[Page 1] Montigo H38-DF

H38DF HL38DF HR38DF HW38DF Indoor Resi dential Fireplace ® C US Read and understand this manual. Improper installation, adjustment, alteration, service or maintenance can cause serious injury, property damage or even death. For assistance...

[Page 2] Montigo H38-DF

 You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance. NOTICE Table of Contents �...

[Page 3] Montigo H38-DF

  Safety Alert Key XG0147 -011912 Introduction Indicates a hazardous situation which, if not avoided, WILL result in death or serious injury or property damage. Ind...

[Page 4] Montigo H38-DF

 XG0147 - 011912.1  Installation  IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS The ...

[Page 5] Montigo H38-DF

 XG0147 - 011912.1  Installation �...

[Page 6] Montigo H38-DF

 XG0147 - 011912.1  Installation  1). Frame in the enclosure for the unit with framing materials. The framed ope...

[Page 7] Montigo H38-DF

 XG0147 - 011912.1  Installation 6”  When installing a shelf over the top of the replaces, the following guidelines must b...

[Page 8] Montigo H38-DF

 XG0147 - 011912.1  Installation  Flue cover and collar removal, Top Vented replac...

[Page 9] Montigo H38-DF

 XG0147 - 011912.1  Installation . Top vent, Roof mounted termination with no offset in vent run.  Top vent, Roof ...

[Page 10] Montigo H38-DF

 XG0147 - 011912.1  Installation  Rear vent, Roof mounted venting (1 = 90° bend). Support ring Support plate 32’ max P VTK1 Terminat...

[Page 11] Montigo H38-DF

 XG0147 - 011912.1  Installation 1 12” 2” 1 2” 12” �...

[Page 12] Montigo H38-DF

 XG0147 - 011912.1  Installation 42” 46” A C B If your installation does not fall within the venting graph para- meters, please contact a local Montigo dealer for...

[Page 13] Montigo H38-DF

 XG0147 - 011912.1  Installation  Corner installation. (NG Models Only)  Flex installation. (NG Models Onl...

[Page 14] Montigo H38-DF

 XG0147 - 011912.1  Installation  Rear Vented, wall mounted Multi-elbow termination installation. Installation for H*38DF* must have a...

[Page 15] Montigo H38-DF

 XG0147 - 011912.1  Installation   �...

[Page 16] Montigo H38-DF

 XG0147 - 011912.1  Installation  ...

[Page 17] Montigo H38-DF

 XG0147 - 011912.1  Installation  Wiring Diagram for the SIT Proame Electron...

[Page 18] Montigo H38-DF

 XG0147 - 011912.1  Installation  which employ the fans must be grounded in accordance with loca...

[Page 19] Montigo H38-DF

 XG0147 - 011912.1  Installation   After gas lin...

[Page 20] Montigo H38-DF

 XG0147 - 011912.1  Installation   Combustible mantels and facings. �...

[Page 21] Montigo H38-DF

 XG0147 - 011912.1  Installation  Removing ...

[Page 22] Montigo H38-DF

 XG0147 - 011912.1  Installation  ...

[Page 23] Montigo H38-DF

 XG0147 - 011912.1  Installation Optional Cultured Rocks The  has the option of installing the cultured rocks which mimic real stone. These may be ...

[Page 24] Montigo H38-DF

 XG0147 - 011912.1  Installation  The �...

[Page 25] Montigo H38-DF

 XG0147 - 011912.1  Installation  The is supplied wi...

[Page 26] Montigo H38-DF

  XG0147 - 011912.1 Operation   If you cannot reach your gas supplier, call the F...

[Page 27] Montigo H38-DF

  XG0147 - 011912.1 Operation To Turn Off Gas To Appliance:  Turn off remote switch.  Remove the lower Horizontal access panel.  Turn the incom...

[Page 28] Montigo H38-DF

  XG0147 - 011912.1 Operation  If you cannot reach your gas supplier, call the Fire Department.  Use only your hand to push in or turn the gas control knob. ...

[Page 29] Montigo H38-DF

  XG0147 - 011912.1 Maintenance  See pages 26 to 28. CAUTION!  Fireplace gas control must be in th...

[Page 30] Montigo H38-DF

  XG0147 - 011912.1 Maintenance  The following is a troubleshooting chart of possible problems: If your replace still does not operate c...

[Page 31] Montigo H38-DF

  XG0147 - 011912.1 Replacement Parts      RGC1006 RGC1006 RGC10...

[Page 32] Montigo H38-DF

 XG0147 - 011912.1  Appendix  Location Canada* USA** A clearance to the t...

[Page 33] Montigo H38-DF

 XG0147 - 011912.1  Appendix   The Companies warrants the Montigo Gas App...

[Page 34] Montigo H38-DF

 XG0147 - 011912.1  Appendix   ...

[Page 35] Montigo H38-DF

 XG0147 - 011912.1  Notes ...

[Page 36] Montigo H38-DF

 TF: 1.800.789.6236 FX: 1.866.3000.0927 XG0147 - 011912.1  TF: 1.800.378.3115 FX: 1.604.607.6462 H38DF Residential ...