[Page 1] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide 2/2014 Preface Introduction 1 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 RC1058-EN-02 ...

[Page 2] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide ii Copyright © 2014 Siemens AG All rights reserved. Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where expressly permitted. Violations a...

[Page 3] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Table of Contents iii Table of Contents Preface ................................................................................................................ v Alerts .........................................

[Page 4] Siemens RUGGEDCOM RX5000

Table of Contents RUGGEDCOM RX5000 Installation Guide iv 3.4 Fiber Optic Ethernet Ports .......................................................................................................... 22 3.5 SFP Optic Ethernet Ports .....................

[Page 5] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Preface Alerts v Preface This guide describes the RUGGEDCOM RX5000. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by net...

[Page 6] Siemens RUGGEDCOM RX5000

Preface RUGGEDCOM RX5000 Installation Guide vi Training For any questions about the documentation or for assistance finding a specific document, contact a Siemens sales representative. Training Siemens offers a wide range of educational services ra...

[Page 7] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 1 Introduction Feature Highlights 1 Introduction The RUGGEDCOM RX5000 is a high-port density routing and switching platform, designed to operate in harsh environments.The RX5000 can withstand high levels of...

[Page 8] Siemens RUGGEDCOM RX5000

Chapter 1 Introduction RUGGEDCOM RX5000 Installation Guide 2 Ports, Controls and Indicator LEDs ▪ Meets IEEE 1613 (electric utility substations) ▪ Exceeds IEC 61850-3 (electric utility substations) ▪ Exceeds IEC 61800-3 (variable speed drive sy...

[Page 9] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 1 Introduction Ports, Controls and Indicator LEDs 3 4 6 7 8 9 10 4 5 1 2 3 Figure 1: Modules 1. Control Module 2. Power Module 3. Line Module (Typical) 4. Alarm Indicator LED 5. Lamp ...

[Page 10] Siemens RUGGEDCOM RX5000

Chapter 1 Introduction RUGGEDCOM RX5000 Installation Guide 4 Ports, Controls and Indicator LEDs Alarm Indicator LED The alarm indicator LED illuminates when an alarm condition exists. Lamp Test/Alarm Cut-Off (LT/ACO) Button This button performs two f...

[Page 11] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 2 Installing the Device 5 Installing the Device The following sections describe how to install the device, including mounting the device, connecting power, and connecting the device to the network. DANGER! ...

[Page 12] Siemens RUGGEDCOM RX5000

Chapter 2 Installing the Device RUGGEDCOM RX5000 Installation Guide 6 Mounting the Device Section 2.1 Mounting the Device The RX5000 is designed for maximum mounting and display flexibility. It can be equipped with adapters that allow it to be instal...

[Page 13] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 2 Installing the Device Mounting the Device to a Panel 7 1 2 3 1 2 3 Figure 3: Adaptors 1. Rear 2. Front 3. Adaptor 2. If required, install adapters on the opposite side of the device to protec...

[Page 14] Siemens RUGGEDCOM RX5000

Chapter 2 Installing the Device RUGGEDCOM RX5000 Installation Guide 8 Connecting Power 1 2 2 Figure 4: Panel Mounting 1. Screw 2. Adaptor 2. Install the supplied screws to secure the adapters to the panel. Make sure the screws are torqued to 2...

[Page 15] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 2 Installing the Device Installing/Removing Power Supplies 9 • For 125/250 VDC rated equipment, an appropriately rated DC circuit breaker must be installed. • It is recommended to provide a separate cir...

[Page 16] Siemens RUGGEDCOM RX5000

Chapter 2 Installing the Device RUGGEDCOM RX5000 Installation Guide 10 Removing a Power Supply NOTE The power supplies are hot swappable. It is not necessary to disconnect power to the device before installing or removing a power supply. 1. Remove th...

[Page 17] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 2 Installing the Device Connecting AC Power 11 3 2 1 Figure 7: Removing a Power Supply 1. Screws 2. Power Supply 3. Chassis 3. Install the blank power module assembly into the empy slot to prevent t...

[Page 18] Siemens RUGGEDCOM RX5000

Chapter 2 Installing the Device RUGGEDCOM RX5000 Installation Guide 12 Connecting DC Power 1 2 3 Figure 8: AC Terminal Block Wiring 1. Live Terminal 2. Ground Terminal 3. Neutral Terminal 2. Connect the negative wire from the power source to ...

[Page 19] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 2 Installing the Device Grounding the Device 13 + 1 2 3 Figure 9: DC Terminal Block Wiring 1. Live Terminal 2. Ground Terminal 3. Neutral Terminal 2. Connect the negative wire from the power sourc...

[Page 20] Siemens RUGGEDCOM RX5000

Chapter 2 Installing the Device RUGGEDCOM RX5000 Installation Guide 14 Connecting the Failsafe Relay 2 1 Figure 10: Chassis Ground Connection 1. #8-32 Screw 2. #8 Ring Lug Section 2.4 Connecting the Failsafe Relay The failsafe relay on the Contr...

[Page 21] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 2 Installing the Device Connecting to the Device 15 Serial Console and Management Ports Connect a PC or terminal directly to the serial console or management ports to access the boot-time control and ROX II...

[Page 22] Siemens RUGGEDCOM RX5000

Chapter 2 Installing the Device RUGGEDCOM RX5000 Installation Guide 16 Cabling Recommendations Section 2.6 Cabling Recommendations Before connecting the device, be aware of the recommendations and considerations outlined in the following sections: �...

[Page 23] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 2 Installing the Device Gigabit Ethernet 1000Base-TX Cabling Recommendations 17 • Shielded/screened cabling can be used when required. Care should be taken to avoid the creation of ground loops with shiel...

[Page 24] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 2 Installing the Device Gigabit Ethernet 1000Base-TX Cabling Recommendations 18 ...

[Page 25] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 3 Communication Ports 19 Communication Ports The RX5000 can be equipped with various types of communication ports to enhance its abilities and performance. Each set of communication ports is part of a field...

[Page 26] Siemens RUGGEDCOM RX5000

Chapter 3 Communication Ports RUGGEDCOM RX5000 Installation Guide 20 Serial Ports • Section 3.6, “Installing/Removing Modules” • Section 3.7, “Connecting Multiple RS485 Devices” Section 3.1 Serial Ports The RX5000 supports DB9 serial port...

[Page 27] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 3 Communication Ports Switch Ports 21 Section 3.2 Switch Ports The RX5000 supports a single Layer 2 or Layer 3 switch module that can operate at 8 or 88 Gbps. The switch module supports either RJ45, LC (Luc...

[Page 28] Siemens RUGGEDCOM RX5000

Chapter 3 Communication Ports RUGGEDCOM RX5000 Installation Guide 22 Fiber Optic Ethernet Ports RJ45 receptacles at either end. Ground loops can cause excessive noise and interference, but more importantly, create a potential shock hazard that can re...

[Page 29] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 3 Communication Ports SFP Optic Ethernet Ports 23 21 Figure 20: MTRJ Port 1. Tx Connector 2. Rx Connector 21 Figure 21: LC Port 1. Tx Connector 2. Rx Connector 21 Figure 22: SC Port 1. Tx Connec...

[Page 30] Siemens RUGGEDCOM RX5000

Chapter 3 Communication Ports RUGGEDCOM RX5000 Installation Guide 24 Installing an SFP Optical Port Section 3.5.1 Installing an SFP Optical Port To install an SFP optical port, do the following: CAUTION! Electrical hazard – risk of damage to equipm...

[Page 31] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 3 Communication Ports Installing/Removing Modules 25 CAUTION! Electrical hazard – risk of damage to equipment. Make sure all electrostatic energy is dissipated before performing installing or removing com...

[Page 32] Siemens RUGGEDCOM RX5000

Chapter 3 Communication Ports RUGGEDCOM RX5000 Installation Guide 26 Removing a Module 4. Insert the new module into the slot. 1 2 3 Figure 27: Installing a Module 1. Chassis 2. Module 3. Screw 5. Tighten the screws to secure the module. 6. I...

[Page 33] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 3 Communication Ports Connecting Multiple RS485 Devices 27 1 2 3 Figure 28: Removing a Module 1. Chassis 2. Module 3. Screw 5. Install a new module or a blank module (to prevent the ingress of dust ...

[Page 34] Siemens RUGGEDCOM RX5000

Chapter 3 Communication Ports RUGGEDCOM RX5000 Installation Guide 28 Connecting Multiple RS485 Devices < 1219 m (4000 in) 120Ω 10nF 120Ω 10nF 1 2 3 5 5 6 4 Figure 29: Recommended RS485 Wiring 1. RX5000 Device 2. Common (Isolated Gro...

[Page 35] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 4 Technical Specifications Power Supply Specifications 29 Technical Specifications The following sections provide important technical specifications related to the device and available modules: • Section ...

[Page 36] Siemens RUGGEDCOM RX5000

Chapter 4 Technical Specifications RUGGEDCOM RX5000 Installation Guide 30 Fiber Optic Ethernet Port Specifications Order Code Speed e Connector Duplex e Cable Type f Wiring Standard g Maximum Distance h Isolation i SM02 10/100/1000Base-T RJ45 FDX/HDX...

[Page 37] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 4 Technical Specifications Gigabit Ethernet (1 Gbps) Optical Specifications 31 Order Code Mode Connector Type Cable Type (µm) Tx λ (typ.) (nm) Tx min. (dBm) Tx max. (dBm) Rx Sensitivity (dBm) Rx Saturatio...

[Page 38] Siemens RUGGEDCOM RX5000

Chapter 4 Technical Specifications RUGGEDCOM RX5000 Installation Guide 32 Mechanical Specifications Section 4.7 Mechanical Specifications Parameter Value Dimensions Refer to Chapter 5, Dimension Drawings. Weight 14-16 kg (30-35 lbs) Ingress Protectio...

[Page 39] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 5 Dimension Drawings 33 Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 175.3 25.4 177.8 479.8 469.6 133.4 117.6 101.6 12.7 16.0 16.0 31.8 5.8 10.9 446.8 441.7 221.5 311...

[Page 40] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 5 Dimension Drawings 34 ...

[Page 41] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 6 Certification Agency Approvals 35 Certification The RX5000 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory age...

[Page 42] Siemens RUGGEDCOM RX5000

Chapter 6 Certification RUGGEDCOM RX5000 Installation Guide 36 Industry Canada Compliance Section 6.3 Industry Canada Compliance CAN ICES-3 (A) / NMB-3 (A) Section 6.4 EMI and Environmental Type Tests The RX5000 has passed the following EMI and envir...

[Page 43] Siemens RUGGEDCOM RX5000

RUGGEDCOM RX5000 Installation Guide Chapter 6 Certification EMI and Environmental Type Tests 37 Test Description Test Levels Severity Levels DC Power ports 2.5 kV common, 1 kV differential mode @1MHz 3 AC Power ports 2.5 kV common, 1 kV differential ...

[Page 44] Siemens RUGGEDCOM RX5000

Chapter 6 Certification RUGGEDCOM RX5000 Installation Guide Test Description Test Levels DC Power ports 2 kVDC AC Power ports 2 kVAC Environmental Type Tests Test Description Test Levels IEC 60068-2-1 Cold Temperature Test Ad -40 °C (-40 °F), 16 Ho...