JW Fishers PULSE 12 Operation Manual

Download or browse on-line these Operation Manual for JW Fishers PULSE 12 Radar Detector.

JW Fishers PULSE 12 Manual Information:

This manual for JW Fishers PULSE 12, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 8 pages, and the size of the file at download is . The document type is Operation Manual.

Download Manual

Summary of Contents:

[Page 1] JW Fishers PULSE 12

PULSE 12 BOAT TOWED PULSE DETECTOR OPERATION MANUAL 1009 JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA 02718 USA (508) 822-7330; (800) 822-4744; FAX (508) 880-8949 Email: [email protected] WEB: www.jwfishers.com ...

[Page 2] JW Fishers PULSE 12

SENSITIVITY ( see page 3 for details ): i SPECIFICATIONS Sensitivity (in water): Fresh Salt Sample Pulse Delay 0 0 5 • Piece of eight ............................... 17 in ................. 9 in. ... 4 in. • 25 lb. lead ingot ..................

[Page 3] JW Fishers PULSE 12

INTRODUCTION The PULSE 12 is a boat-towed pulse induction metal detector. Though it was primarily designed to locate large metal objects, it will detect small targets though not at great distances. Pulse detectors have been around since the mid 1970&...

[Page 4] JW Fishers PULSE 12

PULSE 12 DESCRIPTION The PULSE 12 is a boat-towed pulse detector consisting of an 24" by 36" Coil, a towable Fish (removable for land use), a Pre-amp, a 150/300' Cable, and a Control Box. The Control Box can support one, two, or three ...

[Page 5] JW Fishers PULSE 12

BATTERY SELECTION The PULSE 12 draws approximately .3 amp at 24v. Two car type batteries will last several days of continuous use. For good portability, two motorcycle type batteries can be used, with a minimum of 8 hours between charges. Battery s...

[Page 6] JW Fishers PULSE 12

GAL CAN 4' MAX RANGE 14' DRAWN TO SCALE DETECTION AREA FOR SINGLE COIL 6' 21' MAX DETECTION ENVELOPE ( salt water ) 4 PULSE 12 ASSEMBLY ( coil and fish ) Note: All hardware must be of stainless steel. Stain...

[Page 7] JW Fishers PULSE 12

- Turn the Selection Switch for all unused Fish to the Off position. - Push the Batt. Ck. momentary toggle switch upward, and note that the Fish 1 meter reads .7 to 1 which indicates Batts are ok. - Set the Sample Pulse Delay knob to 0 for fresh wa...

[Page 8] JW Fishers PULSE 12

• Batt Check Switch When depressed upward, displays condi- tion of batts on meter number 3. If batts are ok, meter will indicate .7 to 1. • Fish Connectors One, two, or three Fish cables can plug into the Control Box. Power should be off when pl...