[Page 1] New Buck Corporation 60

Gas-Fired Vented Room Heaters Models 60, 60ZC, 40 & 25 Installation Manual New Buck Corporation Model60ZC Model 25 Model 60 Model 40 FOR YOUR SAFETY Do not store or use gasoline or other flam· mabie vapors and liquids in the vicinity of this or ...

[Page 2] New Buck Corporation 60

...

[Page 3] New Buck Corporation 60

INDEX INSTALLATION CAUTIONS 2 FREE STANDING INSTALLATIONS................................. 3 POSITIONING THE UNIT........................................ 3 MINIMUM CLEARANCES................ . . . . . . . . . . . . . . . . . . • . . . . . .. 3 CHIM...

[Page 4] New Buck Corporation 60

GAS HEATER MODELS 40, 60 & 25 INSTALLATION INSTRUCTIONS IMPORTANT: Read this manual before installing and using this gas heater. Installation and/or repair of this unit should only be done by a qualified installer. This appliance has been tested ...

[Page 5] New Buck Corporation 60

FREE STANDING INSTALLATION A) POSITION THE UNIT 1. Determine the exact position of your gas heater. If possible place the heater in such a manner that the piping will be placed between two wall studs so additional framing is not necessary. Also, try ...

[Page 6] New Buck Corporation 60

B) INSTALL THE CHIMNEY SYSTEM: WARNING: This gas appliance must not be connected to a chimney flue serving another type of appliance. This heater must be properly connected to a venting system. Class "B" - 4" flue vent vent pipe manufa...

[Page 7] New Buck Corporation 60

C) REMOVE THE GLASS FRONT 1. The glass front is attached with four screws set into key slots, cut into the face. 2. Push up on the entire framework approximately 1/4" and remove by pulling outward. 3. Set glass enclosure aside where it will not ...

[Page 8] New Buck Corporation 60

E) CONNECT THE GAS LINE CAUTION: Installation of the gas line must only be done by a qualified person in accordance with local building codes. 1. Connect gas line. An accessible shut off valve must be installed up stream from the unit. NOTE: DO NOT r...

[Page 9] New Buck Corporation 60

G) COMPLETE THE INSTALLATION 1. Position the logs, either Model 40, 60 or 25 as illustrated below. c Model 60 Figure 5 2. Replace the glass enclosure. H) LIGHTING AND SHUTDOWN NOTE: Prior to lighting, check all fittings for leakage. This is accomplis...

[Page 10] New Buck Corporation 60

NOTE: See example A if your unit automatically lights the pilot. See example B if unit is equipped with a manual igniter; Read 1 - 7 before lighting the unit for the first time. 1. Open the cover door. 2. Turn the regulator valve to pilot, push it in...

[Page 11] New Buck Corporation 60

Example A FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device w...

[Page 12] New Buck Corporation 60

Example B FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by ...

[Page 13] New Buck Corporation 60

ALCOVE INSTALLATION BACKWALL Figure 6 IMPORTANT: TOP VIEW I / o \ ,\ 48" L W 84" - / \ 1. Caution: Read entire manual before installing unit. 2. For clearances see figure 6. 3. This unit may be installed with either igniter. See Example A o...

[Page 14] New Buck Corporation 60

PRE-FAB FIREPLACE INSERT INSTALLATION MANTEL AND/eR SUPPOR1S CCMBUSTlBLE PROJECl1NG MORE THAN 3/4" 12" MIN i 1 I - 1 ..... j/ / - - - " - INSERT lDP - i-- I H - I-- I I § - II ,.-- , - 6 H Mll\L SIDES & TOP TO COMBUSTlBLE MA !ERIA...

[Page 15] New Buck Corporation 60

FOR YOUR SAFETY What To Do If You Smell Gas * * * * * * Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor's phone Follow the gas supplier...

[Page 16] New Buck Corporation 60

Example B FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by ...

[Page 17] New Buck Corporation 60

MASONRY INSERT INSTALLATION MANTEL AND /oCt? SUPPORlS CC».1BUSllBLE PROJECllNG MORE THAN 3/4" INSERT TOP C MIN. SIDES & TOP TO COMBUS1lBLE MA !ERIAL Figure 8 IMPORTANT: 1. Caution: Read entire manual before installing unit. 2. for clearance...

[Page 18] New Buck Corporation 60

FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS * * * * * * Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor's phone Follow the gas supplier...

[Page 19] New Buck Corporation 60

Example A FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device w...

[Page 20] New Buck Corporation 60

I) MAINTENANCE REQUIREMENTS 1. This appliance should be inspected at least once a year by a professional service person. NOTE: INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT L...

[Page 21] New Buck Corporation 60

TROUBLE SHOOTING GUIDE NOTICE: The regulator board includes the following items: Regulator, Generator, pilot, Piezo, Electrode, Rocker Switch, Burner, Orfice and orfice holder. If any of these items are defective, replacement of the entire board woul...

[Page 22] New Buck Corporation 60

GENERATOR 'vi ARNINGI DO NOT CONNECT HIGH VOLTAGE TO THIS SYSTEM Figurp TO PROBLEM No spark when Piezo button is depressed Burner won't light Fire goes out after running for several minutes CAUSE The nut which hold the Piezo in place is loo...

[Page 23] New Buck Corporation 60

REPLACEMENT PARTS PART PART NUMBER Fan Motor PE CFRAME Rheostat PE BC204 Power Cord PE 410712 Thermostat PE 400130 Hearth Brass PO 400705 Door Glass Model 25 PG 25 Model 40 PG 40 Model 60 PG 60 Spill Switch Model 25 PE 400200 Model 40 PE 400300 Model...

[Page 24] New Buck Corporation 60

Zero Clearance Cabinet Model60ZC for use with gas-fired vented room heater Model 60 only FEATURES PREPARATION INST ALL A TION OPERATION MAINTENANCE SAFETY NOTICE SAFETY For your safety, follovv the installation directions. Contact local building or f...

[Page 25] New Buck Corporation 60

RESIDENTIAL INSTALLATIONS The Zero-Clearance Cabinet and the Model 60 (hereafter referred to as the ZC60) is designed for installation in a family dwelling where minimum clearance is desired. INSTALLATION PRECAUTIONS The following precautions are man...

[Page 26] New Buck Corporation 60

NOTE: Chase installation: (See Figure 3). A chase is an enclosure built specifically to house a chimney. The interior of a chase is open from the ZC60 to the roof, eliminating the need to cut through ceilings and the roof. Normally, a chase is built ...

[Page 27] New Buck Corporation 60

3. Now, you are ready to install the chimney system for the ZC60. If you are building an outside chase, follow pipe manufacturer instructions. 4. Obtain the 4" B vent listed pipe and install on ZC60 starter section. See Figure 5. A. Obtain the t...

[Page 28] New Buck Corporation 60

ELECTRICAL INSTALLATION: The next step is the electrical installation. NOTE: an electrician must wire the ZC60 into the home wiring system using No. 15 AWG (with ground wiring) as minimum in accordance with local wiring codes. Remove the two screws h...

[Page 29] New Buck Corporation 60

NEW BUCK CORPORATION (NBC) "LIMITED FIVE YEAR WARRANTY" FOR THE BUCK STOVE AND RELATED PRODUCTS PLEASE READ THIS WARRANTY CAREFULLY This warranty covers your new heating unit, so long as it is owned by the original purchaser, including opti...

[Page 30] New Buck Corporation 60

CONDITIONS AND EXCLUSIONS (A) Replacement of parts may be in the form of new or fully reconditioned parts, at NBC's option. (B) There are no other warranties express or implied including warranties or Merchantability, Fitness for Purpose, or Oth...