SECUTRON MR-2300 Series User Manual

Download or browse on-line these Operation & User’s Manual for Secutron MR-2300 series Control Panel, Fire Alarms.

Secutron MR-2300 series Manual Information:

This manual for Secutron MR-2300 series, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 16 pages, and the size of the file at download is . The document type is Operation & User’s Manual.

Download Manual

More Manuals:

In case you failed to obtain relevant information in this document, please, look through related operating manuals and user instructions for Secutron MR-2300 series. Just click one of the links below to go to the selected manual:

Summary of Contents:

[Page 1] Secutron MR-2300 series

USER GUIDE Revision A Document #: LT-953SEC WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be rea...

[Page 2] Secutron MR-2300 series

Copyrights and Trademarks This manual is copyright 1994 - 2006 by Secutron Inc. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form b...

[Page 3] Secutron MR-2300 series

Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS. Follow the instructions in this installation manual. These instructions must be followed to avoid damage to this product and associated equipment. Product operation and reliability depends upo...

[Page 4] Secutron MR-2300 series

MR-2300 Series LED Version User Guide i Contents Contents.................................................................................................................................... i Introduction ...............................................

[Page 5] Secutron MR-2300 series

MR-2300 Series LED Version User Guide 1 Introduction About this Manual This user’s guide provides information on the main indicators and controls of the MR-2300 Fire Alarm Control Panel. Specifically, with this manual you will learn about what the...

[Page 6] Secutron MR-2300 series

Main Display 2 Main Display Refer to the diagram below for the LED indicators and control buttons locations. The main display panel on the main fire alarm control board consists of: • 18 common LED indicators (top half of display) • Eight common ...

[Page 7] Secutron MR-2300 series

MR-2300 Series LED Version User Guide 3 The Buzzer and LED Indicators Common LED Indicators Buzzer The buzzer sounds if there is a fire alarm, a supervisory alarm, or a trouble in the fire alarm system. It turns off if the condition causing the buzz...

[Page 8] Secutron MR-2300 series

The Buzzer and LED Indicators 4 General Alarm LED Walk Test LED CPU Fail LED Auxiliary Disconnect LED Signal Silence LED Battery Trouble LED Ground Fault LED System Reset LED If the panel is configured as a two-stage system, the red General Alarm LED...

[Page 9] Secutron MR-2300 series

MR-2300 Series LED Version User Guide 5 Alarm Circuit Indicators This operation applies to Initiating Circuits configured as Verified Alarm, Non-Verified Alarm, Water flow Alarm, Sprinkler Alarm, or General Alarm Circuits. The following table summar...

[Page 10] Secutron MR-2300 series

The Buzzer and LED Indicators 6 Trouble-only Circuit Indicators This operation applies to initiating circuits configured as Trouble-Only Circuits. The following table summarizes the indications in response to different events: Signal Circuit Indicat...

[Page 11] Secutron MR-2300 series

MR-2300 Series LED Version User Guide 7 Main Display Buttons System Reset Button Signal Silence Button Fire Drill Button Acknowledge Button General Alarm Button (or Info button for single stage system) Auxiliary Disconnect Button Lamp Test Button Buz...

[Page 12] Secutron MR-2300 series

Circuit (Zone) Disconnect Buttons 8 Circuit (Zone) Disconnect Buttons Circuit (zone) disconnect buttons are provided for all initiating and indicating circuits on the fire alarm control panel. These buttons are located beside their respective indica...

[Page 13] Secutron MR-2300 series

MR-2300 Series LED Version User Guide 9 Glossary Alarm Condition Occurs when devices such as detectors, pull stations, or sprinklers are activated. In a single stage system, this condition will activate all signalling devices throughout the buildi...

[Page 14] Secutron MR-2300 series

Glossary 10 Supervisory Condition Occurs when the system detects open circuits, short circuits, and grounds. A supervisory condition is one that would interfere with the operation of the fire alarm system. Trouble Condition Occurs when an abnorma...

[Page 15] Secutron MR-2300 series

...

[Page 16] Secutron MR-2300 series

© 2005 Secutron, Inc. Canada 25 Interchange Way Vaughan, ON L4K 5W3 Tel: (888) SECUTRON (888) 732-8876 Fax: (905) 660-4113 U.S.A 60 Industrial Parkway, PMB 278 Cheektowaga, New York 14227 Tel: (888) SECUTRON (888) 732-8876 Fax: (905) 660-411...