Goodman ASAS-10ASC Installation, Operation And Service Instructions

Download or browse on-line these Installation, Operation And Service Instructions for Goodman ASAS-10ASC Air Cleaner.

Goodman ASAS-10ASC Manual Information:

This manual for Goodman ASAS-10ASC, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 12 pages, and the size of the file at download is 0.33 Mb. The document type is Installation, Operation And Service Instructions.

Download Manual

Summary of Contents:

[Page 1] Goodman ASAS-10ASC

INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS MODELS ASAS-10ASC, ASAS-11ASC, ASAS-12ASC, ASAS-18ASC GSAS-10ASC, GSAS-11ASC, GSAS-12ASC, GSAS-18ASC ELECTRONIC AIR CLEANERS IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT ...

[Page 2] Goodman ASAS-10ASC

CONTENTS SAFETY CONSIDERATIONS 2 WHAT THE ELECTRONIC AIR CLEANER DOES 2 BENEFITS 2 HOW IT WORKS ...

[Page 3] Goodman ASAS-10ASC

1 Dirty Air 2 Prefilter 3 Ionizing Section COMPONENTS Cabinet: Constructed of heavy gauge galvanized steel to resist corrosion and provide trouble-free installation. Holes are provided to facilitate moun...

[Page 4] Goodman ASAS-10ASC

UNIT A B C D E F G H ASAS-10ASC GSAS-10ASC 21 (53.0) 17 (43.5) 23 1/4 (59.0) 13 1/8 (33.5) 20 3/4 (53.0) 1 1/4 (3.0) 23 3/4 (60.5) 2 3/8 (6.0) ASAS-11ASC GSAS-11ASC 21 (53.0) 17 (43.5) 26 (66.0) 13 5/8 (34.5) 24...

[Page 5] Goodman ASAS-10ASC

Wiring Wiring should only be performed by qualified personnel only. All wiring must comply with all applicable codes and standards. The voltage of the power source must match the voltage indicated on the Air Cleaner. The Air Cleaner should opera...

[Page 6] Goodman ASAS-10ASC

efficiency. The frequency of cleaning will vary from one house to another. On average, the cells should be cleaned every 3 months. 1. Remove access door, collecting cells and prefilters. 2. Place cells in a laundry tub. Rinse with hot water an...

[Page 7] Goodman ASAS-10ASC

Replacing An Air Proving Switch (APS) Before replacing the APS, turn off the power to the Air Cleaner at the source. 1. Disconnect wiring from terminals 1, 2, 3, and 4 on the APS. See Fig. 5 and 6. 2. Release circuit board from plastic spacer...

[Page 8] Goodman ASAS-10ASC

Replacing The 24 V Transformer (A/ GSAS-12 and A/ GSAS-18 only) Before replacing 24 V transformer, turn off power to the Air Cleaner at the source. 1. Remove power box cover. 2. Disconnect the secondary leads from the transformer to the 24 V t...

[Page 9] Goodman ASAS-10ASC

Testing Voltage At Cell 1. Open access door to Air Cleaner. Air Cleaner will shut off. 2. Insert a thin shafted screwdriver 2 to 3 inches into the hole in the round end plate insulator. See Fig. 9. 3. Attach the ground of the high voltage me...

[Page 10] Goodman ASAS-10ASC

Replacing A Tungsten Ionizing Wire Replacement wires are cut to the correct length and have eyelets at each end for easy replacement. 1. Turn OFF power to Air Cleaner. 2. Remove cell from Air Cleaner. 3. Remove all parts of broken wire, as we...

[Page 11] Goodman ASAS-10ASC

PROBLEM PROBABLE CAUSE REMEDY System fan is not on. Turn system fan on. Wiring improperly connected. Check wiring. Defective power switch. Check power switch for continuity with multimeter. Replace if defective. Defective safety inte...

[Page 12] Goodman ASAS-10ASC

GOODMAN MANUFACTURING COMPANY, L.P. 2550 North Loop West, Suite 400, Houston, Texas 77092 FOR MORE INFORMATION, CALL THE AIR CLEANER HOTLINE TOLL FREE 1-800-267-8305 nngoodea.pub 02/08 ELECTRONIC AIR CLEANER LIMITED FIVE (5) YEAR WARRANTY ...