Rinnai RL75i Installation And Operation Manual

Download or browse on-line these Installation And Operation Manual for Rinnai RL75E Water Heater, Water System.

Rinnai RL75E Manual Information:

This manual for Rinnai RL75E, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 94 pages, and the size of the file at download is . The document type is Installation And Operation Manual.

Download Manual

More Manuals:

In case you failed to obtain relevant information in this document, please, look through related operating manuals and user instructions for Rinnai RL75E. Just click one of the links below to go to the selected manual:

Summary of Contents:

[Page 1] Rinnai RL75E

Direct Vent Tankless Water Heater Installaon and Operaon Manual — Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS  ...

[Page 2] Rinnai RL75E

2 VC Series Manual Table of Contents This is the safety alert symbol. This symbol alerts you to potenal hazards that can kill or hurt you and others. Indicates an imminently hazardous situaon which, if not avoided, will result in death o...

[Page 3] Rinnai RL75E

VC Series Manual 3 CAUTION  BURN HAZARD. Hot exhaust and vent may cause serious burns. Keep away from water heater unit. Keep small children and animals away from the unit.  Hot water outlet pipes leaving the unit can be hot ...

[Page 4] Rinnai RL75E

4 VC Series Manual A licensed professional must install the appliance, inspect it, and leak test it before use. The warranty will be voided due to any improper installaon. The installer should have skills such as:  Gas sizing.  Con...

[Page 5] Rinnai RL75E

VC Series Manual 5 Prepare for installaon Parts included Tools needed Materials needed  The appliance must be isolated from the gas supply piping system by closing its individual manual shuto valve during any pressure tesng of ...

[Page 6] Rinnai RL75E

6 VC Series Manual Environment Air surrounding the water heater, venng, and vent terminaon(s) is used for combuson and must be free of any compounds that cause corrosion of internal components. These include corrosive compounds that ...

[Page 7] Rinnai RL75E

VC Series Manual 7 INSIDE CORNER DETAIL FIXED CLOSED OPERABLE FIXED CLOSED OPERABLE B B B A J B M C F B B E D L G A H K I [1] A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family...

[Page 8] Rinnai RL75E

8 VC Series Manual 24" V Check to determine whether local codes supersede these clearances.  Avoid terminaon locaons near a dryer vent.  Avoid terminaon locaons near commercial cooking exhaust.  You must install ...

[Page 9] Rinnai RL75E

VC Series Manual 9 2" 12" 60" 36" Local codes supersede these clearances.  Avoid terminaon locaons near a dryer vent.  Avoid terminaon locaons near commercial cooking exhaust.  Avoid terminaon ...

[Page 10] Rinnai RL75E

10 VC Series Manual Unit clearances * 0 inches from vent components and condensate drain line. The clearance for servicing is 24 inches in front of the water heater. For closet installaon, clearance is 6 inches (152 mm) from the front of t...

[Page 11] Rinnai RL75E

VC Series Manual 11 Freeze Protecon Make sure that in case of freezing weather that the water heater and its water lines are protected to prevent freezing. Damage due to freezing is not covered by the warranty. With electrical power and ...

[Page 12] Rinnai RL75E

12 VC Series Manual Mount to Wall wall installaon brackets 1. Idenfy the installaon locaon and conrm that the installaon will meet all required clearances. 2. Securely aach the water heater to the wall using any of the ...

[Page 13] Rinnai RL75E

VC Series Manual 13 Manufacturer Listed and Tested Vent Products for RL75i, RL94i, and RLX94i Telephone Fax Contact Ubbink Rolux Vent System 800-621-9419 678-829-1666 www.rinnai.us Heat-Fab Saf-T Vent SC system 800-772-0739 413-863...

[Page 14] Rinnai RL75E

14 VC Series Manual Flue Installaon (indoor models only) Vercal Terminaon (condensate collector must be used in all installaons) 3 in (75 mm) minimum ...

[Page 15] Rinnai RL75E

VC Series Manual 15 Condensate (indoor models only) Condensate can form in the vent of high eciency direct vent appliances. Without proper drainage, condensate will damage the heat exchanger. To prevent condensate damage, follow these ...

[Page 16] Rinnai RL75E

16 VC Series Manual Installaon of Plumbing A manual water control valve must be placed in the water inlet connecon to the water heater before it is connected to the water line. Unions may be used on both the hot and cold water lines for ...

[Page 17] Rinnai RL75E

VC Series Manual 17 Isolaon Valves and Pressure Relief Valve The isolaon valves provide the ability to isolate the water heater from the structure’s plumbing and allow quick access to ush the heat exchanger. Check with local code...

[Page 18] Rinnai RL75E

18 VC Series Manual Piping Diagram for Basic Installaon G a s S u p p l y 3 / 4 " C o l d W a t e r S u p p l y L i n e 3/4" Hot Water Supply Line Rinnai Water Heater Rinnai Equipment List Rinnai Water Heaters RIK-KIT (Optional) (3/4...

[Page 19] Rinnai RL75E

VC Series Manual 19 Connect Water Heater to Water Supply Water connecons to the tankless water heater should follow all state and local plumbing codes. If this is a standard installaon, refer to the Piping Diagram for Basic Installao...

[Page 20] Rinnai RL75E

20 VC Series Manual Size the gas pipe The gas supply must be capable of handling the enre gas load required at the locaon. Gas line sizing is based on gas type, the pressure drop in the system, the gas pressure supplied, and gas line typ...

[Page 21] Rinnai RL75E

VC Series Manual 21 Connect Electricity Do not rely on the gas or water piping to ground the water heater. A screw is provided in the juncon box for the grounding connecon. The water heater requires 120 VAC, 60 Hz power from a properl...

[Page 22] Rinnai RL75E

22 VC Series Manual Installaon of Temperature Controller Controller Locaon Cable Lengths and Sizes  The controller should be out of reach of small children.  Avoid locaons where the controller may become hot (near an oven or ...

[Page 23] Rinnai RL75E

VC Series Manual 23 Mounng the controller 1. Make three holes in the wall as shown. 2. Run the cable between the controller and the water heater or the controller and another controller. 3. Remove the face plate from the temperature c...

[Page 24] Rinnai RL75E

24 VC Series Manual Final Checklist □ The water heater is not subject to corrosive compounds in the air. □ The water supply does not contain chemicals or exceed total hardness that will damage the heat exchanger. □ Clearances from th...

[Page 25] Rinnai RL75E

VC Series Manual 25 Technical Data Specicaons * Minimum ow may vary slightly depending on the temperature seng and the inlet water temperature. Minimum acvaon ow is 0.4 GPM (1.5 L/min). Our products are connually b...

[Page 26] Rinnai RL75E

26 VC Series Manual B C D E F G Dimensions RL75i, RL94i, RLX94i RL75e, RL94e 0.4~1.8(10~45) Variable 14.04 (356.6) 22.95 (583) 9.27 (235.5) 5.05 (128.1) 2.67 (67.8) A 9.27 (235.5) 22.95 (583) A 0.28 (7.2) 0.59 (15) 14.04 (356.6...

[Page 27] Rinnai RL75E

VC Series Manual 27 0 10 20 30 40 50 60 70 80 90 100 0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 50.00 55.00 60.00 0 1 2 3 4 5 6 7 8 9 10 11 Pressure Drop Curve RL94, RLX94 RL75 Pressure Loss ( head) Water Flow (gpm) Press...

[Page 28] Rinnai RL75E

28 VC Series Manual Ladder Diagram ...

[Page 29] Rinnai RL75E

VC Series Manual 29 Recirculaon Mode The Rinnai water heater has the ability to control a recirculaon pump. Two modes are available, Economy and Comfort, which recirculate the water in the plumbing system to provide hot water more qui...

[Page 30] Rinnai RL75E

30 VC Series Manual Recirculaon Mode Sequence of Operaon DIP switches (SW2 - white switches, #4, #8) should be set correctly for recirculaon and mode. The Rinnai water heater should be turned on. Pump recirculaon begins when the w...

[Page 31] Rinnai RL75E

VC Series Manual 31 Direct Vent Tankless Water Heater Operaon Instrucons Important Facts about your Water Heater Thank you for purchasing a Rinnai Tankless Water Heater. For proper operaon and safety, it is important to follow the in...

[Page 32] Rinnai RL75E

32 VC Series Manual Consumer Operaon Guidelines for the Safe Operaon of your Water Heater FOR YOUR SAFETY READ BEFORE OPERATING A. This appliance does not have a pilot. It is equipped with an ignion device which automacally ligh...

[Page 33] Rinnai RL75E

VC Series Manual 33 How to use the Temperature Controller The MC-91-2 controller is the standard temperature controller that is supplied with the water heater. On indoor models it is integrated into the front panel. The MCC-91-2 controller ...

[Page 34] Rinnai RL75E

34 VC Series Manual How to Set the Temperature While any hot water is being provided, the temperature seng can only be adjusted between 98° F and 110° F. NOTICE Check local codes for the maximum water temperature seng allowed when use...

[Page 35] Rinnai RL75E

VC Series Manual 35 Temperatures Available with a Controller The water heater can deliver water at only one temperature seng at a me. The available temperatures are provided below. A temperature lower than 98° F (37° C) can be obtaine...

[Page 36] Rinnai RL75E

36 VC Series Manual Temperature Opons Without a Temperature Controller The default temperature seng for this appliance installed without a temperature controller is 120° F (49° C). If desired, the temperature seng can be changed to 14...

[Page 37] Rinnai RL75E

VC Series Manual 37 Diagnosc Codes and Remedies Code Denion Remedy 03 Power interrupon during Bath Fill (Water will not ow when power returns). Turn o all hot water taps. Press ON/OFF twice. 10 Air Supply or Exhau...

[Page 38] Rinnai RL75E

38 VC Series Manual Code Denion Remedy 19 Electrical Grounding licensed professional only Check all components for electrical short. 32 Outgoing Water Temperature Sensor Check sensor wiring for damage. Measure resistance of...

[Page 39] Rinnai RL75E

VC Series Manual 39 The appliance must be inspected annually by a licensed professional. Repairs and maintenance should be performed by a licensed professional. The licensed professional must verify proper operaon aer servicing. Clea...

[Page 40] Rinnai RL75E

40 VC Series Manual Pressure Relief Valve: Operate the valve manually once a year. In doing so, it will be necessary to take precauons with regard to the discharge of potenally scalding hot water under pressure. Ensure discharge water h...

[Page 41] Rinnai RL75E

VC Series Manual 41 Water Heater Pressure Relief Valve 3/4" Ball Valve 3/4" Union Check Valve S Pressure Regulator Circulating Pump Solenoid Valve Boiler Drain Valve KEY G a s S u p p l y V1 V3 V2 V4 H1 H2 H3 Circulating Pump C o l d W...

[Page 42] Rinnai RL75E

42 VC Series Manual If the water heater is not going to be used during a period of possible freezing weather, it is recommended that the water inside the water heater be drained. To manually drain the water: 1. Shut o cold water supply and...

[Page 43] Rinnai RL75E

VC Series Manual 43 NOTICE BEFORE INSTALLATION This direct-vent appliance must be installed by a licensed professional. If you are not properly trained, you must not install this unit. IMPORTANT: In the State of Massachuses (248 CMR 4.00 &...

[Page 44] Rinnai RL75E

44 VC Series Manual Replacement Parts Tech Sheet Gas Control Assembly 100 Electrode / Flame Rod Kit 116, 117 Fan Assembly / Motor 125 Heat Exchanger 143 Water Flow Servo & Sensor 401 Bypass-Servo Assembly 403 Water Filter Assy ...

[Page 45] Rinnai RL75E

VC Series Manual 45 What is covered? The Rinnai Standard Limited Warranty covers any defects in materials or workmanship when the product is purchased by an authorized dealer and installed and operated according to Rinnai wrien installaon...

[Page 46] Rinnai RL75E

46 VC Series Manual How do I get service? You must contact a licensed professional for the repair of a product under this Limited Warranty. For the name of a licensed professional please contact your place of purchase, visit the Rinnai website (...

[Page 47] Rinnai RL75E

VC Series Manual 47 EXTEND THE LABOR COVERAGE UNDER YOUR LIMITED WARRANTY* Luxury Series RL75, RL94, RLX94i REGISTRATION REQUIRED* Rinnai is providing the opportunity to extend your Rinnai Standard Limited Warranty on labo...

[Page 48] Rinnai RL75E

— N’entreposez pas ou n’ulisez pas d’essence ou d’autres vapeurs ou liquides inammables à proximité de cet appareil ou de n’importe quel autre. — QUE FAIRE SI VOUS SENTEZ LE GAZ  N’essayez pas d’allumer un apparei...

[Page 49] Rinnai RL75E

Manuel de Série VC 49 Table des maères Ceci est un symbole d’alerte. Il vous prévient de dangers potenels qui pourraient causer blessures ou mort pour vous et les autres. Indique une situaon dangereuse imminente qui, si elle...

[Page 50] Rinnai RL75E

50 Manuel de Série VC ATTENTION  RISQUE DE BRÛLURES. Des sores très chaudes d’échappement et venlaon peuvent causer de sérieuses brûlures. Restez à l’écart du chaue-eau en fonconnement. Maintenez les p...

[Page 51] Rinnai RL75E

Manuel de Série VC 51 Instrucons d’installaon Étapes d’installaon Préparaon pour l’installaon ........................... 52 Déterminaon d’emplacement de l’installaon . 53 Liste de contrôle pour ...

[Page 52] Rinnai RL75E

52 Manuel de Série VC Préparaon pour l’installaon Pièces incluses Ouls nécessaires Matériaux nécessaires  L’appareil devra être isolé du système de conduite d’alimentaon en gaz en fermant sa vanne de coupur...

[Page 53] Rinnai RL75E

Manuel de Série VC 53 Environment L’air entourant le chaue-eau, la venlaon et la/les terminaison(s) de venlaon est ulisé pour la combuson, et ne doit comporter aucun des composés pouvant provoquer une corrosion de c...

[Page 54] Rinnai RL75E

54 Manuel de Série VC INSIDE CORNER DETAIL FIXED CLOSED OPERABLE FIXED CLOSED OPERABLE B B B A J B M C F B B E D L G A H K I [1] Une venlaon ne doit pas se terminer directement au-dessus d’un trooir ou d’une voie de circula...

[Page 55] Rinnai RL75E

Manuel de Série VC 55 24" V Contrôlez si des réglementaons locales sont plus exigeantes que ces valeurs de dégagements.  Évitez de posionner des terminaisons près d'une venlaon d’un déshydrateur  ...

[Page 56] Rinnai RL75E

56 Manuel de Série VC 2" 12" 60" 36" Les normes locales ont la préséance sur ces recommandaons.  Évitez de posionner des terminaisons près d'une venlaon d’un déshydrateur.  Évitez de p...

[Page 57] Rinnai RL75E

Manuel de Série VC 57 Dégagements autour du chaue-eau * 0 pouce depuis les composants de venlaon et la conduite de drainage de condensats. L’espace libre pour les intervenons de service est de 24 pouces (61 cm) vers l’ava...

[Page 58] Rinnai RL75E

58 Manuel de Série VC Protecon contre le gel Assurez-vous que par temps très froid le chaue-eau et ses conduites d'eau sont protégées pour éviter le gel. Les dommages dus au gel ne sont pas couverts par la garane. Avec un ...

[Page 59] Rinnai RL75E

Manuel de Série VC 59 Montage mural Supports d’installaon murale 1. Idenez l’emplacement de l’installaon et conrmez qu’elle respectera tous les dégagements obligatoires. 2. Fixez solidement le chaue-eau au ...

[Page 60] Rinnai RL75E

60 Manuel de Série VC Fabricant Produits de venlaon listés et testés pour RL75i, RL94i et RLX94i Téléphone Télécopie Contact Ubbink Système de venlaon Rolux 800-621-9419 678-829-1666 www.rinnai.us Heat-Fab Sys...

[Page 61] Rinnai RL75E

Manuel de Série VC 61 Terminaison vercale (Un collecteur de condensats doit être ulisé dans toutes les installaons) 3 pouces (75 mm) minimum 3 pouces (75 mm) minimum Terminaison horizontale ulisant le collecteur de c...

[Page 62] Rinnai RL75E

62 Manuel de Série VC Condensats (modèles d’intérieur uniquement) Des condensats peuvent se former dans la venlaon d’appareils à venlaon directe de grande ecacité. Sans un drainage correct les condensats endommageraie...

[Page 63] Rinnai RL75E

Manuel de Série VC 63 Installaon de la plomberie Des vannes d’isolement sont incluses sur ce chaue-eau. Rinnai recommande fortement l’installaon de vannes d’isolement sur les conduites d’eau chaude et d’eau froide, car e...

[Page 64] Rinnai RL75E

64 Manuel de Série VC Vannes d’isolement et soupapes de décharge Les vannes d’isolement procurent la capacité d’isoler le chaue-eau de la plomberie de la structure et de permere un accès rapide pour rincer l’échangeur ther...

[Page 65] Rinnai RL75E

Manuel de Série VC 65 G a s S u p p l y 3 / 4 " C o l d W a t e r S u p p l y L i n e 3/4" Hot Water Supply Line Rinnai Water Heater Rinnai Equipment List Rinnai Water Heaters RIK-KIT (Optional) (3/4" Fittings Include: 2 Union...

[Page 66] Rinnai RL75E

66 Manuel de Série VC Raccordement du chaue-eau sur l’alimentaon en eau Les connexions d’eau sur le chaue-eau sans réservoir doi‐ vent respecter toutes les normes provinciales et locales de plomberie. Si c’est une install...

[Page 67] Rinnai RL75E

Manuel de Série VC 67 Taille de la conduite de gaz L’alimentaon en gaz doit être à même de sasfaire l’en‐ semble de la consommaon de gaz dans le logement. Le calibre de la conduite de gaz est basé sur le type de gaz, la c...

[Page 68] Rinnai RL75E

68 Manuel de Série VC Raccordement de l’électricité Ne vous basez pas sur la tuyauterie de gaz ou d’eau pour la mise à la terre du chaue-eau. Une vis est fournie au boîer de raccordement pour la liaison de terre. Le chaue-e...

[Page 69] Rinnai RL75E

Manuel de Série VC 69 Installaon de contrôleur de température Emplacement des contrôleurs Longueurs et calibres de câble  Le contrôleur doit être hors de portée des pets enfants.  Évitez les endroits où le contr�...

[Page 70] Rinnai RL75E

70 Manuel de Série VC Montage du contrôleur Faites trois trous dans le mur comme c’est montré. Faites passer le câble entre le contrôleur et le chaue- eau, ou entre le contrôleur et un autre contrôleur. Enlevez la plaque de façad...

[Page 71] Rinnai RL75E

Manuel de Série VC 71 Liste de contrôle nal □ Le chaue-eau n’est pas exposé à des composés corrosifs dans l’air. □ L’eau d’alimentaon ne conent pas de produits chimiques et ne présente pas un taux de dureté...

[Page 72] Rinnai RL75E

72 Manuel de Série VC Données techniques Spécicaons * Le ux minimum varie légèrement selon le réglage de température et la température d’arrivée de l’eau. Le ux d’acvaon minimum est de 0,4 GPM (soit 1,5 litres...

[Page 73] Rinnai RL75E

Manuel de Série VC 73 B C D E F G Dimensions RL75i, RL94i, RLX94i RL75e, RL94e 0,4~1,8 (10~45) Variable 14,04 (356,6) 22,95 (583) 9,27 (235,5) 5,05 (128,1) 2.67 (67.8) A 9,27 (235,5) 22,95 (583) A 0,28 (7,2) 0,59 (15) 14,...

[Page 74] Rinnai RL75E

74 Manuel de Série VC 0 10 20 30 40 50 60 70 80 90 100 0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 50.00 55.00 60.00 0 1 2 3 4 5 6 7 8 9 10 11 Courbe de chute de pression RL94, RLX94 RL75 Chute de pression (tête d’eau en ...

[Page 75] Rinnai RL75E

Manuel de Série VC 75 Diagramme en escalier PHASE FUSIBLE 10A POMPE RELAIS 3 INTERRUPTEUR DÉTECTEUR DE GEL RELAIS 2 NEUTRE CHAUFFAGE ANTIGEL VARISTANCE DÉCHARGEUR DE FOUDRE TERRE ALIENTATION À DÉCOUPAGE VARISTANCE RELAI...

[Page 76] Rinnai RL75E

76 Manuel de Série VC Mode recirculaon Le chaue-eau Rinnai a la capacité de contrôler une pompe de recirculaon. Deux modes sont disponibles, Economy et Comfort, qui font recirculer l’eau dans le système de plomberie pour fourni...

[Page 77] Rinnai RL75E

Manuel de Série VC 77 Mode recirculaon (Suite) Séquence de fonconnement Les micro-commutateurs DIP (N° 4 et 8 du bloc blanc SW2) doivent être posionnés correctement pour le mode de recirculaon. Le chaue-eau Rinnai doit �...

[Page 78] Rinnai RL75E

78 Manuel de Série VC Chaue-eau sans réservoir à venlaon directe Instrucons d’ulisaon Points importants concernant votre chaue-eau Merci d’avoir acheté un chaue-eau Rinnai sans réservoir. Pour un bon fonc�...

[Page 79] Rinnai RL75E

Manuel de Série VC 79 Consignes à l’opérateur pour un fonconnement sûr de son chaue-eau POUR VOTRE SÉCURITÉ LISEZ CECI AVANT DE COMMENCER Cet appareil ne comporte pas de veilleuse. Il est équipé d’un disposif d’all...

[Page 80] Rinnai RL75E

80 Manuel de Série VC Mode d’emploi du contrôleur de température Le contrôleur MC-91-2 est le contrôleur de température standard qui et livré avec le chaue-eau. Sur les modèles d’intérieur il est intégré dans son panneau fr...

[Page 81] Rinnai RL75E

Manuel de Série VC 81 Fixaon de la température Pendant que de l’eau chaude est en cours de distribuon, le réglage de température ne peut être ajusté qu’entre 98°F et 110°F (36,7- 43,3 °C). AVIS Vériez les normes l...

[Page 82] Rinnai RL75E

82 Manuel de Série VC Températures disponibles avec un contrôleur Le chaue-eau peut fournir de l’eau à un seul niveau de température à la fois. Les températures possibles sont données ci- dessous. Une température inférieure à 9...

[Page 83] Rinnai RL75E

Manuel de Série VC 83 Opons de température sans contrôleur de température Le réglage de température par défaut de cet appareil installé sans contrôleur de température est de 120°F (49 °C). Si on le souhaite ce réglage de tem...

[Page 84] Rinnai RL75E

84 Manuel de Série VC Diagnosc Codes and Remedies Code Dénion Remède 03 Interrupon du secteur durant un remplissage de baignoire (l’eau ne coulera pas au rétablissement du Fermez tous les robinets d’eau chaude. Ap...

[Page 85] Rinnai RL75E

Manuel de Série VC 85 Code Dénion Remède 19 Mise à la terre électrique Professionnel agréé uniquement Contrôlez tous les composants pour chercher des courts-circuits électriques. 32 Capteur de température de sor...

[Page 86] Rinnai RL75E

86 Manuel de Série VC L’appareil doit être inspecté annuellement par un professionnel agréé. Installaon et intervenons de service doivent être eectuées par un professionnel agréé. Ce professionnel agréé doit vérier l...

[Page 87] Rinnai RL75E

Manuel de Série VC 87 Soupape de décharge Faites fonconner la soupape manuellement une fois par an. Pour cela, il est nécessaire de prendre des précauons contre la sore d’eau sous pression pouvant potenellement vous éboui...

[Page 88] Rinnai RL75E

88 Manuel de Série VC Water Heater Pressure Relief Valve 3/4" Ball Valve 3/4" Union Check Valve S Pressure Regulator Circulating Pump Solenoid Valve Boiler Drain Valve KEY G a s S u p p l y V1 V3 V2 V4 H1 H2 H3 Circulating Pump C o l...

[Page 89] Rinnai RL75E

Manuel de Série VC 89 Si le chaue-eau ne doit pas être ulisé durant une période où il pourrait geler, il est recommandé que l’eau à l’intérieur soit vidangée. Pour vidanger manuellement le chaue-eau : Coupez les alim...

[Page 90] Rinnai RL75E

90 Manuel de Série VC Pièces de rechange N° d’arcle de la che technique Ensemble de commande de gaz 100 Kit d’électrode/ électrode de gaz 116, 117 Ensemble de venlateur/ 125 Échangeur thermique 143 Servo et capt...

[Page 91] Rinnai RL75E

Manuel de Série VC 91 Ce qui est couvert La garane limitée standard de Rinnai couvre tous les défauts dus aux matériaux ou à la main-d’œuvre quand le produit est installé et exploité en conformité avec les instrucons d’ins...

[Page 92] Rinnai RL75E

92 Manuel de Série VC Obtenon d’un service sous garane Vous devez contacter un professionnel agréé pour la réparaon du produit sous cee garane limitée. Pour obtenir le nom d’un professionnel agréé veuillez contacter ...

[Page 93] Rinnai RL75E

Manuel de Série VC 93 EXTENSION DE LA COUVERTURE EN MAIN-D’ŒUVRE AVEC VOTRE GARANTIE LIMITÉE* RL75, RL94, RLX94i de Série Luxury ENREGISTREMENT NÉCESSAIRE* Rinnai ore l’opportunité d’étendre votre garan...

[Page 94] Rinnai RL75E

U307-0730 100000244(05) 7/2014 ...