[Page 1] Teledyne 2105

2105/2105Ci/Gi Interface Module Installation and Operation Guide Part #69-2003-635 of Assembly #60-2004-635 Copyright © 2011. All rights reserved, Teledyne Instruments, Inc. Revision C, August 2013 ...

[Page 2] Teledyne 2105

...

[Page 3] Teledyne 2105

Foreword This instruction manual is designed to help you gain a thorough understanding of the operation of the equipment. Teledyne Isco recommends that you read this manual completely before placing the equipment in service. Although Teledyne Isco de...

[Page 4] Teledyne 2105

...

[Page 5] Teledyne 2105

2105 Interface Module Safety iii 2105 Interface Modul e Safety General Warnings Before installing, operating, or maintaining this equipment, it is imperative that all hazards and preventive measures are fully understood. While specific hazards may va...

[Page 6] Teledyne 2105

2105 Interface Module Safety iv Hazard Symbols The equipment and this manual use symbols used to warn of hazards. The symbols are explained below. Hazard Symbols Warnings and Cautions The exclamation point within the triangle is a warning sign alerti...

[Page 7] Teledyne 2105

v 2105 Interface Module Table of Contents Section 1 Introduction 1.1 Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.2 2105 Module Components. . . . . . . . . . . . . . . ....

[Page 8] Teledyne 2105

2105 Interface Module Table of Contents vi 4.1.1 Data Retrieval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 4.1.2 Text Messaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

[Page 9] Teledyne 2105

2105 Interface Module Table of Contents vii 1-4 Battery Module Components, Bottom View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 1-5 Specification drawing: 2105 (larger width for cellular modules) . . . . . . . . . . . . . . ...

[Page 10] Teledyne 2105

2105 Interface Module Table of Contents viii 2-3 4200/6700 Series Supported Data Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-30 2-4 2105 Port Connector Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

[Page 11] Teledyne 2105

1-1 2105 Interface Module Section 1 Introduction This instruction manual is designed to help you gain a thorough understanding of the operation of the 2105, 2105Ci, and 2105Gi Interface Modules. Teledyne Isco recommends that you read this manual comp...

[Page 12] Teledyne 2105

2105 Interface Module Section 1 Introduction 1-2 1.2 2105 Module Components Figures 1-1 and 1-2 identify the key components of the 2105 Interface Module. Figure 1-1 2105 Components - Top View 11 2 2 3 3 4 4 5 5 6 7 8 8 2105 Module Cellular Modem ...

[Page 13] Teledyne 2105

2105 Interface Module Section 1 Introduction 1-3 Figure 1-2 2105 Components - Bottom View 1 2 4 3 5 6 Table 1-2 2105 Interface Module Components - Bottom View Item No. Name Description 1 Communication and Power Connector This connects the 2105 to...

[Page 14] Teledyne 2105

2105 Interface Module Section 1 Introduction 1-4 1.3 Battery Module Components Figures 1-3 and 1-4 identify key components of the 2191 Battery Module. Figure 1-3 Battery module components, top view 1 2 3 4 5 Table 1-3 Battery Module Components -...

[Page 15] Teledyne 2105

2105 Interface Module Section 1 Introduction 1-5 Figure 1-4 Battery Module Components, Bottom View 2 1 3 4 Table 1-4 Battery Module Components - Bottom View Item No. Name Description 1 Communication Connector Connects the modules in the stack, tr...

[Page 16] Teledyne 2105

2105 Interface Module Section 1 Introduction 1-6 1.4 Technical Specifications Technical specifications for the 2105 Interface Module are given in Table 1-5. Technical specifications for the 2191 Battery Module are given in Table 1-6. Following the ...

[Page 17] Teledyne 2105

2105 Interface Module Section 1 Introduction 1-7 Figure 1-5 Specification drawing: 2105 (larger width for cellular modules) Table 1-6 Technical Specifications: 2191 Battery Module Dimensions (H x W x D) 6.0 x 9.6 x 7.5 in. 15.2 x 24.4 x 19.1 cm Wei...

[Page 18] Teledyne 2105

2105 Interface Module Section 1 Introduction 1-8 Figure 1-6 Specification drawing: 2105 mounted on 2191 battery module Antenna Connector Cellular Only 2105Ci/Gi 2105 ...

[Page 19] Teledyne 2105

2105 Interface Module Section 1 Introduction 1-9 1.5 Safety Symbols and Hazard Alerts This icon identifies a general hazard and is accompanied with details about the hazard. The instruction manual identifies the hazardous condition and any steps ne...

[Page 20] Teledyne 2105

2105 Interface Module Section 1 Introduction 1-10 1.6 Technical Service Although Teledyne Isco designs reliability into all of its equipment, you can use this manual to help in diagnosing and resolving many issues. If a problem persists, call or wri...

[Page 21] Teledyne 2105

2-1 2105 Interface Module Section 2 Installation and Operation 2.1 Unpacking Instructions When the system arrives, inspect the contents for any damage. If there is damage, contact the delivery company and Teledyne Isco (or its agent) immediately. W...

[Page 22] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-2 Figure 2-1 Identifying the 2150 voltage specification Table 2-1 Voltage Specifications for 2100 System Components Module or Cable Earlier Voltage Range Current Voltage Range Updated 2150...

[Page 23] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-3 The module crown connector on the earlier RS-232 DB9 digital communication cable is unmarked. The connector on the 26-volt cable has a serial tag specifying the higher voltage (Figure 2-...

[Page 24] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-4 WARNING The installation and use of this product may subject you to hazardous working conditions that can cause you serious or fatal injuries. Take any necessary precautions before ...

[Page 25] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-5 Latches will “click” when they are fully locked or unlocked. Figure 2-4 Locking the latch 2.3.2 Communication Connectors When a communication connector is not in use, the con- necto...

[Page 26] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-6 2.3.3 Installing the Batteries The 2191 battery module requires two lantern batteries. The figures below show a 6 VDC alkaline battery. Rechargeable 6 VDC lead-acid batteries are also av...

[Page 27] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-7 2.4 Stacking Modules The 2105 can be located anywhere within a stack of up to four 2100 Series networked modules. It will draw its power from the same source as the rest of the stack. T...

[Page 28] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-8 2.5 Connecting to Flowlink Once the system is installed, you will configure it in a new or existing site using Isco’s Flowlink software. Note The 2105 and 2105Ci/Gi Modules require...

[Page 29] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-9 To add the new module to an existing site, select the appropriate site and click OK. To create a new site, select Create a New Site. Click in the name field, enter the name for the site,...

[Page 30] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-10 Figure 2-10 Site Information screen ...

[Page 31] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-11 When the module has been added to the system, you will see the Devices screen. Figure 2-11 Devices screen - connected to site This window displays all of the modules connected to the si...

[Page 32] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-12 2.5.1 Modem Site Connection To begin using the 2105’s cellular modem, you must set up the modem’s operation on the Modem screen. The digital cellular modem provides Serial Over IP ...

[Page 33] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-13 Connection Information for the site is set up on the Devices screen. Click the Disconnect button to activate the fields. Serial over IP connection To set up a serial-over-IP connection,...

[Page 34] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-14 2.6 Power Conservation (cellular modules) If you are using a cellular module, you may want to conserve battery power by setting up a Power Control method using the equation builder. Ra...

[Page 35] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-15 2.7 Setting Up Text Alarms (cellular modules) The 2105Ci/Gi is capable of digital text messaging to up to 5 text capable cellular phones when a programmed alarm condition occurs. To p...

[Page 36] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-16 3. In the Phone Number list box, type the contact telephone numbers. These must be valid SMS phone numbers. You must enter at least one number; you can enter as many as five. When an...

[Page 37] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-17 2.8 Pushed Data Capability (cellular modules) The 2105Ci/Gi can automatically send data to a designated server running Isco Flowlink Pro software. The user-specified primary data trans...

[Page 38] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-18 Detailed Flowlink instructions are beyond the scope of this manual. Flowlink’s operating instructions are available in a Windows Help format. You can access the Help topics for an act...

[Page 39] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-19 2.10 Rain Gauge Interface The 2105 will log rainfall data, and can enable a connected Teledyne Isco water sampler based on a rain event (see 2.11 Sampler Interface). For more informatio...

[Page 40] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-20 2.11 Sampler Interface The 2105 can control a connected Teledyne Isco wastewater sampler. Two interconnect ‘Y’ cables are available: one for the 4700 refrigerated sampler, and one f...

[Page 41] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-21 To record sample events and bottle numbers, select Set Up Data Storage... on the Sampler tab. In the Data Storage Setup window (Figure 2-20), select the check box next to Enable Logging...

[Page 42] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-22 visit the site and cycle the power to restore wireless communi- cations. To use this feature, two cables are required (Figure 2-21). You will need the 2105-to-sampler ‘Y’ cable, and...

[Page 43] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-23 On the Connect screen, click Modify and enter phone number of the site you want to access and select the Settings tab (Figure 2-23). Figure 2-23 Specifying the connection number From th...

[Page 44] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-24 The Connect window will reappear. Figure 2-25 HyperTerminal connect window To begin communication to your sampler, Click Dial. The PC will call and connect to the 2105. Once connected, ...

[Page 45] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-25 2.13 Pulse Doppler Devices The 2105 can receive flow data (QMain, Velocity, and Depth) from a connected Pulse Doppler device, including the standard depth ADFM, the H-ADFM (large channe...

[Page 46] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-26 2.14 Modbus Input The 2105 module is capable of receiving data from devices using Modbus ASCII or Modbus RTU protocol. The 2105 Modbus input function supports ASCII and RTU pro- tocols,...

[Page 47] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-27 The information entered in the configuration window will be determined by the characteristics of your particular system. Select the device’s Modbus address, between 1 and 247. Enter a...

[Page 48] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-28 Enter a name for the parameter, and the number of the device’s register holding the data. The data format will depend on the output of the connected device. The units of measure avail...

[Page 49] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-29 Activating 4200 Serial Output To activate the serial output function: 1. Go into the 4200 Set Up screen. 2. Use the arrow key to arrow to Optional Outputs. 3. Select the Serial Output ...

[Page 50] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-30 Note The Data Command Field column in Table 2-3 refers to serial data identifiers used in remote operation. For consistency, you may wish to use the identifier for the Parameter Name....

[Page 51] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-31 57 YSI flow rate Cubic meters per second YFL 59 YSI flow volume Cubic meters YVO 61 Sampler Enable Status Logical SS 63 Velocity Meters per second VE 65 Velocity Signal Percent VSI 67 ...

[Page 52] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-32 121 Level Meters LE1 123 Ammonium-nitrogen Milligrams nitrogen per liter MM1 125 Ammonia-nitrogen Milligrams nitrogen per liter MA1 127 Nitrate-Nitrogen Milligrams nitrogen per liter NI...

[Page 53] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-33 (N *34)+81 Total Dissolved Solids Grams per liter TDN (N *34)+83 Temperature Degrees Celsius TEN (N *34)+85 Oxidation reduction Potential millivolts ORN (N *34)+87 Level Meters LEN (N *...

[Page 54] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-34 2.15 Cables A variety of interfacing cables are available for use with the 2105 module. Figure 2-30 briefly describes the purpose of each cable. Depending on your configuration, a syste...

[Page 55] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-35 2.16 2105 Universal Cable This multipurpose cable connects to the 12-pin female connector on the side of the 2105 module. The non-terminated end can be wired to compatible circuits for ...

[Page 56] Teledyne 2105

2105 Interface Module Section 2 Installation and Operation 2-36 Table 2-4 2105 Port Connector Functions a Pin Wire Color Functionality Default Configuration Additional Information A - SDI-12A Brown SDI-12 Data SDI-12 Data Master Transmits/Receives ...

[Page 57] Teledyne 2105

3-1 2105 Interface Module Section 3 2105Ci Cellular Modem Module 3.1 Overview The 2105Ci Modem Module contains a cellular modem equipped with Code Division Multiple Access (CDMA) technology. The 2105Ci has 1xRTT capability where this service is avail...

[Page 58] Teledyne 2105

2105 Interface Module Section 3 2105Ci Cellular Modem Module 3-2 3.1.5 2105Ci Label Information You should record the IP address, printed on the serial label on the back of the case (Figure 2-1). You will need this information when you configure th...

[Page 59] Teledyne 2105

4-1 2105 Interface Module Section 4 2105Gi Cellular Modem Module 4.1 Overview The 2105Gi Modem Module contains a cellular modem equipped with Global System Mobile (GSM) communication technology, with GPRS service capability. After the module is insta...

[Page 60] Teledyne 2105

2105 Interface Module Section 4 2105Gi Cellular Modem Module 4-2 Figure 4-1 Accessing the SIM card on the bottom of the module The SIM card is held in the slot in the modem with a small switch. To remove or insert the card, push the switch into the ...

[Page 61] Teledyne 2105

2105 Interface Module Section 4 2105Gi Cellular Modem Module 4-3 Inserting the SIM card is made easier by propping the module in a vertical position. Press the card, oriented as shown below, into the spring-loaded slot until it “clicks” in place...

[Page 62] Teledyne 2105

2105 Interface Module Section 4 2105Gi Cellular Modem Module 4-4 4.3 Antenna Options One of three antenna types is included with your system, spec- ified when ordering: the magnetic mount antenna, the in-street antenna, or the manhole lid-mount ante...

[Page 63] Teledyne 2105

2105 Interface Module Section 4 2105Gi Cellular Modem Module 4-5 4.3.3 Manhole Lid-Mount Antenna This antenna is 6 inches in diameter and 0.705 inches tall (4.575 inches tall with manhole and mounting shank included) With a 10-foot cable. A hole is...

[Page 64] Teledyne 2105

2105 Interface Module Section 4 2105Gi Cellular Modem Module 4-6 ...

[Page 65] Teledyne 2105

5-1 2105 Interface Module Section 5 Modbus Protocol and 2100 Output Sections 5.1 through 5.5 give an overview of the basic capabilities and operation of Modbus protocol as it applies to Isco 2100 Series flow modules. For a Glossary of Terms and Commo...

[Page 66] Teledyne 2105

2105 Interface Module Section 5 Modbus Protocol and 2100 Output 5-2 By accessing these registers you can obtain the current value of whatever parameter you desire. The reading(s) can then be dis- played or stored wherever you designate as a destinat...

[Page 67] Teledyne 2105

2105 Interface Module Section 5 Modbus Protocol and 2100 Output 5-3 Each module capable of Modbus Protocol communication will automatically create its own specific ASCII address within the site, using: • The model numbers of the modules • The us...

[Page 68] Teledyne 2105

2105 Interface Module Section 5 Modbus Protocol and 2100 Output 5-4 The operation sequence for the example above can be summa- rized in the following steps: 2150: 1. 2150s take readings from probes. 2. 2150s store readings (level, velocity, flow rat...

[Page 69] Teledyne 2105

2105 Interface Module Section 5 Modbus Protocol and 2100 Output 5-5 SCADA – SCADA (Supervisory Control And Data Acquisition) is a computer system for gathering and analyzing real-time data. SCADA systems are used to monitor and control plant opera...

[Page 70] Teledyne 2105

2105 Interface Module Section 5 Modbus Protocol and 2100 Output 5-6 The Modbus registers are assigned within 30 seconds after the 2100 module is powered up. To conserve power for the users who do not use Modbus communications, no Modbus registers wi...

[Page 71] Teledyne 2105

6-1 2105 Interface Module Section 6 Maintenance 6.1 Overview The 2105 is designed to perform reliably in adverse conditions with a minimal amount of routine service requirements. To keep your system working properly, you should check the desiccant an...

[Page 72] Teledyne 2105

2105 Interface Module Section 6 Maintenance 6-2 6.2.1 Replacing the Desiccant The desiccant is contained in a cartridge located on the side of the 2105. To remove the cartridge, unscrew the collar and slide the cartridge out of the 2105. The clear ...

[Page 73] Teledyne 2105

2105 Interface Module Section 6 Maintenance 6-3 6.3 Hydrophobic Filter If the 2105 is in a humid location or submerged, a hydrophobic filter prevents water from entering the desiccant cartridge. Any amount of water will plug the filter and it must b...

[Page 74] Teledyne 2105

2105 Interface Module Section 6 Maintenance 6-4 ...

[Page 75] Teledyne 2105

A-1 2105 Interface Module Appendix A Replacement Parts List A.1 Replacement Parts Diagrams and Listings Replacement parts are called out in illustrations in this section. Reference the call-outs in the accompanying tables to determine the part numb...

[Page 76] Teledyne 2105

2105 Interface Module Appendix A Replacement Parts List A-2 A.2 2105/Ci/Gi Module ...

[Page 77] Teledyne 2105

2105 Interface Module Appendix A Replacement Parts List A-3 ...

[Page 78] Teledyne 2105

2105 Interface Module Appendix A Replacement Parts List A-4 ...

[Page 79] Teledyne 2105

2105 Interface Module Appendix A Replacement Parts List A-5 ...

[Page 80] Teledyne 2105

2105 Interface Module Appendix A Replacement Parts List A-6 ...

[Page 81] Teledyne 2105

2105 Interface Module Appendix A Replacement Parts List A-7 Page intentionally left blank. ...

[Page 82] Teledyne 2105

2105 Interface Module Appendix A Replacement Parts List A-8 A.3 2105 Ci Magnetic Mount Antenna ...

[Page 83] Teledyne 2105

2105 Interface Module Appendix A Replacement Parts List A-9 ...

[Page 84] Teledyne 2105

2105 Interface Module Appendix A Replacement Parts List A-10 A.4 2105Gi Magnetic Mount Antenna ...

[Page 85] Teledyne 2105

2105 Interface Module Appendix A Replacement Parts List A-11 ...

[Page 86] Teledyne 2105

2105 Interface Module Appendix A Replacement Parts List A-12 A.5 2105Ci/Gi In-Street Antenna ...

[Page 87] Teledyne 2105

2105 Interface Module Appendix A Replacement Parts List A-13 ...

[Page 88] Teledyne 2105

2105 Interface Module Appendix A Replacement Parts List A-14 A.6 2191 Battery Module ...

[Page 89] Teledyne 2105

2105 Interface Module Appendix A Replacement Parts List A-15 ...

[Page 90] Teledyne 2105

2105 Interface Module Appendix A Replacement Parts List A-16 ...

[Page 91] Teledyne 2105

B-1 2105 Interface Module Appendix B Accessories B.1 How to Order Accessories can be purchased by contacting Teledyne Isco’s Cus- tomer Service Department. Teledyne Isco Customer Service Dept. P.O. Box 82531 Lincoln, NE 68501 USA Phone: (800) 22...

[Page 92] Teledyne 2105

2105 Interface Module Appendix B Accessories B-2 B.3 Cables Power adaptor cable for Isco batteries and power packs, 2 ft standard, CE-rated . . . . . . . . . . . . . 69-2004-451 RS232 Interrogator Cable . . . . . . . . . . . . . . . . . . . . . . 60...

[Page 93] Teledyne 2105

C-1 2105 Interface Module Appendix C Material Safety Data Sheets This appendix to the manual provides Material Safety Data Sheets for the desiccant used by the 2105 Module. Teledyne Isco cannot guarantee the accuracy of the data. Specific questions ...

[Page 94] Teledyne 2105

2105 Interface Module Appendix C Material Safety Data Sheets C-2 MATERIAL SAFETY DATA SHEET Effective Date March 8, 2005 MSDS Number M163 Section 1  Product and Company Informa...

[Page 95] Teledyne 2105

2105 Interface Module Appendix C Material Safety Data Sheets C-3 Section 4  First Aid Measures Eyes: Rinse the eyes well with water while lifting the eye lids. If irritation persists, consult a physician. Skin: Wash affected area...

[Page 96] Teledyne 2105

2105 Interface Module Appendix C Material Safety Data Sheets C-4 Section 8  Exposure Controls/Personal Protection Engineering Controls: Use exhaust ventilation to keep the airborne concentrations below the exposure limits. Respira...

[Page 97] Teledyne 2105

2105 Interface Module Appendix C Material Safety Data Sheets C-5 Section 11  Toxicological Information This product and its components are not listed on the NTP or OSHA Carcinogen lists. Animal Toxicology Tests for DOT Hazard classifi...

[Page 98] Teledyne 2105

2105 Interface Module Appendix C Material Safety Data Sheets C-6 ...

[Page 99] Teledyne 2105

Index-1 2105 Interface Module Index Numerics 2105 universal cable, 2-35 4200/6700 data input, 2-28 A accessories, B-1 ADFM flow meters, 2-25 alarms, 2-15 antenna options 2105Ci, 3-2 2105Gi, 4-4 B battery module batteries, 2-6 components, 1-4 C cables...

[Page 100] Teledyne 2105

2105 Interface Module Index Index-2 S safety information, 1-9, C-1 system power, 2-1 sampler "Pass Thru" mode, 2-21 sampler interface, 2-20 SDI-12 input, 2-18 service, 6-3 sondes, 2-18 specifications, 1-6 stacking, 2-7 T TCP connection, 2-1...