[Page 1] Marus CL1000

OWNER’S MANUAL CL1000 Ceiling Light Marus 11727 Fruehauf Drive Charlotte, NC 28273 USA ...

[Page 2] Marus CL1000

Marus 11727 Fruehauf Drive Charlotte, NC 28273 Printed in the U.S.A. 70-050R228 Rev 11 02/12 Technical Support Tech Support: 800-304-5332 FAX: 888-861-9366 Web site: www.marus.com Warranty The Marus Light was thoroughly inspected and...

[Page 3] Marus CL1000

1 Table of Contents General Information ............................................................................................................................... 2 Definition of Symbols ..........................................................

[Page 4] Marus CL1000

2 The following symbols may be used throughout this manual: CAUTION. Failure to carefully follow the described procedure may result in damage to the equipment. WARNING. Failure to carefully follow the described procedure may result in damage to ...

[Page 5] Marus CL1000

3 Storage Conditions: -55°C to +50°C 10% to 90% Relative Humidity The pre-installation must be performed according to the requirements in our ‘Pre-installation Instructions’. As manufacturers of electro-medical products we can assume responsibi...

[Page 6] Marus CL1000

4 Technical Information Technical Specications for the Dental Light Technical Description — Light The dental light is used for illuminating the oral cav- ity during the performance of dental procedures. The position and direction of the light c...

[Page 7] Marus CL1000

5 WARNINGS, DISINFECTING & STERILIZATION - LIGHTS Infection control in the dental ofce continues to be a high priority for our customers and end users. OSHA, the ADA and the CDC are also involved in this complex issue. The Manufacturer will...

[Page 8] Marus CL1000

6 CLEANING YOUR LIGHT Cleaning Reector and Cover NOTE: Use only denatured alcohol to clean the glass reector. Use only mild soap and water to clean the plastic reector cover. Be sure the electrical supply is turned off and the light is coo...

[Page 9] Marus CL1000

7 12” 23 1/2” 21-1/2” - 26” 28” TRAVEL Dimensions Location A typical location for mounting the ceiling mount light is relation to the dental chair for a right-handed operator is shown in Figure 2. Mounting for a left-handed operator would ...

[Page 10] Marus CL1000

8 12” 12” 18” 18” MOUNTING LOCATION FOR RIGHT-HANDED OPERATOR MOUNTING LOCATION FOR LEFT-HANDED OPERATOR TYPICAL POSITION OF CEILING MOUNT IN RELATION TO DENTAL CHAIR Suggested Mounting Methods Figure 2 ...

[Page 11] Marus CL1000

9 1 INCH CEILING JOISTS 16” O.C. POWER SUPPLY CONDUIT FINISHED CEILING MATERIAL MOUNTING PLATE w/ COLLAR POWER CONDUIT COMES THROUGH HOLE 2-1/2” OFFSET FROM CENTER. NEW CONSTRUCTION 1 INCH CEILING JOISTS 16” O.C. (6) 1/4” LAG SCREWS 3” LO...

[Page 12] Marus CL1000

10 CEILING JOIST FIXED CEILING SUSPENDED CEILING SUSPENDED CEILING COVER COVER MOUNTING PLATE w/ COLLAR & POST MOUNTING PLATE w/ COLLAR & POST SUGGESTED INSTALLATION ON SUSPENDED CEILING WOOD STRUCTURE FOR SUSPENDED CEILING FIGURE 5 - ATTAC...

[Page 13] Marus CL1000

11 Metal Structure for Suspended Ceiling Electrical Requirements The 115VAC/230VAC service line for the ceiling light should be evaluated and installed by a licensed electrician in accordance with local electrical codes. We recommend that a wall swi...

[Page 14] Marus CL1000

12 Ceiling Light Installation Instructions Although traditional methods dictate mounting the light to the left side of the chair for a right-handed operator and vice-versa for left-handed, careful consideration should be given to mountin...

[Page 15] Marus CL1000

13 11. Check the light for freedom of movement and for any drift when positioned. Recheck the post and make any necessary leveling adjustments. Raise the ceiling plate cover to the top of the pole and tighten the set screw of the cover stop collar ...

[Page 16] Marus CL1000

14 Power Supply Access Hole Junction Box Post Socket Suspension Tube or Ceiling Post (Refer to chart on Pg. 4) Ground Terminal Safety Bolt Ceiling Mounting Plate Ceiling Plate Cover Stop Collar Coiled Cord Figure 9 Figure 10 Locking Tab Retaining Col...

[Page 17] Marus CL1000

15 Overview / Replacement Parts Controls The on-off switch is located on the control panel directly above the light reector. The long toggle provides easy, one-motion movement to “ick” the light on or off. When the handle is in the up po...

[Page 18] Marus CL1000

16 Turn 1/8 Clockwise to lock - logo should be level Tether Adjustments Bulb Removal and Replacement Note: For maximum reliability and optimum operation, always use Marus replacement bulb #014R207. WARNING! Do not attempt to remove the bulb for...

[Page 19] Marus CL1000

17 Light Focus Adjustments Note: Focus adjustment should be checked each time a new bulb is installed. 1. Place a white paper or cardboard sheet in front of the light* 27 inches from the foremost surface of the bulb shield (or turn the light toward...

[Page 20] Marus CL1000

18 Yoke Pivot Friction Adjustment Horizontal Note: If the light head pivots too freely horizontally, an adjustment can be made as follows: 1. Remove the four screws located at the rear of the light head using a 7/64 hex head wrench. Remove the rear...

[Page 21] Marus CL1000

19 Flex Arm Adjustment Vertical 1. Remove the two ex arm cover screws using a at head screwdriver. (See gure 15). 2. Remove the ex arm cover. 3. Using a 1/2” wrench or socket, adjust the tension bolt until the desired tension is set....

[Page 22] Marus CL1000

20 ELECTROMAGNETIC COMPATIBILITY Electrical medical devices are subject to special EMC safety measurements and as a result the equipment must be installed according to the installation instruction manual. PORTABLE ELECTRONIC DEVICES Portable and mob...

[Page 23] Marus CL1000

21 This product is intended for use in the electromagnetic environment specied below. The customer or the user of this product should ensure that it is used in such an environment. U T is the AC. mains voltage prior to application of the test ...

[Page 24] Marus CL1000

22 NOTE 1: At 80 MHz to 800 MHz, the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reection from structures objects and people. a) Field strengt...

[Page 25] Marus CL1000

23 Guidance and manufacturer‘s declaration-electromagnetic emissions This product is suitable for use in all establishments, other than domestic establishments and those directly connected to the public low voltage power supply network that supp...

[Page 26] Marus CL1000

24 Electrical Schematics CL1000 Ceiling Light - 115V 0V 115V 230V ...

[Page 27] Marus CL1000

25 Electrical Schematics CL1000 Ceiling Light- 230V 230V 115V 0V ...

[Page 28] Marus CL1000

26 Verify the following after installation or servicing of the light: All manuals are present. All labels are present and legible. No mechanical damage on new installations. The arm is balanced and the friction adjustment is adjusted so that ...

[Page 29] Marus CL1000

...

[Page 30] Marus CL1000

...

[Page 31] Marus CL1000

29 Purchase Information Notes / Service History Write in the model and serial numbers below for all applicable equipment such as the chair, unit light and unit control head. MODEL: ____________________________ SERIAL NUMBER: ___________________ DEAL...

[Page 32] Marus CL1000

70-050R228 Rev. 11 •02/12 Marus 11727 Fruehauf Drive Charlotte, NC 28273 USA Technical support: 800-304-5332 Web Site: www.marus.com ...