Download or browse on-line these Installation Manual for Rointe RD SERIES Water Heater.
This manual for Rointe RD SERIES, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 20 pages, and the size of the file at download is . The document type is Installation Manual.
In case you failed to obtain relevant information in this document, please, look through related operating manuals and user instructions for Rointe RD SERIES. Just click one of the links below to go to the selected manual:
Pages: 56
[Page 1] Rointe RD SERIES
RD SERIES Digital Electric Water Heater Wall-hung Unvented INSTALLATION MANUAL ...
[Page 2] Rointe RD SERIES
02 WELCOME Dear Customer, Thank you for choosing the RD Series electric water heater, with an exclusive electronic temperature programmer and made with the highest quality materials. The RD Series water heaters have exceeded the most stringent quali...
[Page 3] Rointe RD SERIES
03 TABLE OF CONTENTS 1. Introduction ......................................................................................................................................... 04 2. Technical Specifications .............................................
[Page 4] Rointe RD SERIES
04 1. INTRODUCTION The “RD Series” is a high quality unvented enamelled steel domestic hot water cylinder suitable for domestic hot water systems where the cold mains water supply has a maximum supply pressure of 0.9 MPa. Reduced performance i...
[Page 5] Rointe RD SERIES
05 3. GENERAL REqUIREMENTS 3.1. The RD SERIES domestic hot water cylinder MUST be installed by a competent person in accordance with section G3 of the current Building Regulations. 3.2. Important - It is important that the installer reads...
[Page 6] Rointe RD SERIES
06 The distance between holes for the wall mounting depends on the model, see the following table for reference: Model RDI050 RDI075 RDI100 RDI150 RDI200 Horizontal width between holes 350 mm 350 mm 350 mm 350 mm 350 mm Height between upper and lowe...
[Page 7] Rointe RD SERIES
07 vessel MUST be fitted to the safety group. The expansion vessel MUST be positioned with the entry point at the bottom – see Figure 2. IMPORTANT: Regular checks must be carried out to ensure that the expansion vessel is correctly pressurised...
[Page 8] Rointe RD SERIES
08 4.9. Discharge arrangement. The tundish must be installed in a position so that it is clearly visible by the user. In addition, the discharge pipe from the Tundish should terminate in a safe place where there is no risk to persons in the vicinit...
[Page 9] Rointe RD SERIES
09 such discharges. SIZING OF COPPER DISCHARGE PIPE “D2” FOR COMMON TEMPERATURE RELIEF VALVE OUTLET SIZES �...
[Page 10] Rointe RD SERIES
10 5. ELECTRICAL INSTALLATION WARNING: THIS EQUIPMENT MUST BE EARTHED. All electrical wiring must be carried out by a competent person and in accordance with the current I.E.E. Wiring Regulations. All pipework should be earthed! 5.1. The sheathe...
[Page 11] Rointe RD SERIES
11 6. FILLING AND COMMISSIONING 6.1. Check that the expansion vessel charge pressure is 0.15 or 0.3 MPa. 6.2. Check that all water and electric connections are correctly configured. 6.3. Open the main stopcock and fill the unit. Open succe...
[Page 12] Rointe RD SERIES
12 7.7. Check the charge pressure in the expansion vessel and top up as necessary. The charge pressure should be 0.15 or 0.3 MPa. 7.8. Close the drain cock, disconnect the hose, refit the heating element and close all hot water taps before re...
[Page 13] Rointe RD SERIES
13 9. USER INSTRUCTIONS 9.1. Your RD Series unvented hot water cylinder has been designed to give many years of trouble free service. 9.2. When a hot tap is turned on there may be a short surge of water, this is quite normal with unvented systems ...
[Page 14] Rointe RD SERIES
14 9.6 Working the RD series Water Heater The RD series water heater is set in the factory to Stand by. Due to this, for the heater to work once installed press the ON button . 9.7 On and Stand-by When you press a beep will sound and the indicato...
[Page 15] Rointe RD SERIES
15 9.9 Programme When the indicator is on indicates that the Rointe RD Series water heater has been programmed using the M Series Remote Control. Please refer to its manual for further reference about how to programme the Rointe Digital System....
[Page 16] Rointe RD SERIES
16 10. GUARANTEE 10.1. Rointe guarantee all electrical and mechanical controls supplied with the cylinder for a period of 2 years from the date of purchase provided that they have been installed for their intended use by a competent pe...
[Page 17] Rointe RD SERIES
17 DIMENSIONS AND TECHNICAL CHARACTERISTICS REFERENCE RDI050 RDI075 RDI100 RDI150 RDI200 CAPACITY (L) 50 75 100 150 200 POWER (W) 230 V~ 2,400 2,400 2,400 3,000 3,000 HEATING ELEMENTS 2 x 1,200 W 2 x 1,200 W 2 x 1,200 W 2 x 1,500 W 2 x 1,500 W THERMA...
[Page 18] Rointe RD SERIES
18 11. INSTALLATION, COMMISSIONING AND SERvICE RECORD CUSTOMER DETAILS NAME ADDRESS TEL No. INSTALLER DETAILS COMPANY NAME DATE ADDRESS TEL No. INSTALLER NAME REGISTRATION No. COMMISSIONING ENGINEER (IF DIFFERENT) COMPANY NAME DATE ADD...
[Page 19] Rointe RD SERIES
19 SERVICE RECORD DETAILS Before completing the appropriate Service Interval Record below, please ensure you have carried out the service as described in the manufacturer’s instructions and in compliance with all relevant codes of practice. It ...
[Page 20] Rointe RD SERIES
ROINTE UK Catalyst House 720 Centennial Court Centennial Park Elstree, Herts, WD6 3SY. CUSTOMER SERVICE T. 0845 604 5987 FAX NUMBER F. 0208 953 5861 e-mail: [email protected] www.rointe.co.uk MIRDI12V1 ...
Instruction manual (24 pages)
Owner's manual (22 pages)
Instruction manual (56 pages)
Instruction manual (16 pages)
User's information manual (16 pages)
Instruction manual (40 pages)