[Page 1] Extron electronics MTP 1500RL 15HD A SEQ

User Guide MTP 1500RL 15HD A SEQ Twisted Pair Extended Distance Twisted Pair Receiver 68-1554-01 Rev. B 01 12 ...

[Page 2] Extron electronics MTP 1500RL 15HD A SEQ

Precautions This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous ...

[Page 3] Extron electronics MTP 1500RL 15HD A SEQ

FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful in...

[Page 4] Extron electronics MTP 1500RL 15HD A SEQ

Conventions Used in this Guide In this user guide, the following are used: CAUTION: A caution indicates a potential hazard to equipment or data. NOTE: A note draws attention to important information. TIP: A tip provides a suggestion to make workin...

[Page 5] Extron electronics MTP 1500RL 15HD A SEQ

PRELIMINARY PRELIMINARY Contents Introduction............................................................ 1 MTP 1500RL 15HD A SEQ Description ................. 1 Features .......................................................... 1 Transmission Dista...

[Page 6] Extron electronics MTP 1500RL 15HD A SEQ

MTP 1500RL 15HD A SEQ • Contents vi ...

[Page 7] Extron electronics MTP 1500RL 15HD A SEQ

Introduction This manual details the installation and operation of the Extron MTP 1500RL 15HD A SEQ Twisted Pair receiver with audio and skew equalization In this guide the following terms are used: z “Transmitter” refers specifically to the M...

[Page 8] Extron electronics MTP 1500RL 15HD A SEQ

Transmission Distance The maximum transmission distance is determined by the frequency and resolution of the transmitted signal. The table below shows the maximum transmission distances (in feet and meters) and the transmitter Pre-peak switch posit...

[Page 9] Extron electronics MTP 1500RL 15HD A SEQ

MTP 1500RL 15HD A SEQ Application Diagram MTP 1500RL 15HD A SEQ POWER 12V 1.0A MAX OUTPUT MONO L R AUDIO H + V + CSYNC SOG VIDEO END SPARE ON INPUT BUFFERED OUTPUT MTP MTP MTP 1500RL 15HD A SEQ POWER 12V 1.0A MAX OUTPUT MONO L R AUD...

[Page 10] Extron electronics MTP 1500RL 15HD A SEQ

Installation and Setup This section describes how to connect applicable cables to the MTP 1500RL A SEQ receiver. It covers: z Rear Panel Features z Power Supply Wiring z TP Cable Termination Rear Panel Features Rear panel connectors and features ...

[Page 11] Extron electronics MTP 1500RL 15HD A SEQ

d High resolution video output connector — Connect a projector or other high resolution video device to this 15-pin HD connector for RGB output. NOTE: See DIP switch settings for signal format output. e Audio connector — Connect a suitable au...

[Page 12] Extron electronics MTP 1500RL 15HD A SEQ

Power Supply Wiring NOTE: This product is intended to be supplied by a UL Listed power supply and output rated at 12 VDC, 1 A. Wire the supplied male power connector (plug) as in shown below. 12V 1.0 A MAX POWER Rear Panel Power Receptacle DC Pow...

[Page 13] Extron electronics MTP 1500RL 15HD A SEQ

TP Cable Termination NOTE: RJ-45 termination must comply with TIA/EIA T568A or TIA/EIA T568B wiring standards for all connections. The gure below details the recommended termination of TP cables with RJ-45 connectors in accordance with the TIA...

[Page 14] Extron electronics MTP 1500RL 15HD A SEQ

Operation This section describes the operation details for the MTP 1500RL RS SEQ receiver. It covers: z Front Panel Controls and Indicators z Peaking and Level Adjustment z Skew Delay Compensation Front Panel Controls and Indicators Front panel fe...

[Page 15] Extron electronics MTP 1500RL 15HD A SEQ

d Adjust skew control — This control delays the selected red, green, or blue video signal up to a maximum of 62 nanoseconds (ns), made in 2 ns incremental steps. Rotate the control counterclockwise to reduce the delay or clockwise to increase it...

[Page 16] Extron electronics MTP 1500RL 15HD A SEQ

Skew Delay Compensation CAT 5, 5e and CAT 6 cable can lead to registration errors between the red, green, and blue video signals. Pair skew can be measured with test equipment or identified by viewing a crosshatch test pattern to determine if eith...

[Page 17] Extron electronics MTP 1500RL 15HD A SEQ

Reference Information This section provides information about: z Specifications z Part Numbers and Accessories Specications Video Gain ............................................... Unity Number/signal type ........................ 1 set ...

[Page 18] Extron electronics MTP 1500RL 15HD A SEQ

Audio output Number/signal type ........................ 2 mono, balanced/unbalanced Connectors .................................... (1) 3.5 mm captive screw connector, 5 pole Impedance ..................................... 50 ohms unbalanced, ...

[Page 19] Extron electronics MTP 1500RL 15HD A SEQ

Part Numbers and Accessories Included Parts Description Part Number MTP 1500RL 15HD A SEQ receiver 60-959-02 External, 12 VDC, 1A power supply PS 1210 C 70-775-01 3.5 mm, 3-pole captive screw connector for RS 232 connections IEC power cord (1) MTP 15...

[Page 20] Extron electronics MTP 1500RL 15HD A SEQ

Mounting This section outlines the various mounting options available for the MTP 1500RL unit: z Tabletop Placement z Rack Mounting z Under-desk Mounting z Through-desk Mounting Tabletop Placement Attach the four provided rubber feet to the botto...

[Page 21] Extron electronics MTP 1500RL 15HD A SEQ

Rack Mounting Procedure The unit can be mounted on optional rack systems, including: z RSU 129: 9.5 inch deep, 1U rack shelf kit (part number 60-190-01) z RSU 126: 6 inch deep, 1U rack shelf kit (part number 60-190-10) To mount the device on a rack...

[Page 22] Extron electronics MTP 1500RL 15HD A SEQ

Warranty Extron Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to fau...