Download or browse on-line these Owner's Manual for Kenmore POWER MISER 153.326161 Water Heater.
This manual for Kenmore POWER MISER 153.326161, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 28 pages, and the size of the file at download is . The document type is Owner's Manual.
[Page 1] Kenmore POWER MISER 153.326161
Owner's Manuam POWER MISERTM ELECTRmC WATER HEATER FOR POTABLE WATER HEATING ONLY. NOT SUITABLE FOR SPACE HEATING, 6 MODEL NO. 153.326160 153.326161 153.326262 153.326263 30 Gallon Short 30 Gallon Short 38 Gallon Short 38 Gallon Short USTED o Sa...
[Page 2] Kenmore POWER MISER 153.326161
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safetyore[ated messages and instructions have been provided in this manual and on your own water heater to warn you and othe...
[Page 3] Kenmore POWER MISER 153.326161
Readandunderstandinstruction manualandsafetymessages beforeinstalling,operatingor servicingthiswaterheater. Failuretofollowinstructionsand safetymessagescouldresultin deathorseriousinjury. instructionmanualmustremain withwaterheater. Improper install...
[Page 4] Kenmore POWER MISER 153.326161
SAFE INSTALLATION, USEAND SERVICE ........................................................................................................................................ 2 GENERAL SAFETY .................................................................
[Page 5] Kenmore POWER MISER 153.326161
ThankYouforpurchasinga Searswaterheater.Properly installedandmaintained,it shouldgiveyouyearsoftrouble freeservice.Itisstronglysuggestedthatthisnewwaterheater beprofessionallyinstalled,contactthelocalSearsService CenteroranySearsstore.Theywillarrange...
[Page 6] Kenmore POWER MISER 153.326161
Materials Needed To simplify the installation Sears has available the installation parts shown below. You may or may not need al! of these materials, depending on your type of installation. WATER HEATER INSTALLATION Kr WRTH FLEXmBLE CONNECTORS FOR 3/...
[Page 7] Kenmore POWER MISER 153.326161
Removing the O_d Water Heater FIGURE 1. Q Turn "OFF" electrical supply to the water heater. FIGURE 2. Q Turn "OFF" the water to the water heater at the water supply shut-off valve or water meter. FIGURE 3. Q Attach a hose to the ,...
[Page 8] Kenmore POWER MISER 153.326161
FIGURE7. MineralBuilduporSedimentMayAccumulate oThiscausesthewaterheatertobecome muchheavierthannormal, oIfspiNed,couldcausestaining. Mineralbuilduporsedimentmayhaveaccumulatedintheold waterheater.Thiscausesthewaterheatertobemuchheavier thannormaland...
[Page 9] Kenmore POWER MISER 153.326161
Fire Hazard / Electric Shock Hazard Do not use this water heater with any voltage other than shown on the model rating plate, Failure to use the correct voltage shown on the model rating plate could result in death, serious bodily injury, or property...
[Page 10] Kenmore POWER MISER 153.326161
NOTE: To protect against untimely corrosion of hot and cored water fittings, it is strongly recommended that dioelectric unions or couplings be installed on this water heater when connected to copper pipe, 1. Look at the top cover of the water heater...
[Page 11] Kenmore POWER MISER 153.326161
ismadewithanyliveelectricalpart.Thedischargeopening must not be blockedor reducedin size underany circumstances.Excessivelength,over30feet(9.14m),oruse ofmorethanfourelbows can cause restriction and reduce the discharge capacity of the valve. Water D...
[Page 12] Kenmore POWER MISER 153.326161
productionoflistedequipmentormaterials.Thevalvemustbe oriented, providedwithtubing,orotherwiseinstalledsothat dischargecanexit only within 6 inches above, or at any distance below the structural floor, and cannot contact any live electrical part.&quo...
[Page 13] Kenmore POWER MISER 153.326161
Necessaryelementconversionpartsarelocatedina small bagcontainedwithintheelectricaljunctionboxontopof the waterheater. CONVERS_ONPARTS 1, 2, SCREW BUSS BAR FIGURE 12. Before beginning the conversion turn 'OFF" electric power supply to the wa...
[Page 14] Kenmore POWER MISER 153.326161
8. Tightenterminals2 and3 to ensureproperelectrical 11.Replacetheaccesspanel. connection. Fire and Explosion Hazard " Failure to tighten screws can cause a fire. ,, Failure to do this could resuHtin death, serious bodily injury, or property dama...
[Page 15] Kenmore POWER MISER 153.326161
Ifyouarenotfamiliarwithelectriccodesandpractices,orifyou haveanydoubt,eventheslightestdoubt,inyourabilitytoconnect thewiringtothiswaterheater,obtaintheserviceofacompetent electrician.ContactyourSearssalespersonto arrangefora professionalelectrician. ...
[Page 16] Kenmore POWER MISER 153.326161
Wiring Diagrams STANDARD WJR}NG FOR 2 WIRE LEAD WATER HEATERS NON=SIMULTANEOUS OPERATION 240 VOLT DOUBLE ELEMENT TO ELECTRIC POWER SUPPLY [ Before removing any access panels or servicing the water heater, make sure the electrical supply to the water ...
[Page 17] Kenmore POWER MISER 153.326161
Temperature Regulation Water temperature over 125°F (52°C) can cause severe burns instantly resulting in severe injury or death. Children, the elderly, and the physically or mentally disabled are at highest risk for scald injury. Feel water before ...
[Page 18] Kenmore POWER MISER 153.326161
NOTE:It is notnecessaryto adjusttheupperthermostat. However,ifit isadjustedabovethefactorysetpointof 120°F (49°C)HOTitisrecommendedthatitnotbesethigherthanthe lowerthermostatsetting. Theupperandlowerthermostatsareadjustableifa different watertemper...
[Page 19] Kenmore POWER MISER 153.326161
Thewaterheatershouldbedrainedifbeingshutdownduring freezingtemperatures.Also,periodicdrainingandcleaningof sedimentfromthetankmaybenecessary. i Before removing any access panels or servicing the water heater, make sure the ebctrical supply to the wat...
[Page 20] Kenmore POWER MISER 153.326161
[ 2. Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned "OFFL Failure to do this could result in death, serious bodily injury, or property damage. Before beginning turn ...
[Page 21] Kenmore POWER MISER 153.326161
8, g, Clean the area around the element opening, Remove any sediment from or around the element opening, inside the tank, If you are cleaning the element you have removed, do so by scraping or soaking in vinegar or a deoliming solution, Fire Hazard a...
[Page 22] Kenmore POWER MISER 153.326161
18. Replace access panel, 19. Turn "ON" electric power to water heater, Drain Valve Washer Repmacement Follow "Draining" instructions. See "Draining" section. Turning counter clockwise, remove the hex cap below the screw...
[Page 23] Kenmore POWER MISER 153.326161
Start Up Conditions THERMAL EXPANSmON Property Damage Hazard Avoid water heater damage, o Install thermal expansion tank or device if necessary. o Contact qualified installer or service agency. NOTE: Expansion tanks are preocharged with a 40 psi air ...
[Page 24] Kenmore POWER MISER 153.326161
D.Anexcessofactivehydrogeninthetank.Thisiscausedby corrosionprotectiveactionoftheanode. Smellywatermaybeeliminatedorreducedbychlorinatingthe waterheatertankanda!lhotwaterlines.Contactthelocal SearsServiceCenterconcerningthisChlorinationTreatment. Ifs...
[Page 25] Kenmore POWER MISER 153.326161
2_ 3. 4, 5. 6, 7, Make sure the electrica! supply to your water heater is "ONL Check for loose or blown fuses in your water heater circuit. Circuit breakers weaken with age and may not handle their rated load and should be replaced. Make certain...
[Page 26] Kenmore POWER MISER 153.326161
Leakagefromotherappliances,waterlines,orgroundseepage shouldalsobechecked. Note:Tocheckwherethreadedportionenterstank,insert cottonswabbetweenjacketopeningandfitting,ffcottonis wet,follow"Draining"instructionsinthe "Service and Mainten...
[Page 27] Kenmore POWER MISER 153.326161
KENMORE POWER MISER TM 6 ELECTRIC WATER HEATERS 153.326160 30 Gallon Short 153.326161 30 Gallon Short 153.326262 38 Gallon Short 153.326263 38 Gallon Short NOTE:A UPPER ELEMENT: These water heaters are equipped with 3800 watt elements. LOWER ELEMENT:...
[Page 28] Kenmore POWER MISER 153.326161
6 oYEAR LmMITEDWARRANTY ON WATER HEATER For six years from the date of purchase, if this water heater is installed and operated in a single-family home in accordance with the owner's manual instructions and al! Ioca! applicable plumbing codes, S...
Use and care manual (28 pages)
Owner's manual (32 pages)
Owner's manual (28 pages)