[Page 1] Valor Fires Artura 958

5131883/01 © Baxi Heating U.K. Limited 2008. Model 958 INSET LIVE FUEL EFFECT GAS FIRE Fitted with an Artura fascia (GC No. 32-032-89) We trust that this guide gives sufficient details to enable this appliance to be installed and maintained satisfac...

[Page 2] Valor Fires Artura 958

© Baxi Heating U.K. Limited 2008. All rights reserved. No part of this publication may be reproduced in any material form (including photocopying), stored in any medium by electronic means (including in any retrieval system or database) or transmitt...

[Page 3] Valor Fires Artura 958

Safety First. Valor Fires fires are CE Approved and designed to meet the appropriate British Standards and Safety Marks. Quality and Excellence. All Valor Fires fires are manufactured to the highest standards of quality and excellence and are manufac...

[Page 4] Valor Fires Artura 958

Page 4 © Baxi Heating U.K. Limited 2008. INSTALLER GUIDE FOR OWNER GUIDE SEE PAGES 34 TO 47 INSTALLER GUIDE ...

[Page 5] Valor Fires Artura 958

CONTENTS Section Heading Page INSTALLER GUIDE 4 - 33 OWNER GUIDE 34 - 47 1. SAFETY 6 2. ACCESSORY LIST 6 3. APPLIANCE DATA 7 4. GENERAL INSTALLATION REQUIREMENTS 8 5. PACK CONTENTS 15 6. FIREPLACE CHECK 17 7. IGNITION CHECK 18 8. GAS SUPPLY CO...

[Page 6] Valor Fires Artura 958

1. SAFETY Installer Before continuing any further with the installation of this appliance please read the following guide to manual handling:  The lifting weight (kg) of this appliance is as below: Heat engine Casting Fascia Total 6.80 3.84 3.00...

[Page 7] Valor Fires Artura 958

3. APPLIANCE DATA Under no circumstances is this fire to be converted to LPG. An LPG conversion kit does not exist for this gas fire. The appliance information label is located on a plate at the base of the fire. This can be seen by lifting the botto...

[Page 8] Valor Fires Artura 958

The efficiency of this appliance has been measured as specified in BS 7977 - 1 and the result is as below : Model Efficiency % (Gross) 958 Artura 51 The gross calorific value of the fuel has been used for this efficiency calculation. The test data f...

[Page 9] Valor Fires Artura 958

In Scotland, the current edition of the Building Standards (Scotland) Regulations issued by the Scottish Executive. In Northern Ireland, the current edition of the Building regulations (Northern Ireland) issued by the Department of the Environment f...

[Page 10] Valor Fires Artura 958

front of the fixing plane of the fire will meet the requirement. 4.2.3 To a fireplace incorporating a metal flue box complying with the constructional requirements of the current edition of BS715. The dimensions of the flue box must conform to those ...

[Page 11] Valor Fires Artura 958

4.3 Suitable flues and minimum flue sizes are as follows: - It should be noted that, as with many appliances, sharp bends or horizontal runs in metal flues at the top of the system can be a cause of problems in these types of installation.  225m...

[Page 12] Valor Fires Artura 958

4.10 The front face of the fireplace should be reasonably flat over the area covered by the hotbox top and side flange seals to ensure good sealing. These faces should be made good if necessary. The fireplace floor should be reasonably flat to ensure...

[Page 13] Valor Fires Artura 958

4.17 The minimum height from the base of the fireplace opening to the underside of any shelf made from wood or other combustible materials is shown below:- • For a shelf up to 150mm deep Minimum height = 750mm. • For a shelf deeper than 150mm Min...

[Page 14] Valor Fires Artura 958

Page 14 © Baxi Heating U.K. Limited 2008. Figure 5. Appliance dimensions and clearances (Fascia may differ from that shown) Key Description Dimension (mm) A Appliance height 702 B Appliance width 594 C Appliance depth into room 100 D Minimum man...

[Page 15] Valor Fires Artura 958

5. PACK CONTENTS (See figure 6). Carefully remove all the contents. Take special care in handling the ceramic fuel effects. Check that all the listed parts are present and in good condition. The pack may contain additional components to that stated a...

[Page 16] Valor Fires Artura 958

Page 16 © Baxi Heating U.K. Limited 2008. Figure 6. Pack contents INSTALLER GUIDE ...

[Page 17] Valor Fires Artura 958

6. FIREPLACE CHECK 6.1 Fireplace check. 6.1.1 Fireplace size The fireplace must comply with the requirements described in section 4.2. This will probably entail removing the fireback and infill material behind the fireback. The debris catchment area ...

[Page 18] Valor Fires Artura 958

6.2 Fireplace flue pull. Close all doors and windows in the room in which the appliance is to be installed. After confirming with a match that smoke is drawn into the flue, light a 13 gram smoke pellet and check that there is a definite flow through ...

[Page 19] Valor Fires Artura 958

9. PREPARING APPLIANCE FOR INSTALLATION 1. Remove the two screws to the side of the burner unit. 2. Detach the burner unit from the hotbox by lifting clear. 3. It is important that the grommet supplied in the loose parts pack is fitted to the hole i...

[Page 20] Valor Fires Artura 958

7. Supplied with the fire are a short and long length of self adhesive foam seal. Take the short length, peal off the adhesive backing and stick it to the underside of the hotbox (See figure 11). 8. Supplied with the fire is a spacer frame. This is m...

[Page 21] Valor Fires Artura 958

10. The long length of self adhesive foam seal supplied with the fire will need to be fitted to the outer rear edges of the side and top pieces of the spacer frame. Ensure that there is no gap between the foam seals where they meet at the top flange ...

[Page 22] Valor Fires Artura 958

10. HOTBOX INSTALLATION 10.1 Cable retention and floor fixing. 1. Make sure that the relevant areas at the fireplace back or floor are sound enough to take the eyebolts and screws. If these areas have deteriorated due to prolonged use they should be ...

[Page 23] Valor Fires Artura 958

bottom of the hotbox back panel (See figure 19) (For precast or clay block flue systems return the cables through the slotted holes in the side of the hotbox). 7. Place the hotbox fully back into the fireplace opening so that it is sealed against the...

[Page 24] Valor Fires Artura 958

14. Feed the free length of the cables into the gap between the inner and outer back panels so that they are available to allow easy removal and refitting of the appliance during subsequent service calls. Do not cut off the free lengths of cable. On ...

[Page 25] Valor Fires Artura 958

11.3.1 Lighting the fire. If closed , open the isolating ‘T’ connector valve. Depress the control knob and rotate it anticlockwise to the pilot ignition position. A ‘click’ will be heard as the integral piezo operates. A spark should be seen ...

[Page 26] Valor Fires Artura 958

12. FASCIA INSTALLATION BEFORE FITTING THE FASCIA, COMPLETE THE INFORMATION IN THE WARRANTY AND SERVICE SECTION OF THE OWNER GUIDE (See last pages of the OWNER guide). 12.1 Fitting the fascia. 1. Unpack the fascia. Carefully lift the fascia. Place th...

[Page 27] Valor Fires Artura 958

14. FULL OPERATING CHECKS 14.1 Check the control settings. Please note: When first turned on from cold, the flames will appear predominantly blue. When operating the fire for the first time, some vapours may be given off which could set off smoke ala...

[Page 28] Valor Fires Artura 958

still not drawn into the appliance inspect the sealing to the fireplace surround. If the sealing is satisfactory but the appliance is installed with the flue restrictor (See section 9 point 6) remove the restrictor, reseal the appliance and retest. I...

[Page 29] Valor Fires Artura 958

15. FINAL REVIEW 1. COMPLETE THE INFORMATION IN THE WARRANTY AND SERVICE SECTION OF THE OWNER GUIDE (See last pages of the OWNER guide). 2. Visually inspect the appliance. Clean off any marks incurred during installation. The fire should be ‘off’...

[Page 30] Valor Fires Artura 958

16. SERVICING & PARTS REPLACEMENT This product uses fuel effect pieces containing Refractory Ceramic Fibres (RCF), which are man-made vitreous silicate fibres. Excessive exposure to these materials may cause irritation to eyes, skin and respirato...

[Page 31] Valor Fires Artura 958

16.2 To remove the burner unit. 1. Remove the fascia as in section 16.1. 2. Remove the two screws to the side of the burner unit. 3. Support the inlet ‘T’ connector to avoid straining the pipework and disconnect the appliance from the inlet ‘T...

[Page 32] Valor Fires Artura 958

7. Remove the control knob by pulling forward. 8. Remove the gas valve spindle extension by removing the screw that secures it to the gas valve spindle. 9. Remove the thermocouple by unscrewing the thermocouple nut at the gas valve. 10. Remove the he...

[Page 33] Valor Fires Artura 958

16.8 To remove the main burner injector. (See figure 32). 1. Remove the burner (See section 16.7). 2. Remove the burner clamping screw (See figure 32). 3. Unscrew the injector from the burner. 4. Refit in the reverse order. 16.9 To remove the applian...

[Page 34] Valor Fires Artura 958

Page 34 © Baxi Heating U.K. Limited 2008. OWNER GUIDE OWNER GUIDE FOR WARRANTY AND SERVICE INFORMATION SEE PAGES 43 TO 47 ...

[Page 35] Valor Fires Artura 958

LIST OF CONTENTS Section Page SAFETY 36 GAS CONSUMPTION 37 APPLIANCE DIMENSIONS 38 OPERATING YOUR FIRE 39 The Oxysafe flame sensing and flue blockage safety system. 39 To light the fire. 39 Lighting with a taper. 40 To turn off. 41 CLEANING YO...

[Page 36] Valor Fires Artura 958

SAFETY Do have the fire installed by a competent person. In the United Kingdom, installation must be in accordance with the latest edition of the Gas Safety (installation & use) Regulations. In the Republic of Ireland, installation must be in acc...

[Page 37] Valor Fires Artura 958

Do get advice about the suitability of any wall covering near your fire. Soft wall coverings (e.g. embossed vinyl, etc.) which have a raised pattern are easily affected by heat. They may, therefore, scorch or become discoloured when close to a heatin...

[Page 38] Valor Fires Artura 958

APPLIANCE DIMENSIONS Page 38 © Baxi Heating U.K. Limited 2008. OWNER GUIDE Figure 1. Appliance dimensions and clearances (Fascia may differ from that shown) Key Description Dimension (mm) A Appliance height 702 B Appliance width 594 C Appliance d...

[Page 39] Valor Fires Artura 958

OPERATING YOUR FIRE The Oxysafe flame sensing and flue blockage safety system. For your safety, this appliance is fitted with a flue blockage safety device which will shut down the appliance in the event of abnormal flue conditions. This device is NO...

[Page 40] Valor Fires Artura 958

 Depress the control knob and turn anticlockwise towards the PILOT/IGN position (See figure 3). A spark should be generated at the pilot while turning. The spark should ignite the pilot. The pilot flame can be seen at the left side of the fuel ef...

[Page 41] Valor Fires Artura 958

To turn off.  To turn the main burner off but leave the pilot alight, partially depress the knob and turn to PILOT/IGN.  To turn the fire fully off, partially depress the knob and turn to OFF.  Wait at least three minutes before relighti...

[Page 42] Valor Fires Artura 958

 We suggest that you remove the ceramic fuel effect in the reverse order to that shown in the ceramic fuel effect installer and owner guide. This should have been left inside or attached to this guide by the installer. Burner. Remove any deposits...

[Page 43] Valor Fires Artura 958

WARRANTY AND SERVICE Standard Warranty Terms & Conditions The warranty is for 12 months subject to contract. In the United Kingdom servicing can be carried out either by a heateam service engineer or a CORGI registered installer. You must registe...

[Page 44] Valor Fires Artura 958

When calling heateam, it would be helpful if you could have the following information to hand:- 1. Fire serial number and fascia code (Located on the information label - See figure 5 on page 47). 2. Date of installation 3. Your installer name and a...

[Page 45] Valor Fires Artura 958

Page 45 © Baxi Heating U.K. Limited 2008. OWNER GUIDE ...

[Page 46] Valor Fires Artura 958

Page 46 © Baxi Heating U.K. Limited 2008. Installer Details (Block Capitals) Installer Name Corgi Registration Number. Company Name. Company Address Company Telephone number Company Fax number OWNER GUIDE ...

[Page 47] Valor Fires Artura 958

Page 47 © Baxi Heating U.K. Limited 2008. Figure 5. Information label location. Brand (Please tick) Baxi Valor Wonderfire Other........................ D D M M Y Y Date of Installation Fascia code - Can be found close to the information label (...

[Page 48] Valor Fires Artura 958

© Baxi Heating U.K. Limited 2008. ...