[Page 1] Miele T 9822

Installation Instructions T 9822 Gas Dryer To prevent accidents and appliance damage read these instructions before installation or use. M.-Nr. 07 431 110 en - US, CA ...

[Page 2] Miele T 9822

2 ...

[Page 3] Miele T 9822

3 , WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death. – Do not store or use gasoline or other flammable vapors and liquids in t...

[Page 4] Miele T 9822

IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Stand .........................

[Page 5] Miele T 9822

Installation and connection , WARNING - Risk of Fire When using your gas appliance follow basic safety precautions including the following: ~ It is essential to read all instructions before installing the appliance. ~ To reduce the risk of severe inj...

[Page 6] Miele T 9822

~ Do not install a clothes dryer with flexible plastic venting materials. If flexible metal (foil type) duct is installed, it must be of a specific type identified by the manufacturer as suitable for use with clothes dryers. Flexible venting material...

[Page 7] Miele T 9822

Front view a Exhaust connection b Power cord with plug c Control panel d Door e Four height adjustable screw feet Stand A dryer stand, with drawer, can be purchased as an optional accessory. Installation 7 ...

[Page 8] Miele T 9822

Rear a Handle for transportation (arrows) b Power cord with plug c Slot for module d Air intake e Gas connection f Exhaust connection with restriction insert , WARNING : Do not remove the restriction insert in the vent opening. It may result in poor ...

[Page 9] Miele T 9822

, WARNING: Do not install the dryer: - outdoors - in an environment with dripping water or weather - near flammable materials - in rooms which may contain gas or other fuels - in closets with solid doors - with other fuel-burning appliances in the sa...

[Page 10] Miele T 9822

Confined space installation ^ When installed in any space with less than 122 square feet (11.3 m 2 ), minimum clearances around the dryer must be adhered to for proper ventilation and vents for make up air must be installed. ^ Do not install any othe...

[Page 11] Miele T 9822

Transporting the dryer to the installation site The rear of the lid has a handle for transportation. ^ Use the front dryer feet and the rear of the lid to move the dryer to the installation site. Level the dryer The dryer must be level to ensure safe...

[Page 12] Miele T 9822

, WARNING Before installation, disconnect the tumble dryer from the electrical supply by shutting off the power main or tripping the circuit breaker. Be sure the dryer power cord is unplugged from the wall. Do not restore power until the installation...

[Page 13] Miele T 9822

, GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance. This appliance is equipped with a cord having an equipment g...

[Page 14] Miele T 9822

, WARNING Installation and service must be performed by a qualified installer, service agency or gas supplier. In Massachusetts a licensed plumber / gas fitter is required. This appliance must be installed with its own shut off valve in the same room...

[Page 15] Miele T 9822

Gas supply Installation material (hoses and adapters) must be provided by the installer. Gas connection distances This appliance must be installed with its own shut off valve on the gas supply line. The valve must be within 6 ft. (1.8 m), and in the ...

[Page 16] Miele T 9822

, To secure all connections use appropriate Teflon tape or a thread compound, suitable for gas connections. ^ At the end of the dryer's gas connection hand screw on the 3 / 8 " NPT elbow. Using a wrench tighten the elbow with a half turn. ,...

[Page 17] Miele T 9822

^ Using two wrenches tighten the flexible gas line connection. ^ Connect the flare union adapter, a, to the pressure tapping plug, b, originally installed on the gas shut off valve, c. ^ Using two wrenches tighten all connections. , DO NOT OVERTIGHTE...

[Page 18] Miele T 9822

Exhaust ducting and connections A gap of 3 / 8 " (10 mm) must be provided between the appliance and the floor. This gap is necessary for proper air flow and must not be blocked by a toe-kick or thick piled carpets. Sufficient venting of the inst...

[Page 19] Miele T 9822

How to calculate the effective duct length The overall duct length will determine the duct diameter (see the "Additional duct lengths" table). In Canada the exhaust duct must be 4" (102 mm) in diameter. ^ Measure the actual duct length...

[Page 20] Miele T 9822

Tips about the ductwork – Check with your local building code to determine the maximum allowable duct length. – Only use rigid or flexible metal duct for exhausting. Non-metallic flexible hose should not be used, it is a potential fire hazard. �...

[Page 21] Miele T 9822

Additional duct lengths (4" [100 mm] rigid pipe only) Type of bend Radius Additional duct length inches cm ft cm Flexible metal duct – 3’ 3" (1 m) straight – 45° angle – 90° angle 10" 10" 25 25 5’ 11" 4’ 11"...

[Page 22] Miele T 9822

Example Rigid pipe Duct length ft Duct length m A Wall duct with louvered wall vent 12’ 5" 3.8 m B 90° bend 2’ 4" 0.7 m C 20" (0.5 m) rigid pipe 1’ 7" 0.5 m D 90° bend 2’ 4" 0.7 m E left / right vent opening 3'...

[Page 23] Miele T 9822

Exhaust connection with a flexible exhaust hose or rigid pipe Using the adapter supplied, an exhaust hose (4" [100 mm] diameter) can be installed. Necessary materials: – a wall or window duct (available from Miele) – an exhaust hose made of ...

[Page 24] Miele T 9822

^ Install the exhaust hose 3 in the dryer using the adapter 2 and the restriction insert 3. If using the gray adapter without clips : ^ Plug the restriction insert 1 into the gray adapter without clips 2 and connect the pipe 3. Window connection (exa...

[Page 25] Miele T 9822

Direct wall connection Necessary materials: – a wall pipe – flexible foam gasket Dryer top view 1 Wall pipe 2 Flexible foam gasket Dryer side view 1 Wall pipe 2 Flexible foam gasket ^ Only required with side exhaust vent connection (left or right...

[Page 26] Miele T 9822

Disposal of the packing materials The packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. To prevent suffocation, ensure that any plastic wrappings, bags, etc. are disposed of safely an...

[Page 27] Miele T 9822

27 ...

[Page 28] Miele T 9822

Alteration rights reserved / 1612 INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION. M.-Nr. 07 431 110 / 04 ...