[Page 1] Adam Equipment HIGHLAND SERIES

© Adam Equipment Company 2011 Adam Equipment HIGHLAND SERIES (P.N. 9520, Revision E, October 2011) ...

[Page 2] Adam Equipment HIGHLAND SERIES

© Adam Equipment Company 2011 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when power is first turned on): Date of Purchase: Name...

[Page 3] Adam Equipment HIGHLAND SERIES

1 | P a g e © Adam Equipment Company 2011 1.0 CONTENTS 1.0 CONTENTS...........................................................................................1 2.0 INTRODUCTION.................................................

[Page 4] Adam Equipment HIGHLAND SERIES

2 | P a g e © Adam Equipment Company 2011 ...

[Page 5] Adam Equipment HIGHLAND SERIES

3 | P a g e © Adam Equipment Company 2011 2.0 INTRODUCTION Thank you for purchasing your new Highland TM portable balance, Every Highland TM balance has all the features you really need: AC adapter and internal rechargeable ...

[Page 6] Adam Equipment HIGHLAND SERIES

4 | P a g e © Adam Equipment Company 2011 3.2 DISPLAY / KEYBOARD FUNCTION The display and keypad have a number of features the key information is shown below: KEYS PRIMARY FUNCTION SECONDARY FUNCTIO...

[Page 7] Adam Equipment HIGHLAND SERIES

5 | P a g e © Adam Equipment Company 2011 ...

[Page 8] Adam Equipment HIGHLAND SERIES

6 | P a g e © Adam Equipment Company 2011 3.4 LOCATING AND PROTECTING YOUR BALANCE In order to keep your balance functioning at its best we suggest that you do the following: Avoid extremes of temp...

[Page 9] Adam Equipment HIGHLAND SERIES

7 | P a g e © Adam Equipment Company 2011 3.5 STORING WHEN NOT IN USE If you have any of the Highland TM series or Core Balance TM lines you can store them easily on top of each other. To save space and protect them...

[Page 10] Adam Equipment HIGHLAND SERIES

8 | P a g e © Adam Equipment Company 2011 4.0 BASIC OPERATION 4.1 TURNING ON THE BALANCE Plug in the unit using the AC adapter or use the internal rechargeable battery. It is recommended that you charge the battery for ...

[Page 11] Adam Equipment HIGHLAND SERIES

9 | P a g e © Adam Equipment Company 2011 4.4 WEIGHING To determine the weight of a sample, first tare an empty container (if used), then place the sample in the container. The display will show the weight of the sample ...

[Page 12] Adam Equipment HIGHLAND SERIES

10 | P a g e © Adam Equipment Company 2011 5.0 FUNCTIONS 5.1 PERCENTAGE WEIGHING The balance will allow a reference weight to be shown as 100%. Then any other weight placed on the balance will be displaye...

[Page 13] Adam Equipment HIGHLAND SERIES

11 | P a g e © Adam Equipment Company 2011 5) Press [Smpl] again once you have selected the sample. The display will show you the number. As more parts are added the display will show the total number of parts (PCS �...

[Page 14] Adam Equipment HIGHLAND SERIES

12 | P a g e © Adam Equipment Company 2011 To view the totals in memory press the [Print] key when the balance is at zero. The display will show ACC xx (where “xx” is the total number of readings) and the total weight, befor...

[Page 15] Adam Equipment HIGHLAND SERIES

13 | P a g e © Adam Equipment Company 2011 6.0 PARAMETERS The balance has 7 parameters that can be set by the user. FUNCTION SECTION DESCRIPTION F1 UNT See section 6.1 Sets the units to be used g / ct / Lb / oz / d / G...

[Page 16] Adam Equipment HIGHLAND SERIES

14 | P a g e © Adam Equipment Company 2011 6) When F1 Unt is displayed, you can press the [Print] key to return to weighing or press [Mode] to go to the next function. The following table shows different units which are ...

[Page 17] Adam Equipment HIGHLAND SERIES

15 | P a g e © Adam Equipment Company 2011 1) To set this parameter press the [Mode] key during self-checking test when turning on the balance. 2) After a few seconds, the display will show the first function F1 U...

[Page 18] Adam Equipment HIGHLAND SERIES

16 | P a g e © Adam Equipment Company 2011 P3 AUT The weighing results will be sent to the communication port automatically whenever a stable reading is present. The balance has to return to zero before another reading is sen...

[Page 19] Adam Equipment HIGHLAND SERIES

17 | P a g e © Adam Equipment Company 2011 9) Format settings. The scale will print either using a format that includes stability indications or one with only the weight. There are 2 settings that the Highland can wor...

[Page 20] Adam Equipment HIGHLAND SERIES

18 | P a g e © Adam Equipment Company 2011 1) To set this parameter press the [Mode] key during self-checking test when turning on the balance. 2) After a few seconds, the display will show the first function F1 UNT...

[Page 21] Adam Equipment HIGHLAND SERIES

19 | P a g e © Adam Equipment Company 2011 Changing the value of the internal weight will affect the calibration when using the internal calibration. To check if your internal weight is correct you should only use ...

[Page 22] Adam Equipment HIGHLAND SERIES

20 | P a g e © Adam Equipment Company 2011 7.0 CALIBRATION The Highland series of balances comes standard with HandiCal TM internal calibration to make calibrating the balance quick and easy. However you can also calibrate the ...

[Page 23] Adam Equipment HIGHLAND SERIES

21 | P a g e © Adam Equipment Company 2011 External Calibration 1) Press the [on/off] key to turn the power on. 2) Press the [Smpl] and [Print] keys at the same time during the self-checking test. 3) The display ...

[Page 24] Adam Equipment HIGHLAND SERIES

22 | P a g e © Adam Equipment Company 2011 8.0 TROUBLE SHOOTING 8.1 ERROR MESSAGES If an error message is shown, repeat the step that caused the message. If the error message is still shown then contact your dealer for s...

[Page 25] Adam Equipment HIGHLAND SERIES

23 | P a g e © Adam Equipment Company 2011 8.2 REPLACEMENT PARTS AND ACCESSORIES If you need to order any spare parts and accessories, contact your supplier or Adam Equipment. A partial list of the more common items follo...

[Page 26] Adam Equipment HIGHLAND SERIES

24 | P a g e © Adam Equipment Company 2011 9.0 SPECIFICATIONS 9.1 TECHNICAL SPECIFICATIONS HCB123 HCB153 HCB302 HCB602 HCB602H HCB1002 HCB1502 HCB3001 Maximum Capacity 120g 150g 300g 600g 60...

[Page 27] Adam Equipment HIGHLAND SERIES

25 | P a g e © Adam Equipment Company 2011 Connection details are: Generally a Null model cable is required for connection to a computer or printers. USB Connection is using a standard USB connector. Software ...

[Page 28] Adam Equipment HIGHLAND SERIES

26 | P a g e © Adam Equipment Company 2011 Format 2 Output: The output will be the same value as is on the display. If parts counting it iwl be the count, if weighing it is only the weight. An example output is ...

[Page 29] Adam Equipment HIGHLAND SERIES

27 | P a g e © Adam Equipment Company 2011 ...

[Page 30] Adam Equipment HIGHLAND SERIES

28 | P a g e © Adam Equipment Company 2011 10.0 CALIBRATION CERTIFICATE 11.0 WARRANTY STATEMENT Adam Equipment offers Limited Warranty (Parts and Labor) for the components failed due to defects in materials or workmanship...

[Page 31] Adam Equipment HIGHLAND SERIES

29 | P a g e © Adam Equipment Company 2011 Manufacturer’s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards, following the provisions of the below st...