Adam Equipment ABK Series User Manual

Download or browse on-line these Operation & User’s Manual for Adam Equipment ABK Series Scale, Scales.

Adam Equipment ABK Series Manual Information:

This manual for Adam Equipment ABK Series, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 48 pages, and the size of the file at download is . The document type is Operation & User’s Manual.

Download Manual

More Manuals:

In case you failed to obtain relevant information in this document, please, look through related operating manuals and user instructions for Adam Equipment ABK Series. Just click one of the links below to go to the selected manual:

Summary of Contents:

[Page 1] Adam Equipment ABK Series

© Adam Equipment Company 2011 Adam Equipment ABK, AFK Scales (P.N. 3116611364 - Revision A, December 2011) This Document is Hosted by: www.oldwillknottscales.com ...

[Page 2] Adam Equipment ABK Series

© Adam Equipment Company 2011 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when power is first turned on): Date of Purchase...

[Page 3] Adam Equipment ABK Series

1 | P a g e © Adam Equipment Company 2011 CONTENTS 1.0 INTRODUCTION .................................................................................................................................. 3 2.0 SPECIFICATIONS....

[Page 4] Adam Equipment ABK Series

2 | P a g e © Adam Equipment Company 2011 ...

[Page 5] Adam Equipment ABK Series

3 | P a g e © Adam Equipment Company 2011 1.0 INTRODUCTION • The ABK/AFK scales provides an accurate, fast and versatile general purpose weighing scales with parts counting, percent weighing and chec...

[Page 6] Adam Equipment ABK Series

4 | P a g e © Adam Equipment Company 2011 2.0 SPECIFICATIONS Model # ABK 8 ABK 16a ABK 16 ABK 35a ABK 32 ABK 70a ABK 60 ABK 130a ABK 120 ABK 260a Maximum Capacity 8000g/16lb 16kg/35lb 32kg/70lb 60kg/130lb 1...

[Page 7] Adam Equipment ABK Series

5 | P a g e © Adam Equipment Company 2011 Model # AFK 75/165a AFK 150/330a AFK 300/660a AFK 600/1320a Maximum Capacity 75kg/165lb 150kg/330lb 300kg/660lb 600kg/1320lb Readability 5g/0.01lb 10g/0.02lb 20g/0.05lb ...

[Page 8] Adam Equipment ABK Series

6 | P a g e © Adam Equipment Company 2011 3.0 INSTALLATION 3.1 UNPACKING The ABK/AFK scales have already been adjusted to work with a platform and have been configured for this application. The platform and indicator h...

[Page 9] Adam Equipment ABK Series

8 | P a g e © Adam Equipment Company 2011 3.3 SETTING UP THE SCALES • The pillar is attached to the base using a bracket that must be attached to the base frame first using the 4 bolts supplied. The pi...

[Page 10] Adam Equipment ABK Series

9 | P a g e © Adam Equipment Company 2011 4.0 KEY DESCRIPTIONS [>Z/T<] If near zero, Sets the zero point for all subsequent weighing. The display shows zero. Tares the scale. Stores ...

[Page 11] Adam Equipment ABK Series

10 | P a g e © Adam Equipment Company 2011 [Func/C] Selects the Functions of the scale. If the scale is weighing, it will select parts counting. If it is not in weighing mode, it will return the user to...

[Page 12] Adam Equipment ABK Series

11 | P a g e © Adam Equipment Company 2011 5.0 DISPLAYS The LCD display will show a value and a unit to the right of the digits. In addition the LED’s above the display will show when a weight is below or above check-wei...

[Page 13] Adam Equipment ABK Series

12 | P a g e © Adam Equipment Company 2011 6.0 OPERATION 6.1 ZEROING THE DISPLAY • You can press the [Z/T] key at any time to set the zero point. This will usually be necessary when the platform is empty. When the...

[Page 14] Adam Equipment ABK Series

13 | P a g e © Adam Equipment Company 2011 • Press the [Z/T] key to tare the scale. The weight that was displayed is stored as the tare value and that value is subtracted from the display, leaving zero on the di...

[Page 15] Adam Equipment ABK Series

14 | P a g e © Adam Equipment Company 2011 6.4 PARTS COUNTING If parts counting is enabled, See section 7.4, it is possible to count parts using a sample of the parts to determine average piece weight. • Before ...

[Page 16] Adam Equipment ABK Series

15 | P a g e © Adam Equipment Company 2011 • Press the [Pcs/] key to return to normal weighing. Press the [Pcs/] key again to start counting a different sample. 6.5 CHECK-WEIGHING Check-weighing...

[Page 17] Adam Equipment ABK Series

16 | P a g e © Adam Equipment Company 2011 BOTH LIMITS SET The display will show OK when the weight is between the limits F3 bEP = bP InL . The beeper will sound when the weight is between the limits, i....

[Page 18] Adam Equipment ABK Series

17 | P a g e © Adam Equipment Company 2011 NOTE: Weight must be more than 20 scale divisions for check weighing to operate. Below 20 scale divisions the LED’s will not light and the beeper will not be on. Th...

[Page 19] Adam Equipment ABK Series

18 | P a g e © Adam Equipment Company 2011 6.6 ACCUMULATED TOTAL • The scale can be set to accumulate manually by pressing the [Print/M+/Esc] key or automatically when a weight is removed from the ...

[Page 20] Adam Equipment ABK Series

19 | P a g e © Adam Equipment Company 2011 6.7 PERCENT WEIGHING The scale can be set to perform percent weighing. See Section 7.2. The scale will use a mass on the platform as the 100% reference weight. If the pl...

[Page 21] Adam Equipment ABK Series

20 | P a g e © Adam Equipment Company 2011 comparison to the capacity of the system. A smaller weight will show only “100%” while a larger weight might show “100.00%”. • If the scale was showing zero weight whe...

[Page 22] Adam Equipment ABK Series

21 | P a g e © Adam Equipment Company 2011 6.8 ANIMAL (D YNAMIC ) WEIGHING The scale can be set to animal (dynamic) weighing for weighing any items that are unstable or may move. See Section 7.4. The scale will u...

[Page 23] Adam Equipment ABK Series

22 | P a g e © Adam Equipment Company 2011 6.8.1ANIMAL WEIGHING PROCEDURE • With the platform empty the display will show zero weight. Place containers or blankets onto the platform and press the [Z/T] key to z...

[Page 24] Adam Equipment ABK Series

23 | P a g e © Adam Equipment Company 2011 7.0 USER PARAMETERS Pressing the [Func/C] key during normal operation allows the user to access the parameters for customizing the scale. The parameters are split into ...

[Page 25] Adam Equipment ABK Series

24 | P a g e © Adam Equipment Company 2011 Parameter Description Options Default setting F1 Lo Set Low limit. Use the [Unit/] key and [Pcs/] key to set the values of the lower limit. When set press t...

[Page 26] Adam Equipment ABK Series

25 | P a g e © Adam Equipment Company 2011 [Print/M+/Esc] again, the scale will exit the User Parameter section and return to weighing. Parameter Description Options Default setting P1 PCt This parameter ...

[Page 27] Adam Equipment ABK Series

26 | P a g e © Adam Equipment Company 2011 the Accumulation AC oFF C5 Ln Select Language EnGLi (English) FrEnCH (French) GErmAn (German) SPAn (Spanish) EnGLi C6 UId Set User ID To be entered manually 000...

[Page 28] Adam Equipment ABK Series

27 | P a g e © Adam Equipment Company 2011 This group of parameters is used to control the operation of the scale. Parameter Description Options Default setting S1 Un Enable or disable weighing units, will ...

[Page 29] Adam Equipment ABK Series

28 | P a g e © Adam Equipment Company 2011 8.0 BATTERY OPERATION • The scales can be operated from the battery if desired. The battery life can be up to 70 hours depending on the load cells used...

[Page 30] Adam Equipment ABK Series

29 | P a g e © Adam Equipment Company 2011 3 12 4 9.0 RS-232 INTERFACE The ABK/AFK indicator is supplied with bi-directional RS-232 interface as standard. The scale when connected to a printer or...

[Page 31] Adam Equipment ABK Series

30 | P a g e © Adam Equipment Company 2011 Data Format-Normal Output: Only weight value along with the weighing unit is printed. If Percent weighing is used then % is shown in place of weighing units. Data Format-Parts Co...

[Page 32] Adam Equipment ABK Series

31 | P a g e © Adam Equipment Company 2011 Data Format- Memory Recall Output: Data Format- Continuous Output- Normal weighing: Data Format- Continuous Output- Parts Counting: NOTE: 1. The accumulated total ...

[Page 33] Adam Equipment ABK Series

32 | P a g e © Adam Equipment Company 2011 Description ENGLISH FRENCH GERMAN SPANISH Net weight Net Wt. Pds Net Net-Gew Pso Net Weight per unit counted Unit Wt. Pds unit Gew/Einh Pso/Unid Number of items ...

[Page 34] Adam Equipment ABK Series

33 | P a g e © Adam Equipment Company 2011 10.0 RELAY INTERFACE The indicator is supplied with drivers to control external relays. The drivers could be used to control a number of different relays depending upon the ...

[Page 35] Adam Equipment ABK Series

34 | P a g e © Adam Equipment Company 2011 Connections to the drivers: Connections are made to the PCB, Connector P1. The connector is a spring activated type, simply press on the top of the connector and insert the wir...

[Page 36] Adam Equipment ABK Series

35 | P a g e © Adam Equipment Company 2011 11.0 CALIBRATION The scale can be calibrated using the following procedure. To enter this procedure it is necessary to use Func 4 accessible using the [Func/C] key as descr...

[Page 37] Adam Equipment ABK Series

36 | P a g e © Adam Equipment Company 2011 12.0 SERVICE SECTION The scales will allow entry to the parameters if the [Tare] key is pressed during the power on cycle. The passwords work as above. In ...

[Page 38] Adam Equipment ABK Series

37 | P a g e © Adam Equipment Company 2011 The parameters available are: “F4 Int” Initial Zero Range “F5 rEZ” Re-Zero range “F6 SCS” Successive Tare Enable “F7 Cnt” Display the...

[Page 39] Adam Equipment ABK Series

38 | P a g e © Adam Equipment Company 2011 12.3 PARAMETER DETAILS 12.3.1 F1 -CALIBRATION To enter the calibration parameter, press the [Z/T] key when “F1” is displayed. The scale will be calibrated using 2...

[Page 40] Adam Equipment ABK Series

39 | P a g e © Adam Equipment Company 2011 12.3.3 F3 – CAPACITY/ WEIGHING UNIT/INCREMENT To enter this parameter, press the [Z/T] key when “F3 CAP” is shown. The display will show the current capacity and default wei...

[Page 41] Adam Equipment ABK Series

40 | P a g e © Adam Equipment Company 2011 12.3.4 F4 –INITIAL ZERO RANGE To enter this parameter, press the [Z/T] key when “F4 int” is shown. The display will show the current initial zero range. Press the [Pcs...

[Page 42] Adam Equipment ABK Series

41 | P a g e © Adam Equipment Company 2011 12.3.9 F9 –LOW VOLTAGE DETECTION This parameter allows detection of low voltage when the battery wears down. To enter this parameter, press the [Z/T] key when “F9 LVd” is sho...

[Page 43] Adam Equipment ABK Series

42 | P a g e © Adam Equipment Company 2011 13.0 ERROR CODES ERROR CODES DESCRIPTION SUGGESTIONS - -oL - - Over-range Remove weight from the scale. If the problem persists contact your dealer or Adam Equipm...

[Page 44] Adam Equipment ABK Series

43 | P a g e © Adam Equipment Company 2011 14.0 REPLACEMENT PARTS AND ACCESSORIES If you need to order any spare parts and accessories, contact your supplier or Adam Equipment. A partial list of such it...

[Page 45] Adam Equipment ABK Series

44 | P a g e © Adam Equipment Company 2011 16.0 WARRANTY STATEMENT Adam Equipment offers Limited Warranty (Parts and Labour) for the components failed due to defects in materials or workmanship. Warranty starts...

[Page 46] Adam Equipment ABK Series

45 | P a g e © Adam Equipment Company 2011 ...

[Page 47] Adam Equipment ABK Series

© Adam Equipment Company 2011 Manufacturer’s Declaration of Conformity This product has been manufactured in accordance with the harmonized European standards, fo llowing the provisions of the belo...

[Page 48] Adam Equipment ABK Series

© Adam Equipment Company 2011 ADAM EQUIPMENT is an ISO 9001:2008 certified global company with more than 35 years experience in the production and sale of electronic weighing equipment. For a complete lis...