[Page 1] Carson SC-1002

Carson Manufacturing Co., Inc. 5451 North Rural Street Indianapolis, IN 46220 Phone: (888) 577-6877 Fax: (317) 254-2667 www.carsonsirens.com SC-1002 / 1012 / 1022-10 Ver. B SIREN AMPLIFIER W/ LIGHT CONTROL Ver. B has diffe...

[Page 2] Carson SC-1002

Page 2 of 16 SC-1002 / 1012 / 1022-10 Ver. B Installation Instructions 03/11/10 CP5028A TABLE OF CONTENTS GENERAL DESCRIPTION .................................................................................... 3 SPECIFICATIONS..............

[Page 3] Carson SC-1002

SC-1002 / 1012 / 1022-10 Ver. B Installation Instructions Page 3 of 16 CP5028A 03/11/10 GENERAL DESCRIPTION The SC-1000 Series Siren Amplifier with Light Control is designed for single 100W speaker use. The SC-1002 and SC-1012 are a conso...

[Page 4] Carson SC-1002

Page 4 of 16 SC-1002 / 1012 / 1022-10 Ver. B Installation Instructions 03/11/10 CP5028A INSTALLATION Proper installation of the unit is essential for years of safe, reliable operation. Please read all instruction before installing the un...

[Page 5] Carson SC-1002

SC-1002 / 1012 / 1022-10 Ver. B Installation Instructions Page 5 of 16 CP5028A 03/11/10 OPTION SWITCHES An internal 8-position DIP switch on the circuit board may be changed to select various options. Accessing Option Switches - the DIP s...

[Page 6] Carson SC-1002

Page 6 of 16 SC-1002 / 1012 / 1022-10 Ver. B Installation Instructions 03/11/10 CP5028A MOUNTING (Main unit) The mounting bracket supplied can be installed above or below the unit. Mounting bolts slide into channels on each side of the...

[Page 7] Carson SC-1002

SC-1002 / 1012 / 1022-10 Ver. B Installation Instructions Page 7 of 16 CP5028A 03/11/10 ELECTRICAL CONNECTIONS Electrical connections to the unit are made using terminal block plugs and screw terminals located on the amplifier. Labels on t...

[Page 8] Carson SC-1002

Page 8 of 16 SC-1002 / 1012 / 1022-10 Ver. B Installation Instructions 03/11/10 CP5028A ELECTRICAL CONNECTIONS CONTINUED (ALL MODELS) BAT + - Plug installed this orientation 6-P Terminal Block Plug (CP4956-06) RED #16G BLK #18G BR...

[Page 9] Carson SC-1002

SC-1002 / 1012 / 1022-10 Ver. B Installation Instructions Page 9 of 16 CP5028A 03/11/10 ELECTRICAL CONNECTIONS CONTINUED (SC-1012 only) Plug installed this orientation 10-P Terminal Block Plug (CP4688-10) Front of Unit LT1 and LT2 Li...

[Page 10] Carson SC-1002

Page 10 of 16 SC-1002 / 1012 / 1022-10 Ver. B Installation Instructions 03/11/10 CP5028A ELECTRICAL CONNECTIONS CONTINUED (SC-1022 only) Front of Unit HAND CONTROL Plug hand control into unit SC-1022 MAN LT1 MECH YELP HORN LT2 WAIL PHS...

[Page 11] Carson SC-1002

SC-1002 / 1012 / 1022-10 Ver. B Installation Instructions Page 11 of 16 CP5028A 03/11/10 OPERATION SC-1002 and SC-1012 Models POWER ON/OFF The unit is turned on with the siren or light controls or the ignition switch on the vehicle. See I...

[Page 12] Carson SC-1002

Page 12 of 16 SC-1002 / 1012 / 1022-10 Ver. B Installation Instructions 03/11/10 CP5028A OPERATION (SC-1002 and SC-1012 Models continued) LIGHT CONTROLS LT1 and LT2 LIGHTED ROCKER SWITCHES When turned on the rocker switch will light up a...

[Page 13] Carson SC-1002

SC-1002 / 1012 / 1022-10 Ver. B Installation Instructions Page 13 of 16 CP5028A 03/11/10 OPERATION (continued) SC-1022 Model POWER ON/OFF The unit is normally turned on with ignition switch on the vehicle. See INSTALLATION section. The...

[Page 14] Carson SC-1002

Page 14 of 16 SC-1002 / 1012 / 1022-10 Ver. B Installation Instructions 03/11/10 CP5028A SERVICE This unit is designed to provide years of reliable service under even the worst conditions. Many times there may appear to be a problem with...

[Page 15] Carson SC-1002

SC-1002 / 1012 / 1022-10 Ver. B Installation Instructions Page 15 of 16 CP5028A 03/11/10 PARTS and ACCESSORIES The following parts and accessories are available from Carson Manufacturing Company, Inc.: See www.carsonsirens.com for add...

[Page 16] Carson SC-1002

Page 16 of 16 SC-1002 / 1012 / 1022-10 Ver. B Installation Instructions 03/11/10 CP5028A RETURN If you have any questions concerning this or any other Carson product, please contact our Technical Service Department at (888) 577-68...