[Page 1] Sartorius Basic lite

98648-008-55 Operating Instructions Sartorius Basic lite Sartorius Gem lite Electronic Precision Balances and Precious Metal Scales ...

[Page 2] Sartorius Basic lite

2 Practical Use Contents The Basic lite Series and Gem lite Series from Sartorius offer precision balances/ scales with capacities ranging from 0.1 mg to 12 kg. These balances/scales meet the highest requirements on the accuracy and reliability of...

[Page 3] Sartorius Basic lite

3 Getting Started Warranty Do not miss out on the benefits of our full warranty. Please contact your local Sartorius office or dealer for further information. Complete the warranty registration card, if available indicating the date of installation,...

[Page 4] Sartorius Basic lite

4 Installation Instructions Your balance/scale is designed to provide reliable weighing results under normal ambient conditions. When choosing a location to set up your bal- ance/scale, observe the following so that you will be able to work with ad...

[Page 5] Sartorius Basic lite

5 Setting up the Balance/Scale Balances/Scales with an Analytical Draft Shield Chamber: § Place the components listed below inside the chamber in the order given: – Shield plate – Shield ring – Pan support – Weighing pan – Gem tray (only ...

[Page 6] Sartorius Basic lite

6 Connecting the Balance/Scale to AC Power/ Safety Precautions Use only original Sartorius AC adapters: – for Europe: 6971948 – for the RSA: 6971949 – for the U.S.: 6971947 – for Australia: 6971950 § Insert the right-angle plug into the ja...

[Page 7] Sartorius Basic lite

7 Selecting the Line Voltage (Mains Voltage) Use the following original AC adapters for selecting the line voltage: – AC adapter TNG8, order no. 6971951 (universal) or – AC adapter TNG8, order no. 6971952 (for the U.K.) ● Use the switch to tog...

[Page 8] Sartorius Basic lite

8 Operating the Balance/Scale Basic Weighing Function Available Features – Taring the balance/scale You can tare the balance/scale within the entire weighing range. Preparation § Turn on the balance/scale: Press e § To change configurations: Se...

[Page 9] Sartorius Basic lite

9 Calibration/Adjustment* Always calibrate/adjust the balance/scale after setting it up in a new location. Available Features Calibration/adjustment can only be performed when – there is no load on the balance/scale, – the balance/scale is tared...

[Page 10] Sartorius Basic lite

10 Application Programs Counting Purpose With the Counting program you can determine the number of parts that each have approximately equal weight. Available Features – Store the current weight value to have it loaded as the preset reference samp...

[Page 11] Sartorius Basic lite

11 Example Determine an unknown piece count; weigh the preset reference sample quantity Settings (changes in the factory settings required for this example): Menu: Application program: Counting (menu code 2. 1. 4) Reference sample quantity: 20 pcs ...

[Page 12] Sartorius Basic lite

12 Weighing in Percent Purpose This application program allows you to obtain weight readouts in percent which are in proportion to a reference weight. Available Features – Store the current weight value to have it loaded as the preset reference pe...

[Page 13] Sartorius Basic lite

13 Example Determine an unknown percentage; store the weight on the balance/scale as a reference percentage Settings (changes in the factory settings required for this example): Menu: Application program: Weighing in percent (menu code 2. 1. 5) M...

[Page 14] Sartorius Basic lite

14 Weigh Averaging Purpose Use this program to determine weights under unstable ambient conditions. In this program, the balance/scale calculates the weight as the average value from a defined number of individual weighing operations. These weighi...

[Page 15] Sartorius Basic lite

15 Example Determine the weight of a sample in extremely unstable ambient conditions by calculating the average of 10 subweighing operations. Settings (changes in the factory settings required for this example): Menu: Application program: Weigh Av...

[Page 16] Sartorius Basic lite

16 Net-Total Formulation/Second Tare Memory With this application program you can weigh in components for formulation of a mixture. Preparation Configure the Net-Total Formulation/Second Tare Memory application in the operating menu: See “Configuri...

[Page 17] Sartorius Basic lite

17 Toggle Between Weight Units With this application program you can toggle the display of a weight value back and forth between two weight units. Configure the “Toggle Weight Units” application in the operating menu: See “Configuring the Balan...

[Page 18] Sartorius Basic lite

18 Configuring the Balance/Scale Setting the Parameters (Menu Codes) You can configure your Basic lite balance or Gem lite scale to meet individual requirements by selecting from the parameters available in the menu. Example: Adapt the balance/scal...

[Page 19] Sartorius Basic lite

19 Balance/Scale Operating Menu (Overview) ο Factory setting √ User setting Menu 1. Balance/ 1.1. Adapt filter 1.1.1 Minimum vibration scale functions 1.1.2 ο Normal vibration 1.1.3 Strong vibration 1.1.4 Extreme vibration 1.3. Stability range 1...

[Page 20] Sartorius Basic lite

20 Error Codes Error codes are shown on the main display for approx. 2 seconds, after which the program automatically returns to the weighing mode. Display Cause Solution No segments appear No AC power is available Check the AC power supply on the d...

[Page 21] Sartorius Basic lite

21 Care and Maintenance Service Regular servicing by a Sartorius technician will extend the service life of your balance/scale and ensure its continued weighing accuracy. Sartorius can offer you service contracts, with your choice of regular mainte...

[Page 22] Sartorius Basic lite

22 Safety Inspection If there is any indication that safe operation of the balance/scale with the AC adapter is no longer warranted: § Turn off the power and disconnect the equipment from AC power immediately > Lock the equipment in a secure pla...

[Page 23] Sartorius Basic lite

23 Overview Specifications Basic lite Series Model BL210S BL120S BL60S Weighing capacity g 210 120 60 Readability mg 0.1 0.1 0.1 Tare range (subtractive) g 210 120 60 Repeatability <±mg 0.1 0.1 0.1 Linearity <±mg 0.2 0.2 0.2 Operating tempera...

[Page 24] Sartorius Basic lite

24 Gem lite Series Model GC503 GC103 GM1205 Weighing capacity 505 ct/101 g 105 ct/21 g 1200 g Readability 0.001 ct/0.2 mg 0.001 ct/0.2 mg 50 mg Tare range (subtractive) 505 ct/101 g 105 ct/21 g 1200 g Repeatability <± 0.001 ct/0.2 mg 0.001 ct/0.2...

[Page 25] Sartorius Basic lite

25 Basic lite Series and Gem lite Series Model BL150S GM2202 BL1500S, GM1202 BL610, GM1502 GM612 Weighing capacity g 150 2200 1500 1200 610 Readability g 0.001 0.01 0.01 0.01 0.01 Tare range (subtractive) g 150 2200 1500 1200 610 Repeatability <...

[Page 26] Sartorius Basic lite

26 Basic lite Series and Gem lite Series Model BL310, GM212 BL150, BL6100, GM312 GM152 GM6101 Weighing capacity g 310 210 150 6100 Readability g 0.01 0.01 0.01 0.1 Tare range (subtractive) g 310 210 150 6100 Repeatability <±g 0.01 0.01 0.01 0.1...

[Page 27] Sartorius Basic lite

27 Basic lite und Gem lite Serie Model BL3100, BL1500, BL600, BL12 BL6 BL3 GM3101 GM1501 GM601 Weighing capacity g 3100 1500 610 12000 6000 3000 Readability g 0.1 0.1 0.1 1 1 1 Tare range (subtractive) g 3100 1500 610 12 6 3 Repeatability <±g 0...

[Page 28] Sartorius Basic lite

28 Accessories (Options) Product Order No. Interface port, installation kit YDO02BL Data printer YDP04 Data printer YDP03-0CE with date/time, statistics evaluation and transaction counter functions and LCD (data interface required) Paper (5 rolls) ...

[Page 29] Sartorius Basic lite

29 C ...

[Page 30] Sartorius Basic lite