[Page 1] Oakton Temp-16

Instruction Manual Temp-16 Precision RTD Thermometer 68X481904 Rev 0 09 / 0 9 Part of Thermo Fisher Scientific ...

[Page 2] Oakton Temp-16

...

[Page 3] Oakton Temp-16

TABLE OF CONTENTS Quick Start Guide............................................ 1 1. Introduction .............................................. 2 2. Safety Precautions................................... 3 3. Specifications................

[Page 4] Oakton Temp-16

...

[Page 5] Oakton Temp-16

1 QUICK START GUIDE To ensure best results please read the complete manual. 1. Connect probe. 2. Press the on/off key. Press again to turn on backlight. 3. Select °C or °F display using °C/°F key. 4. Insert probe in sample. Al...

[Page 6] Oakton Temp-16

2 1. INTRODUCTION Thank you for choosing the Temp-16 Precision RTD Thermometer.This versatile hand-held instrument provides highly accurate temperature measurements and is designed for easy operation which includes the following features:...

[Page 7] Oakton Temp-16

3 2. SAFETY PRECAUTIONS Voltages present at the RTD may also be present at the battery terminals. Always disconnect the RTD when changing batteries. W WARNIN G This instrument is designed to accept low level signals supplied by stan...

[Page 8] Oakton Temp-16

4 3. SPECIFICATIONS Platinum RTD Probes 100 ohm platinum: alpha = 0.003850 –200 °C to 850 °C (–392 °F to 1562 °F) Out of range display: “Ur”, “Or”, “OPEN” Range Accuracy –200.0 to –100.0 °C (–392 to –148 °F) ...

[Page 9] Oakton Temp-16

5 Weight Without armour With armour 267 g 362 g Ingress Protection (With Probe Attached) Meets IEC-529 IP-54 for dust and water-resistant enclosures. CE Compliance EN61326-1/A1: 1998 (EU EMC Directive) ...

[Page 10] Oakton Temp-16

6 4. BATTERY INSTALLATION AND REPLACEMENT Voltages present at the RTD may also be present at the battery terminals. Always disconnect the RTD when changing batteries. Weak batteries should not be left in the instrument. Dead batteries ...

[Page 11] Oakton Temp-16

7 5. INSERTING AND REMOVING OPTIONAL RUBBER ARMOUR Figure 1: Removing Optional Rubber Armour 1. To insert thermometer into the optional rubber armor, slide in from the top of meter before pushing the bottom edges of mete...

[Page 12] Oakton Temp-16

8 6. ASSEMBLING OPTIONAL HANDSFREE ACCESORIES You can use the optional magnets and strap in the Hands Free Kit accessories for hands- free operations. Figure 2: Hands Free Kit ...

[Page 13] Oakton Temp-16

9 7. CONNECTING AN RTD PROBE Use the correct 100 Ω RTD (alpha = 0.003850) for your instrument. Using an incorrect probe type will result in erroneous readings. Insert the 3-pin plug into the mating connector on the top of the instrument....

[Page 14] Oakton Temp-16

10 8. KEY FUNCTIONS Figure 4: Keypad °C/°F Toggles between Celsius or Fahrenheit in measurement mode and user calibration mode. cal Press and hold this key for 3 seconds to enter Calibration mode if field calibration is unprotected....

[Page 15] Oakton Temp-16

11 9. DISPLAY OVERVIEW Figure 5: Meter Display °C/°F Celsius or Fahrenheit indicator. MIN Minimum reading annunciator. MAX Maximum reading annunciator. 3 Bar : 700 – 550 hours 2 Bar : 350 – 550 hours 1 Bar : 150 �...

[Page 16] Oakton Temp-16

12 10. MEASUREMENT MODE Press the on/off key. The thermometer performs a self-test and all display digits and indicators should remain on for approximately two seconds before the meter enters measurement mode. If a probe is not connected or ...

[Page 17] Oakton Temp-16

13 11. SELECTING TEMPERATURE SCALE 24.6 °c 75.4 °F Figure 8: Press °C/°F key to toggle between °C and °F Select °C or °F by pressing the °C/°F key . Eac h tim e the key is pressed, th e temperatur e scale wi...

[Page 18] Oakton Temp-16

14 12. MIN AND MAX FUNCTION Press the min/max key to toggle between the minimum and maximum readings. The minimum and maximum reading function is ideal for monitoring unattended operations while continually displaying every temperature chang...

[Page 19] Oakton Temp-16

15 14. CALIBRATION The CAL function allows single point calibration of the thermometer at 0°C (32°F) to compensate for probe offset error. Use the field calibration feature to improve thermometer/probe accuracy. The Temp-16 Precision RTD T...

[Page 20] Oakton Temp-16

16 15. CLEAR FIELD CALIBRATION To clear user calibration: 1. Turn the thermometer off. 2. Hold the cal key down while pressing the on/off key. 3. The measurement mode window appears without the CAL indicator to indicate that the user calib...

[Page 21] Oakton Temp-16

17 4. When the cal and hold keys are released, the unit will go to measurement mode (Figure 11). °c ST ABL E Figure 11: Unit goes to measurement mode 17. FIELD CALIBRATION LOCKOUT The calibration lockout feature prevents any field ca...

[Page 22] Oakton Temp-16

18 4. When the cal and °C/°F keys are released, the unit will return to measurement mode (Figure 13). °c ST ABL E Figure 13: Unit returns to measurement mode 18. MAINTENANCE Properly used, the thermometer should maintain calibration indef...

[Page 23] Oakton Temp-16

19 20. TROUBLESHOOTING Problem Cause Solution Power on but no display Batteries not in place or wrong polarity. Insert batteries. or re-insert batteries in correct polarity. “OPEN” display on LCD Probe not connected Make sure...

[Page 24] Oakton Temp-16

20 21. SERVICE There are no internal adjustments or user replaceable parts. Note: Serial number label is located behind the meter. 22. REPLACEMENT METER & ACCESSORIES Item Thermo Scientific Rubber Armour with Stand 35427-80 Hands ...

[Page 25] Oakton Temp-16

21 23. WARRANTY T he Manufac turer warra nts this product to be free from significant deviations from published specifications for a period of three ye ars. If repair or adjus tment is necessary wi t hin the warra nt y pe...

[Page 26] Oakton Temp-16

22 25. INNOCAL® CALIBRATION AND REPAIR SERVICES (NORTH AMERICA) Optimum performance of your temperature- measuring instrument is not a timeless condition. To ensure quality measurements, have your instrument calibrated regularly. Trust Inn...

[Page 27] Oakton Temp-16

23 years of experience and extensive technical data. Convenient Reminders It’s so easy to keep your instruments functioning properly. Based on your requirements, InnoCal will send you a reminder when it’s time to re-certify or service you...

[Page 28] Oakton Temp-16

24 Are your calibration certificates good enough? InnoCal surpasses the competition by providing the most complete certificates as required by NIST. All of our certificates include measured data and point-by-point measurement uncertainty, and ...

[Page 29] Oakton Temp-16

25 26. TECHNICAL ASSISTANCE If you have any questions abo ut the use of this prod uct, contact the Manufacturer or authorized se ller. For more information on OAKTON Instruments Products, please contact your nearest distrib...

[Page 30] Oakton Temp-16

...

[Page 31] Oakton Temp-16

...

[Page 32] Oakton Temp-16