[Page 1] HP StorageWorks MSA 2/8 - SAN Switch

reference guide hp StorageWorks fabric OS version 3.1.x/4.1.x Product Version: 3.1.x and 4.1.x Third Edition (June 2003) Part Number: AA–RS24C–TE This reference guide provides a detailed description of the Fabric OS commands. Although this gu...

[Page 2] HP StorageWorks MSA 2/8 - SAN Switch

© Copyright 1999-2003 Hewlett-Packard Development Company, L.P. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particula...

[Page 3] HP StorageWorks MSA 2/8 - SAN Switch

3Fabric OS Version 3.1.x/4.1.x Reference Guide contents Contents About this Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

[Page 4] HP StorageWorks MSA 2/8 - SAN Switch

Contents 4 Fabric OS Version 3.1.x/4.1.x Reference Guide bcastShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 bladeBeacon . . . . . . . . . . . . . . . . . . . . ...

[Page 5] HP StorageWorks MSA 2/8 - SAN Switch

Contents 5Fabric OS Version 3.1.x/4.1.x Reference Guide diagClearError . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 diagCommandShow . . . . . . . . . . . . . . . . . . . ....

[Page 6] HP StorageWorks MSA 2/8 - SAN Switch

Contents 6 Fabric OS Version 3.1.x/4.1.x Reference Guide fanDisable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256 fanEnable . . . . . . . . . . . . . . . . . . . . . ...

[Page 7] HP StorageWorks MSA 2/8 - SAN Switch

Contents 7Fabric OS Version 3.1.x/4.1.x Reference Guide hadump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344 haEnable . . . . . . . . . . . . . . . . . . . . . ....

[Page 8] HP StorageWorks MSA 2/8 - SAN Switch

Contents 8 Fabric OS Version 3.1.x/4.1.x Reference Guide msPlatShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 432 msPlClearDB . . . . . . . . . . . . . . . . . . . . ....

[Page 9] HP StorageWorks MSA 2/8 - SAN Switch

Contents 9Fabric OS Version 3.1.x/4.1.x Reference Guide perfShowEEMonitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 515 perfShowFilterMonitor. . . . . . . . . . . . . . . . . . . . ....

[Page 10] HP StorageWorks MSA 2/8 - SAN Switch

Contents 10 Fabric OS Version 3.1.x/4.1.x Reference Guide portStatsShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 609 portswap . . . . . . . . . . . . . . . . . . . . . . ....

[Page 11] HP StorageWorks MSA 2/8 - SAN Switch

Contents 11Fabric OS Version 3.1.x/4.1.x Reference Guide secmodeenable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 691 secmodeshow . . . . . . . . . . . . . . . . . . . . . . ...

[Page 12] HP StorageWorks MSA 2/8 - SAN Switch

Contents 12 Fabric OS Version 3.1.x/4.1.x Reference Guide stopporttest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 792 supportShow . . . . . . . . . . . . . . . . . . . ...

[Page 13] HP StorageWorks MSA 2/8 - SAN Switch

Contents 13Fabric OS Version 3.1.x/4.1.x Reference Guide uRouteRemove . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 877 uRouteShow . . . . . . . . . . . . . . . . . . . . . . . ...

[Page 14] HP StorageWorks MSA 2/8 - SAN Switch

Contents 14 Fabric OS Version 3.1.x/4.1.x Reference Guide Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .945 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

[Page 15] HP StorageWorks MSA 2/8 - SAN Switch

15Fabric OS Version 3.1.x/4.1.x Reference Guide about this guide About this Guide About this Guide This reference guide provides information to help you: ■ Understand and use Fabric OS commands ■ Manage a switch or fabric ■ Contact technical s...

[Page 16] HP StorageWorks MSA 2/8 - SAN Switch

About this Guide 16 Fabric OS Version 3.1.x/4.1.x Reference Guide Overview This section covers the following topics: ■ Intended Audience ■ Related Documentation Intended Audience This book is intended for use by administrators who are experienced...

[Page 17] HP StorageWorks MSA 2/8 - SAN Switch

About this Guide Fabric OS Version 3.1.x/4.1.x Reference Guide 17 Conventions Conventions consist of the following: ■ Document Conventions ■ Text Symbols Document Conventions The document conventions included in Table 1 apply in most cases. Text ...

[Page 18] HP StorageWorks MSA 2/8 - SAN Switch

About this Guide 18 Fabric OS Version 3.1.x/4.1.x Reference Guide Note: Text set off in this manner presents commentary, sidelights, or interesting points of information. ...

[Page 19] HP StorageWorks MSA 2/8 - SAN Switch

About this Guide Fabric OS Version 3.1.x/4.1.x Reference Guide 19 Getting Help If you still have a question after reading this guide, contact an HP authorized service provider or access our website: http://www.hp.com . HP Technical Support Telephon...

[Page 20] HP StorageWorks MSA 2/8 - SAN Switch

About this Guide 20 Fabric OS Version 3.1.x/4.1.x Reference Guide HP Authorized Reseller For the name of your nearest HP authorized reseller: ■ In the United States, call 1-800-345-1518 ■ In Canada, call 1-800-263-5868 ■ Elsewhere, see the HP w...

[Page 21] HP StorageWorks MSA 2/8 - SAN Switch

21Fabric OS Version 3.1.x/4.1.x Reference Guide 1 Fabric OS Commands This chapter lists the Fabric OS commands. It also shows their syntax and operands, and provides examples of their usage. ...

[Page 22] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 22 Fabric OS Version 3.1.x/4.1.x Reference Guide Reset the SNMP agent configuration to default values. Synopsis agtcfgDefault Availability AdminAdmin Release V3.1.x and V4.1.x Description Use this command to reset the configuration...

[Page 23] HP StorageWorks MSA 2/8 - SAN Switch

agtcfgDefault 23Fabric OS Version 3.1.x/4.1.x Reference Guide There are six communities and respective trap recipients supported by the agent. The first three communities are for read-write access (rw) and the last three are for read-only access (r...

[Page 24] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 24 Fabric OS Version 3.1.x/4.1.x Reference Guide There are six Access Control Lists (ACLs) to restrict SNMP get/set/trap operations to hosts under a host-subnet-area. Host-subnet-area is defined by comparing non-zero IP octets. F...

[Page 25] HP StorageWorks MSA 2/8 - SAN Switch

agtcfgDefault 25Fabric OS Version 3.1.x/4.1.x Reference Guide See Also agtcfgSet agtcfgShow SNMPv1 community and trap recipient configuration: Community 1: Secret C0de (rw) Trap recipient: 192.168.15.41 Community 2: OrigEquipMfr (rw) No t...

[Page 26] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 26 Fabric OS Version 3.1.x/4.1.x Reference Guide Modify the SNMP agent configuration. Synopsis agtcfgSet Availability Admin Release V3.1.x and V4.1.x Description Use this command to modify the configuration of the SNMP agent in the...

[Page 27] HP StorageWorks MSA 2/8 - SAN Switch

agtcfgSet 27Fabric OS Version 3.1.x/4.1.x Reference Guide There are six communities and respective trap recipients supported by the agent. The first three communities are for read-write access (rw) and the last three are for read-only access (ro). ...

[Page 28] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 28 Fabric OS Version 3.1.x/4.1.x Reference Guide ACL entries also have a flag to set each host-subnet-area to be read-write or read-only. Highest privilege matched out of six entries is given to the access. An ACL check is turned...

[Page 29] HP StorageWorks MSA 2/8 - SAN Switch

agtcfgSet 29Fabric OS Version 3.1.x/4.1.x Reference Guide Example To modify the SNMP configuration values in V3.1.x: switch:admin> agtcfgSet Customizing MIB-II system variables ... At each prompt, do one of the following: o <Return> to acc...

[Page 30] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 30 Fabric OS Version 3.1.x/4.1.x Reference Guide To modify the SNMP configuration values in V4.1.x: switch:admin> agtcfgSet Customizing MIB-II system variables ... At each prompt, do one of the following: o <Return> to a...

[Page 31] HP StorageWorks MSA 2/8 - SAN Switch

agtcfgSet 31Fabric OS Version 3.1.x/4.1.x Reference Guide See Also agtcfgDefault agtcfgShow authTraps = 0 (OFF) SNMPv1 community and trap recipient configuration: Community 1: Secret C0de (rw) Trap recipient: 192.168.15.41 Community 2: OrigEquipMfr (...

[Page 32] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 32 Fabric OS Version 3.1.x/4.1.x Reference Guide Displays the SNMP agent configuration. Synopsis agtcfgShow Availability All users. Release V3.1.x and V4.1.x Description Use this command to display the configuration of the SNMP age...

[Page 33] HP StorageWorks MSA 2/8 - SAN Switch

agtcfgShow 33Fabric OS Version 3.1.x/4.1.x Reference Guide There are six communities and respective trap recipients supported by the agent. The first three communities are for read-write access (rw) and the last three are for read-only access (ro)....

[Page 34] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 34 Fabric OS Version 3.1.x/4.1.x Reference Guide There are six ACL (Access Control List) to restrict SNMP get/set operations to hosts under a host-subnet-area. Host-subnet-area is defined by comparing non-zero IP octets. For exam...

[Page 35] HP StorageWorks MSA 2/8 - SAN Switch

agtcfgShow 35Fabric OS Version 3.1.x/4.1.x Reference Guide Example To display SNMP agent configuration information: See Also agtcfgDefault agtcfgSet switch:admin> agtcfgShow Current SNMP Agent Configuration Customizable MIB-II system variables...

[Page 36] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 36 Fabric OS Version 3.1.x/4.1.x Reference Guide Delete a port from all local groups. Synopsis aliasDelete portID Availability Admin Release V4.1.x Description Use this command to delete a local port from all local alias groups. A ...

[Page 37] HP StorageWorks MSA 2/8 - SAN Switch

aliasDelete 37Fabric OS Version 3.1.x/4.1.x Reference Guide Exit Status See Also aliasJoin aliasShow fabricShow switchShow 0 Indicates successful operation. Non Zero Indicates that the operation has failed. ...

[Page 38] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 38 Fabric OS Version 3.1.x/4.1.x Reference Guide Create or add a member to a group of N_Ports. Synopsis aliasJoin Availability Admin Release V4.1.x Description Use this command to create an alias group of N_Ports or to add N_Ports...

[Page 39] HP StorageWorks MSA 2/8 - SAN Switch

aliasJoin 39Fabric OS Version 3.1.x/4.1.x Reference Guide Example To create an alias group of N_Ports or to add N_Ports to an existing group enter the following command. Exit Status See Also aliasShow fabricShow nsShow nsAllShow aliasDelete aliasPur...

[Page 40] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 40 Fabric OS Version 3.1.x/4.1.x Reference Guide Remove an alias group. Synopsis aliasPurge groupID Availability Admin Release V4.1.x Description Use this command to remove an alias group. The alias group must be identified by its...

[Page 41] HP StorageWorks MSA 2/8 - SAN Switch

aliasPurge 41Fabric OS Version 3.1.x/4.1.x Reference Guide See Also aliasJoin aliasShow fabricShow switchShow ...

[Page 42] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 42 Fabric OS Version 3.1.x/4.1.x Reference Guide Displays local alias server information. Synopsis aliasShow Availability All users. Release V3.1.x and V4.1.x Description Use this command to display local alias server information. ...

[Page 43] HP StorageWorks MSA 2/8 - SAN Switch

aliasShow 43Fabric OS Version 3.1.x/4.1.x Reference Guide Operands None. Example The following example is for V3.1.x: The following example is for V4.1.x: Exit Status See Also fabricShow switchShow switch:admin> aliasShow The Local Alias Server ha...

[Page 44] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 44 Fabric OS Version 3.1.x/4.1.x Reference Guide Add a member to a zone alias. Synopsis aliAdd “aliName”,”member;member” Availability Admin Release V3.1.x and V4.1.x Description Use this command to add one or more members t...

[Page 45] HP StorageWorks MSA 2/8 - SAN Switch

aliAdd 45Fabric OS Version 3.1.x/4.1.x Reference Guide Operands This command has the following operands: Example To add members to the following aliases: See Also aliCreate aliDelete aliRemove aliShow aliName Specify the name of a zone alias in quota...

[Page 46] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 46 Fabric OS Version 3.1.x/4.1.x Reference Guide Create a zone alias. Synopsis aliCreate “aliName”,”member;member” Availability Admin Release V3.1.x and V4.1.x Description Use this command to create a new zone alias. The zo...

[Page 47] HP StorageWorks MSA 2/8 - SAN Switch

aliCreate 47Fabric OS Version 3.1.x/4.1.x Reference Guide Operands This command has the following operands: Example To create zone aliases in V3.1.x: The following example shows how to create zone aliases in V4.1.x. Notice that the first example us...

[Page 48] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 48 Fabric OS Version 3.1.x/4.1.x Reference Guide See Also aliAdd aliDelete aliRemove aliShow ...

[Page 49] HP StorageWorks MSA 2/8 - SAN Switch

aliDelete 49Fabric OS Version 3.1.x/4.1.x Reference Guide Delete a zone alias. Synopsis aliDelete “aliName” Availability Admin Release V3.1.x and V4.1.x Description Use this command to delete a zone alias. This command changes the Defined Config...

[Page 50] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 50 Fabric OS Version 3.1.x/4.1.x Reference Guide Example To delete the zone alias array2: See Also aliAdd aliCreate aliRemove aliShow switch:admin> aliDelete “array2"“ ...

[Page 51] HP StorageWorks MSA 2/8 - SAN Switch

aliRemove 51Fabric OS Version 3.1.x/4.1.x Reference Guide Remove a member from a zone alias. Synopsis aliRemove “aliName”,”member;member” Availability Admin Release V3.1.x and V4.1.x Description Use this command to remove one or more members ...

[Page 52] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 52 Fabric OS Version 3.1.x/4.1.x Reference Guide Operands This command has the following operands: Example To remove a World Wide Name from “array1”: See Also aliAdd aliCreate aliDelete aliShow aliName Specify the name of the ...

[Page 53] HP StorageWorks MSA 2/8 - SAN Switch

aliShow 53Fabric OS Version 3.1.x/4.1.x Reference Guide Displays zone alias information. Synopsis aliShow “pattern” Availability All users. Release V3.1.x and V4.1.x Description Use this command to display zone configuration information. If a par...

[Page 54] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 54 Fabric OS Version 3.1.x/4.1.x Reference Guide Operands This command has the following operands: If no parameters are specified, all zone configuration information (both defined and effective) is displayed. See cfgShow for a des...

[Page 55] HP StorageWorks MSA 2/8 - SAN Switch

backplanetest 55Fabric OS Version 3.1.x/4.1.x Reference Guide Backplane connection test for multiple blade configured system. Synopsis backplanetest [-slot number][-passcnt count][-payload value][-pat type][-ports list][-verbose mode] Availability A...

[Page 56] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 56 Fabric OS Version 3.1.x/4.1.x Reference Guide -payload value Specify the byte size of the test frame payload. The payload size must be in multiples of 4 and the minimum size is 16. The default value is 512 bytes. This operand ...

[Page 57] HP StorageWorks MSA 2/8 - SAN Switch

backplanetest 57Fabric OS Version 3.1.x/4.1.x Reference Guide Examples Test backplane connections on a StorageWorks Core switch: Errors When this command detects failures, the subtest may report one or more of the following error messages: DATA TIME...

[Page 58] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 58 Fabric OS Version 3.1.x/4.1.x Reference Guide Test for back-end miniswitch to miniswitch links. Synopsis backport [-nframes num][-ports list][-lb_mode mode] [-fr_type type][-extonly enable] Availability Admin Release V4.1.x Des...

[Page 59] HP StorageWorks MSA 2/8 - SAN Switch

backPort 59Fabric OS Version 3.1.x/4.1.x Reference Guide ■ ASIC errors along each path. The test will check for CRC and ENC errors for each port used between the source and destination ports to help isolate failures. It will also check that each ...

[Page 60] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 60 Fabric OS Version 3.1.x/4.1.x Reference Guide Example To test for back-end miniswitch to miniswitch links: Errors When the command detects failures, the test may report one or more of the following error messages: 0x3a INIT 0x2...

[Page 61] HP StorageWorks MSA 2/8 - SAN Switch

backPort 61Fabric OS Version 3.1.x/4.1.x Reference Guide See Also crossporttest portloopbacktest spinsilk spinfab ...

[Page 62] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 62 Fabric OS Version 3.1.x/4.1.x Reference Guide Set an alternate backspace character. Synopsis backSpace [mode] Availability All users (display). Admin (modify). Release V3.1.x Description This command changes the backspace charac...

[Page 63] HP StorageWorks MSA 2/8 - SAN Switch

bannerset 63Fabric OS Version 3.1.x/4.1.x Reference Guide Set the banner on the local switch. Synopsis bannerset [banner] Availability Admin Release V3.1.x and V4.1.x Description Use this command to set the banner on the local switch. The banner is a...

[Page 64] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 64 Fabric OS Version 3.1.x/4.1.x Reference Guide Examples To set a new banner for a switch: See Also bannershow switch:admin> bannerset “my banner” Please input context of security banner (press “.” RETURN at the beginni...

[Page 65] HP StorageWorks MSA 2/8 - SAN Switch

bannershow 65Fabric OS Version 3.1.x/4.1.x Reference Guide Displays the banner text. Synopsis bannershow Availability Admin Release V3.1.x and V4.1.x Description Use this command to display the contents of the banner. Operands None. Examples To displ...

[Page 66] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 66 Fabric OS Version 3.1.x/4.1.x Reference Guide Displays broadcast routing information. Synopsis bcastShow Availability All users. Release V3.1.x and V4.1.x Description Use this command to display the broadcast routing information...

[Page 67] HP StorageWorks MSA 2/8 - SAN Switch

bcastShow 67Fabric OS Version 3.1.x/4.1.x Reference Guide Note: The output from this command varies depending on switch type. Operands None. Examples To display the broadcast routing information for all ports in the switch: See Also mcastShow portRo...

[Page 68] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 68 Fabric OS Version 3.1.x/4.1.x Reference Guide Set blade beaconing mode on or off. Synopsis bladeBeacon [slotnumber] mode Availability Admin Release V4.1.x Description Use this command to set the blade beaconing mode on or off. S...

[Page 69] HP StorageWorks MSA 2/8 - SAN Switch

bladeBeacon 69Fabric OS Version 3.1.x/4.1.x Reference Guide Operands This command has the following operands: Example To turn the blade in slot 2 beaconing mode ON and then OFF: See Also switchShow slotnumber Specify the slot number on which to enab...

[Page 70] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 70 Fabric OS Version 3.1.x/4.1.x Reference Guide Run diagnostics on a switch blade. Synopsis bladediag [[--slot] slotno][-log logfile] Availability Admin Release V4.1.x Description Use this command to run a suite of diagnostics tes...

[Page 71] HP StorageWorks MSA 2/8 - SAN Switch

bladeDiag 71Fabric OS Version 3.1.x/4.1.x Reference Guide Note: To run this command, you must disable the entire switch with the switchdisable command. Compared to bladediagshort, this is a comprehensive test for blade functionality which also inv...

[Page 72] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 72 Fabric OS Version 3.1.x/4.1.x Reference Guide To run a suite of diagnostics: See Also backport bladediagshort camtest centralmemorytest cmitest crossporttest diagshow filtertest portloopbacktest portregtest spinsilk statstest t...

[Page 73] HP StorageWorks MSA 2/8 - SAN Switch

bladeDiagShort 73Fabric OS Version 3.1.x/4.1.x Reference Guide Run diagnostics on a switch blade. Synopsis bladediagshort [[--slot] slotno][-log logfile] Availability Admin Release V4.1.x Description Use this command to run a suite of diagnostics tes...

[Page 74] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 74 Fabric OS Version 3.1.x/4.1.x Reference Guide Note: To run this command, you must disable the entire switch with the switchdisable command. Compared to bladediag, this is a limited test for single blade functionality, which d...

[Page 75] HP StorageWorks MSA 2/8 - SAN Switch

bladeDiagShort 75Fabric OS Version 3.1.x/4.1.x Reference Guide Example To run a suite of diagnostics on blade 1: To run a suite of diagnostics on blade 1: switch:admin> bladediagshort --slot 1 Testing slot: 1, user ports: 0 1 2 3 4 5 6 7 8 9 10 .....

[Page 76] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 76 Fabric OS Version 3.1.x/4.1.x Reference Guide See Also backport bladediag camtest centralmemorytest cmitest crossporttest diagshow filtertest portloopbacktest portregtest spinsilk statstest txdpath ...

[Page 77] HP StorageWorks MSA 2/8 - SAN Switch

bladedisable 77Fabric OS Version 3.1.x/4.1.x Reference Guide Disable a blade. Synopsis bladedisable [slotnumber] Availability Admin Release V4.1.x Description Use this command to disable a blade. All Fibre Channel ports are taken offline. If the swi...

[Page 78] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 78 Fabric OS Version 3.1.x/4.1.x Reference Guide Example Disable a blade in slot 2: See Also switchshow bladeenable portdisable protenable switch:admin> bladedisable 2 ...

[Page 79] HP StorageWorks MSA 2/8 - SAN Switch

bladeenable 79Fabric OS Version 3.1.x/4.1.x Reference Guide Enable a blade. Synopsis bladeenable [slotnumber] Availability Admin Release V4.1.x Description Use this command to enable a blade. All Fibre Channel ports within the blade which did not fa...

[Page 80] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 80 Fabric OS Version 3.1.x/4.1.x Reference Guide Example Enable a blade in slot 2: See Also switchshow bladedisable portdisable portenable switch:admin> bladeenable 2 10 9 8 7 6 5 4 3 2 1 fabric Principal switch ...

[Page 81] HP StorageWorks MSA 2/8 - SAN Switch

bladePropShow 81Fabric OS Version 3.1.x/4.1.x Reference Guide Displays blade property. Synopsis bladePropShow [-slot slot] Availability All users. Release V4.1.x Description Use this command to display the properties of a blade. Operands This comma...

[Page 82] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 82 Fabric OS Version 3.1.x/4.1.x Reference Guide See Also chippropshow ptpropshow ...

[Page 83] HP StorageWorks MSA 2/8 - SAN Switch

bsn 83Fabric OS Version 3.1.x/4.1.x Reference Guide Displays the serial number. Synopsis bsn Availability Admin Release V3.1.x Description Use this command to display the serial number. Note: To display the serial number for a component in V4.1.x, u...

[Page 84] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 84 Fabric OS Version 3.1.x/4.1.x Reference Guide Functional test of the CAM memory. Verify QuickLoop's Content Addressable Memory (CAM) SID translation. Synopsis: V3.1.x camtest [passcnt] Synopsis: V4.1.x camtest [--slot numb...

[Page 85] HP StorageWorks MSA 2/8 - SAN Switch

camTest 85Fabric OS Version 3.1.x/4.1.x Reference Guide domain and area fields of the SID zeroed. If a miss is expected (when the walking 1 or walking 0 pattern is used) the original SID in the frame transmitted is received unchanged. Note: This c...

[Page 86] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 86 Fabric OS Version 3.1.x/4.1.x Reference Guide Errors When failures are detected, the subtest may report one or more of the following error messages: ■ For V3.1.x DIAG-CAMINIT DIAG-XMIT DIAG-CAMSID ■ For V4.1.x DIAG-CAMFLTR ...

[Page 87] HP StorageWorks MSA 2/8 - SAN Switch

centralMemoryTest 87Fabric OS Version 3.1.x/4.1.x Reference Guide Test ASIC central memory operation. Synopsis: V3.1.x centralMemoryTest [passcount, datatype, dataseed] Synopsis: V4.1.x centralmemorytest [--slot number][-passcnt count][-datatype typ...

[Page 88] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 88 Fabric OS Version 3.1.x/4.1.x Reference Guide The test consists of 6 subtests: Subtest 1 The BISR subtest executes the Built-In-Self-Repair (BISR) circuitry in each ASIC. The BISR executes its own BIST, and cells found bad are ...

[Page 89] HP StorageWorks MSA 2/8 - SAN Switch

centralMemoryTest 89Fabric OS Version 3.1.x/4.1.x Reference Guide ASIC #3: 0xfff9d389, 0xfff9d388, 0xfff9d387, ... ASIC #4: 0xfff8c609, 0xfff8c608, 0xfff8c607, ... For V4.1.x, the default pattern used (by POST also) is a QUAD_RAMP with a seed value ...

[Page 90] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 90 Fabric OS Version 3.1.x/4.1.x Reference Guide Subtest 4 The forced bad parity error subtest verifies that a bad parity can be detected, and that its error flag and interrupt bits are set. The test method is as follows: 1. Clear...

[Page 91] HP StorageWorks MSA 2/8 - SAN Switch

centralMemoryTest 91Fabric OS Version 3.1.x/4.1.x Reference Guide Subtest 6 The forced bad chip number error subtest verifies that the bad buffer number in the data packet can be detected, its error flag and interrupt bits are set. The test method i...

[Page 92] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 92 Fabric OS Version 3.1.x/4.1.x Reference Guide Example To test the ASIC central memory in V3.1.x: -ports ports (V3.1.x only) Specify a set of ports to test. The data patterns are written into the ports specified and verified by...

[Page 93] HP StorageWorks MSA 2/8 - SAN Switch

centralMemoryTest 93Fabric OS Version 3.1.x/4.1.x Reference Guide To test the ASIC central memory in V4.1.x: Errors When this command detects failures, each subtest may report one or more of the following error messages: ■ For V3.1.x: Subtest 1 1)...

[Page 94] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 94 Fabric OS Version 3.1.x/4.1.x Reference Guide ■ For V4.1.x: Subtest 2 LCMEM_ERR LCMRS_ERR LCMTO_ERR Subtest 3 CM_NO_BUF LCMEMTX_ERR LCMRS_ERR LCMTO_ERR Subtest 4 BAD_INT CM_ERR_PTN CM_ERR_TYPE TIMEOUT Subtest 5 BAD_INT CM_ERR_...

[Page 95] HP StorageWorks MSA 2/8 - SAN Switch

cfgactvshow 95Fabric OS Version 3.1.x/4.1.x Reference Guide Displays Effective zone configuration information. Synopsis cfgactvshow Availability All users. Release V3.1.x and V4.1.x Description Use this command to display the Effective zone configura...

[Page 96] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 96 Fabric OS Version 3.1.x/4.1.x Reference Guide Example To show the Effective zone configuration information: See Also cfgclear cfgcreate cfgdelete cfgremove cfgsave cfgshow switch:admin> cfgactvshow Effective configuration: c...

[Page 97] HP StorageWorks MSA 2/8 - SAN Switch

cfgAdd 97Fabric OS Version 3.1.x/4.1.x Reference Guide Add a member to a zone configuration. Synopsis cfgAdd “cfgName”,”member;member” Availability Admin Release V3.1.x and V4.1.x Description Use this command to add one or more members to an ...

[Page 98] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 98 Fabric OS Version 3.1.x/4.1.x Reference Guide Operands This command has the following operands: Example To add two new zones to the configuration “Test_cfg”: See Also cfgClear cfgCreate cfgDelete cfgDisable cfgEnable cfgRem...

[Page 99] HP StorageWorks MSA 2/8 - SAN Switch

cfgClear 99Fabric OS Version 3.1.x/4.1.x Reference Guide Clear all zone configurations. Synopsis cfgClear Availability Admin Release V3.1.x and V4.1.x Description Use this command to clear all zone information in the transaction buffer. All defined ...

[Page 100] HP StorageWorks MSA 2/8 - SAN Switch

Fabric OS Commands 100 Fabric OS Version 3.1.x/4.1.x Reference Guide Example To clear all zones, and then clear non-volatile memory: See Also cfgAdd cfgCreate cfgDelete cfgDisable cfgEnable cfgRemove cfgSave cfgShow cfgTransAbort cfgtransshow switch:...