Fujitsu ETERNUS DX Configuration Manual

Download or browse on-line these Configuration Manual for Fujitsu ETERNUS DX Disk Server, Storage.

Fujitsu ETERNUS DX Disk Manual Information:

This manual for Fujitsu ETERNUS DX Disk, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 35 pages, and the size of the file at download is . The document type is Configuration Manual.

Download Manual

More Manuals:

In case you failed to obtain relevant information in this document, please, look through related operating manuals and user instructions for Fujitsu ETERNUS DX Disk. Just click one of the links below to go to the selected manual:

Summary of Contents:

[Page 1] Fujitsu ETERNUS DX Disk

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware ® ESX Driver Settings for Non-Fujitsu Converged Network Adapter Cards P3AM-4772-11ENZ0 ...

[Page 2] Fujitsu ETERNUS DX Disk

This page is intentionally left blank. ...

[Page 3] Fujitsu ETERNUS DX Disk

Preface This manual briefly explains the operations that need to be performed by the user in order to connect an ETERNUS DX to a server running VMware ® ESX and using Emulex Converged Network Adapter cards via an FCoE interface. This manual is used...

[Page 4] Fujitsu ETERNUS DX Disk

Table of Contents Chapter 1 Setup Procedure for Emulex Converged Network Adapter Cards 5 1.1 Workflow ........................................................................................................................................ 5 1.2 Se...

[Page 5] Fujitsu ETERNUS DX Disk

Chapter 1 Setup Procedure for Emulex Converged Network Adapter Cards This chapter describes how to set up the VMware ESX server and Converged Network Adapter card driver when connecting the ETERNUS DX storage systems to the server via Emulex Converg...

[Page 6] Fujitsu ETERNUS DX Disk

Setting Up Converged Network Adapter Card Driver Check the default setting values and number of ports for the Converged Network Adapter card, and set up the driver parameter values. • "1.2.4 Setting Up the Converged Network Adapter Card Driver...

[Page 7] Fujitsu ETERNUS DX Disk

1.2 Setting Up the Converged Network Adapter Cards This section describes how to set up the VMware ESX server for use with the Emulex Converged Network Adapter cards described in the "Server Support Matrix". Depending on the Converged Net...

[Page 8] Fujitsu ETERNUS DX Disk

3 Enter the number of the Converged Network Adapter card that is to be checked and press the [Enter] key. Example: ------------------------------------------------------------------------------- Emulex OneConnect FCoE BIOS Utility, xxxxx...

[Page 9] Fujitsu ETERNUS DX Disk

The following shows an example of this. Host name Server#1 IP Address 192.168.0.10 Physical slot name Converged Network Adapter card WWN Instance name Physical address Cable tag slot0 10 00 00 00 C9 D0 43 DD CD4C0000 SERV1_SLOT0 to SWITCH_1_port0 ...

[Page 10] Fujitsu ETERNUS DX Disk

1.2.2 Setting Up SAN Boot The following describes the procedure when performing SAN Boot. Depending on the Converged Network Adapter card used, the actual on-screen Converged Network Adapt- er card information may differ from that in the screenshot...

[Page 11] Fujitsu ETERNUS DX Disk

3 Select "Enable/Disable Boot from SAN" and press the [Enter] key. ------------------------------------------------------------------------------- Emulex OneConnect FCoE BIOS Utility, xxxxxxxx ------------------------------...

[Page 12] Fujitsu ETERNUS DX Disk

"Boot BIOS is : Disabled" should have changed to "Boot BIOS is : Enabled". ------------------------------------------------------------------------------- Emulex OneConnect FCoE BIOS Utility, xxxxxxxx ------------...

[Page 13] Fujitsu ETERNUS DX Disk

7 Select a boot device. Input "1" for "Select a Boot Entry:"and press the [Enter] key. ------------------------------------------------------------------------------- Emulex OneConnect FCoE BIOS Utility, xxxxxxxx ...

[Page 14] Fujitsu ETERNUS DX Disk

10 Select a boot device startup method (via WWPN or via DID). From the list of LUNs recognized by the device, select the LUN number whose setting is to be changed, input the number for "Enter a Selec- tion:"and press the [Enter] key. LUN: 0...

[Page 15] Fujitsu ETERNUS DX Disk

12 The window shown in Step 7 reappears.Check the settings. In this example, check that item #1 is listed as "Used", that the "WWPN" is set to the actual ETERNUS DX400 series WWPN, and that the "LUN" is set to "00&q...

[Page 16] Fujitsu ETERNUS DX Disk

1.2.4.1 For VMware vSphere 5.5 1 Record the module name for the Converged Network Adapter card that is loaded into VMware ESXi. The underlined portion indicates the loaded module name. In the following example, "lpfc" is the mod- ule name. ...

[Page 17] Fujitsu ETERNUS DX Disk

Use the following command to change the setting values when the driver parameter name is "lpfcX_lun_queue_depth", the number of I/Os is "8", the module name is "lpfc", and the number of ports is "2". # esxcli s...

[Page 18] Fujitsu ETERNUS DX Disk

3 Check the default value for the Converged Network Adapter card. Specify the module name for the Converged Network Adapter card that you recorded in Step 1 and check the default value. # esxcli system module parameters list -m lpfc820 | grep lpfc[0-...

[Page 19] Fujitsu ETERNUS DX Disk

1.2.4.3 For VMware vSphere 4 1 Record the module name for the Converged Network Adapter card that is loaded into VMware ESX. The underlined portion indicates the loaded module name. In the following example, "lpfc820" is the module name. # ...

[Page 20] Fujitsu ETERNUS DX Disk

5 Check the setting values. # esxcfg-module -g lpfc820 lpfc820 enabled = 1 options = 'lpfc0_lun_queue_depth=8 lpfc1_lun_queue_depth=8' 6 Reboot VMware ESX. # reboot Chapter 1 Setup Procedure for Emulex Converge...

[Page 21] Fujitsu ETERNUS DX Disk

Chapter 2 Setup Procedure for QLogic Converged Network Adapter Cards This chapter describes how to set up the VMware ESX server and driver when connecting the ETERNUS DX storage systems to the server via QLogic Converged Network Adapter cards. 2.1 W...

[Page 22] Fujitsu ETERNUS DX Disk

Setting Up Converged Network Adapter Card Driver Perform the settings for the Converged Network Adapter card driver. • "2.2.5 Setting Up the Converged Network Adapter Card Driver" (page 29) After completing all the required procedures in ...

[Page 23] Fujitsu ETERNUS DX Disk

2.2 Setting Up the Converged Network Adapter Cards This section describes how to set up the server with the QLogic Converged Network Adapter cards described in the "Server Support Matrix". Depending on the Converged Network Adapter card u...

[Page 24] Fujitsu ETERNUS DX Disk

The procedure is as follows: 1 Install the Converged Network Adapter card in the server. For the installation method, installable PCI bus slot position, activation of the installed slot, and notes regarding the Converged Network Adapter card, refer t...

[Page 25] Fujitsu ETERNUS DX Disk

7 Perform the BIOS settings for the Converged Network Adapter card. Check the parameter values in the [Adapter Settings] window against those in the following table. For details on how to set the values, refer to the BIOS Readme file and Converged Ne...

[Page 26] Fujitsu ETERNUS DX Disk

(2) Select the Converged Network Adapter card to be set (BIOS setting) in the [Select Host Adapter] window. The [Fast!UTIL Options] menu appears. Then perform Step 3 through Step 10. 11 Select [Exit Fast!UTIL] and press the [Enter] key. 12 Select [Re...

[Page 27] Fujitsu ETERNUS DX Disk

4 Check the values for each parameter. Selectable Boot Settings Selectable Boot: (Primary) Boot Port Name, Lun: Boot Port Name, Lun: Boot Port Name, Lun: Boot Port Name, Lun: Press “C” to clear a Boot Port Name entry...

[Page 28] Fujitsu ETERNUS DX Disk

8 Select [Reboot System] and press the [Enter] key. Exit Fast!UTIL Reboot System Return to Fast!UTIL The server reboots. To return to the [Fast!UTIL] menu, select [Return to Fast!UTIL]. 2.2.4 Installing VMware ESX • VMware ESX should be installed ...

[Page 29] Fujitsu ETERNUS DX Disk

2.2.5 Setting Up the Converged Network Adapter Card Driver Change the parameters for the Converged Network Adapter card driver. 2.2.5.1 For VMware vSphere 5.5 1 Record the module name for the Converged Network Adapter card that is loaded into VMware ...

[Page 30] Fujitsu ETERNUS DX Disk

This option cannot be individually applied to each port on the Converged Network Adapter card. All ports on the target Converged Network Adapter card are configured with the same settings. 4 Reboot VMware ESXi. # reboot 5 After rebooting VMware E...

[Page 31] Fujitsu ETERNUS DX Disk

When the value for this setting is changed, refer to "FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware ® ESX" and change the setting value for the Maximum Outstanding Disk Requests for virtual machine...

[Page 32] Fujitsu ETERNUS DX Disk

2 Check the default value for the Converged Network Adapter card. Specify the module name for the Converged Network Adapter card that you recorded in Step 1 and check the default value. # esxcfg-module -g qla2xxx qla2xxx enabled = 1 options = ' ...

[Page 33] Fujitsu ETERNUS DX Disk

Appendix A WWN Instance Management Table for the Server (Blank) This table is used for setting up the Converged Network Adapter cards. Utilize this table if necessary. Host name IP Address Physical slot name Converged Network Adapter card WWN In...

[Page 34] Fujitsu ETERNUS DX Disk

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware ® ESX Driver Settings for Non-Fujitsu Converged Network Adapter Cards P3AM-4772-11ENZ0 Date of issuance: June 2015 Issuance responsibility: FUJITSU LIMITED • The...

[Page 35] Fujitsu ETERNUS DX Disk

...