[Page 1] Siemens SITRANS F series

Operating Instructions SITRANS F Coriolis Flowmeters MASS 6000 Ex d transmitter Answers for industry. 08/2015 Edition ...

[Page 2] Siemens SITRANS F series

...

[Page 3] Siemens SITRANS F series

s Coriolis owmeters MASS 6000 Ex d transmitter Operating Instructions These Operating Instructions apply to Siemens products SITRANS MASS 6000 Ex d with order code commencing 7ME4110-2G, 7ME4110-2H, 7ME4110-2J. For use with sensor type MASS 210...

[Page 4] Siemens SITRANS F series

Contents 1. Introduction .................................................................................................................4 2. Installation ...............................................................................................

[Page 5] Siemens SITRANS F series

SITRANS F C MASSFLO  4 A5E02944883-AA 1. Introduction For safety reasons it is important that the following points, especially the points marked with a warning sign, are read and understood before the system is being installed: • Install...

[Page 6] Siemens SITRANS F series

SITRANS F C MASSFLO  5 A5E02944883-AA Mount the sensor on a vibration-free wall or steel frame as shown. Ensure that the sensor is not emptied of liquid (during normal operation) otherwise incorrect measurement will occur. With low flow, ...

[Page 7] Siemens SITRANS F series

SITRANS F C MASSFLO  6 A5E02944883-AA 2. Installation 2.3 Ex survey according to Directive 94/9/EC (ATEX) Applies to instruments used in underground mining operations, as well as their above ground operations, which can be endangered b...

[Page 8] Siemens SITRANS F series

SITRANS F C MASSFLO  7 A5E02944883-AA 2. Installation 2.4 Overview A = Ex e (Increased safety) B = Ex ia (Intrinsic safety) C = Ex d (Flameproof safety) MASS 6000 Ex-d Flameproof enlosure Ex d e ib [ia Ga] IIC T4 Gb 1. M20x1.5, black...

[Page 9] Siemens SITRANS F series

SITRANS F C MASSFLO  8 A5E02944883-AA 2. Installation 2.5 Device identication Transmitter MASS 6000 Ex-d label No. Meaning  1. NotiedbodyforQAsupervision:ULInternationalDEMKOA/S,Denmark ...

[Page 10] Siemens SITRANS F series

SITRANS F C MASSFLO  9 A5E02944883-AA 2.6 Approvals 2.7 Special conditions for safe use of MASS 6000 Ex-d sensor • For installations in which both the Ci and Li of the intrinsically safe apparatus exceeds1% of the Co and Lo paramete...

[Page 11] Siemens SITRANS F series

SITRANS F C MASSFLO  10 A5E02944883-AA The display/keypad can be rotated in steps of 90°. Please note the little tap on the back of the display frame which must correspond to the nut at the transmitter body when the display/keypad is rep...

[Page 12] Siemens SITRANS F series

SITRANS F C MASSFLO  11 A5E02944883-AA 3. Electrical connection Turn off the power supply before connecting input and output cables and wait 30 minutes before unscrewing the lid. 3. Electrical connection 3.1 Electrical connection compac...

[Page 13] Siemens SITRANS F series

SITRANS F C MASSFLO  12 A5E02944883-AA 3. Electrical connection 3.1 Electrical connection compact or remote (continued) Electrical connections are made through the front of the transmitter (view A), in the terminal housing. This housing...

[Page 14] Siemens SITRANS F series

SITRANS F C MASSFLO  13 A5E02944883-AA 3.3 SENSORPROM  unit The SENSORPROM  unit is normally factory-installed in compact units. In remote please in- stall the SENSORPROM  unitdeliveredwiththesensor.Tot/exc...

[Page 15] Siemens SITRANS F series

SITRANS F C MASSFLO  14 A5E02944883-AA 3. Electrical connection Disconnect the equipment from the supply circuits and wait 30 min. for dischanging the energy in the internal electronics before opening. Remove the rear cover, by loosening ...

[Page 16] Siemens SITRANS F series

SITRANS F C MASSFLO  15 A5E02944883-AA 3.5 Installation examples Current output in passive mode +D]DUG &XUUHQWRXWSXWLQ SDVVLYHPRGH ([]RQH 6DIH 6WDQGDUGEDUULHU HJ07/ Frequency/pulse output in ...

[Page 17] Siemens SITRANS F series

SITRANS F C MASSFLO  16 A5E02944883-AA 4. Technical data 4. Technical data 4.1 Transmitter MASS 6000 Ex-d Measurement of Massow[kg/s(lb/s)],volumeow[l/s(g/s)],fraction[%],Brix,density[kg/m 3 (...

[Page 18] Siemens SITRANS F series

SITRANS F C MASSFLO  17 A5E02944883-AA 4.1 Transmitter MASS 6000 Ex-d (continued) 4. Technical data Enclosure Material Stainless steel AISI 316 W1.4435 Rating Compact mounted on sensor, IP 67 (NEMA 4X) to IEC 60529 Remote m...

[Page 19] Siemens SITRANS F series

SITRANS F C MASSFLO  18 A5E02944883-AA Intrinsic safe terminals in the connections room are in general evaluated as „ia“ for gas group IIC. The output terminals 31-32 is set in „active mode“ which means that it can be connected to o...

[Page 20] Siemens SITRANS F series

SITRANS F C MASSFLO  19 A5E02944883-AA ([WHUQDO FRXQWHU &XW RII 4 4.2 Output characteristic MASS 6000 Ex-d Output  Bidirectionalmode Unidirectionalmode characteristics 0-20 mA 4-20 mA Frequency Puls...

[Page 21] Siemens SITRANS F series

SITRANS F C MASSFLO  20 A5E02944883-AA 5. Commissioning 5.1 Keypad and display layout Keypad Thekeypadisusedtosettheowmeter.Thefunctionofthekeysareasfollows: TOPUPKEY This key (ho...

[Page 22] Siemens SITRANS F series

SITRANS F C MASSFLO  21 A5E02944883-AA 5.2 Menu build-up The menustructureofaspecictypeoftransmitterisshowninamenuoverviewmap. Detailsofhowaspecicparameterissetisshow...

[Page 23] Siemens SITRANS F series

SITRANS F C MASSFLO  22 A5E02944883-AA 5.3 Menu overview 5. Commissioning ...

[Page 24] Siemens SITRANS F series

SITRANS F C MASSFLO  23 A5E02944883-AA 5.4 Menu details Basic settings menu 5. Commissioning Thedecimalpointforowrate,totalizer1andtotalizer2canbeindividuallypositioned. • open the respective w...

[Page 25] Siemens SITRANS F series

SITRANS F C MASSFLO  24 A5E02944883-AA 5.5 Outputs setting menu Current output Digital output Pulse Digital output Frequency 5. Commissioning The current output must be set off when not used. ...

[Page 26] Siemens SITRANS F series

SITRANS F C MASSFLO  25 A5E02944883-AA 'LJLWDORXWSXW 5HOD\RXWSXW (UURUOHYHO (UURUOHYHO (UURUQXPEHU 'LUHFWLRQ/LPLW  2II (UURUQXPEHU (UURUOHYHO (UURUQXPEHU 'LUHFWLRQOLPLW  2II (UURUQXPEH...

[Page 27] Siemens SITRANS F series

SITRANS F C MASSFLO  26 A5E02944883-AA 5.6 Reset mode Reset mode Intheresetmodemenuthetotalizer1and2andthebatchcyclecountercanbereset. 0-point adjustment 0-pointadjustmentofthe�...

[Page 28] Siemens SITRANS F series

SITRANS F C MASSFLO  27 A5E02944883-AA 6. Service 6. Service 6.1 List of error numbers Error Error text #Comment Outputs Input No. Remedy text status status 1 I1 - Power on OK Power on has ac...

[Page 29] Siemens SITRANS F series

SITRANS F C MASSFLO  28 A5E02944883-AA Symptom Output Error Cause Remedy signals code Empty display Minimum 1. Supply voltage 1. Check supply voltage 2. MASS 6000 defective 2. Replace MASS 6000 No ow signal Mini...

[Page 30] Siemens SITRANS F series

SITRANS F C MASSFLO  29 A5E02944883-AA 7. Ordering 7. Ordering 7.1 Transmitter MASS 6000 Ex-d for remote mounting Add-on module for remote and compact MASS 6000 Ex-d SENSORPROM  memory unit Cables and connectors Spare parts ...

[Page 31] Siemens SITRANS F series

Siemens A/S Flow Instruments Coriolisvej 1-3 DK-6400 Soenderborg www.siemens.com/processautomation A5E02944883 Subject to change without prior notice Order No.: A5E02944883 Lit. No.: A5E02944883-AA © Siemens AG 08/2015 For more information www.s...