Paradyne 3800Plus Quick Reference

Download or browse on-line these Quick Reference for Paradyne 3800PLUS Modem, Speakers.

Paradyne 3800PLUS Manual Information:

This manual for Paradyne 3800PLUS, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 28 pages, and the size of the file at download is 0.15 Mb. The document type is Quick Reference.

Download Manual

More Manuals:

In case you failed to obtain relevant information in this document, please, look through related operating manuals and user instructions for Paradyne 3800PLUS. Just click one of the links below to go to the selected manual:

Summary of Contents:

[Page 1] Paradyne 3800PLUS

COMSPHERE  3800Plus SERIES MODEMS MODELS 3810Plus and 3811Plus QUICK REFERENCE Document No. 3980-A2-GL10-10 ...

[Page 2] Paradyne 3800PLUS

Copyright E 2002 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval sys...

[Page 3] Paradyne 3800PLUS

1 COMSPHERE 3800Plus Series Modems Models 3810Plus and 3811Plus Quick Reference Document Number 3980-A2-GL10-10 February 2002 Product Documentation on the World Wide Web Complete documentation for this product is available at www.paradyne.com. Sele...

[Page 4] Paradyne 3800PLUS

2 Model 3810Plus Installation DTE Connection Use the following procedure to connect the RS-232D cable from the modem to the DTE: 1. Make sure the modem’s rear panel power switch is Off. 2. Connect the DB-25-P (male) connector on the cable to the D...

[Page 5] Paradyne 3800PLUS

3 Dial-Line Connection Use the following procedure to connect the 3810Plus modem to the dial network interface: 1. Insert the 6-position, 4-conductor modular plug into the jack labeled DIAL/LEASED. 2. Insert the other end of the modular cord into th...

[Page 6] Paradyne 3800PLUS

4 Network Management System Connection For the 3810Plus modem, use the following procedure to connect the modem to the network management system interface: 1. Insert the subminiature 4-position, 4-conductor modular plug of the 3600 Hubbing Device in...

[Page 7] Paradyne 3800PLUS

5 Model 3811Plus Installation The COMSPHERE 3000 Series Carrier has 17 slots which can hold up to 16 modems and one SDU. The SDU is required when the modems in the carrier are controlled by an NMS, or when multiple carriers in a cabinet configuratio...

[Page 8] Paradyne 3800PLUS

6 495-14797 2. At the front of the carrier, hold the modem vertically, with the latch on its faceplate in the open position, and insert it into the top and bottom card guides of one of the slots numbered 1–16. Slide the modem into the slot, aligni...

[Page 9] Paradyne 3800PLUS

7 Circuit Card Guides Circuit Pack Lock Latch Open (Unlocked) Closed (Locked) 495-14813 4. If the carrier is connected to power, the Power LED on the faceplate of the 3811Plus lights up. After several seconds the modem completes its power-up self-te...

[Page 10] Paradyne 3800PLUS

8 Diagnostic Control Panel The Diagnostic Control Panel (DCP) is the user interface to the modem. It provides a 2-line, 32-character liquid crystal display (LCD), a keypad, speaker grill, and status indicators. A Shared DCP (SDCP) is used to manage ...

[Page 11] Paradyne 3800PLUS

9 Checking the SDCP If an SDCP is installed, verify that the SDCP can be used to control the 3811Plus modem. Perform the following steps. Select SDU1 2 3 4 5 6 7 8 9 10111213141516 COMSPHERE 3000 Select Key Status Indicators Carrier Slots 1–16 F1...

[Page 12] Paradyne 3800PLUS

10 3800Plus Modems Menu Tree Call_Setup Status Test “Status” Dial Disconnect Answer Dial_Standby or Return_to_Dial Change_Directory Directory Locations 1 – 10 Abort Self Loc_Analog_Loop Rem_Digital_Loop Loc_Digital_Loop Pattern DTE_Interface A...

[Page 13] Paradyne 3800PLUS

11 Configure Ld EditArea frm: Edit Save Choose Function Active (Saved) Customer1 Customer2 V42/MNP/Buffer Err Contrl Mode Sync Comp Mode SDC Negotiation SDC Idle Fill SDC BitEncoding SyncDTE CRC SDC Delay Min Sync Flow Cntrl V42bis Compress MNP5 Com...

[Page 14] Paradyne 3800PLUS

12 Control Remote Speaker Reset Make_Busy or RemoveMakeBusy Service_Line or DiscServLine Download Code Secondary Prim (data blckd) (ExitRem appears instead of Remote when using Remote Mode) Does not appear in Remote Mode. Security Set_Access_Ctrl (A...

[Page 15] Paradyne 3800PLUS

13 Configuration Option Procedures — DCP Commands 1. Move to the Configure branch and select a configuration area to load from: Active (Operating), Active (Saved), Customer 1, Customer 2, or Factory (Async Dial, Sync Dial, Sync Leased, or UNIX Di...

[Page 16] Paradyne 3800PLUS

14 Configuration Option Procedures — AT Commands Loading Factory Configurations Use the AT&Fy&Wn command to load a factory configuration to either the Active (Saved), Customer 1, or Customer 2 configuration area. Type: AT&Fy&Wn whe...

[Page 17] Paradyne 3800PLUS

15 AT COMMANDS Bold text indicates Async Dial factory defaults. AT Attention Command Prefix/Autobaud Rate. Indicates a command string has started and determines the DTE’s data rate and parity. A/ Repeat Last Command. Reexecutes last command strin...

[Page 18] Paradyne 3800PLUS

16 AT COMMANDS (continued) Yn Long Space Disconnect Y0 Disable. Y1 Enable. Zn Reset and Load Active Z0 Loads contents of Active (Saved) into Active (Operating). Z1 Loads contents of Customer 1 into Active (Operating). Z2 Loads contents of Customer 2...

[Page 19] Paradyne 3800PLUS

17 AT COMMANDS (continued) &M232, &Q232 Modem operates in Async mode; V.25bis Async dialing is enabled. &M233, &Q233 Modem operates in Sync mode; V.25 Bisync dialing is enabled. &M234, &Q234 Modem operates in Sync mode;...

[Page 20] Paradyne 3800PLUS

18 AT COMMANDS (continued) \Dn CTS Control \D0 Forced On. CTS is forced ON. \D1 Standard RS232 operation. \D2 Wink When Disc. CTS turns Off for approximately 1 to 2 seconds upon disconnecting. \D3 Follows DTR. The state of CTS follows the state of D...

[Page 21] Paradyne 3800PLUS

19 RESULT CODES Numbers(1) Numbers(2) Words 0 0 OK 1 1 CONNECT 2 2 RING 3 3 NO CARRIER 4 4 ERROR Result Codes 5–14, 16, 19 are enabled with the X1, X2, X3, and X4 commands. 5 5 CONNECT 1200 6 6 NO DIALT...

[Page 22] Paradyne 3800PLUS

20 S-REGISTERS Register Description Factory Setting Range S0 Auto-Answer Ring Number 1 0(Disable) or 1–255 rings S2 AT Escape Character 43(+) 0–127 ASCII S3 Carriage Return Character 13 0–127 ASCII S4 Line Feed Character 10 0–127 ASC...

[Page 23] Paradyne 3800PLUS

21 S-REGISTERS (continued) Register Description Factory Setting Range S43 Train Time 0 0=Long; 1=Short S44 Leased-Line Rate 27 1=14400(V.32bis); 2=12000(V.32bis); 3=9600(V.32bis); 4=7200(V.32bis); 5=4800(V.32bis); 6=2400(V22bis); 18=19200(V.32terbo)...

[Page 24] Paradyne 3800PLUS

22 S-REGISTERS (continued) Register Description Factory Setting Range S77 DTR Alarm Reporting 0 0=Disable; 1=Enable S78 Dial Automode 0 0=Enable; 1=Disable; 2=System85 S80 No Data Disc Trigger Signal 3 0=RX or TX; 1=TX; 2=RX; 3=TX and RX S82 Leased ...

[Page 25] Paradyne 3800PLUS

23 Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product ...

[Page 26] Paradyne 3800PLUS

24 Notices ! WARNING: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN...

[Page 27] Paradyne 3800PLUS

25 3. The Ringer Equivalence (REN) is used to determine the quantity of devices which may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but no...

[Page 28] Paradyne 3800PLUS

26 10. An FCC compliant telephone cord with modular plugs may be provided with this equipment. This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack which is Part 68 compliant. Canada ...