Furuno DFF1-UHD Operator's Manual

Download or browse on-line these Operator's Manual for Furuno DFF1-UHD Fish Finder.

Furuno DFF1-UHD Manual Information:

This manual for Furuno DFF1-UHD, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 40 pages, and the size of the file at download is . The document type is Operator's Manual.

Download Manual

More Manuals:

In case you failed to obtain relevant information in this document, please, look through related operating manuals and user instructions for Furuno DFF1-UHD. Just click one of the links below to go to the selected manual:

Summary of Contents:

[Page 1] Furuno DFF1-UHD

NETWORK FISH FINDER DFF1-UHD OPERATOR'S MANUAL www.furuno.com Model ...

[Page 2] Furuno DFF1-UHD

...

[Page 3] Furuno DFF1-UHD

i IMPORTANT NOTICES General • This manual has been authored with simplified grammar, to meet the needs of international users. • The operator of this equipment must read and follow the descriptions in this manual. Wrong operation or maintenance...

[Page 4] Furuno DFF1-UHD

ii SAFETY INSTRUCTIONS Do not operate the equipment with wet hands. Electrical shock can result. Do not place liquid-filled containers on the top of the equipment. Electrical shock can result. Do not install the equipment where it may be subjected ...

[Page 5] Furuno DFF1-UHD

SAFETY INSTRUCTIONS iii Standard compass Steering compass 1.00 m 0.60 m CAUTION CAUTION The transducer cable must be handled carefully, following the guidelines below. • Keep fuels and oils away from the cable. • Locate the ca...

[Page 6] Furuno DFF1-UHD

iv TABLE OF CONTENTS FOREWORD ....................................................................................................................v SYSTEM CONFIGURATION ....................................................................................

[Page 7] Furuno DFF1-UHD

v FOREWORD A Word to the Owner of the DFF1-UHD Congratulations on your choice of the FURUNO DFF1-UHD Network Fish Finder. We are confi- dent you will see why the FURUNO name has become synonymous with quality and reliability. Since 1948, FURUNO Elect...

[Page 8] Furuno DFF1-UHD

vi SYSTEM CONFIGURATION 100/110/ 220/230 VAC 1ø, 50/60 Hz NETWORK FISH FINDER DFF1-UHD 12-24 VDC Transducer Rectifier PR-62 Speed/Temperature Sensor ST-02MSB ST-02PSB Temperature Sensor T-02MTB T-02MSB T-03MSB NavNet Equipment TZT9/14/BB B265LH or C...

[Page 9] Furuno DFF1-UHD

1 1. INSTALLATION 1.1 Equipment Lists Standard supply Optional supply Name Type Code No. Qty Remarks Network Fish Finder DFF1-UHD — 1 Spare Parts SP02-05601 001-033-740 1 set Fuse (2 pcs.) Installation Materials CP02-08500 000-011-917 1 set - Power...

[Page 10] Furuno DFF1-UHD

1. INSTALLATION 2 1.2 Network Fish Finder The network fish finder can be installed on a desktop, deck or on a bulkhead. When selecting a mounting location, keep the following points in mind: • The temperature and humidity at the mounting site sh...

[Page 11] Furuno DFF1-UHD

1. INSTALLATION 3 1.3 Transducer The performance of the fish finder largely depends upon the transducer position. Select a place least affected by air bubbles since turbulence blocks the sounding path. The face of the transducer must be facing the...

[Page 12] Furuno DFF1-UHD

1. INSTALLATION 4 1.5 Optional Temperature Sensors 1.5.1 Transom mount temperature sensor T-02MTB • Fix the cable at a convenient location with cable clamp. • When the cable is led in through the transom board, make a hole of approx. 17 mm in ...

[Page 13] Furuno DFF1-UHD

1. INSTALLATION 5 1.5.2 Thru-hull temperature sensor T-02MSB, T-03MSB Select a suitable mounting location considering the following points. • Select a mid-boat flat position. The sensor does not have to be installed perfectly perpendicular. Howe...

[Page 14] Furuno DFF1-UHD

6 2. WIRING 2.1 Wiring Outline Connect the power cable, transducer cables, sensor cable, network cable and ground wire to their respective locations on the network sounder. See the next page for how to connect the transducer cables. Ground Connect ...

[Page 15] Furuno DFF1-UHD

2. WIRING 7 2.2 Transducer Cable, Cable for External KP (option) If the external KP is not to be connected, do only the applicable procedures in sections 2.2.1 and 2.2.2. The KP from an echo sounder or sonar can be connected to this network fish fi...

[Page 16] Furuno DFF1-UHD

2. WIRING 8 How to process the cable for the external KP 1. Process the PH connector (02-1097, optional supply) as shown below. a) Make the length of the wires of the PH connector 100 mm. b) Remove the sheath from the cores 10 mm. c) Fold back the c...

[Page 17] Furuno DFF1-UHD

2. WIRING 9 2.2.2 How to connect the transducer cable This procedure shows you how to connect the transducer cable. To connect both the transducer cable and the cable for external KP, go to section 2.2.3. 1. Open the cover: Grasp the cover at two s...

[Page 18] Furuno DFF1-UHD

2. WIRING 10 5. Loosen the two screws fixing the clamp fixing plate to detach the plate. 6. Pass the sealing nut (unfastened at step 4) onto the transducer cable and pass the cable through the super gland and into the unit. 7. Use the WAGO connecto...

[Page 19] Furuno DFF1-UHD

2. WIRING 11 10. Tighten the sealing nut according to the information in the table below. 11. Reattach the shield cover and close the outer cover. 2.2.3 How to connect the transducer cable, cable for external KP 1. Remove the cover, shield cover and...

[Page 20] Furuno DFF1-UHD

2. WIRING 12 6. Unfasten the nut material inside the unit. 7. Using the two screws removed at step 5, fasten the upper two holes of the supplied rainproof- ing panel. Nut material Rainproofing panel Clamp Clamp fixing plate Rainproofing panel (supp...

[Page 21] Furuno DFF1-UHD

2. WIRING 13 8. TIghten the lock nut inside the unit to fasten the super glands (two pcs., see step 12). The torque for the lock nut shall be 1.8 - 2.0 N/m. 9. Set the nut material (removed at step 6) inside the unit, align its two protrusions with...

[Page 22] Furuno DFF1-UHD

2. WIRING 14 11. For the transducer cable and the cable for the external KP, pass each cable through its super gland, the supplied rainproofing panel and each hole in the unit. Then slip a lock nut onto each cable. (For the super gland of the cabl...

[Page 23] Furuno DFF1-UHD

2. WIRING 15 12. Transducer cable: Lay the transducer cable in the cable clamp then refasten the clamp fixing plate. Cable for the external KP: Lay the cable in the cable clamp and fix it with the supplied clamp fixing plate and two upset screws. ...

[Page 24] Furuno DFF1-UHD

2. WIRING 16 14. Attach the supplied EMI core (GRFC-10) to the cable for the external KP approx. 100 mm from the super gland. 15. Attach the shield cover and close the outer cover. Super gland (for ext. KP) EMI core 10 mm ...

[Page 25] Furuno DFF1-UHD

2. WIRING 17 2.3 LAN Cable Do as follows to connect the supplied LAN cable (MOD-Z072-050+) or the optional LAN cable (MOD-Z072-020+, MOD-Z072-100+). 1. Unfasten the sealing nut from the LAN connector then remove the sealing insert and clamping cla...

[Page 26] Furuno DFF1-UHD

2. WIRING 18 3. Pass the sealing nut, clamping claw and sealing insert onto the LAN cable in the order shown in the figure below. Connect the cable to the LAN connector. (Note the orientation of the seal- ing insert when passing it onto the cable. ...

[Page 27] Furuno DFF1-UHD

19 3. INITIAL SETTINGS 3.1 DIP Switch Setting The DIP switch S2 sets up the system according to the equipment connected. In the default setting all switches (1-8) are OFF. The DIP switch S3 should not be adjusted; leave all switches in the OFF posi...

[Page 28] Furuno DFF1-UHD

3. INITIAL SETTINGS 20 After setting up the transducer at the DFF1-UHD, set the transducer type at the NavNet device. See respective Installation Manual for the procedure. Note: DIP Switch S2 is for factory use. Do not change the settings. 3.2 Oper...

[Page 29] Furuno DFF1-UHD

21 4. MAINTENANCE 4.1 Maintenance Regular maintenance is essential for good performance. Check the items listed in the table below at the suggested interval to help keep your equipment in good shape for years to come. Item Check point, action Check ...

[Page 30] Furuno DFF1-UHD

4. MAINTENANCE 22 4.2 How to Replace the Fuse The 5A fuse (Type: FGBO-A 125V 5A PBF, Code No. 000-155-853-10) in the snap-in fuse holder on the power cable protects the equipment from equipment fault and reverse polarity of the power supply. If th...

[Page 31] Furuno DFF1-UHD

AP-1 APPENDIX 1 JIS CABLE GUIDE EX: DPYCYSLA - 1.5 MPYC - 4 Core Cable Core Cable Type Area Diameter ...

[Page 32] Furuno DFF1-UHD

FURUNO DFF1-UHD SP - 1 E2040S01A 121203 SPECIFICATIONS OF NETWORK FISH FINDER DFF1-UHD 1 GENERAL 1.1 TX frequency 50/200 kHz, alternative transmission 1.2 Output power 1 kW nominal 1.3 Amplifier type Straight amplifier (H/L gai...

[Page 33] Furuno DFF1-UHD

PACKING LIST 02GL-X-9851 -0 DFF1-UHD N A M E O U T L I N E DESCRIPTION/CODE № Q'TY 1/1 ユニット UNIT ネットワーク魚探 NETWORK FISH FINDER DFF1-UHD 000-022-520-00 1 予備品 SPARE PARTS SP02-05601 ヒュー...

[Page 34] Furuno DFF1-UHD

...

[Page 35] Furuno DFF1-UHD

2 43 A 1 B C DRAWN CHECKED APPROVED DWG.No. TITLE NAME 名称 INTERCONNECTION DIAGRAM 相互結線図 REF.No. SCALE MASS kg T.YAMASAKI DFF1-UHD ネットワーク魚探 H.MAKI 1 2 3 (+) (-) SHIELD J1 1B 2 02P6385 1 2 3 4 1 1 2 3 4 5 6 7 8 2 3 4 5 TB3...

[Page 36] Furuno DFF1-UHD

FURUNO Worldwide Warranty for Pleasure Boats (Except North America) This warranty is valid for products manufactured by Furuno Electric Co. (hereafter FURUNO) and installed on a pleasure boat. Any web based purchases that are imported into other...

[Page 37] Furuno DFF1-UHD

FURUNO Warranty for North America FURUNO U.S.A., Limited Warranty provides a twenty-four (24) months LABOR and twenty-four (24) months PARTS warranty on products from the date of installation or purchase by the original owner. Products or compone...

[Page 38] Furuno DFF1-UHD

...

[Page 39] Furuno DFF1-UHD

...

[Page 40] Furuno DFF1-UHD

FURUNO Authorized Distributor/Dealer Printed in Japan (Elemental Chlorine Free) The paper used in this manual is elemental chlorine free. 9-52, Ashihara-cho, Nishinomiya, 662-8580, JAPAN All rights reserved. Pub. No. OME-20400-B (DAMI) DFF1-UH...