PRE L IMINAR Y Thank you for your purchase of this quality Runco product! For best performance, please read this manual carefully as it is your guide through the menus and operation. 1. Read th...

[Page 8] Runco XP-50DHD

viii PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Manufacturer’s Name: Runco International, LLC Manufacturer’s Address: 1195 NW Compton Drive, Beaverton, OR 97006-1992 hereby declares that the products Model Numbers: XP-50D...

[Page 9] Runco XP-50DHD

PlasmaWall XP Series Installation/Operation Manual ix PRE L IMINAR Y NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide r...

[Page 10] Runco XP-50DHD

x PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Notes: ...

[Page 11] Runco XP-50DHD

PlasmaWall XP Series Installation/Operation Manual xi 1Table of Contents PRE L IMINAR Y RuncoCare™ Standard Two Year Limited Warranty ................................................... iii Important Safety Instructions ..............................

[Page 12] Runco XP-50DHD

Table of Contents xii PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Installation Considerations ..........................................................................................17 Special Requirements for the XP-103DHD......

[Page 13] Runco XP-50DHD

Table of Contents PlasmaWall XP Series Installation/Operation Manual xiii PRE L IMINAR Y 6. External Control ......................................................................................................63 Serial Communications ...............

[Page 14] Runco XP-50DHD

Table of Contents xiv PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Notes: ...

[Page 15] Runco XP-50DHD

PlasmaWall XP Series Installation/Operation Manual xv 1List of Figures PRE L IMINAR Y 2-1. PlasmaWall XP-50DHD and XP-OPAL50DHD Front-Panel Controls and Indicators ......5 2-2. PlasmaWall XP-65DHD and XP-OPAL65DHD Front-Panel Controls and Indicators...

[Page 16] Runco XP-50DHD

List of Figures xvi PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y 7-2. PlasmaWall Model XP-65DHD and XP-OPAL65DHD Dimensions (with Optional Table Stand) .......................................................................

[Page 17] Runco XP-50DHD

PlasmaWall XP Series Installation/Operation Manual 1 PRE L IMINAR Y 1.1 About This Manual This Owner’s Manual describes how to install, set up and operate a Runco PlasmaWall XP Series Flat-Panel Plasma Display Monitor and DHD Controller (Model X...

[Page 18] Runco XP-50DHD

Introduction 2 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Graphic Conventions: These symbols appear in numerous places throughout the manual, to emphasize points that you must keep in mind to avoid problems with your equipmen...

[Page 19] Runco XP-50DHD

Introduction PlasmaWall XP Series Installation/Operation Manual 3 PRE L IMINAR Y 1.3 Description, Features and Benefits The PlasmaWall XP Series Flat-Panel Plasma Display Monitor and DHD Controller establish a higher threshold for flat panel disp...

[Page 20] Runco XP-50DHD

Introduction 4 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Parts List Your PlasmaWall is shipped with the following items. If any items are missing or damaged, please contact your Runco dealer or Runco Customer Service at (800...

[Page 21] Runco XP-50DHD

PlasmaWall XP Series Installation/Operation Manual 5 PRE L IMINAR Y 2.1 PlasmaWall at a Glance Controls and IndicatorsFigure 2-1, Figure 2-2 and Figure 2-3 show the PlasmaWall front-panel controls and indicators. Figure 2-1. PlasmaWall XP-50DHD ...

[Page 22] Runco XP-50DHD

Controls and Functions 6 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Figure 2-3. PlasmaWall XP-103DHD Front-Panel Controls and Indicators 1. DISPLAY STAND Optional accessory for table-top installations. 2. POWER BUTTON Connec...

[Page 23] Runco XP-50DHD

Controls and Functions PlasmaWall XP Series Installation/Operation Manual 7 PRE L IMINAR Y ConnectorsFigure 2-4 shows the rear-panel connector locations on the PlasmaWall. Figure 2-4. PlasmaWall Rear Panel SERIALPC IN AUDIO SLOT1 SLOT3 P R /C R ...

[Page 24] Runco XP-50DHD

Controls and Functions 8 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y 1. SLOT 1 Not used. 2. SLOT 2 (Dual HDMI input) Two, HDCP-compliant digital video inputs. Connect the HDMI output from the DHD Controller to input “A”...

[Page 25] Runco XP-50DHD

Controls and Functions PlasmaWall XP Series Installation/Operation Manual 9 PRE L IMINAR Y 5. LEFT BUTTON Used to direct-select inputs or move the menu cursor left in the OSD. When no menu is present on-screen, the LEFT button toggles through the ...

[Page 26] Runco XP-50DHD

Controls and Functions 10 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y 2.3 DHD Controller Rear Panel Figure 2-6 shows the rear connector panel on the DHD Controller. Figure 2-6. DHD Controller Rear Panel Outputs 1. HDMI Out Co...

[Page 27] Runco XP-50DHD

Controls and Functions PlasmaWall XP Series Installation/Operation Manual 11 PRE L IMINAR Y Inputs4. USB A standard, USB Series “B” connection to a personal computer. (For future use.) 5. HDMI 1 / HDMI 2 (Digital) HDCP-compliant digital video ...

[Page 28] Runco XP-50DHD

Controls and Functions 12 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y 2.4 PlasmaWall Remote Control Unit Figure 2-7 shows the PlasmaWall remote control, and the paragraphs that follow describe its functionality. Figure 2-7. ...

[Page 29] Runco XP-50DHD

Controls and Functions PlasmaWall XP Series Installation/Operation Manual 13 PRE L IMINAR Y 1. IR OUTPUT INDICATOR Lights when a button is pressed to indicate that an IR signal is being transmitted. 2. ON / OFF Press to turn the display on or off....

[Page 30] Runco XP-50DHD

Controls and Functions 14 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y 10. Aspect Ratio Selection Buttons Use the red buttons to select an aspect ratio directly or to enter numeric characters, as follows: 16:9 (3) For vi...

[Page 31] Runco XP-50DHD

PlasmaWall XP Series Installation/Operation Manual 15 PRE L IMINAR Y 3.1 Remote Control To install batteries in the remote control: 1. Press down the tab on the cover and pull the cover in the direction of the arrow. 2. Insert the include...

[Page 32] Runco XP-50DHD

Installation 16 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y • Do not drop the remote control or expose it to moisture or high temperature. • The remote control may malfunction under a fluorescent lamp. If that occurs, move t...

[Page 33] Runco XP-50DHD

Installation PlasmaWall XP Series Installation/Operation Manual 17 PRE L IMINAR Y 3.3 Installation Considerations Proper installation of your PlasmaWall will ensure the highest possible picture quality. Whether you are installing the PlasmaWall t...

[Page 34] Runco XP-50DHD

Installation 18 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y You can attach your optional mounts or stand to the PlasmaWall in either of two ways: • While it is upright. • As it lies flat with the sc...

[Page 35] Runco XP-50DHD

Installation PlasmaWall XP Series Installation/Operation Manual 19 PRE L IMINAR Y Figure 3-2. Ventilation Requirements for Enclosure Mounting (XP-50DHD, XP-OPAL50DHD, XP-65DHD and XP-OPAL65DHD) Figure 3-3. Ventilation Requirements for Enclosure Mou...

[Page 36] Runco XP-50DHD

Installation 20 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Audio/Video Synchronization Issues Due to its extraordinarily high level of video processing performance, the DHD Controller may distribute video signals with a percep...

[Page 37] Runco XP-50DHD

Installation PlasmaWall XP Series Installation/Operation Manual 21 PRE L IMINAR Y Other ConsiderationsHere are some other considerations and tips that can help improve your installation, avoid damage and prolong operating life: • Keep the ambien...

[Page 38] Runco XP-50DHD

Installation 22 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y 3.4 Connections to the PlasmaWall and DHD Controller Proceed as follows to connect the PlasmaWall to the DHD Controller, your video sources, external controller(s) ...

[Page 39] Runco XP-50DHD

Installation PlasmaWall XP Series Installation/Operation Manual 23 PRE L IMINAR Y Digital Video Connection: The PlasmaWall has a dual HDMI input board, labeled HDMI (SLOT 2). Connect the HDMI output from the DHD Controller to input “A” on this ...

[Page 40] Runco XP-50DHD

Installation 24 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Connecting Source Components to the DHD Controller Connect your video sources to the DHD Controller as shown and described in the sections that follow. HDMI Source ...

[Page 41] Runco XP-50DHD

Installation PlasmaWall XP Series Installation/Operation Manual 25 PRE L IMINAR Y Component Video Source Connections: Connect your component video sources to the HD1, HD2 and/or Component/SCART inputs as shown in Figure 3-7. Figure 3-7. Component...

[Page 42] Runco XP-50DHD

Installation 26 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y RGBHV Source Connections: Connect personal computers and/or other RGB sources to the HD1, HD2 and/or Component/SCART inputs as shown in Figure 3-8. Figure 3-8. RGBHV...

[Page 43] Runco XP-50DHD

Installation PlasmaWall XP Series Installation/Operation Manual 27 PRE L IMINAR Y SCART RGBS Source Connections: Connect the green, blue and red outputs from your SCART source to the Component/SCART input on the DHD Controller. Connect the sync ou...

[Page 44] Runco XP-50DHD

Installation 28 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Composite and S-Video Source Connections: See Figure 3-10. Figure 3-10. S-Video and Composite Video Source Connections Gaming Console VCR Camcorder Composite S-Video S...

[Page 45] Runco XP-50DHD

Installation PlasmaWall XP Series Installation/Operation Manual 29 PRE L IMINAR Y RS-232 Controller Connection Use a straight-through, 9-pin RS-232 cable to connect a PC or control/automation system (if present) to the RS-232 port on the DHD Contr...

[Page 46] Runco XP-50DHD

Installation 30 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Connecting 12-volt Trigger Outputs to External Equipment If your installation includes equipment that responds to 12-volt triggers, connect it to the 12-volt trigge...

[Page 47] Runco XP-50DHD

Installation PlasmaWall XP Series Installation/Operation Manual 31 PRE L IMINAR Y Connecting an External IR Receiver to the DHD Controller If infrared signals from the remote control cannot reach the DHD Controller due to excessive distance or ob...

[Page 48] Runco XP-50DHD

Installation 32 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Connecting AC Power Plug the female end of the power cord into the AC receptacle on the rear of the PlasmaWall. Connect the other end to your AC power source. (The XP-...

[Page 49] Runco XP-50DHD

PlasmaWall XP Series Installation/Operation Manual 33 PRE L IMINAR Y 4.1 Turning on the Power 1. Turn on your source components. 2. Press the main power switch on the PlasmaWall (see Figure 2-1, Figure 2-2 or Figure 2-3). Its standby/on indicator ...

[Page 50] Runco XP-50DHD

Operation 34 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y 2. Double click on the Display icon. 3. Click the Settings tab on the display dialog box. 4. Set the Screen area to 1024x768 pixels. 5. Click the Ad...

[Page 51] Runco XP-50DHD

Operation PlasmaWall XP Series Installation/Operation Manual 35 PRE L IMINAR Y 4.3 Using the On-Screen Menus To display the Main Menu, press the MENU button on the remote control (Figure 2-5) or DHD Controller front panel (Figure 2-3). To select...

[Page 52] Runco XP-50DHD

Operation 36 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Figure 4-1. PlasmaWall OSD Menu Structure (continued) Main Menu The Main Menu is the starting point for accessing all PlasmaWall functions. (You must enter a passcode to ...

[Page 53] Runco XP-50DHD

Operation PlasmaWall XP Series Installation/Operation Manual 37 PRE L IMINAR Y Input SourceFrom the Main Menu, select Input Source to choose a video signal source. The active source is indicated by an arrow (➡) to its left; in this example, Compo...

[Page 54] Runco XP-50DHD

Operation 38 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Table 4-1. Aspect Ratio Settings Aspect Ratio Remote Control Button Description 16:9 16:9 Select 16:9 to view 16:9 DVDs and HDTV programs in their native aspect ratio....

[Page 55] Runco XP-50DHD

Operation PlasmaWall XP Series Installation/Operation Manual 39 PRE L IMINAR Y Cinema CINEMA Select Cinema to view 2.35:1 source material on a 16:9 screen. The upper and lower portions of the screen are masked, but the geometry of the active im...

[Page 56] Runco XP-50DHD

Operation 40 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Picture Use the controls in the Picture Menu to calibrate your PlasmaWall for optimum picture quality. The PlasmaWall has been designed to incorporate setup and calibrati...

[Page 57] Runco XP-50DHD

Operation PlasmaWall XP Series Installation/Operation Manual 41 PRE L IMINAR Y PLUGE patterns vary but generally consist of some combination of black, white and gray areas against a black background. The example above includes two vertical bars and...

[Page 58] Runco XP-50DHD

Operation 42 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Color Saturation: On your external test pattern source, select a color bar pattern like the one shown in Figure 4-4. Figure 4-4. Typical Color Bar Pattern for Adjusting...

[Page 59] Runco XP-50DHD

Operation PlasmaWall XP Series Installation/Operation Manual 43 PRE L IMINAR Y 11.Adjust the color saturation level until the outermost (gray and blue) color bars appear to be a single shade of blue: Tint: Tint or “hue” is essentially the rati...

[Page 60] Runco XP-50DHD

Operation 44 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust sharpness, select Sharpness from the Picture menu and press ENTER. On your exter...

[Page 61] Runco XP-50DHD

Operation PlasmaWall XP Series Installation/Operation Manual 45 PRE L IMINAR Y Input PositionUse the controls in the Input Position Menu to fine-tune the aspect ratio and image position for the current source. Left/Right: Select Left/Right from the...

[Page 62] Runco XP-50DHD

Operation 46 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Figure 4-6. Overscan Modes Phase (RGB, Component or SCART sources): This control adjusts the phase of the pixel sampling clock relative to the incoming signal. Adjust the...

[Page 63] Runco XP-50DHD

Operation PlasmaWall XP Series Installation/Operation Manual 47 PRE L IMINAR Y Memory Presets For each input, the PlasmaWall lets you save image quality settings as presets that you can recall at a later time. You can create up to four presets per ...

[Page 64] Runco XP-50DHD

Operation 48 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y To reset the Custom 1 or Custom 2/THX memory preset to its factory-default state, select it, press or to highlight Reset and press ENTER. Information Signal / System:...

[Page 65] Runco XP-50DHD

Operation PlasmaWall XP Series Installation/Operation Manual 49 PRE L IMINAR Y CalibrationUse the Calibration menu to perform advanced picture quality adjustments. This menu should be used by ISF-certified technicians only. To recall the ISF Nigh...

[Page 66] Runco XP-50DHD

Operation 50 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y • Color Temp: Select Color Temp from the Display Color menu to adjust the color temperature. Color temperature establishes the “color of gray” by adjusting the 75% ...

[Page 67] Runco XP-50DHD

Operation PlasmaWall XP Series Installation/Operation Manual 51 PRE L IMINAR Y • Black Level: Select Black Level from the Display Color menu to adjust the black level “floor” (lower limit). If blacks appear too gray, set Black Level to a high...

[Page 68] Runco XP-50DHD

Operation 52 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Copy/Paste: You can copy and paste settings from one memory location to another. This gives you a convenient starting point for creating a new preset based on an existing...

[Page 69] Runco XP-50DHD

Operation PlasmaWall XP Series Installation/Operation Manual 53 PRE L IMINAR Y OSD Position: To adjust the position of the OSD, select OSD Position from the Calibration menu and press ENTER. Press or to select “Hor.” or “Ver.” Then, pr...

[Page 70] Runco XP-50DHD

Operation 54 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Remote Control: Select Remote Control from the Service menu to change the following settings related to remote control operation. • Remote Code: Select Remote Code from...

[Page 71] Runco XP-50DHD

Operation PlasmaWall XP Series Installation/Operation Manual 55 PRE L IMINAR Y Color Space: Select Color Space from the Service menu to choose the color space of the source signal for HDMI, RGB, and component connections. • The default setting, A...

[Page 72] Runco XP-50DHD

Operation 56 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y • CUE (Chroma Upsampling Error) Correction: Some DVD players use MPEG decoders that do not correctly “upsample” the 4:2:0 format chroma information on the DVD to t...

[Page 73] Runco XP-50DHD

Operation PlasmaWall XP Series Installation/Operation Manual 57 PRE L IMINAR Y System Reset: To reset ALL controller settings (including image settings) back to their factory defaults, choose System Reset from the Service menu. A confirmation mess...

[Page 74] Runco XP-50DHD

Operation 58 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Notes: ...

[Page 75] Runco XP-50DHD

PlasmaWall XP Series Installation/Operation Manual 59 PRE L IMINAR Y 5.1 Cleaning Regular cleaning will extend the life and performance of the PlasmaWall. Before cleaning, be sure to unplug the power cord from the power outlet. Cleaning the Displa...

[Page 76] Runco XP-50DHD

Maintenance and Troubleshooting 60 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y 5.2 Troubleshooting Tips Table 5-1 provides some general guidelines for troubleshooting problems you may encounter with the PlasmaWall. If the sugg...

[Page 77] Runco XP-50DHD

Maintenance and Troubleshooting PlasmaWall XP Series Installation/Operation Manual 61 PRE L IMINAR Y RGB-HD images appear “noisy.” • Clock and Phase settings need adjustment. • Adjust Clock and Phase settings (refer to Input Color on p...

[Page 78] Runco XP-50DHD

Maintenance and Troubleshooting 62 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Notes: ...

[Page 79] Runco XP-50DHD

PlasmaWall XP Series Installation/Operation Manual 63 PRE L IMINAR Y In addition to using the DHD Controller front-panel keypad or remote control unit, there are two methods of controlling the PlasmaWall and DHD Controller externally: • Using a ...

[Page 80] Runco XP-50DHD

External Control 64 PlasmaWall XP Series Installation/Operation Manual P RELI M INARY Table 6-1 lists the RS-232 command set. The “Parameter (min/max)” column shows the valid parameter ranges, or “NA” for commands that take no parameters. W...

[Page 81] Runco XP-50DHD

External Control PlasmaWall XP Series Installation/Operation Manual 65 PRE L IMINAR Y Aspect Ratio Commands 16:9 NA YES Selects the 16:9 aspect ratio 4:3 NA YES Selects the 4:3 aspect ratio ASPECT? NA NA Returns current aspect ratio CINEMA NA YES Se...

[Page 82] Runco XP-50DHD

External Control 66 PlasmaWall XP Series Installation/Operation Manual P RELI M INARY Image Preset Commands CUSTOM1 NA YES Loads “Custom 1” image preset CUSTOM2 NA YES Loads “Custom 2” (“THX”) image preset DAY NA YES Loads “ISF Day” i...

[Page 83] Runco XP-50DHD

External Control PlasmaWall XP Series Installation/Operation Manual 67 PRE L IMINAR Y Miscellaneous Commands DISPLAY? NA NA Returns display device input source value, as follows: 1 = Auto 22 = XP-50DHD 23 = XP-65DHD 24 = XP-103DHD INRES? NA NA Retu...

[Page 84] Runco XP-50DHD

External Control 68 PlasmaWall XP Series Installation/Operation Manual P RELI M INARY 6.2 Using Discrete IR Codes The DHD Controller accepts commands in the form of IR signals that conform to the Phillips RC5 protocol. Each DHD Controller remote c...

[Page 85] Runco XP-50DHD

External Control PlasmaWall XP Series Installation/Operation Manual 69 PRE L IMINAR Y Figure 6-1 shows the pulse train for this command (with the toggle bit set to zero). Figure 6-1. RC5 Message Format IR Command ListTable 6-2 lists the RC5 control...

[Page 86] Runco XP-50DHD

External Control 70 PlasmaWall XP Series Installation/Operation Manual P RELI M INARY CUST 1 0x3472 0x3C72 Custom 1 memory preset CUST 2 0x3473 0x3C73 Custom 2 memory preset DOWN 0x3446 0x3C46 Down-Arrow ( ) ENTER 0x3444 0x3C44 ENTER EXIT 0x3474 0x3C...

[Page 87] Runco XP-50DHD

PlasmaWall XP Series Installation/Operation Manual 71 PRE L IMINAR Y 7.1 PlasmaWall Specifications Table 7-1 lists the PlasmaWall specifications. 7. Specifications Table 7-1. PlasmaWall Specifications Native Resolution: 1920 x 1080 Screen Size:...

[Page 88] Runco XP-50DHD

Specifications 72 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y 7.2 DHD Controller Specifications Table 7-2 lists the DHD Controller specifications. Table 7-2. DHD Controller Specifications Aspect Ratios: 4:3, Letterbox, 16:...

[Page 89] Runco XP-50DHD

Specifications PlasmaWall XP Series Installation/Operation Manual 73 PRE L IMINAR Y 7.3 PlasmaWall Dimensions Figure 7-1, Figure 7-2 and Figure 7-3 show the PlasmaWall dimensions (all dimensions are in inches). Figure 7-1. PlasmaWall Model XP-5...

[Page 90] Runco XP-50DHD

Specifications 74 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y Figure 7-2. PlasmaWall Model XP-65DHD and XP-OPAL65DHD Dimensions (with Optional Table Stand) 0 7.87 12.37 1.98 2.35 3.69 62.45 54.60 50.10 0 1.63 37.69 1.34 IR R...

[Page 91] Runco XP-50DHD

Specifications PlasmaWall XP Series Installation/Operation Manual 75 PRE L IMINAR Y Figure 7-3. PlasmaWall Model XP-103DHD Dimensions (with Floor Stand) 5.25 34.30 16.00 1.45 6.50 89.38 59.50 96.13 50.75 102.50 42.30 69.40 ...

[Page 92] Runco XP-50DHD

Specifications 76 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y 7.4 Supported Timings Table 7-3 lists the signal types supported by each input on the DHD Controller. Table 7-3. Supported Signal Timings by Input Format Resoluti...

[Page 93] Runco XP-50DHD

Specifications PlasmaWall XP Series Installation/Operation Manual 77 PRE L IMINAR Y 1280x1024 1280x1024 60.00 63.981 108.000 √ √ √ – – – 75.00 79.976 135.000 √ √ √ – – – 85.00 91.146 157.500 √ √ √ – – – 1360x768 1...

[Page 94] Runco XP-50DHD

Specifications 78 PlasmaWall XP Series Installation/Operation Manual PRE L IMINAR Y PAL-M – 59.94/60.00 15.734/15.750 3.580 – – – – √ √ PAL-N – 50.00 15.625 3.580 – – – – √ √ SECAM – 50.00 15.625 13.500 – – – √ �...

[Page 95] Runco XP-50DHD

...

[Page 96] Runco XP-50DHD