[Page 1] Triplett 1101-A

TRIPLETT MODEL 1101-A 1 ...

[Page 2] Triplett 1101-A

COMPACT, DIGITAL MULTIMETER WITH BACKLIT DISPLAY & TEMPERATURE TEST 2 1. Introduction 2. Safety Rules and Warnings 3. International Symbols 4. Product Features 5. Specifications 6. Front Panel 7. Measurement Procedures 8. Back...

[Page 3] Triplett 1101-A

WARNING!!! This meter is NOT to be used to measure High Energy circuits (power circuitry fused at greater than 4KW, such as distribution circuits, power entrance circuits, etc.) or circuits classified by CE as CATEG...

[Page 4] Triplett 1101-A

2.13 Insert the test leads in the jacks specified in the instructions for performing particular tests. Inserting the test leads in incorrect jacks can damage the meter and/or injure the user. 2.14 Do not exceed the maximum voltage or current li...

[Page 5] Triplett 1101-A

5 conditions. Allow the meter to warm to room temperature before using. 2.28 Do not modify the meter. Changing the design may make the meter unsafe and may result in injury to the user. 2.29 Use caution when attempting to evaluate if a dange...

[Page 6] Triplett 1101-A

2.40 Do not use the meter if it does not appear to work correctly on all ranges and in all modes. 2.41 Do not use the meter if it has undergone long-term storage under unfavorable conditions. 2.42 Do not use the meter if it may have been dama...

[Page 7] Triplett 1101-A

The following International Symbols are used throughout this manual and on the case of the meter to identify, caution, or warn the user of important product limitations or important operational procedures that must be followed to ensure safe u...

[Page 8] Triplett 1101-A

4: PRODUCT FEATURES 4.1 20 Measurement Ranges 4.2 0.5" (12mm) high LCD display 4.3 3 1/2 digit resolution (2000 counts) 4.4 Backlit LCD display 4.5 Protective shock absorbing "boot" 4.6 Diode Test 4.7 Continuity Bee...

[Page 9] Triplett 1101-A

9 5.1 Display: .............................. 0.5" (12mm) high LCD 5.2 Display Resolution: ........... 2000 counts, 0000 to 1999 5.3 Overrange Indication: ........ First digit displays "1", ...

[Page 10] Triplett 1101-A

Note: a) The following accuracy specifications are valid at 23 degrees C, +/- 5 degrees C, Relative Humidity less than 75% b) The specifications are in the form " +/- (x % of reading + dgt)" where dgt is "Least Significan...

[Page 11] Triplett 1101-A

Resistance Range Resolution Accuracy 200Ω 0.1Ω ± (0.8% rdg + 5 digits) 2000Ω 1Ω 20KΩ 10Ω 200KΩ 100Ω ± (0.8% rdg + 2 digits) 20MΩ 10KΩ ± (1.0% rdg + 5 digits) Open Circuit Voltage: Less than 3V on all ranges ...

[Page 12] Triplett 1101-A

6: FRONT PANEL 1) Backlit LCD Display 2) Backlight and Hold button 3) Rotary Function / Range Selector Switch 4) Transistor Test Jack 5) COM Jack: Common (black) jack for all measurements 6) 10A Jack: Input for currents...

[Page 13] Triplett 1101-A

7.1 DC Voltage Measurement: 7: MEASUREMENT PROCEDURES WARNING! If the magnitude of the voltage to be measured is unknown, always start by setting the meter to the highest range, and then to lower ranges, until a ...

[Page 14] Triplett 1101-A

probes, and rotate the RANGE switch to the next lower position. Reconnect the test probes, reapply power, and read the voltage on the LCD display. If the RANGE switch is already on the lowest position (i.e. 200mV DC), no greater measurement resol...

[Page 15] Triplett 1101-A

7.2.5 If the displayed value is less than "200" (decimal point not shown), a more accurate reading may be obtained by setting the RANGE switch to a lower range. Remove power from the circuit, disconnect the test probes, and rotate th...

[Page 16] Triplett 1101-A

measure 10A, the current being tested exceeds the measurement capability of the meter and cannot be measured. 7.3.5 If the displayed value is less than "200" (decimal point not shown), a more accurate reading may be obtained by setting...

[Page 17] Triplett 1101-A

7.5 Continuity Beeper: WARNING! Do not apply voltage or current to the meter when it is set to the Diode Test / Continuity Beeper mode . 7.5.1 Connect the black test lead to the COM jack and the red test lead to the V/Ω /mA ...

[Page 18] Triplett 1101-A

are connected in either direction to the diode, the diode is probably shorted. Note: The reading displayed on the LCD is not an accurate indication of the voltage drop of the device or circuit being measured. 7.7 Temperature Test: ...

[Page 19] Triplett 1101-A

8: BACKLIGHT AND HOLD 8.1 Backlight: The 1101-A incorporates a light green LED backlight into the LCD assembly. Since the backlight uses more power than anything else in the meter, an anti-tease function on the button prevents ...

[Page 20] Triplett 1101-A

9: MAINTENANCE 9.1 Battery and Fuse Replacement: 9.1.1 On the back of the case, remove the rubber bumpers that cover the case screws. Remove the screws. 9.1.2 Gently open case, starting at the bottom where the screws w...

[Page 21] Triplett 1101-A

21 Note: When replacing the fuse, use the exact type specified. Do not substitute a 250V fuse for the 500V fuse. 9.2 Cleaning: To clean the outside of the meter, use a cloth dampened with a mild detergent solution. Do not use any a...

[Page 22] Triplett 1101-A

10: TRIPLETT THREE YEAR LIMITED WARRANTY The Triplett Corporation warrants instruments and test equipment manufactured by it to be free from defective material or workmanship and agrees to repair or replace such products which, under norm...

[Page 23] Triplett 1101-A

23 Some states (USA ONLY) do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. No representative of Triplett Corporation or any other person is authorized to...

[Page 24] Triplett 1101-A