[Page 1] Immergas VICTRIX Superior TOP 32 E

VICTRIX Superior TOP 32 E IE Instruction and warning book *1.032471IE* ...

[Page 2] Immergas VICTRIX Superior TOP 32 E

1 Boiler installation ................................................ 3 1.1 Installation recommendations. ......................... 3 1.2 Main dimensions. ............................................... 4 1.3 Anti-freeze protection. ...................

[Page 3] Immergas VICTRIX Superior TOP 32 E

SI NO 3 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 1 BOILER INSTALLATION 1.1 INSTALLATION RECOMMENDATIONS. The Victrix Superior TOP I boiler has been designed for wall mounted installation only; for heating environments and production of domesti...

[Page 4] Immergas VICTRIX Superior TOP 32 E

4 - IE INSTALLERUSER MAINTENANCE TECHNICIAN Fig. 1-2 1.2 MAIN DIMENSIONS. Key: V - Electrical connection G - Gas supply AC - Domestic hot water outlet AF - Domestic hot water inlet SC - Condensate drain (minimum internal diameter Ø13 mm...

[Page 5] Immergas VICTRIX Superior TOP 32 E

CAVO ALIMENTAZIONE 5 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 1.4 CONNECTION UNIT SUPPLIED AS STANDARD WITH THE BOILER. Gas connection (Appliance category II 2H3B/P ). Our boilers are designed to operate with methane gas (G20) and LPG. Supp...

[Page 6] Immergas VICTRIX Superior TOP 32 E

45 31 58 6 - IE INSTALLERUSER MAINTENANCE TECHNICIAN Comando Amico Remoto remote control V2 (CAR V2 ) On/O digital chrono-thermostat. Fig. 1-4 Super Comando Amico Remoto remote control (Super CAR) Fig. 1-5 Fig. 1-6 Fig. 1-7 TM-MAX/MIN = Selecte...

[Page 7] Immergas VICTRIX Superior TOP 32 E

(A) (B) 7 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 1.7 IMMERGAS FLUE SYSTEMS. Immergas supplies various solutions separately from the boilers regarding the installation of air intake terminals and ue extraction, which are fundamental for boil...

[Page 8] Immergas VICTRIX Superior TOP 32 E

8 - IE INSTALLERUSER MAINTENANCE TECHNICIAN TYPE OF DUCT Resistance Factor (R) Equivalent length in m of concentric pipe Ø60/100 Equivalent length in metres of pipe Ø80 Equivalent length in metres of pipe Ø60 Equivalent length in m o...

[Page 9] Immergas VICTRIX Superior TOP 32 E

9 - IE INSTALLERUSER MAINTENANCE TECHNICIAN Fig. 1-12 Fig. 1-10 Fig. 1-9 1.9 OUTDOOR INSTALLATION IN PARTIALLY PROTECTED AREA. N.B.: a partially protected area is one in which the appliance is not exposed to the direct action of the weather (rain...

[Page 10] Immergas VICTRIX Superior TOP 32 E

5 4 3 1 2 1 2 3 4 5 6 C13 C13 C13 C13 10 - IE INSTALLERUSER MAINTENANCE TECHNICIAN Fig. 1-13 Fig. 1-14 e kit includes: N° 1 - Gasket (1) N° 1 - Concentric bend Ø60/100 (2) N° 1 - Concentric intake-exhaust terminal Ø60/100 (3) N° 1 - ...

[Page 11] Immergas VICTRIX Superior TOP 32 E

C33 C33 C33 C33 7 4 6 5 1 2 3 1 2 3 4 5 6 7 11 - IE INSTALLERUSER MAINTENANCE TECHNICIAN Fig. 1-18 Fig. 1-20Fig. 1-19 e kit includes: N° 1 - Gasket (1) N° 1 - Female concentric ange (2) N° 1 - Wall sealing plate (3) N° 1 - Aluminium...

[Page 12] Immergas VICTRIX Superior TOP 32 E

C83 C43C53 1 4 7 9 5 5 6 7 8 3 2 S A 12 - IE INSTALLERUSER MAINTENANCE TECHNICIAN e kit includes: N° 1 - Exhaust gasket (1) N° 1 - Flange gasket (2) N° 1 - Female intake ange (3) N° 1 - Female exhaust ange (4) C83 Fig. 1-23 C53 F...

[Page 13] Immergas VICTRIX Superior TOP 32 E

1 2 3 3 3 4 5 6 7 6 8 9 A 10 11 12 12 A B A C 13 - IE INSTALLERUSER MAINTENANCE TECHNICIAN Kit composition: Ref. Qty Description 1 1 Door adapter Ø100 or Ø125 2 1 Door gasket in neoprene 3 4 Screws 4.2 x 9 AF 4 1 Screw TE M6 x 20 5 1 Flat washer in...

[Page 14] Immergas VICTRIX Superior TOP 32 E

C83C93 X C93 14 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 1.14 DUCTING OF FLUES OR TECHNICAL SLOTS. Ducting is an operation through which by the introduction of one or more relevant pipes, a system is realised for the evacuation of the combustion...

[Page 15] Immergas VICTRIX Superior TOP 32 E

15 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 1.17 FLUES, CHIMNEYS, CHIMNEY CAPS AND TERMINALS. e ues, chimneys and chimney caps for the evacuation of combustion products must be in compliance with standards in force. e chimney caps and t...

[Page 16] Immergas VICTRIX Superior TOP 32 E

A B 16 - IE INSTALLERUSER MAINTENANCE TECHNICIAN Fig. 1-28 Head available to the system. Key: A+B = Head available with by-pass excluded (closed) in Auto mode B = Head available with by-pass inserted (open) in Auto mode Head (m H 2 O) Flow rate...

[Page 17] Immergas VICTRIX Superior TOP 32 E

17 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 1.24 BOILER COMPONENTS. Fig. 1-29 Key: 1 - Domestic hot water ow rate adjuster 2 - Condensate drain trap 3 - Gas valve 4 - Domestic hot water probe 5 - Safety thermostat 6 - Gas nozzle 7...

[Page 18] Immergas VICTRIX Superior TOP 32 E

18 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 2 INSTRUCTIONS FOR USE AND MAINTENANCE. 2.1 CLEANING AND MAINTENANCE. Attention: the heating systems must undergo periodical maintenance (regarding this, see the section dedicated to the maintenance ...

[Page 19] Immergas VICTRIX Superior TOP 32 E

19 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 2.4 DESCRIPTION OF FUNCTIONING STATES. Below nd a list of boiler functioning states that appear on the multifunction display (24) by means of the indicator (6) with a brief description. Refer to th...

[Page 20] Immergas VICTRIX Superior TOP 32 E

20 - IE INSTALLERUSER MAINTENANCE TECHNICIAN • Functioning with external probe (part. 18) optional. In the case of a system with optional external probe, the boiler ow temperature for room central heating is managed by the external probe dep...

[Page 21] Immergas VICTRIX Superior TOP 32 E

21 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 2.6 FAULT AND ANOMALY SIGNALS. The Victrix Superior TOP boiler signals any anomalies by the flashing symbol (5) along with the “ERRxx” indication on the indicator (6) where “xx” corresponds to ...

[Page 22] Immergas VICTRIX Superior TOP 32 E

1 2 3 4 22 - IE INSTALLERUSER MAINTENANCE TECHNICIAN Fig. 2-8 Low power supply voltage is occurs when the power supply voltage is lower than the allowed limits for the correct functioning of the boiler. If normal conditions are restored, the b...

[Page 23] Immergas VICTRIX Superior TOP 32 E

23 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 1 st Level Button 2 nd Level Button 3 rd Level Button Description M1 D Ö Õ C P11 D Ö Õ C View the management soware version of the P.C.B. installed in the boiler. P12 View the total functioning h...

[Page 24] Immergas VICTRIX Superior TOP 32 E

24 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 1 st Level Button 2 nd Level Button Description M9 D Ö Õ C P91 D Ö Õ C Displays the current temperature of the low temperature zone number 2. P92 D Ö Õ C Displays the current temperature of the low...

[Page 25] Immergas VICTRIX Superior TOP 32 E

25 - IE INSTALLERUSER MAINTENANCE TECHNICIAN Fig. 3-1 3 BOILER COMMISSIONING INITIAL CHECK To commission the boiler: - ensure that the declaration of conformity of installation is supplied with the appliance; - ensure that the type of gas u...

[Page 26] Immergas VICTRIX Superior TOP 32 E

6 17 7 18 6 7 8 6 12 13 10 10 11 14 10 11 7 6 5 2 3 4 1 11 10 7 6 7 6 7 6 9 8 9 8 6 6 7 7 15 13 10 13 11 12 14 16 16 8 7 6 CH ON 26 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 3.2 WIRING DIAGRAM. Fig. 3-2 Remote controls: the boiler is designed to use ...

[Page 27] Immergas VICTRIX Superior TOP 32 E

+ + 3 12 2 1 P1 P3 + + 3 12 1 P1 2 P3 27 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 3.4 CONVERTING THE BOILER TO OTHER TYPES OF GAS. If the boiler has to be converted to a dierent gas type to that specied on the data plate, request the relat...

[Page 28] Immergas VICTRIX Superior TOP 32 E

28 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 3.6 ADJUSTMENT OF THE AIRGAS RATIO. Attention: the verication operations of the CO 2 must be carried out with the casing mounted, while the gas valve calibration operations must be carried out ...

[Page 29] Immergas VICTRIX Superior TOP 32 E

29 - IE INSTALLERUSER MAINTENANCE TECHNICIAN M5 menu (password must be entered) 1 st Level 2 nd Level Options Description Default value Value set by the technician P50 25 ÷ 50 Set the boiler heat output in ignition phase. e value is in perce...

[Page 30] Immergas VICTRIX Superior TOP 32 E

30 - IE INSTALLERUSER MAINTENANCE TECHNICIAN M5 menu (password must be entered) 1 st Level 2 nd Level Options Description Default value Value set by the technician SERVICE P67 P67.1 In winter mode the pump is always powered and so functions co...

[Page 31] Immergas VICTRIX Superior TOP 32 E

31 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 3.9 "CHIMNEY SWEEP FUNCTION" F2. If this function is activated it takes boiler functioning to the adjustable power of the central heating selector switch. In this state all adjustments a...

[Page 32] Immergas VICTRIX Superior TOP 32 E

Part. A Part. B 8 7 11 10 A A A A 2 B B 9 4 4 3 6 8 7 8 5 5 1 32 - IE INSTALLERUSER MAINTENANCE TECHNICIAN - Check visually that the safety and control devices have not been tampered with and/or shorted, in particular: - temperature safety thermo...

[Page 33] Immergas VICTRIX Superior TOP 32 E

33 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 3.18 VARIABLE HEAT POWER. N.B.: the pressures indicated in the table represent the differences of pressures at the ends of the Venturi mixer and can be measured from the pressure point in the upper part...

[Page 34] Immergas VICTRIX Superior TOP 32 E

34 - IE INSTALLERUSER MAINTENANCE TECHNICIAN 3.20 TECHNICAL DATA. - Flue temperature values refer to an air inlet temperature of 15°C and delivery temperature of 50°C. - The data relevant to domestic hot water performance refers to a dynamic inl...

[Page 35] Immergas VICTRIX Superior TOP 32 E

...

[Page 36] Immergas VICTRIX Superior TOP 32 E

mmergas.com Immergas S.p.A. 42041 Brescello (RE) - Italy T. +39.0522.689011 F. +39.0522.680617 is instruction booklet is made of ecological paper. Code 1.032471IE rev. 15.036945/001 - 09/2012 ...