Growatt Shine Pano User Manual

Download or browse on-line these Operation & User’s Manual for Growatt Shine Pano GPS.

Growatt Shine Pano Manual Information:

This manual for Growatt Shine Pano, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 51 pages, and the size of the file at download is . The document type is Operation & User’s Manual.

Download Manual

Summary of Contents:

[Page 1] Growatt Shine Pano

Shine Pano ...

[Page 2] Growatt Shine Pano

User Manual Information 1.1 Copyright Statement 1.2 About Manual 1.3 Target Group 1.4 Guideline Description Product Installation and Connection System Setting 3.1 Installation Environmental Conditions 3.2 Installation Methods of Shine Pano ...

[Page 3] Growatt Shine Pano

Network Access 6.1 Access via Integrated Web Server 6.2 Access via the Shine Server 6.3 Access via the Shine Station Power Management Maintenance 7.1 Active Power Reduction 7.2 Reactive Power Control 7.3 Manage Active and Reactive Power Simult...

[Page 4] Growatt Shine Pano

1 User Manual Information 1.1 Copyright Statement Copyright © 2012 Shenzhen Growatt New Energy Co,.Ltd, hereinafter referred to as ‘Growatt’. All right reserved. No part of this document may be reproduced, stored in a retrieval system, or ...

[Page 5] Growatt Shine Pano

Before using the Shine Pano, please read the manual carefully. In the meantime, please keep it well, lest maintenance staff may couldn’t find it later. All the content, pictures, logos, symbols are reserved. No part of this document m...

[Page 6] Growatt Shine Pano

2 Description 3 The appearance of Shine Pano is shown below. Friendly user interface are provided with ture color touch screen containing 800x600 pixels. 1. SWITCH 4.COM 2. POWER 1 12 10 6 4 2 11 9 7 5 3 3. LAN 8 8. Fault- LED 9. Normal- LED...

[Page 7] Growatt Shine Pano

7.ANTENNA 5.USB 10. Touch Pen 6.SD-CARD 2.1.1 Indicator Led Indicator led can be divided into fault led and normal led. Fault led indicates fault state, normal led indicates normal state. There are five different led color combinations which stand fo...

[Page 8] Growatt Shine Pano

2.2.2 Interface The description of Shine Pano Interface is listed below. Label Function 1 2 3 4 5 6 7 10 Switch Power Lan COM USB Sd-Card Antenna Touch Pen Name Power Switch:Turn On/Off Shine Pano Power Line:Connect the power line to charge RJ45 port...

[Page 9] Growatt Shine Pano

Label Amount 1 2 3 4 5 6 7 8 Shine Pano 5V Power Adapter 2G SD Card Terminal Rs485 Plastic Column M3.5*20 Screw Spike Shine Pano Instruction Disc Bracket Name 1pc 1pc 1pc 1pc 2pcs 2pcs 1pc 1pc The label is sticked on the back side of the Pano, indica...

[Page 10] Growatt Shine Pano

2.3 Introduction of Product Function Shine Pano is a monitoring device designed and manufactured by Growatt. Shine Pano could monitor inverters via RS485 and ZigBee wireless module. Besides inverters, it can also monitor o...

[Page 11] Growatt Shine Pano

As a terminal display device to show customers about the operation status, Shine Pano can storage history data in internal memory and SD card. If the total amount of inverters monitored by Pano is more than 1 piece, the connec...

[Page 12] Growatt Shine Pano

The monitoring data of Shine Pano contain two aspects: 1.Operation Data of PV plant · The total volume of inverters · The total volume of standing-by inverters · The total volume of error inverters · The total volume of normal inverters · Capaci...

[Page 13] Growatt Shine Pano

3 Product Installation and Connection 3.1 Installation Environmental Conditions The installation environmental conditions of Shine Pano and requirements communicating with other devices: (1) Indoor, temperature 0~45℃ ,humility0~95%,avo...

[Page 14] Growatt Shine Pano

(3) Well-installed Shine Pano is shown as following figure. (4) Connect the portal RS485 of Pano with portal RS485 of inverter (details refer to chapter 3.3.1 hereinafter) or put ZigBee module into portal RS232 of our inverter (5) Cable connection ...

[Page 15] Growatt Shine Pano

(6) Insert SD card ( Start up the Shine Pano after the action of putting SD card inside, otherwise SD card cannot be identified) (7) Connect the Power supply line (8) Switch on Shine Pano Installation steps: (1)Take out the rod from the back of Pano...

[Page 16] Growatt Shine Pano

13 3.3 Connection with PV Devices Shine Pano can communicate with devices like inverters, environment monitors, smart meters etc. 3.3.1 RS485 Wire Connection 1. To set up RS485 wire communication, please notice the identification number...

[Page 17] Growatt Shine Pano

14 ZigBee connection is a communication method between inverters and Pano by which we insert the ZigBee Module into inverters. Before setting up the connection, we need to set the ZigBee ID and Channel. Details please refer t...

[Page 18] Growatt Shine Pano

4 System Setting 4.1 Shine Pano Setting as a Terminal Display The system setting interface is below: 15 1. When communicating with RS 485, please set the “Address Range” in “System Set”, all the inverter address monitored s...

[Page 19] Growatt Shine Pano

16 If the dialog box below appears, the address setting is successfully finished. 2. When communicating with wireless ZigBee, you have to do the inverter address setting as before. After address setting, you should set the wireless ID an...

[Page 20] Growatt Shine Pano

17 2. When communicating with wireless ZigBee, please set the Address Range as before, at the same time, you should set the wireless module ID and channel. After all the setting, reset the wireless module. Then you can set the IP Address...

[Page 21] Growatt Shine Pano

5 Guideline on LCD Display 5.1 LCD Touch Screen The touch screen of Shine Pano is Resistive Touch Screen (RTS), as one of the latest technologies for HMI; it’s an apparent input system and absolute positioning system. The touch screen make...

[Page 22] Growatt Shine Pano

5.3 Record Interface 1. Click or touch the “Record” on main interface using finger or the stylus to get access into the “Record” interface. 19 2. Click or touch the word “E_Histogram” shown in above figure then it will pro...

[Page 23] Growatt Shine Pano

20 3. Click or touch the box that shows the word “Daily in Month” and a drop-down menu will prompt out. Display following information: · Daily in Month · Monthly in Year · Yearly Life time As shown in following figure, click or...

[Page 24] Growatt Shine Pano

21 Note: ·Detailed power data can only be daily viewed. ·Power and energy curve can be daily, monthly and yearly viewed. ·Error information of inverter can only be monthly viewed. 5.4 Setting Interface 5.4.1 System Set Interface System setting int...

[Page 25] Growatt Shine Pano

22 Normal Set Remark Language Update Time Protocol Delay time (s) Address Range System Time Internet_Set English by default 5 minutes by default Modbus by default 2 second by default Address range of inverter Time of inverter location Internet settin...

[Page 26] Growatt Shine Pano

5.4.2 Inverter Set Interface Inverter setting interface is shown as following figure. In the box after Inverter is inverter serial number that to be set. Information of inverter setting is shown in following chart. No. Description 1 2 ...

[Page 27] Growatt Shine Pano

To set active or reactive power control function, firstly corresponding enable option must be open. Introduction to PF Model setting: · PF_by_Set: Enable power factor settings. · Inda_Reactive: Enable inductive reactive power control function. ·...

[Page 28] Growatt Shine Pano

2. Environmental monitor Addren: Set the communication address of ambient sensors, range 1~255 Click “36” using finger or the stylus to select the communication address of ambient sensor, 36 is default value. Select “ON” or “OFF” to open...

[Page 29] Growatt Shine Pano

This interface will display following devices · Serial number of Shine Pano. · Model of Shine Pano. · Software version of Shine Pano. · Hardware version of Shine Pano 5.6 Operation Introduction to Inverter List Click any inverter shown in inverte...

[Page 30] Growatt Shine Pano

6 Network Access 6.1 Access via Integrated Web Server 1. Connect Shine Pano to local network via network cable. 2. Start the web browser, enter 192.169.1.230 in the address bar and press the ENTER key. 27 3. Click on “Record”, this ...

[Page 31] Growatt Shine Pano

28 4. Click on “Back home”, return to the main interface. To go to the configuration page, click on the “Parameter”. 5. Setting parameter A. Set the address of the Shine Pano The address setting includes IP address, subnet mask...

[Page 32] Growatt Shine Pano

29 1) You are able to operate the Shine Pano by using integrated web browser in the local network. Click on “parameter” to go to the setting page. 2) Select “local_ip”, enter the fixed IP number if you want to change the IP ad...

[Page 33] Growatt Shine Pano

2) Click on “save”, the configuration has been carried out successfully; Shine Pano could upload the data to specified server. C. according to the specified server IP, when this fails, it will try to connect the Server by the domain nam...

[Page 34] Growatt Shine Pano

F. Set system time, select “enable_write”, enter the data and time. H. selecting “ON” or “OFF”. Set environmental monitor, the address is 36. Open or shut down this function by G. ZigBee_channel is 11~25. Set ZigBee parameter, the ...

[Page 35] Growatt Shine Pano

6.2 Access via the Shine Server 1. Start web browser and enter http://server.growatt.com . If you are the first time to login, please register in advance. 2. After registration, and fill in the login information. 32 ...

[Page 36] Growatt Shine Pano

3. The main interface is shown below. 4. Regarding to the operation about the Shine Server, please refer to the corresponding user manual. 6.3 Access via the Shine Station The monitoring data in the Shine Pano could be viewed via the Shi...

[Page 37] Growatt Shine Pano

Right click the small icon, select the “Start server”, then the prompt information will pop up. Start web browser (Google Chrome is recommended), enter the native IP address and port number 5678, e.g. the native IP address of the server or comp...

[Page 38] Growatt Shine Pano

Click on “Start Server”, enable the monitoring service. When the Shine Pano is connected to the Shine station successfully, the setting status will display as below. 35 ...

[Page 39] Growatt Shine Pano

6.3.4 Checking Up the Data When Shine Pano connects to the Shine Station well, the plant status could be viewed by the Shine Station. 36 ...

[Page 40] Growatt Shine Pano

7 Power Management Shine Pano power management is composed of active power reduction and reactive power control components. To enable power management, a ripple control receive is required. When this function is required, user should activate...

[Page 41] Growatt Shine Pano

1 5 3 7 9 100% 60% 30% 0% The output power level of inverter depends on the operating relay. The detailed information is shown as below. Pin 1 is connected to 3.3V dc source. Pin Explanation 1 3 5 7 9 3.3V DC source 100% output power 60%...

[Page 42] Growatt Shine Pano

7 9 11 3 5 0. 95 0. 97 0.98 0.99 39 The output reactive power level of inverter depends on the operating relay. The detailed information is shown as below. Pin 11 is connected to 3.3V dc source. Pin Explanation 9 7 5 3 0.99 PF 0.98 PF 0....

[Page 43] Growatt Shine Pano

7.3 Manage Active and Reactive Power Simultaneously If active power and reactive power need to be managed at the same time, connect the Shine Pano with two ripple control receivers as below. 1 5 7 9 11 3 40 7.4 PV Power Station Solution ...

[Page 44] Growatt Shine Pano

41 ...

[Page 45] Growatt Shine Pano

8 Maintenance 8.1 Shine Pano firmware upgrade 42 1. Get upgrade package from Growatt 2. Copy the RAR archive file to the root directory of USB flash disk. ...

[Page 46] Growatt Shine Pano

43 3. Select the RAR archive, right click and select Extract here. Note: You need to have some compressing application like winzip, winRAR, zip7 or any. ...

[Page 47] Growatt Shine Pano

4. Plug the USB flash disk to the Pano when the Shine Pano is turned on. Then the upgrade is carried out automatically. 5. If the Pano beeps twice, the upgrade is OK. If the Pano beeps 3 times rapidly, the upgrade is unsuccessful. Plug ...

[Page 48] Growatt Shine Pano

8.3 Troubleshooting Problem Shine Pano cannot communicate with inverters via Rs485 Shine Pano cannot communicate with inverters via ZigBee Shine Pano cannot connect to the Shine Server 1)Check the connection between inverter and Shine Pano is ...

[Page 49] Growatt Shine Pano

9 Technical Data 9.1 Shine Pano Mechanical data Width*height*depth Net weight 240mm* 160mm * 25mm 820g Environmental conditions Ambient temperature Degree of protection 0 ℃… 45℃ IP 20 Mounting location Indoor Communication Data displaying Rs48...

[Page 50] Growatt Shine Pano

47 Interface Language Display screen LED indicator English 800*600TFT, true color touch screen System operation state indicator Power supply Input Output 100~240V 50/60Hz 5Vdc/2A ...

[Page 51] Growatt Shine Pano

10 Contact Us If you have technical problems concerning our products, please contact the Growatt serviceline. GROWATT NEW ENERGY No.28 Guanghui Road, Longteng Community, Shiyan, Baoan District, Shenzhen, P.R.China. Growatt Serviceline Tel: ...